Alireza Karimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alireza Karimi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- J. Crawford Downs
Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, United States
7 shared publications - Reza Razaghi
Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, United States
6 shared publications Reza Razaghi
Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, 1670 University Boulevard, VH 372B, Birmingham, AL 35294, USA
4 shared publications- Seyed Mohammadali Rahmati
Department of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA
4 shared publications - Ted S. Acott
Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, United States; Department Chemical Physiology & Biochemistry, School of Medicine, Oregon Health & Science University, Portland, OR, United States
4 shared publications - Christopher A. Girkin
From the Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology (G.G., S.M., T.N., L.M.Z., R.N.W.), University of California San Diego, La Jolla, California, USA
3 shared publications
Latest Publications
- Open Access
Modeling the Endothelial Glycocalyx Layer in the Human Conventional Aqueous Outflow Pathway
A layer of proteoglycans and glycoproteins known as glycocalyx covers the surface of the trabecular meshwork (TM), juxtacanalicular tissue (JCT), and Schlemm’s canal (SC) inner wall of the conventional aqueous outflow pathway in the eye. This has been shown to play a role in the mechanotransduction of fluid shear stress and in the regulation of the outflow resistance. The outflow resistance in the conventional outflow pathway is the main determinant of the intraocular pressure (IOP) through an active, two-way, fluid–structure interaction coupling between the outflow tissues and aqueous humor. A 3D microstructural finite element (FE) model of a healthy human eye TM/JCT/SC complex with interspersed aqueous humor was constructed. A very thin charged double layer that represents the endothelial glycocalyx layer covered the surface of the elastic outflow tissues. The aqueous humor was modeled as electroosmotic flow that is charged when it is in contact with the outflow tissues. The electrical–fluid–structure interaction (EFSI) method was used to couple the charged double layer (glycocalyx), fluid (aqueous humor), and solid (outflow tissues). When the IOP was elevated to 15 mmHg, the maximum aqueous humor velocity in the EFSI model was decreased by 2.35 mm/s (9%) compared to the fluid–structure interaction (FSI) model. The charge or electricity in the living human conventional outflow pathway generated by the charged endothelial glycocalyx layer plays a minor biomechanical role in the resultant stresses and strains as well as the hydrodynamics of the aqueous humor.
Open AccessModeling the Endothelial Glycocalyx Layer in the Human Conventional Aqueous Outflow Pathway
A layer of proteoglycans and glycoproteins known as glycocalyx covers the surface of the trabecular meshwork (TM), juxtacanalicular tissue (JCT), and Schlemm’s canal (SC) inner wall of the conventional aqueous outflow pathway in the eye. This has been shown to play a role in the mechanotransduction of fluid shear stress and in the regulation of the outflow resistance. The outflow resistance in the conventional outflow pathway is the main determinant of the intraocular pressure (IOP) through an active, two-way, fluid–structure interaction coupling between the outflow tissues and aqueous humor. A 3D microstructural finite element (FE) model of a healthy human eye TM/JCT/SC complex with interspersed aqueous humor was constructed. A very thin charged double layer that represents the endothelial glycocalyx layer covered the surface of the elastic outflow tissues. The aqueous humor was modeled as electroosmotic flow that is charged when it is in contact with the outflow tissues. The electrical–fluid–structure interaction (EFSI) method was used to couple the charged double layer (glycocalyx), fluid (aqueous humor), and solid (outflow tissues). When the IOP was elevated to 15 mmHg, the maximum aqueous humor velocity in the EFSI model was decreased by 2.35 mm/s (9%) compared to the fluid–structure interaction (FSI) model. The charge or electricity in the living human conventional outflow pathway generated by the charged endothelial glycocalyx layer plays a minor biomechanical role in the resultant stresses and strains as well as the hydrodynamics of the aqueous humor.
- Open Access
- 10 November 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (11) , 672
The Effect of Intraocular Pressure Load Boundary on the Biomechanics of the Human Conventional Aqueous Outflow Pathway
Background: Aqueous humor outflow resistance in the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm’s canal (SC) endothelium of the conventional outflow pathway actively contribute to intraocular pressure (IOP) regulation. Outflow resistance is actively affected by the dynamic outflow pressure gradient across the TM, JCT, and SC inner wall tissues. The resistance effect implies the presence of a fluid–structure interaction (FSI) coupling between the outflow tissues and the aqueous humor. However, the biomechanical interactions between viscoelastic outflow tissues and aqueous humor dynamics are largely unknown. Methods: A 3D microstructural finite element (FE) model of a healthy human eye TM/JCT/SC complex was constructed with elastic and viscoelastic material properties for the bulk extracellular matrix and embedded elastic cable elements. The FE models were subjected to both idealized and a physiologic IOP load boundary using the FSI method. Results: The elastic material model for both the idealized and physiologic IOP load boundary at equal IOPs showed similar stresses and strains in the outflow tissues as well as pressure in the aqueous humor. However, outflow tissues with viscoelastic material properties were sensitive to the IOP load rate, resulting in different mechanical and hydrodynamic responses in the tissues and aqueous humor. Conclusions: Transient IOP fluctuations may cause a relatively large IOP difference of ~20 mmHg in a very short time frame of ~0.1 s, resulting in a rate stiffening in the outflow tissues. Rate stiffening reduces strains and causes a rate-dependent pressure gradient across the outflow tissues. Thus, the results suggest it is necessary to use a viscoelastic material model in outflow tissues that includes the important role of IOP load rate.
- 10 November 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (11) , 672
Open AccessThe Effect of Intraocular Pressure Load Boundary on the Biomechanics of the Human Conventional Aqueous Outflow Pathway
Background: Aqueous humor outflow resistance in the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm’s canal (SC) endothelium of the conventional outflow pathway actively contribute to intraocular pressure (IOP) regulation. Outflow resistance is actively affected by the dynamic outflow pressure gradient across the TM, JCT, and SC inner wall tissues. The resistance effect implies the presence of a fluid–structure interaction (FSI) coupling between the outflow tissues and the aqueous humor. However, the biomechanical interactions between viscoelastic outflow tissues and aqueous humor dynamics are largely unknown. Methods: A 3D microstructural finite element (FE) model of a healthy human eye TM/JCT/SC complex was constructed with elastic and viscoelastic material properties for the bulk extracellular matrix and embedded elastic cable elements. The FE models were subjected to both idealized and a physiologic IOP load boundary using the FSI method. Results: The elastic material model for both the idealized and physiologic IOP load boundary at equal IOPs showed similar stresses and strains in the outflow tissues as well as pressure in the aqueous humor. However, outflow tissues with viscoelastic material properties were sensitive to the IOP load rate, resulting in different mechanical and hydrodynamic responses in the tissues and aqueous humor. Conclusions: Transient IOP fluctuations may cause a relatively large IOP difference of ~20 mmHg in a very short time frame of ~0.1 s, resulting in a rate stiffening in the outflow tissues. Rate stiffening reduces strains and causes a rate-dependent pressure gradient across the outflow tissues. Thus, the results suggest it is necessary to use a viscoelastic material model in outflow tissues that includes the important role of IOP load rate.
- Open Access
- 13 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (20) , 6049
Viscoelastic Biomechanical Properties of the Conventional Aqueous Outflow Pathway Tissues in Healthy and Glaucoma Human Eyes
Background: Although the tissues comprising the ocular conventional outflow pathway have shown strong viscoelastic mechanical response to aqueous humor pressure dynamics, the viscoelastic mechanical properties of the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm’s canal (SC) inner wall are largely unknown. Methods: A quadrant of the anterior segment from two human donor eyes at low- and high-flow (LF and HF) outflow regions was pressurized and imaged using optical coherence tomography (OCT). A finite element (FE) model of the TM, the adjacent JCT, and the SC inner wall was constructed and viscoelastic beam elements were distributed in the extracellular matrix (ECM) of the TM and JCT to represent anisotropic collagen. An inverse FE-optimization algorithm was used to calculate the viscoelastic properties of the ECM/beam elements such that the TM/JCT/SC model and OCT imaging data best matched over time. Results: The ECM of the glaucoma tissues showed significantly larger time-dependent shear moduli compared to the heathy tissues. Significantly larger shear moduli were also observed in the LF regions of both the healthy and glaucoma eyes compared to the HF regions. Conclusions: The outflow tissues in both glaucoma eyes and HF regions are stiffer and less able to respond to dynamic IOP.
- 13 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (20) , 6049
Open AccessViscoelastic Biomechanical Properties of the Conventional Aqueous Outflow Pathway Tissues in Healthy and Glaucoma Human Eyes
Background: Although the tissues comprising the ocular conventional outflow pathway have shown strong viscoelastic mechanical response to aqueous humor pressure dynamics, the viscoelastic mechanical properties of the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm’s canal (SC) inner wall are largely unknown. Methods: A quadrant of the anterior segment from two human donor eyes at low- and high-flow (LF and HF) outflow regions was pressurized and imaged using optical coherence tomography (OCT). A finite element (FE) model of the TM, the adjacent JCT, and the SC inner wall was constructed and viscoelastic beam elements were distributed in the extracellular matrix (ECM) of the TM and JCT to represent anisotropic collagen. An inverse FE-optimization algorithm was used to calculate the viscoelastic properties of the ECM/beam elements such that the TM/JCT/SC model and OCT imaging data best matched over time. Results: The ECM of the glaucoma tissues showed significantly larger time-dependent shear moduli compared to the heathy tissues. Significantly larger shear moduli were also observed in the LF regions of both the healthy and glaucoma eyes compared to the HF regions. Conclusions: The outflow tissues in both glaucoma eyes and HF regions are stiffer and less able to respond to dynamic IOP.
- Open Access
Interaction of the Blood Components with Ascending Thoracic Aortic Aneurysm Wall: Biomechanical and Fluid Analyses
Background: Ascending thoracic aortic aneurysm (ATAA) is an asymptomatic localized dilation of the aorta that is prone to rupture with a high rate of mortality. While diameter is the main risk factor for rupture assessment, it has been shown that the peak wall stress from finite element (FE) simulations may contribute to refinement of clinical decisions. In FE simulations, the intraluminal boundary condition is a single-phase blood flow that interacts with the thoracic aorta (TA). However, the blood is consisted of red blood cells (RBCs), white blood cells (WBCs), and plasma that interacts with the TA wall, so it may affect the resultant stresses and strains in the TA, as well as hemodynamics of the blood. Methods: In this study, discrete elements were distributed in the TA lumen to represent the blood components and mechanically coupled using fluid–structure interaction (FSI). Healthy and aneurysmal human TA tissues were subjected to axial and circumferential tensile loadings, and the hyperelastic mechanical properties were assigned to the TA and ATAA FE models. Results: The ATAA showed larger tensile and shear stresses but smaller fluid velocity compared to the ATA. The blood components experienced smaller shear stress in interaction with the ATAA wall compared to TA. The computational fluid dynamics showed smaller blood velocity and wall shear stress compared to the FSI. Conclusions: This study is a first proof of concept, and future investigations will aim at validating the novel methodology to derive a more reliable ATAA rupture risk assessment considering the interaction of the blood components with the TA wall.
Open AccessInteraction of the Blood Components with Ascending Thoracic Aortic Aneurysm Wall: Biomechanical and Fluid Analyses
Background: Ascending thoracic aortic aneurysm (ATAA) is an asymptomatic localized dilation of the aorta that is prone to rupture with a high rate of mortality. While diameter is the main risk factor for rupture assessment, it has been shown that the peak wall stress from finite element (FE) simulations may contribute to refinement of clinical decisions. In FE simulations, the intraluminal boundary condition is a single-phase blood flow that interacts with the thoracic aorta (TA). However, the blood is consisted of red blood cells (RBCs), white blood cells (WBCs), and plasma that interacts with the TA wall, so it may affect the resultant stresses and strains in the TA, as well as hemodynamics of the blood. Methods: In this study, discrete elements were distributed in the TA lumen to represent the blood components and mechanically coupled using fluid–structure interaction (FSI). Healthy and aneurysmal human TA tissues were subjected to axial and circumferential tensile loadings, and the hyperelastic mechanical properties were assigned to the TA and ATAA FE models. Results: The ATAA showed larger tensile and shear stresses but smaller fluid velocity compared to the ATA. The blood components experienced smaller shear stress in interaction with the ATAA wall compared to TA. The computational fluid dynamics showed smaller blood velocity and wall shear stress compared to the FSI. Conclusions: This study is a first proof of concept, and future investigations will aim at validating the novel methodology to derive a more reliable ATAA rupture risk assessment considering the interaction of the blood components with the TA wall.
- Open Access
The Design and Control of a Footplate-Based Gait Robo-Assisted System for Lower Limb Actuator
Stroke causes disability in the lower-limb symmetry gait pattern in affected patients. The patients would not be able to regain their usual walking ability independently unless they benefit from rehabilitation therapies. Footplate-based gait robo-assisted systems can help patients to conduct effective training/exercising while tracking their progress of recovery and can dramatically reduce the clinical labor costs of physiotherapy. In the sense of simulation and not the design of the mechanical structure, this study aims to perform a combination of dynamic and control simulation of a five degrees-of-freedom footplate-based gait robo-assisted system established according to the Stewart platform structure for use in lower limb rehabilitation of stroke patients. The effectiveness and performance of the proposed mechanism were assessed through a clinical gait pattern of a healthy male individual. The proposed robo-assisted system enables the simulation of the hip and knee flexion/extension as well as the ankle dorsiflexion/plantar flexion of stroke patients to reproduce their typical symmetry gait pattern. The results were interpreted as the dynamic movement characteristics of the right and left thigh, leg, and foot compared to the clinical gait pattern with a mean percentage error of 6.70% to show the effectiveness and accuracy of the developed robo-assisted system for lower limb actuation in the simulation process.
Open AccessThe Design and Control of a Footplate-Based Gait Robo-Assisted System for Lower Limb Actuator
Stroke causes disability in the lower-limb symmetry gait pattern in affected patients. The patients would not be able to regain their usual walking ability independently unless they benefit from rehabilitation therapies. Footplate-based gait robo-assisted systems can help patients to conduct effective training/exercising while tracking their progress of recovery and can dramatically reduce the clinical labor costs of physiotherapy. In the sense of simulation and not the design of the mechanical structure, this study aims to perform a combination of dynamic and control simulation of a five degrees-of-freedom footplate-based gait robo-assisted system established according to the Stewart platform structure for use in lower limb rehabilitation of stroke patients. The effectiveness and performance of the proposed mechanism were assessed through a clinical gait pattern of a healthy male individual. The proposed robo-assisted system enables the simulation of the hip and knee flexion/extension as well as the ankle dorsiflexion/plantar flexion of stroke patients to reproduce their typical symmetry gait pattern. The results were interpreted as the dynamic movement characteristics of the right and left thigh, leg, and foot compared to the clinical gait pattern with a mean percentage error of 6.70% to show the effectiveness and accuracy of the developed robo-assisted system for lower limb actuation in the simulation process.
- 31 May 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (6) , 660-672
A position- and time-dependent pressure profile to model viscoelastic mechanical behavior of the brain tissue due to tumor growth
This study proposed a computational framework to calculate the resultant position- and time-dependent pressure profile on the brain tissue due to tumor growth. A finite element (FE) patch of the brain tissue was constructed and an inverse dynamic FE-optimization algorithm was used to calculate its viscoelastic mechanical properties under compressive uniaxial loading. Two patient-specific post-tumor resection FE models were input to the FE-optimization algorithm to calculate the optimized 3(rd)-order position-dependent and normal distribution time-dependent pressure profile parameters. The optimized viscoelastic material properties, the most suitable simulation time, and the optimized 3(rd)-order position- and -time-dependent pressure profiles were calculated.
- 31 May 2022
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 26 (6) , 660-672
A position- and time-dependent pressure profile to model viscoelastic mechanical behavior of the brain tissue due to tumor growth
This study proposed a computational framework to calculate the resultant position- and time-dependent pressure profile on the brain tissue due to tumor growth. A finite element (FE) patch of the brain tissue was constructed and an inverse dynamic FE-optimization algorithm was used to calculate its viscoelastic mechanical properties under compressive uniaxial loading. Two patient-specific post-tumor resection FE models were input to the FE-optimization algorithm to calculate the optimized 3(rd)-order position-dependent and normal distribution time-dependent pressure profile parameters. The optimized viscoelastic material properties, the most suitable simulation time, and the optimized 3(rd)-order position- and -time-dependent pressure profiles were calculated.
- 29 May 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 221, 106922
Modeling the biomechanics of the conventional aqueous outflow pathway microstructure in the human eye
- 29 May 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 221, 106922
Modeling the biomechanics of the conventional aqueous outflow pathway microstructure in the human eye
- 27 May 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 221, 106921
Biomechanics of human trabecular meshwork in healthy and glaucoma eyes via dynamic Schlemm's canal pressurization
- 27 May 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 221, 106921
Biomechanics of human trabecular meshwork in healthy and glaucoma eyes via dynamic Schlemm's canal pressurization
- 4 January 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 215, 106618
Finite element modeling of the complex anisotropic mechanical behavior of the human sclera and pia mater
- 4 January 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 215, 106618
Finite element modeling of the complex anisotropic mechanical behavior of the human sclera and pia mater