Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chanyong Park has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microfluidic Molecular Diagnostic Chips: Functional Modules, Integration Strategies, and Emerging Applications

    by Donghoon Koo, Egor Kokin, Sangyul Baik, Chanyong Park, Minji Kim, Jeongmin Kim, Ryungeun Song, Hosub Lim

    Microfluidic molecular diagnostic chips are redefining point‐of‐care testing by integrating the entire analytical workflow spanning from sample preparation to result detection into a single, compact platform. This comprehensive review systematically examines five essential functional modules—mixing, fluid actuation, reagent storage, separation, and reaction chambers—that underpin integrated lab‐on‐a‐chip systems. For each module, the underlying physical principles and representative technologies are critically analyzed with respect to performance metrics (e.g., efficiency and throughput) and structural complexity. By elucidating how microscale transport phenomena, including laminar flow control, efficient heat and mass transfer, and precise reagent manipulation, enable the automation of biological assays, this review clarifies the diagnostic capabilities achievable on a chip, including nucleic acid amplification, immunoassays, and label‐free molecular sensing. Emerging trends in modular design, scalable fabrication methods, and intelligent autonomous operation are discussed as critical drivers for next‐generation sample‐to‐answer systems. Overall, this review provides a comprehensive, application‐oriented framework to guide the development of portable, intelligent, and clinically deployable molecular diagnostic platforms.

  • Development of a fully automated sample-to-answer system for rapid molecular detection of pathogens in whole blood

    by Chanyong Park, Seoyeon Bae, Min Seok Seo, Changha Woo, Seongbo Shim, Joonho Seo, Hosub Lim, Yoochan Hong, Jongsu Yun, Ohwon Kwon, et al.

  • Miniaturized volatile organic compound sensor platform for the real-time monitoring of bacterial growth and antibiotic susceptibility

    by Chanyong Park, Dongju Ha, Seoyeon Bae, Soo-Hwan Jeong, Sangmin Jeon, Yoochan Hong, Ohwon Kwon, Dongkyu Lee


  • Efficient separation of large particles and giant cancer cells using an isosceles trapezoidal spiral microchannel

    by Chanyong Park, Wanyoung Lim, Ryungeun Song, Jeonghun Han, Daeun You, Sangmin Kim, Jeong Eon Lee, Danny van Noort, Carl-Fredrik Mandenius, Jinkee Lee, et al.

    Polyploid giant cancer cells (PGCCs) contribute to the genetic heterogeneity and evolutionary dynamics of tumors. Their size, however, complicates their isolation from mainstream tumor cell populations. Standard techniques like fluorescence-activated cell sorting (FACS) rely on fluorescent labeling, introducing potential challenges in subsequent PGCC analyses. In response, we developed the Isosceles Trapezoidal Spiral Microchannel (ITSμC), a microfluidic device optimizing the Dean drag force (FD) and exploiting uniform vortices for enhanced separation. Numerical simulations highlighted ITSμC's advantage in producing robust FD compared to rectangular and standard trapezoidal channels. Empirical results confirmed its ability to segregate larger polystyrene (PS) particles (avg. diameter: 50 μm) toward the inner wall, while directing smaller ones (avg. diameter: 23 μm) outward. Utilizing ITSμC, we efficiently isolated PGCCs from doxorubicin-resistant triple-negative breast cancer (DOXR-TNBC) and patient-derived cancer (PDC) cells, achieving outstanding purity, yield, and viability rates (all greater than 90%). This precision was accomplished without fluorescent markers, and the versatility of ITSμC suggests its potential in differentiating a wide range of heterogeneous cell populations.


  • Open Access

    Enhanced Luminescent Detection of Circulating Tumor Cells by a 3D Printed Immunomagnetic Concentrator

    by Chanyong Park, Abdurhaman Teyib Abafogi, Dinesh Veeran Ponnuvelu, Ilchan Song, Kisung Ko, Sungsu Park

    Circulating tumor cells (CTCs) are an indicator of metastatic progression and relapse. Since non-CTC cells such as red blood cells outnumber CTCs in the blood, the separation and enrichment of CTCs is key to improving their detection sensitivity. The ATP luminescence assay can measure intracellular ATP to detect cells quickly but has not yet been used for CTC detection in the blood because extracellular ATP in the blood, derived from non-CTCs, interferes with the measurement. Herein, we report on the improvement of the ATP luminescence assay for the detection of CTCs by separating and concentrating CTCs in the blood using a 3D printed immunomagnetic concentrator (3DPIC). Because of its high-aspect-ratio structure and resistance to high flow rates, 3DPIC allows cancer cells in 10 mL to be concentrated 100 times within minutes. This enables the ATP luminescence assay to detect as low as 10 cells in blood, thereby being about 10 times more sensitive than when commercial kits are used for CTC concentration. This is the first time that the ATP luminescence assay was used for the detection of cancer cells in blood. These results demonstrate the feasibility of 3DPIC as a concentrator to improve the detection limit of the ATP luminescence assay for the detection of CTCs.


  • Open Access

    Probing mechanobiological role of filamin A in migration and invasion of human U87 glioblastoma cells using submicron soft pillars

    by Abdurazak Aman Ketebo, Chanyong Park, Jaewon Kim, Myeongjun Jun, Sungsu Park

    Filamin A (FLNa) belongs to an actin-binding protein family in binding and cross-linking actin filaments into a three-dimensional structure. However, little attention has been given to its mechanobiological role in cancer cells. Here, we quantitatively investigated the role of FLNa by analyzing the following parameters in negative control (NC) and FLNa-knockdown (KD) U87 glioma cells using submicron pillars (900 nm diameter and 2 μm height): traction force (TF), rigidity sensing ability, cell aspect ratio, migration speed, and invasiveness. During the initial phase of cell adhesion (< 1 h), FLNa-KD cells polarized more slowly than did NC cells, which can be explained by the loss of rigidity sensing in FLNa-KD cells. The higher motility of FLNa-KD cells relative to NC cells can be explained by the high TF exerted by FLNa-KD cells when compared to NC cells, while the higher invasiveness of FLNa-KD cells relative to NC cells can be explained by a greater number of filopodia in FLNa-KD cells than in NC cells. Our results suggest that FLNa plays important roles in suppressing motility and invasiveness of U87 cells.


  • Open Access

    Enhanced Sensing Behavior of Three-Dimensional Microfluidic Paper-Based Analytical Devices (3D-μPADs) with Evaporation-Free Enclosed Channels for Point-of-Care Testing

    by Jaehyung Jeon, Chanyong Park, Dinesh Veeran Ponnuvelu, Sungsu Park

    Despite the potential in fabrication of microfluidic paper-based analytical devices (μPADs) for point-of-care testing (POCT) kits, the development of simple, accurate, and rapid devices with higher sensitivity remains challenging. Here, we report a novel method for 3D-μPAD fabrication with enclosed channels using vat photopolymerization to avoid fluid evaporation. In detail, height of the enclosed channels was adjusted from 0.3 to 0.17 mm by varying the UV exposure time from 1 to 4 s for the top barrier, whereas the exposure time for the bottom and side barriers was fixed. As a result, sample flow in the enclosed channels of 3D-μPADs showed lesser wicking speed with very scant evaporation compared to that in the hemi channels in the 3D-μPADs. The stoppage of evaporation in the enclosed channels significantly improved the gray intensity and uniformity in the detection zone of the 3D-μPADs, resulting in as low as 0.3 mM glucose detection. Thus 3D-μPADs with enclosed channels showed enhanced sensitivity compared to the 3D-μPADs with hemi channels when dealing with a small volume sample. Our work provides a new insight into 3D-μPAD design with enclosed channels, which redefines the methodology in 3D printing.


  • Open Access

    Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers with a Smartphone

    by Seung Ho Baek, Chanyong Park, Jaehyung Jeon, Sungsu Park

    Paper-based microfluidic analysis devices (μPADs) have attracted attention as a cost-effective platform for point-of-care testing (POCT), food safety, and environmental monitoring. Recently, three-dimensional (3D)-μPADs have been developed to improve the performance of μPADs. For accurate diagnosis of diseases, however, 3D-μPADs need to be developed to simultaneously detect multiple biomarkers. Here, we report a 3D-μPADs platform for the detection of multiple biomarkers that can be analyzed and diagnosed with a smartphone. The 3D-μPADs were fabricated using a 3D digital light processing printer and consisted of a sample reservoir (300 µL) connected to 24 detection zones (of 4 mm in diameter) through eight microchannels (of 2 mm in width). With the smartphone application, eight different biomarkers related to various diseases were detectable in concentrations ranging from normal to abnormal conditions: glucose (0–20 mmol/L), cholesterol (0–10 mmol/L), albumin (0–7 g/dL), alkaline phosphatase (0–800 U/L), creatinine (0–500 µmol/L), aspartate aminotransferase (0–800 U/L), alanine aminotransferase (0–1000 U/L), and urea nitrogen (0–7.2 mmol/L). These results suggest that 3D-µPADs can be used as a POCT platform for simultaneous detection of multiple biomarkers.


  • Open Access

    Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers With a Smartphone

    by Seung Ho Baek, Chanyong Park, Jaehyung Jeon, Sungsu Park

    Paper-based microfluidic analysis devices (μPADs) have attracted attention as a cost-effective platform for point-of-care testing (POCT), food safety, and environmental monitoring. Recently, three-dimensional (3D)-μPADs have been developed to improve the performance of μPADs. For accurate diagnosis of diseases, however, 3D-μPADs need to be developed to simultaneously detect multiple biomarkers. Here, we report a 3D-μPADs platform for the detection of multiple biomarkers that can be analyzed and diagnosed with a smartphone. The 3D-μPADs were fabricated using a 3D digital light processing printer and consisted of a sample reservoir (300 µL) connected to 24 detection zones (of 4 mm in diameter) through 8 microchannels (of 2 mm in width). With the smartphone application, eight different biomarkers related to various diseases were detectable in concentrations ranging from normal to abnormal conditions: glucose (0–20 mmol/L), cholesterol (0–10 mmol/L), albumin (0–7 g/dL), alkaline phosphatase (0–800 U/L), creatinine (0–500 µmol/L), aspartate aminotransferase (0–800 U/L), alanine aminotransferase (0–1000 U/L), and urea nitrogen (0–7.2 mmol/L). These results suggest that 3D-µPADs can be used as a POCT platform for simultaneous detection of multiple biomarkers.


  • Three-Dimensional Paper-Based Microfluidic Analytical Devices Integrated with a Plasma Separation Membrane for the Detection of Biomarkers in Whole Blood

    by Chanyong Park, Hong-Rae Kim, Soo-Kyung Kim, In-Kyung Jeong, Jae-Chul Pyun, Sungsu Park

    Paper-based microfluidic analytical devices (μPADs) have recently attracted attention as a point-of-care (POC) test kit because of their low cost, and non-requirement for external forces. To directly detect biomarkers in whole blood, however, they need to be assembled with a filter such as a plasma separation membrane (PSM) because the color of the blood cells interferes with the colorimetric assay. However, this assembly process is rather complicated and cumbersome, and the fluid does not uniformly move to the detection zone when the adhesion between the paper and PSM is not perfect. In this study, we report a simple 3D printing method for fabricating PSM-integrated 3D-μPADs made of plastics without the need for additional assembly. In detail, PSM was coated with parylene C to prevent its dissolution from organic solvent during 3D printing. Then, the coated PSM was superimposed on the paper. Detection zones and a reservoir were printed on the paper and PSM via liquid photopolymerization, using a digital light processing (DLP) printer. The limit of detection (LOD) of the PSM-integrated 3D-μPADs for glucose in whole blood was 0.3 mM and these devices demonstrated clinically relevant performance on diabetes patient blood samples. Our 3D-μPADs can also simultaneously detect multiple metabolic disease markers including glucose, cholesterol, and triglycerides in whole blood. Our results suggest that our printing method is useful for fabricating 3D-μPADs integrated with PSM for direct detection of biomarkers in whole blood.