Linh Q. Vu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Linh Q. Vu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Sudhakar L. Rajulu
NASA Johnson Space Center, Houston, TX, USA
5 shared publicationsHan Kim
Leidos Innovations, Houston, Texas, USA
2 shared publicationsK. Han Kim
Senior Human Factors Engineer, Leidos Inc., Houston, TX, USA
2 shared publicationsAndrea Hanson
NASA Johnson Space Center
1 shared publication- Darlene Ruth Nelson
Division of Pulmonary and Critical Care, Mayo Clinic, Rochester, MN
1 shared publication Elizabeth Benson
MEI Technologies Inc
1 shared publication
Latest Publications
- 23 February 2022
- Published by SAGE Publications in Human Factors: The Journal of the Human Factors and Ergonomics Society
- Vol. 65 (6) , 1029-1045
Spacesuit Center of Gravity Assessments for Partial Gravity EVA Simulation in an Underwater Environment
Objective: The objective is to analytically determine the expected CG and build hardware to measure and verify the suited subject’s CG for lunar extravehicular activity (EVA) training in an underwater environment. Background: For lunar EVAs, it is necessary for astronauts to train with a spacesuit in a simulated partial gravity environment. NASA’s Neutral Buoyancy Laboratory (NBL) can provide these conditions by producing negative buoyancy for a submerged suited subject. However, it is critical that the center of gravity (CG) for the human-spacesuit system to be accurate for conditions expected during planetary EVAs. Methods: An underwater force-transducer system and individualized human-spacesuit model was created to provide real-time measurement of CG, including recommendations for weight placement locations and quantity of weight needed on the spacesuit to achieve a realistic lunar spacesuit CG. This method was tested with four suited subjects. Results: Across tested weighout configurations, it was observed that an aft and high CG location will have large postural differences when compared to low and fore CG locations, highlighting the importance of having a proper CG. The system had an accuracy of ±5lbs of the total lunar weight and within ± 15 cm for fore-aft and left-right CG directions of the model predictions. Conclusion: The developed method offers analytical verification of the suited subject’s CG and improves simulation quality of lunar EVAs. Future suit design can also benefit by recommending hardware changes to create ideal CG locations that improve balance and mobility. Application: The developed methodology can be used to verify a proper CG location in future planetary EVA simulations such as different reduced gravity training analogs (e.g. active cable offloading systems).
- 23 February 2022
- Published by SAGE Publications in Human Factors: The Journal of the Human Factors and Ergonomics Society
- Vol. 65 (6) , 1029-1045
Spacesuit Center of Gravity Assessments for Partial Gravity EVA Simulation in an Underwater Environment
Objective: The objective is to analytically determine the expected CG and build hardware to measure and verify the suited subject’s CG for lunar extravehicular activity (EVA) training in an underwater environment. Background: For lunar EVAs, it is necessary for astronauts to train with a spacesuit in a simulated partial gravity environment. NASA’s Neutral Buoyancy Laboratory (NBL) can provide these conditions by producing negative buoyancy for a submerged suited subject. However, it is critical that the center of gravity (CG) for the human-spacesuit system to be accurate for conditions expected during planetary EVAs. Methods: An underwater force-transducer system and individualized human-spacesuit model was created to provide real-time measurement of CG, including recommendations for weight placement locations and quantity of weight needed on the spacesuit to achieve a realistic lunar spacesuit CG. This method was tested with four suited subjects. Results: Across tested weighout configurations, it was observed that an aft and high CG location will have large postural differences when compared to low and fore CG locations, highlighting the importance of having a proper CG. The system had an accuracy of ±5lbs of the total lunar weight and within ± 15 cm for fore-aft and left-right CG directions of the model predictions. Conclusion: The developed method offers analytical verification of the suited subject’s CG and improves simulation quality of lunar EVAs. Future suit design can also benefit by recommending hardware changes to create ideal CG locations that improve balance and mobility. Application: The developed methodology can be used to verify a proper CG location in future planetary EVA simulations such as different reduced gravity training analogs (e.g. active cable offloading systems).
- 2 October 2021
- Published by Taylor & Francis in IISE Transactions on Occupational Ergonomics and Human Factors
- Vol. 9 (3-4) , 134-142
Ergonomic Risk Identification for Spacesuit Movements Using Factorial Analysis
OCCUPATIONAL APPLICATIONS Biomechanical risk factors associated with spacesuit manual material handling tasks were evaluated using the singular value decomposition (SVD) technique. SVD analysis decomposed each lifting tasks into primitive motion patterns called eigenposture progression (EP) that contributed to the overall task. Biomechanical metrics, such as total joint displacement, were calculated for each EP. The first EP (a simultaneous knee, hip, and waist movement) had greater biomechanical demands than other EPs. Thus, tasks such as lifting from the floor were identified as “riskier” by having a greater composition of the first EP. The results of this work can be used to improve a task as well as spacesuit design by minimizing riskier movement patterns as shown in this case study. This methodology can be applied in civilian occupational settings to analyze open-ended tasks (e.g., complex product assembly and construction) for ergonomics assessments. Using this method, worker task strategies can be evaluated quantitatively, compared, and redesigned when necessary.
- 2 October 2021
- Published by Taylor & Francis in IISE Transactions on Occupational Ergonomics and Human Factors
- Vol. 9 (3-4) , 134-142
Ergonomic Risk Identification for Spacesuit Movements Using Factorial Analysis
OCCUPATIONAL APPLICATIONS Biomechanical risk factors associated with spacesuit manual material handling tasks were evaluated using the singular value decomposition (SVD) technique. SVD analysis decomposed each lifting tasks into primitive motion patterns called eigenposture progression (EP) that contributed to the overall task. Biomechanical metrics, such as total joint displacement, were calculated for each EP. The first EP (a simultaneous knee, hip, and waist movement) had greater biomechanical demands than other EPs. Thus, tasks such as lifting from the floor were identified as “riskier” by having a greater composition of the first EP. The results of this work can be used to improve a task as well as spacesuit design by minimizing riskier movement patterns as shown in this case study. This methodology can be applied in civilian occupational settings to analyze open-ended tasks (e.g., complex product assembly and construction) for ergonomics assessments. Using this method, worker task strategies can be evaluated quantitatively, compared, and redesigned when necessary.
- 13 June 2021
- Published by Springer Nature
- p. 429-433
Assessment of Biomechanical Risk Factors During Lifting Tasks in a Spacesuit Using Singular Value Decomposition
- 13 June 2021
- Published by Springer Nature
- p. 429-433
Assessment of Biomechanical Risk Factors During Lifting Tasks in a Spacesuit Using Singular Value Decomposition
- Open Access
- 29 October 2020
- Published by SAGE Publications in Human Factors: The Journal of the Human Factors and Ergonomics Society
- Vol. 64 (4) , 649-661
Evaluating Lumbar Shape Deformation With Fabric Strain Sensors
Objective: To better study human motion inside the space suit and suit-related contact, a multifactor statistical model was developed to predict torso body shape changes and lumbar motion during suited movement by using fabric strain sensors that are placed on the body. Background: Physical interactions within pressurized space suits can pose an injury risk for astronauts during extravehicular activity (EVA). In particular, poor suit fit can result in an injury due to reduced performance capabilities and excessive body contact within the suit during movement. A wearable solution is needed to measure body motion inside the space suit. Methods: An array of flexible strain sensors was attached to the body of 12 male study participants. The participants performed specific static lumbar postures while 3D body scans and sensor measurements were collected. A model was created to predict the body shape as a function of sensor signal and the accuracy was evaluated using holdout cross-validation. Results: Predictions from the torso shape model had an average root mean square error (RMSE) of 2.02 cm. Subtle soft tissue deformations such as skin folding and bulges were accurately replicated in the shape prediction. Differences in posture type did not affect the prediction error. Conclusion: This method provides a useful tool for suited testing and the information gained will drive the development of injury countermeasures and improve suit fit assessments. Application: In addition to space suit design applications, this technique can provide a lightweight and wearable system to perform ergonomic evaluations in field assessments.
- 29 October 2020
- Published by SAGE Publications in Human Factors: The Journal of the Human Factors and Ergonomics Society
- Vol. 64 (4) , 649-661
Open AccessEvaluating Lumbar Shape Deformation With Fabric Strain Sensors
Objective: To better study human motion inside the space suit and suit-related contact, a multifactor statistical model was developed to predict torso body shape changes and lumbar motion during suited movement by using fabric strain sensors that are placed on the body. Background: Physical interactions within pressurized space suits can pose an injury risk for astronauts during extravehicular activity (EVA). In particular, poor suit fit can result in an injury due to reduced performance capabilities and excessive body contact within the suit during movement. A wearable solution is needed to measure body motion inside the space suit. Methods: An array of flexible strain sensors was attached to the body of 12 male study participants. The participants performed specific static lumbar postures while 3D body scans and sensor measurements were collected. A model was created to predict the body shape as a function of sensor signal and the accuracy was evaluated using holdout cross-validation. Results: Predictions from the torso shape model had an average root mean square error (RMSE) of 2.02 cm. Subtle soft tissue deformations such as skin folding and bulges were accurately replicated in the shape prediction. Differences in posture type did not affect the prediction error. Conclusion: This method provides a useful tool for suited testing and the information gained will drive the development of injury countermeasures and improve suit fit assessments. Application: In addition to space suit design applications, this technique can provide a lightweight and wearable system to perform ergonomic evaluations in field assessments.
- 1 March 2020
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 118, 103624
Lumbar posture assessment with fabric strain sensors
- 1 March 2020
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 118, 103624
Lumbar posture assessment with fabric strain sensors
- 15 June 2017
- Published by Springer Nature
- p. 91-99
Development of a Depth Camera-Based Instructional Tool for Resistive Exercise During Spaceflight
- 15 June 2017
- Published by Springer Nature
- p. 91-99
Development of a Depth Camera-Based Instructional Tool for Resistive Exercise During Spaceflight