CCCláudia Constantino

Cláudia Constantino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cláudia Constantino has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    [18F]FDG PET/CT imaging of the metabolic response in advanced breast cancer patients treated with cyclin-dependent kinase 4/6 inhibitors

    by Marcin Kubeczko, Francisco Oliveira, Cláudia Constantino, Joana Castanheira, Helena Gouveia, Leonor Matos, Marcio Debiasi, Michal Jarzab, Durval Costa, Fatima Cardoso, et al.

    Background: Cyclin-dependent kinase 4/6 inhibitors (CDK4/6i) have improved progression-free survival (PFS), overall survival (OS), and quality of life in advanced breast cancer. Although [ 18 F]FDG-PET/CT is an established imaging option in selected patients with metastatic breast cancer, its optimal use for treatment response assessment, particularly during CDK4/6i therapy, remains to be clarified. This study evaluated the prognostic value of metabolic response measured by [ 18 F]FDG-PET/CT in patients treated with CDK4/6i. Methods: The study included ninety-seven patients (median age 61; interquartile range [IQR] 53–72 years) with advanced hormone receptor-positive/human epidermal growth factor receptor 2-negative (HR+/HER2-negative) breast cancer treated with CDK4/6i, who underwent [ 18 F]FDG-PET/CT at baseline and for response assessment. The majority (72%) were treated in the first-line setting. Maximum standardized uptake value (SUV max ) at the first response assessment (SUV as ) and percentage of SUV max change from baseline to first response assessment (ΔSUV max ) were evaluated as prognostic factors for PFS and OS. Results: With a median follow-up of 27.5 months, median PFS was 33.1 months, with a 2-year PFS of 65.6% [95% confidence interval [CI]: 54.8–75.4%]. Eight OS events occurred; the 3-year OS was 91.7% [95% CI 80.6–96.6%], and median OS was not reached. The median ΔSUV max reduction was 57% (IQR 33–73%). A greater ΔSUV max reduction was associated with longer PFS in multivariable analysis ( p = 0.003). Associations with OS were also observed but should be considered exploratory because of the limited number of events. Conclusions: These findings suggest [ 18 F]FDG-PET/CT metabolic response as a potential prognostic tool in advanced HR+/HER2-negative breast cancer treated with CDK4/6i, though larger studies are needed for confirmation.

  • Open Access

    Automatic metabolic breast cancer staging using [¹⁸F]FDG PET/CT: comparison with nuclear medicine physician-based and clinical staging

    by Cláudia Santos Constantino, Carla Oliveira, Francisco P. M. Oliveira, Inês Moreira, Andrea DeCensi, Susana Vinga, Durval C. Costa

    Purpose: This study aimed to evaluate a deep-learning (DL)-based framework to automatically perform breast cancer (BC) metabolic staging on [¹⁸F]FDG PET/CT, and to assess agreement among DL-based, nuclear medicine (NM) physician-based, and clinical staging. Methods: A total of 403 histologically confirmed BC patients who underwent whole-body staging [¹⁸F]FDG PET/CT were retrospectively included. All [ 18 F]FDG avid lesions suspected of malignancy were segmented by an NM physician and classified into four key tumor regions: primary tumor (pT), regional axillary lymph nodes (ALN), extra-axillary locoregional nodes (extra-ALN), and distant metastases (dM). Data were split into training ( n = 303) and testing ( n = 100) sets using a stratified approach. Class-specific DL segmentation networks were developed. A post-processing pipeline was implemented to derive metabolic TNM staging from the DL-based segmentation. Using NM-based and clinical staging segmentation as reference, accuracy, sensitivity, and specificity were computed for T, N, and M. Segmentation performance was evaluated using the Dice coefficient (DC) and lesion detection (LD) metrics. NM-based metabolic staging was also compared with clinical staging. Results: DL-based staging showed concordance with NM-based/clinical staging of 75/62%, 87/74%, and 83/82% for T, N, and M, respectively. For N3 (presence of extra-ALN) and M1 (presence of dM), where [¹⁸F]FDG PET/CT is particularly relevant, sensitivity/specificity of DL-based (NM-based reference) were 0.86/0.96, and 0.97/0.78, respectively. Segmentation performance was good to excellent for pT, ALN, and dM (median DC ≥ 0.83 and LD ≥ 0.78), and moderate for extra-ALN (median DC = 0.63 and LD ≥ 0.71). NM-based metabolic staging agreed with clinical staging in 63%, 80%, and 99% of cases for T, N, and M, respectively. Conclusion: Although expert supervision remains essential, the developed DL-based framework demonstrates potential as a supportive tool for metabolic staging in BC patients, facilitating a workflow-efficient [¹⁸F]FDG PET/CT-based staging assessment.

  • Open Access

    An AI-Based Solution for Denoising Fast-Acquisition [18F]FDG PET: Clinical Feasibility and Quantitative Assessment

    by Luísa C. Silva, Cláudia S. Constantino, Ricardo Teixeira, Joana C. Castanheira, Francisco P. M. Oliveira, Durval C. Costa

    Benefits in patient comfort, efficiency, and sustainability can come from reducing positron emission tomography (PET) scan’s acquisition duration. This study assesses the clinical adequacy of restoring fast-acquisition 18 F-fluorodeoxyglucose ([ 18 F]FDG) PET to its standard-of-care image quality through deep-learning-based (DL) methods. Fast and standard whole-body [ 18 F]FDG PET acquisitions of 117 oncological patients were included in the training and testing of three convolutional neural networks. The best-performing network during training was chosen for clinical evaluation on the test set ( N = 25). Visual assessment and lesion detectability of the fast acquisitions, of 20 and 30 seconds per axial field of view (s/AFOV), with and without DL-based denoising, and of the local standard of care, of 70 s/AFOV, were performed by three experienced nuclear medicine physicians. Quantification was conducted globally (voxel-wise), in healthy organs and the reported lesions. Optimised Gaussian and non-local means filters served as benchmarks. Visual assessment revealed 20 and 30 s/AFOV with DL-based denoising to have similar image quality to the standard of care. Average lesion-based sensitivity and positive predictive value were 74% and 72%, respectively, for 20 s/AFOV + DL and 72% and 80% for 30 s/AFOV + DL. DL-based denoising displayed the highest voxel-wise agreement with the standard-of-care ( p < 0.001). Liver and lungs in the DL-denoised images exhibited a higher signal-to-noise ratio than the standard of care. The median absolute maximum standardised uptake value deviation in the lesions was as low as 0.39 for 20 s/AFOV + DL and 0.30 for 30 s/AFOV + DL. The proposed DL-based method proved to be suitable for the restoration of fast-acquisition whole-body [ 18 F]FDG PET, having resulted in images similar to the standard-of-care acquisitions. DL-based denoising outperformed standard benchmark methods.

  • Open Access

    Baseline [18F]FDG PET/CT and MRI first-order breast tumor features do not improve pathological complete response prediction to neoadjuvant chemotherapy

    by Carla Oliveira, Francisco Oliveira, Cláudia Constantino, Celeste Alves, Maria José Brito, Fátima Cardoso, Durval C. Costa

    Purpose: To verify the ability of pretreatment [18F]FDG PET/CT and T1-weighed dynamic contrast-enhanced MRI to predict pathological complete response (pCR) after neoadjuvant chemotherapy (NAC) in breast cancer (BC) patients. Methods: This retrospective study includes patients with BC of no special type submitted to baseline [18F]FDG PET/CT, NAC and surgery. [18F]FDG PET-based features reflecting intensity and heterogeneity of tracer uptake were extracted from the primary BC and suspicious axillary lymph nodes (ALN), for comparative analysis related to NAC response (pCR vs. non-pCR). Multivariate logistic regression was performed for response prediction combining the breast tumor-extracted PET-based features and clinicopathological features. A subanalysis was performed in a patients’ subsample by adding breast tumor-extracted first-order MRI-based features to the multivariate logistic regression. Results: A total of 170 tumors from 168 patients were included. pCR was observed in 60/170 tumors (20/107 luminal B-like, 25/45 triple-negative and 15/18 HER2-enriched surrogate molecular subtypes). Higher intensity and higher heterogeneity of [18F]FDG uptake in the primary BC were associated with NAC response in HER2-negative tumors (immunohistochemistry score 0, 1 + or 2 + non-amplified by in situ hybridization). Also, higher intensity of tracer uptake was observed in ALN in the pCR group among HER2-negative tumors. No [18F]FDG PET-based features were associated with pCR in the other subgroup analyses. A subsample of 103 tumors was also submitted to extraction of MRI-based features. When combined with clinicopathological features, neither [18F]FDG PET nor MRI-based features had additional value for pCR prediction. The only significant predictors were estrogen receptor status, HER2 expression and grade. Conclusion: Pretreatment [18F]FDG PET-based features from primary BC and ALN are not associated with response to NAC, except in HER2-negative tumors. As compared with pathological features, no breast tumor-extracted PET or MRI-based feature improved response prediction.


  • Open Access

    Evaluation of Semiautomatic and Deep Learning–Based Fully Automatic Segmentation Methods on [18F]FDG PET/CT Images from Patients with Lymphoma: Influence on Tumor Characterization

    by Cláudia S. Constantino, Sónia Leocádio, Francisco P. M. Oliveira, Mariana Silva, Carla Oliveira, Joana C. Castanheira, Ângelo Silva, Sofia Vaz, Ricardo Teixeira, Manuel Neves, et al.

    The objective is to assess the performance of seven semiautomatic and two fully automatic segmentation methods on [18F]FDG PET/CT lymphoma images and evaluate their influence on tumor quantification. All lymphoma lesions identified in 65 whole-body [18F]FDG PET/CT staging images were segmented by two experienced observers using manual and semiautomatic methods. Semiautomatic segmentation using absolute and relative thresholds, k-means and Bayesian clustering, and a self-adaptive configuration (SAC) of k-means and Bayesian was applied. Three state-of-the-art deep learning–based segmentations methods using a 3D U-Net architecture were also applied. One was semiautomatic and two were fully automatic, of which one is publicly available. Dice coefficient (DC) measured segmentation overlap, considering manual segmentation the ground truth. Lymphoma lesions were characterized by 31 features. Intraclass correlation coefficient (ICC) assessed features agreement between different segmentation methods. Nine hundred twenty [18F]FDG-avid lesions were identified. The SAC Bayesian method achieved the highest median intra-observer DC (0.87). Inter-observers’ DC was higher for SAC Bayesian than manual segmentation (0.94 vs 0.84, p < 0.001). Semiautomatic deep learning–based median DC was promising (0.83 (Obs1), 0.79 (Obs2)). Threshold-based methods and publicly available 3D U-Net gave poorer results (0.56 ≤ DC ≤ 0.68). Maximum, mean, and peak standardized uptake values, metabolic tumor volume, and total lesion glycolysis showed excellent agreement (ICC ≥ 0.92) between manual and SAC Bayesian segmentation methods. The SAC Bayesian classifier is more reproducible and produces similar lesion features compared to manual segmentation, giving the best concordant results of all other methods. Deep learning–based segmentation can achieve overall good segmentation results but failed in few patients impacting patients’ clinical evaluation.


  • Are lesion features reproducible between 18F-FDG PET/CT images when acquired on analog or digital PET/CT scanners?

    by Cláudia S. Constantino, Francisco P. M. Oliveira, Mariana Silva, Carla Oliveira, Joana C. Castanheira, Ângelo Silva, Sofia C. Vaz, Pedro Vieira, Durval C. Costa

    Objectives To compare lesion features extracted from 18F-FDG PET/CT images acquired on analog and digital scanners, on consecutive imaging data from the same subjects. Methods Whole-body 18F-FDG PET/CT images from 55 oncological patients were acquired twice after a single 18F-FDG injection, with a digital and an analog PET/CT scanner, alternately. Twenty-nine subjects were examined first on the digital, and 26 first on the analog equipment. Image reconstruction was performed using manufacturer standard clinical protocols and protocols that fulfilled EARL1 specifications. Twenty-five features based on lesion standardized uptake value (SUV) and geometry were assessed. To compare these features, intraclass correlation coefficient (ICC), relative difference (RD), absolute value of RD (|RD|), and repeatability coefficient (RC) were used. Results In total, 323 18F-FDG avid lesions were identified. High agreement (ICC > 0.75) was obtained for most of the lesion features pulled out from both scanners’ imaging data, especially when reconstruction protocols fulfilled EARL1 specifications. For EARL1 reconstruction images, the features frequently used in clinics, SUVmax, SUVpeak, SUVmean, metabolic tumor volume, and total lesion glycolysis, reached an ICC of 0.92, 0.95, 0.87, 0.98, and 0.98, and a median RD (digital-analog) of 3%, 5%, 4%, − 3% and 1%, respectively. Using standard reconstruction protocols, the ICC were 0.84, 0.93, 0.80, 0.98, and 0.98, and the RD were 20%, 11%, 13%, − 7%, and 7%, respectively. Conclusion Under controlled acquisition and reconstruction parameters, most of the features studied can be used for research and clinical work. This is especially important for multicenter studies and patient follow-ups. Key Points • Using manufacturer standard clinical reconstruction protocols, lesions SUV was significantly higher when using the digital scanner, especially the SUVmax that was approximately 20% higher. • High agreement was obtained for the majority of the lesion features when using reconstruction protocols that fulfilled EARL1 specifications. • Longitudinal patient studies can be performed interchangeably between digital and analog scanners when both fulfill EARL1 specifications.