Yuanlin Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuanlin Xia has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Zhuqing Wang
School of Mechanical Engineering, Sichuan University, Chengdu, China
16 shared publications - Cao Xia
Sichuan University
12 shared publications - Yubo Huang
School of Mechanical Engineering, Sichuan University, Chengdu 610065, China
4 shared publications - Hongyang Xiao
Pittsburgh Institute, Sichuan University, Chengdu 610225, China
3 shared publications - Jiaxing Tan
Division of Nephrology, Department of Medicine, West China Hospital, Sichuan University, Chengdu, Sichuan, China
3 shared publications - Liang He
School of Mechanical Engineering, State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, Sichuan University, Chengdu 610065, China
3 shared publications
Latest Publications
- 1 November 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (11) , 115019
Exploiting LCE-SMP synergy for reconfigurable double layer actuators with controlled shape transformation
Microactuators face challenges in combining active deformation, shape retention, and mechanical robustness within a single material system. This work presents a bilayer actuator composed of a liquid crystal elastomer (LCE) and an epoxy shape-memory polymer (SMP), with a thickness of approximately 400 μ m and an overall size at the millimeter scale. In the bilayer, the LCE layer provides thermally induced actuation, whereas the SMP layer enables temporary-shape fixation and subsequent recovery toward its permanent shape. The actuator therefore undergoes a heating-induced bending, cooling-induced fixation, and reheating-induced recovery cycle. Fabricated by sequential blade coating, the bilayer films were used to investigate how nominal layer configuration influences the bending response. After 25 bending–recovery cycles, the actuator retained a repeatable cyclic response. A microvalve and a temperature-controlled switch were further demonstrated to illustrate potential device applications.
- 1 November 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (11) , 115019
Exploiting LCE-SMP synergy for reconfigurable double layer actuators with controlled shape transformation
Microactuators face challenges in combining active deformation, shape retention, and mechanical robustness within a single material system. This work presents a bilayer actuator composed of a liquid crystal elastomer (LCE) and an epoxy shape-memory polymer (SMP), with a thickness of approximately 400 μ m and an overall size at the millimeter scale. In the bilayer, the LCE layer provides thermally induced actuation, whereas the SMP layer enables temporary-shape fixation and subsequent recovery toward its permanent shape. The actuator therefore undergoes a heating-induced bending, cooling-induced fixation, and reheating-induced recovery cycle. Fabricated by sequential blade coating, the bilayer films were used to investigate how nominal layer configuration influences the bending response. After 25 bending–recovery cycles, the actuator retained a repeatable cyclic response. A microvalve and a temperature-controlled switch were further demonstrated to illustrate potential device applications.
- 15 October 2026
- Published by Elsevier in Measurement
- Vol. 292
Data-Driven soft sensing of Two-Dimensional gaze angles from MEMS-Mirror scanning signals
- 15 October 2026
- Published by Elsevier in Measurement
- Vol. 292
Data-Driven soft sensing of Two-Dimensional gaze angles from MEMS-Mirror scanning signals
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
VR Strabismus Screening System With Coordinated Mechanical Occlusion and Target Guidance
This study proposes an innovative measurement framework for strabismus detection based on VR eye-tracking technology, which integrates three clinical diagnosis methods: the cover-uncover test (CUT), alternate-cover test (ACT), and nine-position test (NPT). The synergistic use of mechanical occlusion modules and virtual markers disrupts binocular fusion while monitoring eye movement patterns. Through quantitative characterization of eye movement trajectories, strabismus conditions are identified via sensing and recognition of pathological features. The measurement process was implemented in Unity3D software, with eye-tracking parameters recorded for estimation analysis. The system achieves complete strabismus detection within 87 s. Clinical validation demonstrates its capability to diagnose strabismus by tracking deviations between subject-specific eye movement data and normative References under controlled occlusion and visual guidance. This approach establishes a portable, highly integrated measurement platform with child-adaptive interactivity. The integration of physical occlusion dynamics with virtual monitoring represents a unique advancement in instrumentation for strabismus phenomenon characterization, bridging clinical diagnostics, and precision measurement technologies.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
VR Strabismus Screening System With Coordinated Mechanical Occlusion and Target Guidance
This study proposes an innovative measurement framework for strabismus detection based on VR eye-tracking technology, which integrates three clinical diagnosis methods: the cover-uncover test (CUT), alternate-cover test (ACT), and nine-position test (NPT). The synergistic use of mechanical occlusion modules and virtual markers disrupts binocular fusion while monitoring eye movement patterns. Through quantitative characterization of eye movement trajectories, strabismus conditions are identified via sensing and recognition of pathological features. The measurement process was implemented in Unity3D software, with eye-tracking parameters recorded for estimation analysis. The system achieves complete strabismus detection within 87 s. Clinical validation demonstrates its capability to diagnose strabismus by tracking deviations between subject-specific eye movement data and normative References under controlled occlusion and visual guidance. This approach establishes a portable, highly integrated measurement platform with child-adaptive interactivity. The integration of physical occlusion dynamics with virtual monitoring represents a unique advancement in instrumentation for strabismus phenomenon characterization, bridging clinical diagnostics, and precision measurement technologies.
- Open Access
- 15 October 2025
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 32 (5) , 1631-1638
Design and Performance Analysis of Dual Straight Beam MEMS Micro Mirrors for Enhanced Scanning Capabilities
Micro-Opto-Electro-Mechanical Systems (MOEMS) technology is rapidly developing, with micro scanning devices centered around MEMS micro-mirrors increasingly becoming a research focus. Addressing the shortcomings of single-cantilever MEMS micro-mirrors...
- 15 October 2025
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 32 (5) , 1631-1638
Open AccessDesign and Performance Analysis of Dual Straight Beam MEMS Micro Mirrors for Enhanced Scanning Capabilities
Micro-Opto-Electro-Mechanical Systems (MOEMS) technology is rapidly developing, with micro scanning devices centered around MEMS micro-mirrors increasingly becoming a research focus. Addressing the shortcomings of single-cantilever MEMS micro-mirrors...
- Open Access
Single-Thermocouple Suspended Microfluidic Thermal Sensor with Improved Heat Retention for the Development of Multifunctional Biomedical Detection
Thermal sensors are widely used in medical, industrial and other fields, where the requirements for high sensitivity and portability continues to increase. Here we propose a suspended bridge structure fabricated using MEMS, which effectively shrinks the size and reduces heat loss. This study reviews current sensor-related theories of heat conduction, convective heat transfer and thermal radiation. Heat loss models for suspended and non-suspended bridge structures are established, and finite element analysis is conducted to evaluate their thermal performance. The thermal performance of the suspended bridge structure is further validated through infrared temperature measurements on the manufactured sensor device. Theoretical calculations demonstrate that the proposed suspension bridge structure reduces heat loss by 88.64% compared with traditional designs. Benefiting from this improved heat retention, which was also confirmed by infrared thermography, the thermal sensor fabricated based on the suspension bridge structure achieves an ultra-high sensitivity of 0.38 V/W and a fast response time of less than 200 ms, indicating a high accuracy in thermal characterization. The correlation coefficient obtained for the sensor output voltage and input power of the sensor is approximately 1.0. Based on this design, multiple microfluidic channels with suspended bridge structures can be integrated to realize multi-component detection, which is important for the development of multifunctional biomedical detection.
Open AccessSingle-Thermocouple Suspended Microfluidic Thermal Sensor with Improved Heat Retention for the Development of Multifunctional Biomedical Detection
Thermal sensors are widely used in medical, industrial and other fields, where the requirements for high sensitivity and portability continues to increase. Here we propose a suspended bridge structure fabricated using MEMS, which effectively shrinks the size and reduces heat loss. This study reviews current sensor-related theories of heat conduction, convective heat transfer and thermal radiation. Heat loss models for suspended and non-suspended bridge structures are established, and finite element analysis is conducted to evaluate their thermal performance. The thermal performance of the suspended bridge structure is further validated through infrared temperature measurements on the manufactured sensor device. Theoretical calculations demonstrate that the proposed suspension bridge structure reduces heat loss by 88.64% compared with traditional designs. Benefiting from this improved heat retention, which was also confirmed by infrared thermography, the thermal sensor fabricated based on the suspension bridge structure achieves an ultra-high sensitivity of 0.38 V/W and a fast response time of less than 200 ms, indicating a high accuracy in thermal characterization. The correlation coefficient obtained for the sensor output voltage and input power of the sensor is approximately 1.0. Based on this design, multiple microfluidic channels with suspended bridge structures can be integrated to realize multi-component detection, which is important for the development of multifunctional biomedical detection.
- 27 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
A Wireless Pulse Diagnostic Device Utilizing MEMS Pressure Sensor Array for Sleep Apnea Detection
Inspired by traditional Chinese medicine pulse diagnosis, a wireless pulse diagnostic device, based on a Micro Electro Mechanical Systems (MEMS) pressure sensor array, was designed to detect sleep apnea. The arrayed MEMS pressure sensor configuration within a silica gel casing, capturing multidimensional pulse signals at the radial artery positions. Pulse signals were collected from volunteers during normal breathing and breath-holding scenarios to establish a comprehensive sleep apnea recognition database. A feature vector incorporating the pulse contour characteristic K-value, Reflection Index (RI), Power Ratio (PR), and Heart Rate (HR) was created for classification model training using a Support Vector Machine (SVM). Experimental results showed that the accuracy of pulse wave signal feature vector classification is 99.33% and the sensitivity is 98%. Overall, this device offers innovative technical support and significant application potential to advance modernized traditional Chinese diagnostic methods and intelligent medical devices.
- 27 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
A Wireless Pulse Diagnostic Device Utilizing MEMS Pressure Sensor Array for Sleep Apnea Detection
Inspired by traditional Chinese medicine pulse diagnosis, a wireless pulse diagnostic device, based on a Micro Electro Mechanical Systems (MEMS) pressure sensor array, was designed to detect sleep apnea. The arrayed MEMS pressure sensor configuration within a silica gel casing, capturing multidimensional pulse signals at the radial artery positions. Pulse signals were collected from volunteers during normal breathing and breath-holding scenarios to establish a comprehensive sleep apnea recognition database. A feature vector incorporating the pulse contour characteristic K-value, Reflection Index (RI), Power Ratio (PR), and Heart Rate (HR) was created for classification model training using a Support Vector Machine (SVM). Experimental results showed that the accuracy of pulse wave signal feature vector classification is 99.33% and the sensitivity is 98%. Overall, this device offers innovative technical support and significant application potential to advance modernized traditional Chinese diagnostic methods and intelligent medical devices.
- 22 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 34 (4) , 399-407
Defect Excitation and Failure Analysis of MEMS Gas Sensors Based on FTA and RET Methods
The reliability of microelectromechanical system (MEMS) gas sensors is critical for their deployment in industrial automation and environmental monitoring. However, failure mechanisms under harsh conditions remain poorly understood. This study combines Fault Tree Analysis (FTA) and Reliability Enhancement Testing (RET) to systematically investigate defect excitation in MEMS gas sensors. The FTA identifies gas-sensitive films and microheaters as weak links, while the RET reveals a 93.3% failure rate under controlled thermal and mechanical stresses. Microscopic analysis demonstrates that microcracks in the gas-sensitive film originate from mismatched thermal expansion coefficients between the film and electrodes, exacerbated by primary defects introduced during fabrication. These findings not only advance the understanding of failure mechanisms in MEMS devices but also propose design optimizations to enhance material compatibility and manufacturing processes. This work aligns with the growing demand for high-reliability MEMS sensors in applications such as biomedical diagnostics and hazardous environments monitoring, offering a roadmap for durable sensor development. [2025-0033]
- 22 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 34 (4) , 399-407
Defect Excitation and Failure Analysis of MEMS Gas Sensors Based on FTA and RET Methods
The reliability of microelectromechanical system (MEMS) gas sensors is critical for their deployment in industrial automation and environmental monitoring. However, failure mechanisms under harsh conditions remain poorly understood. This study combines Fault Tree Analysis (FTA) and Reliability Enhancement Testing (RET) to systematically investigate defect excitation in MEMS gas sensors. The FTA identifies gas-sensitive films and microheaters as weak links, while the RET reveals a 93.3% failure rate under controlled thermal and mechanical stresses. Microscopic analysis demonstrates that microcracks in the gas-sensitive film originate from mismatched thermal expansion coefficients between the film and electrodes, exacerbated by primary defects introduced during fabrication. These findings not only advance the understanding of failure mechanisms in MEMS devices but also propose design optimizations to enhance material compatibility and manufacturing processes. This work aligns with the growing demand for high-reliability MEMS sensors in applications such as biomedical diagnostics and hazardous environments monitoring, offering a roadmap for durable sensor development. [2025-0033]
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Adaptive Dynamic Measurement, Trajectory Correction, and Error Evaluation Method in MEMS LiDAR System
In MEMS LiDAR systems, external mechanical disturbances can lead to abnormal trajectory deformations and incoherent 2D point cloud sampling artifacts. To address these challenges, this study proposes a novel measurement framework that enables real-time suppression of trajectory errors through dynamic, adaptive adjustment of scanning parameters (amplitude, frequency, and phase) and uncertainty-aware estimation. Under external vibration conditions, the proposed method demonstrates superior stability compared to conventional approaches, achieving a maximum error reduction of 6.14%. Experimental results show that residual uncertainty is maintained within 5.51% (with a minimum error of 0.6%), the angular resolution of the scanning trajectory is preserved at high-precision level of θ=0.1497± 1.45%. The Root Mean Square Error (RMSE) of the correction algorithm is reduced by up to 5.46% relative to traditional methods, thereby fulfilling real-time processing requirements. Through theoretical modeling and validation on a mobile robot platform, the proposed approach exhibits strong anti-interference performance across varying levels of external vibration. The integration of dynamic adaptive calibration and uncertainty-aware estimation effectively addresses the core challenges in vibration-resilient LiDAR measurement systems, advancing applications in autonomous driving and intelligent robotic navigation.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Adaptive Dynamic Measurement, Trajectory Correction, and Error Evaluation Method in MEMS LiDAR System
In MEMS LiDAR systems, external mechanical disturbances can lead to abnormal trajectory deformations and incoherent 2D point cloud sampling artifacts. To address these challenges, this study proposes a novel measurement framework that enables real-time suppression of trajectory errors through dynamic, adaptive adjustment of scanning parameters (amplitude, frequency, and phase) and uncertainty-aware estimation. Under external vibration conditions, the proposed method demonstrates superior stability compared to conventional approaches, achieving a maximum error reduction of 6.14%. Experimental results show that residual uncertainty is maintained within 5.51% (with a minimum error of 0.6%), the angular resolution of the scanning trajectory is preserved at high-precision level of θ=0.1497± 1.45%. The Root Mean Square Error (RMSE) of the correction algorithm is reduced by up to 5.46% relative to traditional methods, thereby fulfilling real-time processing requirements. Through theoretical modeling and validation on a mobile robot platform, the proposed approach exhibits strong anti-interference performance across varying levels of external vibration. The integration of dynamic adaptive calibration and uncertainty-aware estimation effectively addresses the core challenges in vibration-resilient LiDAR measurement systems, advancing applications in autonomous driving and intelligent robotic navigation.