  • An International Position Statement on Practical Approaches for Inpatient Continuous Glucose Monitoring, Insulin Pumps, and Automated Insulin Delivery Systems in Adults

    by Mikkel T. Olsen, Elias K. Spanakis, Hood Thabit, Ketan Dhatariya, Omar G. Mustafa, Parizad Avari, Alistair N. Lumb, Katheleen Dungan, Athena Philis-Tsimikas, Kristen Kulasa, et al.

    There is an urgent and unmet need for a practical clinical guideline addressing the use of continuous glucose monitoring (CGM), insulin pumps, and automated insulin delivery (AID) systems in hospital settings. The goal with this position statement is to facilitate effective and safe use of these devices to improve glycemic management, enhance outcomes, and contribute to standardization efforts in initiating or continuing the use of these devices in hospitals for non–critically ill hospitalized adults. The topics covered include selection criteria for management with diabetes technologies, CGM-derived glycemic metrics and goals for adults with diabetes, insulin titration and administration guidelines, perioperative care, CGM alarm settings for hypoglycemia and hyperglycemia, clinical staff training and workflows, integration of device data with the electronic health record, imaging tests considerations, and discharge planning.


  • Open Access

    An international position statement on practical approaches for inpatient continuous glucose monitoring, insulin pumps and automated insulin delivery systems in adults

    by Mikkel T. Olsen, Elias K. Spanakis, Hood Thabit, Ketan Dhatariya, Omar G. Mustafa, Parizad Avari, Alistair N. Lumb, Katheleen Dungan, Athena Philis-Tsimikas, Kristen Kulasa, et al.

    There is an urgent and unmet need for a practical clinical guideline addressing the use of continuous glucose monitoring (CGM), insulin pumps and automated insulin delivery (AID) systems in hospital settings. The goal with this position statement is to facilitate effective and safe use of these devices to improve glycaemic management, enhance outcomes and contribute to standardisation efforts in initiating or continuing the use of these devices in hospitals for non-critically ill hospitalised adults. The topics covered include selection criteria for management with diabetes technologies, CGM-derived glycaemic metrics and goals for adults with diabetes, insulin titration and administration guidelines, perioperative care, CGM alarm settings for hypoglycaemia and hyperglycaemia, clinical staff training and workflows, integration of device data with the electronic health record, imaging tests considerations and discharge planning. Graphical Abstract

  • Open Access

    Continuous Glucose Monitoring–Guided Insulin Infusion in Critically Ill Patients Promotes Safety, Improves Time Efficiency, and Enhances Provider Satisfaction

    by Erin R. Giovannetti, Rachael O. Lee, Robert L. Thomas, Tamar Wolinsky, Adrianne V. Talbot, Rabia S. Ali, Tricia Santos Cavaiola, Kristen Kulasa, Schafer C. Boeder


  • Open Access

    Accuracy of Factory-Calibrated Continuous Glucose Monitors in Critically Ill Patients Receiving Intravenous Insulin: A Prospective Clinical Trial of Two Leading Systems

    by Gautam Ramesh, Emily Kobayashi, Navyaa Sharma, Amit R. Majithia, Kristen Kulasa, Schafer C. Boeder

    Background: Continuous glucose monitors (CGMs) are increasingly being used to guide glucose management in the hospital. However, uncertainty regarding their accuracy in this setting remains. Methods: We conducted a nonrandomized, open-label, clinically blinded prospective trial of the Dexcom G6 Pro (G6P) and FreeStyle Libre Pro (FLP) in the inpatient setting among critically ill hospitalized patients (n = 40) requiring continuous intravenous insulin infusion. In parallel with CGM data, reference serum (Lab) glucose and point-of-care (POC) glucose values were obtained. On completion of the study, CGM and reference values were analyzed to assess CGM accuracy. Results: A total of 1015 matched G6P-Lab pairs had a mean absolute relative difference (MARD) of 22.7%, 2369 G6P-POC pairs had an MARD of 22.9%, 1006 matched FLP-Lab pairs had an MARD of 25.2%, and 2353 FLP-POC pairs had an MARD of 27.0%. Both CGM systems demonstrated considerable inter-patient variability in sensor accuracy and tended to underestimate glucose in comparison with the reference values. Rarely were low reference values overestimated by either sensor. Conclusions: Factory-calibrated continuous glucose monitors may require accuracy validation and per-patient calibration for inpatient use in critically ill patients.


  • Bridging the Glycemic Gap: Will CMS-Mandated Reporting Improve Hospital Dysglycemia Management?

    by Mihail Zilbermint, Jordan Messler, Camille Frances Stanback, Kristen Kulasa, Andrew P. Demidowich


  • A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials

    by Elias K. Spanakis, Curtiss B. Cook, Kristen Kulasa, Joseph A. Aloi, Lia Bally, Georgia Davis, Kathleen M. Dungan, Rodolfo J. Galindo, Carlos E. Mendez, Francisco J. Pasquel, et al.

    Diabetes Technology Society organized an expert consensus panel to develop metrics for research in the use of continuous glucose monitors (CGMs) in a hospital setting. The experts met virtually in small groups both before and after an April 13, 2023 virtual meeting of the entire panel. The goal of the panel was to develop consensus definitions in anticipation of greater use of CGMs in hospital settings in the future. Establishment of consensus definitions of inpatient analytical metrics will be easier to compare outcomes between studies. Panelists defined terms related to 10 dimensions of measurements related to the use of CGMs including (1) hospital hypoglycemia, (2) hospital hyperglycemia, (3) hospital time in range, (4) hospital glycemic variability, (5) hospital glycemia risk index, (6) accuracy of CGM devices and reference methods for CGMs in the hospital, (7) meaningful time blocks for hospital glycemic goals, (8) hospital CGM data sufficiency, (9) using CGM data for insulin dosing, and (10) miscellaneous factors. The panelists voted on 51 proposed recommendations. Based on the panel vote, 51 recommendations were classified as either strong (43) or mild (8). Additional research is needed on CGM performance in the hospital. This consensus report is intended to support that type of research intended to improve outcomes for hospitalized people with diabetes.


  • Glucometrics: Where Are We Now?

    by Kelly Engle, Grace Bacani, Curtiss B. Cook, Gregory A. Maynard, Jordan Messler, Kristen Kulasa

    Purpose of Review Inpatient glucose data analysis, or glucometrics, has developed alongside the growing emphasis on glycemic control in the hospital. Shortcomings in the initial capabilities for glucometrics have pushed advancements in defining meaningful units of measurement and methods for capturing glucose data. This review addresses the growth in glucometrics and ends with its promising new state. Recent Findings Standardization, allowing for benchmarking and purposeful comparison, has been a goal of the field. The National Quality Foundation glycemic measures and recently enacted Center for Medicare and Medicaid Services (CMS) electronic quality measures for hypo- and hyperglycemia have allowed for improved integration and consistency. Summary Prior systems have culminated in an upcoming measure from the Center for Disease Control and Prevention’s National Healthcare Safety Network. It is poised to create a new gold standard for glucometrics by expanding and refining the CMS metrics, which should empower both local improvement and benchmarking as the program matures.


  • Inpatient Type 1 Diabetes

    by Anna Delfina Giannella, Tricia Santos Cavaiola, Kristen Kulasa

  • Open Access

    Electronic Health Record–Based Decision-Making Support in Inpatient Diabetes Management

    by Johanna E. Gerwer, Grace Bacani, Patricia S. Juang, Kristen Kulasa

    Purpose of Review: This review discusses ways in which the electronic health record (EHR) can offer clinical decision support (CDS) tools for management of inpatient diabetes and hyperglycemia. Recent Findings: The use of electronic order sets can help providers order comprehensive basal bolus insulin regimens that are consistent with current guidelines. Order sets have been shown to reduce insulin errors and hypoglycemia rates. They can also help set glycemic targets, give hemoglobin A1C reminders, guide weight-based dosing, and match insulin regimen to nutritional profile. Glycemic management dashboards allow multiple variables affecting blood glucose to be shown in a single view, which allows for efficient evaluation of glucose trends and adjustment of insulin regimen. With the use glycemic management dashboards, active surveillance and remote management also become feasible. Hypoglycemia prevention and management are another part of inpatient diabetes management that is enhanced by EHR CDS tools. Furthermore, diagnosis and management of diabetic ketoacidosis and hyperglycemia hyperosmolar state are improved with the aid of EHR CDS tools. Summary: The use of EHR CDS tools helps improve the care of patients with diabetes and hyperglycemia in the inpatient hospital setting.


  • Open Access

    Accuracy and Glycemic Efficacy of Continuous Glucose Monitors in Critically Ill COVID-19 Patients: A Retrospective Study

    by Schafer Boeder, Emily Kobayashi, Gautam Ramesh, Brittany Serences, Kristen Kulasa, Amit R. Majithia

    Background: Continuous glucose monitoring (CGM) is approved for insulin dosing decisions in the ambulatory setting, but not currently for inpatients. CGM has the capacity to reduce patient-provider contact in inpatients with coronavirus disease 2019 (COVID-19), thus potentially reducing in hospital virus transmission. However, there are sparse data on the accuracy and efficacy of CGM to titrate insulin doses in inpatients. Methods: Under an emergency use protocol, CGM (Dexcom G6) was used alongside standard point-of-care (POC) glucose measurements in patients critically ill from complications of COVID-19 requiring intravenous (IV) insulin. Glycemic control during IV insulin therapy was retrospectively assessed comparing periods with and without adjunctive CGM use. Accuracy metrics were computed and Clarke Error Grid analysis performed comparing CGM glucose values with POC measurements. Results: Twenty-four critically ill patients who met criteria for emergency use of CGM resulted in 47 333 CGM and 5677 POC glucose values. During IV insulin therapy, individuals’ glycemic control improved when CGM was used (mean difference –30.7 mg/dL). Among 2194 matched CGM: POC glucose pairs, a high degree of concordance was observed with a mean absolute relative difference of 14.8% and 99.5% of CGM: POC pairs falling in Zones A and B of the Clarke Error Grid. Conclusions: Continuous glucose monitoring use in critically ill COVID-19 patients improved glycemic control during IV insulin therapy. Continuous glucose monitoring glucose data were highly concordant with POC glucose during IV insulin therapy in critically ill patients suggesting that CGM could substitute for POC measurements in inpatients thus reducing patient-provider contact and mitigating infection transmission.