Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomiharu Yamaguchi has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Temporal and Spectral Impedance Myography: Visualization of Dynamic Electrical Properties in Forearm Tissue During Wrist Movements

    by Tomiharu Yamaguchi, Akihiko Tsukahara, Yuho Tanaka, Akinori Ueno

    The recently proposed short-time impedance spectroscopy (short-time IS) measures impedance spectra with high temporal resolution using a nonsinusoidal mode-switching oscillator. With a view to application for muscular disease diagnosis and human-machine interaction, this study presents the temporal and spectral impedance myography using the short-time IS system. We applied the proposed system to the measurement of human forearm impedance and analyzed impedance changes during wrist motion. The forearm's impedance at 40 frequency points was measured by our developed system. The forearm's rapid impedance response during wrist motion was captured with a high temporal resolution of about 0.5 ms, displaying the impedance magnitude and phase angle change as a color map. Furthermore, we experimentally and theoretically demonstrated that difference and differential Cole-Cole plots reduced skin impedance effects and produced a characteristic curve corresponding to wrist motion, even with two-terminal measurement. We anticipate that the IS system and visualization method will be beneficial for myoelectric control in prosthetic hands and noninvasive muscle disease diagnosis.


  • Open Access

    Temporal and Spectral Impedance Myography: Visualization of Dynamic Electrical Properties in Forearm Tissue during Wrist Movements

    by Tomiharu Yamaguchi, Akihiko Tsukahara, Yuho Tanaka, Akinori Ueno

    The recently proposed short-time impedance spectroscopy (short-time IS) measures impedance spectra with high temporal resolution using nonsinusoidal oscillator signals. This study applied the short-time IS system to biological tissue impedance measurement during muscle activity. The system measured the temporal impedance spectrum of the human forearm and analyzed impedance changes during wrist motion. The IS system captured highly reproducible, frequency-dependent impedance changes when the wrist moved up and down. The forearm's impedance response during wrist motion was visualized with a high temporal resolution of about 0.5 ms, displaying the impedance magnitude and phase angle change as a color map. The short-time IS system's mode-switching mechanism enables rapid impedance measurement at 40 frequencies, forming smooth Cole-Cole plots with high temporal resolution. While muscle tissue impedance measurement is typically affected by skin tissue's high impedance, we found that difference and differential Cole-Cole plots reduced skin impedance effects and produced a characteristic curve corresponding to wrist motion, even with two-terminal measurement. We theoretically confirmed that the difference and differential Cole-Cole plots represent a reasonable muscle tissue impedance variation. This characteristic curve is compatible with machine learning techniques like pattern recognition. We anticipate that the IS system and visualization method will be beneficial for myoelectric control in prosthetic hands and noninvasive muscle disease diagnosis.

  • Open Access

    FPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation

    by Akihiko Tsukahara, Tomiharu Yamaguchi, Yuho Tanaka, Akinori Ueno

    In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has the capability to acquire frequency spectra of complex electrical impedance sequentially on a millisecond timescale. Even when the measured object with time-varying unknown resistance Rx is capacitively coupled with the measurement electrodes with time-varying unknown capacitance Cx, CIS can be measured. As a proof of concept, this study aimed to develop a prototype that implemented the novel algorithm of CIS and circuit parameter estimation to verify whether the frequency spectra and circuit parameters could be obtained in milliseconds and whether time-varying impedance could be measured. This study proposes a dedicated processor that was implemented as field-programmable gate arrays to perform CIS, estimate Rx and Cx, and their digital-to-analog conversions at a certain time, and to repeat them continually. The proposed processor executed the entire sequence in the order of milliseconds. Combined with a front-end nonsinusoidal oscillator and interfacing circuits, the processor estimated the fixed Rx and fixed Cx with reasonable accuracy. Additionally, the combined system with the processor succeeded in detecting a quick optical response in the resistance of the cadmium sulfide (CdS) photocell connected in series with a capacitor, and in reading out their resistance and capacitance independently as voltages in real-time.


  • Open Access

    Short-Time Impedance Spectroscopy Using a Mode-Switching Nonsinusoidal Oscillator: Applicability to Biological Tissues and Continuous Measurement

    by Tomiharu Yamaguchi, Emiyu Ogawa, Akinori Ueno

    Herein, we propose an impedance spectroscopy method using a mode-switching nonsinusoidal oscillator and apply this method for measuring the impedance of biological tissues and continuous impedance measurement. To obtain impedance spectra over a wide frequency range, we fabricated a novel nonsinusoidal oscillator incorporating binary counters and analog switches. This oscillator could periodically switch oscillation frequency through the mode switching of the feedback resistor. From the oscillation waveform at each oscillation frequency of this circuit (oscillator), we determined the impedance spectrum of a measured object using the discrete-time Fourier transform. Subsequently, we obtained the broad impedance spectrum of the measured object by merging odd-order harmonic spectral components up to the 19th order for each oscillation frequency. From the measured spectrum, the resistive and capacitive components of the circuit simulating bioimpedance were estimated with high accuracy. Moreover, the proposed method was used to measure the impedance of porcine myocardium; changes in the impedance spectrum of the myocardial tissue due to coagulation could be measured. Furthermore, rapid variations in the resistance value of a CdS photocell could be continuously measured using the proposed method.


  • Open Access

    Capacitive-Coupling Impedance Spectroscopy Using a Non-Sinusoidal Oscillator and Discrete-Time Fourier Transform: An Introductory Study

    by Tomiharu Yamaguchi, Akinori Ueno

    In this study, we propose a new short-time impedance spectroscopy method with the following three features: (1) A frequency spectrum of complex impedance for the measured object can be obtained even when the measuring electrodes are capacitively coupled with the object and the precise capacitance of the coupling is unknown; (2) the spectrum can be obtained from only one cycle of the non-sinusoidal oscillation waveform without sweeping the oscillation frequency; and (3) a front-end measuring circuit can be built, simply and cheaply, without the need for a digital-to-analog (D-A) converter to synthesize elaborate waveforms comprising multiple frequencies. We built the measurement circuit using the proposed method and then measured the complex impedance spectra of 18 resistive elements connected in series with one of three respective capacitive couplings. With this method, each element’s resistance and each coupling’s capacitance were estimated independently and compared with their nominal values. When the coupling capacitance was set to 10 nF or 1.0 nF, estimated errors for the resistive elements in the range of 2.0–10.0 kΩ were less than 5%.


  • Development of QCM humidity sensors using anodized alumina film

    by Nobuo Yamamoto, Tomiharu Yamaguchi, Kazuhiro Hara

    Humidity sensors based on QCM (quartz crystal microbalance) have been developed using an anodized alumina thin‐film as a sensing material. An aluminum thin‐film is deposited on a silver‐coated quartz crystal by electron beam deposition and is anodized in an acid solution. The resultant alumina film is porous. The resonant frequency gradually decreases from 5% to 94% relative humidity (RH) and steeply changes near 100% RH. This result shows that the sensor can be used as a dew‐point sensor as well as a humidity sensor. The response times to the humidity changes from 27% to 59% RH and from 59% to 27% RH are less than 5 s. The sensor shows reversible response to some gases such as ethanol, toluene, and acetone vapors in addition to airborne particles such as pollen.


  • Novel Conductometric Sensor for Detecting Pollen Using Semiconductor Thin-Film

    by Ren Horiuchi, Tomiharu Yamaguchi, Kazuhiro Hara

    This paper presents a novel conductometric sensor for detecting organic airborne particles such as pollen. The sensing film was composed of a ZnO-based film that was sensitive to organic airborne particles. It was made by the integrated circuit fabrication process and thin-film technology. The resistance of the sensor rapidly decreased after the adhesion of a grain of pollen on the surface and then gradually recovered to the original value. Our study revealed that the magnitude of the resistance decrease depended on the particle size. The results imply the possibility of identification of the kind of pollen from the magnitude of the resistance change. Our study also revealed that the cross sensitivity of the sensor using ZnO-based film to gas was lower than that of the one using SnO 2 -based film. In principle, the resistance change results from the reaction of pollen with chemisorbed oxygen; carbon and hydrogen atoms contained in pollen react with chemisorbed oxygen species such as O − , emitting captured electrons into the semiconductor thin film and thus decreasing the sensor resistance. Thus, the developed sensor can be used as a small, light-weighted, and inexpensive monitoring device of pollen.

  • WO3-based Hydrogen Gas Sensors Using Stacked Thin Films with Interspace

    by Tatsuro Yamada, Tomiharu Yamaguchi, Kazuhiro Hara

    Hydrogen gas sensors using stacked WO 3 -based films with interspace has been demonstrated. In order to enhance hydrogen sensitivity and selectivity, porous WO 3 +TiO 2 sensing films are deposited and stacked by RF sputtering and thermal treatment. Additionally, interspaces between the sensing films were fabricated by sacrificial layer etching of SiO 2 , which allowed hydrogen molecules to adsorb on all WO 3 +TiO 2 surfaces. Without using any noble metal catalysts, a four-stacked WO 3 +TiO 2 hydrogen sensor was highly sensitive to hydrogen ranging from 10 ppm to 3000 ppm. The response and recovery times of the sensor to hydrogen of 1000 ppm were 35 s and 30 s, respectively. Moreover, the stacked structure with interspace suppressed the response of the sensor to various combustible gases, such as isobutane, methane, ethylene, and propane. Because the sensitivity of the sensor was more stable after an aging process, the proposed sensor is suitable for a continuous and long-term monitoring of a hydrogen gas leakage.


  • Study on NH3 Gas Sensors using a WO3-based Multiple-layered Thin Film with Pt Catalyst

    by Tsubasa Morita, Koji Sano, Tomiharu Yamaguchi, Kazuhiro Hara

    NH3 gas is a poisonous substance that adversely affects the environment and humans. A low level NH3 is created by human bodies and emitted as a component of urine and exhaled breath. Therefore, the detection of NH3 gas is important to monitor human health conditions. A novel WO3 multiple-layered thin film NH3 sensor using Pt catalyst has been developed in this study. WO3 thin film coated with Pt nanoparticles successfully improves the sensitivity to NH3 gas. Furthermore, WO3 multiple-layered thin film with an interspace has the effect of enhancing the sensitivity and lowering the optimum operating temperature. The developed sensor can detect as low as 1 ppm NH3 gas.

  • Semiconductor Thin-film Gas and Smell Sensors using a Face-to-face Type Adsorption and Desorption Layer

    by Daisuke Sasagawa, Ryosuke Kinoshita, Tomiharu Yamaguchi, Kazuhiro Hara

    Semiconductor gas sensors have the drawback of poor gas selectivity, though they are sensitive to a wide variety of gases. A novel thin-film gas sensor with a gas adsorption and desorption part mounted on a rotation mechanism is developed to improve the gas selectivity. Activated carbon doped with noble metal catalyst is used as the adsorbent. The sensor exhibits different response to each isovaleric acid gas, ethanol gas and hydrogen gas after rotating the activated carbon to the place close to the sensing part and being heated by an implemented heater on it. Thus the sensor is able to discriminate the kind of gas by analyzing the sensitivity along with the adsorption and desorption response.