Angelo Donnici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Angelo Donnici has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Mazza
Dipartimento di Ingegneria Civile Università della Calabria Rende Italy
3 shared publications - Carolina Salvo
University of Calabria
1 shared publication - Mauro Francini
Laboratory of Interventions Management in Environmental Emergencies Conditions, University of Calabria, Via Pietro Bucci, Cubo 45/B, Arcavacata di Rende, 87036 Rende, Italy
1 shared publication - Rodolfo Labernarda
Dipartimento di Ingegneria Civile, Università della Calabria, Rende, Italy
1 shared publication - Sara Gaudio
Laboratory of Interventions Management in Environmental Emergencies Conditions, University of Calabria, Via Pietro Bucci, Cubo 45/B, Arcavacata di Rende, 87036 Rende, Italy
1 shared publication
Latest Publications
- Open Access
- 15 May 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (10) , 2961-2987
Structural and non‐structural numerical blind prediction of shaking table experimental tests on fixed‐base and base‐isolated hospitals
Base‐isolated hospitals are frequently preferred to fixed‐base ones because of their improved seismic structural performance. Despite this, the question remains open on the advisability of using this modern seismic protection technology in preference to other conventional solutions, on the grounds of a holistic approach based on limiting non‐structural damage as well as continuity of service to the community in the aftermath of an earthquake. Two full‐scale four‐storey (fixed‐base) and three‐storey (base‐isolated) hospital buildings have been recently built and subjected to three‐dimensional shaking table tests at the National Research Institute for Earth Science and Disaster Prevention (Japan), with particular attention to evaluating and classifying functionality of non‐structural components and vital medical equipment. A two‐phase experimental campaign was carried out considering two earthquakes scaled at different intensity levels and applied along the horizontal and vertical directions. The current study aims to provide results of a numerical structural and non‐structural blind prediction of these hospital settings. A homemade numerical code is developed to account for lumped plasticity modelling of steel frame members and variability of the friction coefficient of spherical sliding bearings. Moreover, three non‐structural components are modelled in the fixed‐base structure: that is, elastic single degree of freedom systems representing two tanks filled with sand at the top floor; elastic beam elements for piping at the third floor; five‐element macro‐model for the in‐plane‐out‐of‐plane nonlinear response of partition walls at the first floor. The identification of predominant vibration periods of the fixed‐base structure is carried out using a homemade numerical code based on the continuous wavelet transforms in combination with the complex Morlet wavelet. Finally, the sliding and rocking motion of three items of medical equipment (i.e., incubator at third floor, dialysis machine at second floor and surgical bed at first floor) are analysed by means of a homemade numerical code, considering acceleration time histories of selected structural nodes of the fixed‐base structure.
- 15 May 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (10) , 2961-2987
Open AccessStructural and non‐structural numerical blind prediction of shaking table experimental tests on fixed‐base and base‐isolated hospitals
Base‐isolated hospitals are frequently preferred to fixed‐base ones because of their improved seismic structural performance. Despite this, the question remains open on the advisability of using this modern seismic protection technology in preference to other conventional solutions, on the grounds of a holistic approach based on limiting non‐structural damage as well as continuity of service to the community in the aftermath of an earthquake. Two full‐scale four‐storey (fixed‐base) and three‐storey (base‐isolated) hospital buildings have been recently built and subjected to three‐dimensional shaking table tests at the National Research Institute for Earth Science and Disaster Prevention (Japan), with particular attention to evaluating and classifying functionality of non‐structural components and vital medical equipment. A two‐phase experimental campaign was carried out considering two earthquakes scaled at different intensity levels and applied along the horizontal and vertical directions. The current study aims to provide results of a numerical structural and non‐structural blind prediction of these hospital settings. A homemade numerical code is developed to account for lumped plasticity modelling of steel frame members and variability of the friction coefficient of spherical sliding bearings. Moreover, three non‐structural components are modelled in the fixed‐base structure: that is, elastic single degree of freedom systems representing two tanks filled with sand at the top floor; elastic beam elements for piping at the third floor; five‐element macro‐model for the in‐plane‐out‐of‐plane nonlinear response of partition walls at the first floor. The identification of predominant vibration periods of the fixed‐base structure is carried out using a homemade numerical code based on the continuous wavelet transforms in combination with the complex Morlet wavelet. Finally, the sliding and rocking motion of three items of medical equipment (i.e., incubator at third floor, dialysis machine at second floor and surgical bed at first floor) are analysed by means of a homemade numerical code, considering acceleration time histories of selected structural nodes of the fixed‐base structure.
- Open Access
- 20 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (22) , 15420
A Method for the Definition of Emergency Rescue Routes Based on the Out-of-Plane Seismic Collapse of Masonry Infills in Reinforced-Concrete-Framed Buildings
One of the main goals of disaster management planning is to ensure the effectiveness of the emergency measures when a hazard occurs. This happens only if the decision-makers use operational tools considering the structural characteristics of urban systems. Starting from these assumptions, the authors proposed an emergency management method based on the integrated work between two different scientific sectors, the urban planning and construction engineering sectors. The proposed method aims to evaluate the practicability of the strategic road network, as well as defining the emergency rescue routes based on the out-of-plane (OOP) seismic collapse of masonry infills (MIs) in reinforced concrete (RC)-framed buildings. The OOP failure of MIs is predicted according to an innovative MI macro-model. The authors test the method on a geographic area in the municipality of Gioia Tauro (Reggio Calabria, Italy). The results show that due to the collapse of MIs, the functionality of the strategic road network in emergency conditions can be compromised, causing losses of the urban systems’ performance. Based on the obtained results, the authors recommend that decision-makers use the proposed methodology to identify the vulnerable rescue paths and to locate the strategic infrastructure while spending the financial resources in a more effective way.
- 20 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (22) , 15420
Open AccessA Method for the Definition of Emergency Rescue Routes Based on the Out-of-Plane Seismic Collapse of Masonry Infills in Reinforced-Concrete-Framed Buildings
One of the main goals of disaster management planning is to ensure the effectiveness of the emergency measures when a hazard occurs. This happens only if the decision-makers use operational tools considering the structural characteristics of urban systems. Starting from these assumptions, the authors proposed an emergency management method based on the integrated work between two different scientific sectors, the urban planning and construction engineering sectors. The proposed method aims to evaluate the practicability of the strategic road network, as well as defining the emergency rescue routes based on the out-of-plane (OOP) seismic collapse of masonry infills (MIs) in reinforced concrete (RC)-framed buildings. The OOP failure of MIs is predicted according to an innovative MI macro-model. The authors test the method on a geographic area in the municipality of Gioia Tauro (Reggio Calabria, Italy). The results show that due to the collapse of MIs, the functionality of the strategic road network in emergency conditions can be compromised, causing losses of the urban systems’ performance. Based on the obtained results, the authors recommend that decision-makers use the proposed methodology to identify the vulnerable rescue paths and to locate the strategic infrastructure while spending the financial resources in a more effective way.
- Open Access
- 24 October 2020
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 19 (1) , 345-376
In-plane and out-of-plane seismic damage of masonry infills in existing r.c. structures: the case study of De Gasperi-Battaglia school in Norcia
A significant correlation between the in-plane (IP) and out-of-plane (OOP) damage propagation of masonry infills (MIs) is frequently observed after strong earthquakes, posing a serious problem as regards vulnerability of public buildings such as schools. The present work is aimed at identifying the effects of different IP and OOP modelling assumptions of MIs on their seismic damage. To this end, the state secondary school De Gasperi-Battaglia in Norcia (Italy), object of monitoring by the Department of Civil Protection since 2000, is investigated for the heterogeneity of infill typologies. The school is composed of a basement and three storeys above ground level, with a reinforced concrete (r.c.) framed structure having a long-shaped rectangular plan. Two typologies can be identified in terms of transverse layout of MIs: (i) double-leaf interior partitions, made of hollow clay bricks; (ii) double-leaf exterior infill walls, constituted by facade solid bricks paired with hollow clay bricks. In addition, partial height infills in the longitudinal direction, due to classroom windows, make the columns susceptible to short column effects. MIs are represented by a five-element macro-model predicting both in-plane (IP) and out-of-plane (OOP) behaviour through a horizontal nonlinear truss and four diagonal nonlinear beam elements, respectively. Stiffness and strength values in the OOP direction are also reduced considering the evolution of the IP damage. Three assumptions are investigated for the behaviour of structural MIs: i.e. elastic both IP and OOP; inelastic IP and elastic OOP; inelastic both IP and OOP. Bare and infilled test structures are subjected to biaxial spectrum-compatible accelerograms, to evaluate the IP and OOP damage levels and effectiveness of the OOP simplified verification proposed by seismic codes.
- 24 October 2020
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 19 (1) , 345-376
Open AccessIn-plane and out-of-plane seismic damage of masonry infills in existing r.c. structures: the case study of De Gasperi-Battaglia school in Norcia
A significant correlation between the in-plane (IP) and out-of-plane (OOP) damage propagation of masonry infills (MIs) is frequently observed after strong earthquakes, posing a serious problem as regards vulnerability of public buildings such as schools. The present work is aimed at identifying the effects of different IP and OOP modelling assumptions of MIs on their seismic damage. To this end, the state secondary school De Gasperi-Battaglia in Norcia (Italy), object of monitoring by the Department of Civil Protection since 2000, is investigated for the heterogeneity of infill typologies. The school is composed of a basement and three storeys above ground level, with a reinforced concrete (r.c.) framed structure having a long-shaped rectangular plan. Two typologies can be identified in terms of transverse layout of MIs: (i) double-leaf interior partitions, made of hollow clay bricks; (ii) double-leaf exterior infill walls, constituted by facade solid bricks paired with hollow clay bricks. In addition, partial height infills in the longitudinal direction, due to classroom windows, make the columns susceptible to short column effects. MIs are represented by a five-element macro-model predicting both in-plane (IP) and out-of-plane (OOP) behaviour through a horizontal nonlinear truss and four diagonal nonlinear beam elements, respectively. Stiffness and strength values in the OOP direction are also reduced considering the evolution of the IP damage. Three assumptions are investigated for the behaviour of structural MIs: i.e. elastic both IP and OOP; inelastic IP and elastic OOP; inelastic both IP and OOP. Bare and infilled test structures are subjected to biaxial spectrum-compatible accelerograms, to evaluate the IP and OOP damage levels and effectiveness of the OOP simplified verification proposed by seismic codes.