Daya Soni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daya Soni has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Poonam Kumari
CSIR-National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi-110012, India
7 shared publicationsGazal Garg
CSIR-National Physical Laboratory Dr. K. S. Krishnan Marg New Delhi 110012 India
5 shared publicationsKhem Singh
CSIR-National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi, India
5 shared publicationsShankar G. Aggarwal
CSIR-National Physical Laboratory, New Delhi, India
5 shared publicationsKomal
4 shared publicationsAkash Deep
Academy of Scientific and Innovative Research (AcSIR) Ghaziabad 201002 India
2 shared publications
Latest Publications
- Open Access
- 5 April 2024
- Published by The Korean Society of Environmental Health and Toxicology in Environmental Analysis Health and Toxicology
- Vol. 39 (2) , e2024012
Benzene: A critical review on measurement methodology, certified reference material, exposure limits with its impact on human health and mitigation strategies
Benzene is a carcinogenic pollutant with significant emission sources present in the atmosphere. The need for accurate and precise measurement of benzene in the atmosphere has become increasingly evident due to its toxicity and the adverse health effects associated with exposure to different concentrations. Certified reference material (CRM) is essential to establish the traceability of measurement results. The present review compiles the available national and international measurement methods, certified reference materials (CRMs) for benzene and the limit of benzene in fuel composition (v/v) worldwide. Overall, the review indicates the benzene level in the atmosphere and the resulting impacts on the environment and human health, which frequently exceed the exposure limits of different environment regulatory agencies. An extensive literature review was conducted to gather information on monitoring and analysis methods for benzene, revealing that the most preferred method, i.e. Gas Chromatography- Flame Ionization Detector and Mass Spectrometry, is neither cost-effective nor suitable for real-time continuous monitoring. By analysing existing literature and studies, this review will shed light on the understanding of the importance of benzene pollution monitoring in ambient air and its implications for public health. Additionally, it will reflect the mitigation strategies applied by regulators & need for future revisions of air quality guidelines.
- 5 April 2024
- Published by The Korean Society of Environmental Health and Toxicology in Environmental Analysis Health and Toxicology
- Vol. 39 (2) , e2024012
Open AccessBenzene: A critical review on measurement methodology, certified reference material, exposure limits with its impact on human health and mitigation strategies
Benzene is a carcinogenic pollutant with significant emission sources present in the atmosphere. The need for accurate and precise measurement of benzene in the atmosphere has become increasingly evident due to its toxicity and the adverse health effects associated with exposure to different concentrations. Certified reference material (CRM) is essential to establish the traceability of measurement results. The present review compiles the available national and international measurement methods, certified reference materials (CRMs) for benzene and the limit of benzene in fuel composition (v/v) worldwide. Overall, the review indicates the benzene level in the atmosphere and the resulting impacts on the environment and human health, which frequently exceed the exposure limits of different environment regulatory agencies. An extensive literature review was conducted to gather information on monitoring and analysis methods for benzene, revealing that the most preferred method, i.e. Gas Chromatography- Flame Ionization Detector and Mass Spectrometry, is neither cost-effective nor suitable for real-time continuous monitoring. By analysing existing literature and studies, this review will shed light on the understanding of the importance of benzene pollution monitoring in ambient air and its implications for public health. Additionally, it will reflect the mitigation strategies applied by regulators & need for future revisions of air quality guidelines.
- 9 February 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (6)
Gravimetric Preparation of Toluene CGMs in Nitrogen Gas: Verification and Stability Assessment
This research paper presents the preparation, verification and stability evaluation of a toluene calibration gas mixtures (CGMs) in nitrogen gas via gravimetric method. These toluene gas mixtures are prepared gravimetrically i. e., by wt. mixing of high‐purity gases according to the International Organization for Standardization, ISO 6142, and are validated as per ISO 6143. Toluene gas mixtures within the range of 5 to 20 μmol/mol are prepared and traceability with SI, ‘International system of units’, amount of substance, the ′mole′, through mass‐based measurements is achieved. The verification of prepared CGMs was carried out using a GC‐FID (gas chromatography with flame ionization detector) technique, and the outcomes demonstrated a consistent linear correlation between instrumental response and gravimetric amount fraction for all gas mixtures, which confirmed the accuracy and reliability of CGMs. The gravimetric uncertainty of the prepared gas mixtures, as projected in terms of amount fractions, is below 1 % relative, while the analytical uncertainty is in the range of 2–3 % relative at a confidence level of k=1. The stability study investigation over a period of one year demonstrated that the mole fraction of toluene remained consistent throughout the entire duration, which indicated the long‐term stability of the CGMs.
- 9 February 2024
- Published by Wiley in ChemistrySelect
- Vol. 9 (6)
Gravimetric Preparation of Toluene CGMs in Nitrogen Gas: Verification and Stability Assessment
This research paper presents the preparation, verification and stability evaluation of a toluene calibration gas mixtures (CGMs) in nitrogen gas via gravimetric method. These toluene gas mixtures are prepared gravimetrically i. e., by wt. mixing of high‐purity gases according to the International Organization for Standardization, ISO 6142, and are validated as per ISO 6143. Toluene gas mixtures within the range of 5 to 20 μmol/mol are prepared and traceability with SI, ‘International system of units’, amount of substance, the ′mole′, through mass‐based measurements is achieved. The verification of prepared CGMs was carried out using a GC‐FID (gas chromatography with flame ionization detector) technique, and the outcomes demonstrated a consistent linear correlation between instrumental response and gravimetric amount fraction for all gas mixtures, which confirmed the accuracy and reliability of CGMs. The gravimetric uncertainty of the prepared gas mixtures, as projected in terms of amount fractions, is below 1 % relative, while the analytical uncertainty is in the range of 2–3 % relative at a confidence level of k=1. The stability study investigation over a period of one year demonstrated that the mole fraction of toluene remained consistent throughout the entire duration, which indicated the long‐term stability of the CGMs.
- 2 December 2023
- Published by Elsevier in Microchemical Journal
- Vol. 197
A review on preparation methods and measurement techniques of reference gas mixtures
- 2 December 2023
- Published by Elsevier in Microchemical Journal
- Vol. 197
A review on preparation methods and measurement techniques of reference gas mixtures
- 15 September 2023
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 28 (5) , 209-220
A case study for in-house method validation of gas chromatography technique using class-1 calibration gas mixtures for greenhouse gases monitoring
- 15 September 2023
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 28 (5) , 209-220
A case study for in-house method validation of gas chromatography technique using class-1 calibration gas mixtures for greenhouse gases monitoring
- Open Access
- 23 August 2023
- Published by The Korean Society of Environmental Health and Toxicology in Environmental Analysis Health and Toxicology
- Vol. 38 (3) , e2023016
Seasonal and diurnal measurement of ambient benzene at a high traffic inflation site in Delhi: Health risk assessment and its possible role in ozone formation pathways
Benzene is the most toxic and hazardous pollutant among volatile organic compounds (VOCs), as it comes under group 1 carcinogens recognized by the International Agency for Research on Cancer (IARC). It also plays a significant role in forming secondary pollutants like ozone. The benzene concentration was measured using a charcoal sorbent tube by active sampling at a traffic junction and analysis was done using GC-FID. The maximum average concentration of benzene in ambient air was found to be 33 μg/m3. A diurnal study of benzene measurement shows higher benzene concentrations in the evening compared to the morning. Seasonal variation of benzene is found to be winter > spring > summer > autumn > monsoon and OFP was found to be 21, 19, 14, 13, and 10 respectively. Cancer (ILCR) and non-cancer (HQ) health risk assessment was done to determine the impact of ambient benzene on the residents of urban areas. The yearly average value of ILCR was found to be 2×10-6 ± 1×10-6 which ranges from acceptable value to three times the WHO acceptable value i.e 1×10-6. The correlation of ozone and its precursor, benzene with meteorological parameters is also evaluated. The correlation of benzene and ozone with solar radiation shows the influence of photochemical reactions on the levels of benzene and ozone at the study site, although it is low.
- 23 August 2023
- Published by The Korean Society of Environmental Health and Toxicology in Environmental Analysis Health and Toxicology
- Vol. 38 (3) , e2023016
Open AccessSeasonal and diurnal measurement of ambient benzene at a high traffic inflation site in Delhi: Health risk assessment and its possible role in ozone formation pathways
Benzene is the most toxic and hazardous pollutant among volatile organic compounds (VOCs), as it comes under group 1 carcinogens recognized by the International Agency for Research on Cancer (IARC). It also plays a significant role in forming secondary pollutants like ozone. The benzene concentration was measured using a charcoal sorbent tube by active sampling at a traffic junction and analysis was done using GC-FID. The maximum average concentration of benzene in ambient air was found to be 33 μg/m3. A diurnal study of benzene measurement shows higher benzene concentrations in the evening compared to the morning. Seasonal variation of benzene is found to be winter > spring > summer > autumn > monsoon and OFP was found to be 21, 19, 14, 13, and 10 respectively. Cancer (ILCR) and non-cancer (HQ) health risk assessment was done to determine the impact of ambient benzene on the residents of urban areas. The yearly average value of ILCR was found to be 2×10-6 ± 1×10-6 which ranges from acceptable value to three times the WHO acceptable value i.e 1×10-6. The correlation of ozone and its precursor, benzene with meteorological parameters is also evaluated. The correlation of benzene and ozone with solar radiation shows the influence of photochemical reactions on the levels of benzene and ozone at the study site, although it is low.
- Open Access
- 21 July 2023
- Published by Springer Nature in Asian Journal of Atmospheric Environment
- Vol. 17 (1) , 1-11
Measurement of benzene and other volatile organic compounds: implications for its inhalation health risk associated with the workers at a fuel station in Delhi
Exposure to benzene and other volatile organic compounds (VOCs) like toluene, ethylbenzene, o-, m-, and p-xylene (BTEX) at a fuel station is hazardous for the workers. This study aims to estimate the health risk for worker due to the exposure of BTEX after implementation of vapour recovery system (VRS) at fuel stations. Air samples were collected using low-flow sampling pump as per NIOSH method by using Tenax (sorbent) tubes and charcoal (sorbent) tubes. Target compounds were extracted using acetone and analysed by gas chromatography equipped with flame ionization detector (FID). The cancer risk (CR) and hazard quotient (HQ) were estimated to assess the cancer and non-cancer risk following the United States of Environmental Protection Agency (USEPA) updated methodology. The average concentration of VOCs at the fuel station is found in the order toluene > benzene > xylene > ethylbenzene which may be attributed to the composition of fuel (petrol/diesel). Benzene is the most carcinogenic among BTEX, which is found to be 217 ± 9 µg m−3 and 158 ± 9 µg m−3 in the month of November 2021 using Tenax sorbent and charcoal sorbent tubes, respectively. The high concentration observed using Tenax sorbent may be attributed to its high adsorption efficacy than charcoal due to larger surface area and porosity. The 7-month average CR value of benzene was 9 × 10−4 using Tenax sorbent and exceeds the acceptable range of 1 × 10−6. CR of benzene exposure at the fuel station under study is also compared with that of outdoor ambient air exposure. Benzene measurement data for the same duration was taken from nearby online monitoring station of Delhi Pollution Control Committee (DPCC) PUSA to estimate CR value for outdoor ambient air benzene exposure. The value of HQ for benzene was observed > 1 which exceeds the acceptable value and hence increased the non-cancer health risk also. Hazard index (HI) value for BTEX is also greater than 1 which indicates adverse health effects of benzene and other VOCs at the fuel station. The high CR and HQ values for benzene are a matter of concern for fuel station workers.
- 21 July 2023
- Published by Springer Nature in Asian Journal of Atmospheric Environment
- Vol. 17 (1) , 1-11
Open AccessMeasurement of benzene and other volatile organic compounds: implications for its inhalation health risk associated with the workers at a fuel station in Delhi
Exposure to benzene and other volatile organic compounds (VOCs) like toluene, ethylbenzene, o-, m-, and p-xylene (BTEX) at a fuel station is hazardous for the workers. This study aims to estimate the health risk for worker due to the exposure of BTEX after implementation of vapour recovery system (VRS) at fuel stations. Air samples were collected using low-flow sampling pump as per NIOSH method by using Tenax (sorbent) tubes and charcoal (sorbent) tubes. Target compounds were extracted using acetone and analysed by gas chromatography equipped with flame ionization detector (FID). The cancer risk (CR) and hazard quotient (HQ) were estimated to assess the cancer and non-cancer risk following the United States of Environmental Protection Agency (USEPA) updated methodology. The average concentration of VOCs at the fuel station is found in the order toluene > benzene > xylene > ethylbenzene which may be attributed to the composition of fuel (petrol/diesel). Benzene is the most carcinogenic among BTEX, which is found to be 217 ± 9 µg m−3 and 158 ± 9 µg m−3 in the month of November 2021 using Tenax sorbent and charcoal sorbent tubes, respectively. The high concentration observed using Tenax sorbent may be attributed to its high adsorption efficacy than charcoal due to larger surface area and porosity. The 7-month average CR value of benzene was 9 × 10−4 using Tenax sorbent and exceeds the acceptable range of 1 × 10−6. CR of benzene exposure at the fuel station under study is also compared with that of outdoor ambient air exposure. Benzene measurement data for the same duration was taken from nearby online monitoring station of Delhi Pollution Control Committee (DPCC) PUSA to estimate CR value for outdoor ambient air benzene exposure. The value of HQ for benzene was observed > 1 which exceeds the acceptable value and hence increased the non-cancer health risk also. Hazard index (HI) value for BTEX is also greater than 1 which indicates adverse health effects of benzene and other VOCs at the fuel station. The high CR and HQ values for benzene are a matter of concern for fuel station workers.
- 25 June 2023
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 141, 314-329
Comparative measurement of CO2, CH4 and CO at two traffic interjunctions having inflated vehicular flow in Delhi
- 25 June 2023
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 141, 314-329
Comparative measurement of CO2, CH4 and CO at two traffic interjunctions having inflated vehicular flow in Delhi
- 22 June 2023
- Published by Wiley in ChemistrySelect
- Vol. 8 (24)
Impurity Analysis of 5.5 N Nitrogen Gas and Its Impact on the Preparation of Class I Type Calibration Gas Mixtures
Knowledge of impurities in matrix gas is one of the critical requirements for the preparation of class I type calibration gas mixtures (primary reference gas mixtures, PRGMs) as per ISO 6142‐1. PRGMs are prepared gravimetrically using high‐purity component gas and high‐grade nitrogen, here 99.9995 % (5.5 N) as matrix gas. In this study, quantification of gaseous impurities such as moisture (H 2 O), methane (CH 4 ), and carbon monoxide (CO) in 5.5 N nitrogen is performed using CRDS (cavity ring down spectroscopy). Carbon dioxide (CO 2 ) and total hydrocarbons (THC) are analyzed using gas chromatography flame ionization detector (GC‐FID), while the determination of nitrogen dioxide (NO 2 ) impurity is conducted colorimetrically using a UV‐Vis spectrophotometer. Total impurities in 5.5 N nitrogen are found to be (2945±21.5) ppb. The impact of utilizing this nitrogen is examined through the stability study of ambient range binary component gas mixtures of CH 4 and CO in nitrogen and found that 5.5 N nitrogen can be used as matrix gas for preparing PRGMs of CH 4 and CO. However, the component gas impurity present in nitrogen potentially affect the accuracy of gravimetrically prepared gas mixture.
- 22 June 2023
- Published by Wiley in ChemistrySelect
- Vol. 8 (24)
Impurity Analysis of 5.5 N Nitrogen Gas and Its Impact on the Preparation of Class I Type Calibration Gas Mixtures
Knowledge of impurities in matrix gas is one of the critical requirements for the preparation of class I type calibration gas mixtures (primary reference gas mixtures, PRGMs) as per ISO 6142‐1. PRGMs are prepared gravimetrically using high‐purity component gas and high‐grade nitrogen, here 99.9995 % (5.5 N) as matrix gas. In this study, quantification of gaseous impurities such as moisture (H 2 O), methane (CH 4 ), and carbon monoxide (CO) in 5.5 N nitrogen is performed using CRDS (cavity ring down spectroscopy). Carbon dioxide (CO 2 ) and total hydrocarbons (THC) are analyzed using gas chromatography flame ionization detector (GC‐FID), while the determination of nitrogen dioxide (NO 2 ) impurity is conducted colorimetrically using a UV‐Vis spectrophotometer. Total impurities in 5.5 N nitrogen are found to be (2945±21.5) ppb. The impact of utilizing this nitrogen is examined through the stability study of ambient range binary component gas mixtures of CH 4 and CO in nitrogen and found that 5.5 N nitrogen can be used as matrix gas for preparing PRGMs of CH 4 and CO. However, the component gas impurity present in nitrogen potentially affect the accuracy of gravimetrically prepared gas mixture.
- 11 May 2023
- Published by Springer Nature in MAPAN
- Vol. 38 (3) , 707-713
Preparation, Verification and Stability of Calibration Gas Mixture of Benzene in Nitrogen
- 11 May 2023
- Published by Springer Nature in MAPAN
- Vol. 38 (3) , 707-713
Preparation, Verification and Stability of Calibration Gas Mixture of Benzene in Nitrogen