Xue Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xue Jiang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Peter B. Lillehoj
Department of Mechanical Engineering, Rice University, Houston, USA
3 shared publications Bi Lin
Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University, Xi’an, Shaanxi 710071, China
1 shared publication- Guangjian Zhang
Department of Thoracic Surgery The First Affiliated Hospital of Xi'an Jiaotong University Xi'an China
1 shared publication - Jinhai Fan
Department of Urology, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, PR China
1 shared publication - Liang Kong
State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Oral Diseases, Department of Oral and Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, China
1 shared publication - Ruichan Lv
Xidian University
1 shared publication
Latest Publications
- 1 May 2022
- Published by Elsevier in Chinese Chemical Letters
- Vol. 33 (5) , 2243-2252
Recent developments of droplets-based microfluidics for bacterial analysis
- 1 May 2022
- Published by Elsevier in Chinese Chemical Letters
- Vol. 33 (5) , 2243-2252
Recent developments of droplets-based microfluidics for bacterial analysis
- Open Access
- 21 December 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 1084-1090
Lateral flow immunochromatographic assay on a single piece of paper
Lateral flow immunochromatographic assays (LFIAs) are analytical devices used to detect the presence of one or more target analytes in a liquid sample. While LFIAs are one of the simplest and inexpensive types of immunoassays, they consist of multiple components (sample pad, conjugate pad, membrane, absorbent pad, backing card) and materials, requiring time-consuming device assembly. Here, we report a unique lateral flow immunochromatographic assay constructed from a single piece of cellulose paper, which is fabricated via laser cutting. Compared with conventional lateral flow immunochromatographic devices, this single-layer immunoassay enables simpler and faster fabrication, while minimizing material consumption and overall device costs. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2 (PfHRP2), a biomarker for malaria infection, which could be detected at concentrations as low as 4 ng mL−1 by the naked eye with no cross reactivity with other common Plasmodium protein biomarkers. While offering similar speed and ease-of-use as conventional LFIAs with a higher detection sensitivity than existing LFIAs for PfHRP2 detection, this single-layer lateral flow immunoassay has the potential to improve malaria testing, as well as the detection of other important protein biomarkers for point-of-care testing.
- 21 December 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 1084-1090
Open AccessLateral flow immunochromatographic assay on a single piece of paper
Lateral flow immunochromatographic assays (LFIAs) are analytical devices used to detect the presence of one or more target analytes in a liquid sample. While LFIAs are one of the simplest and inexpensive types of immunoassays, they consist of multiple components (sample pad, conjugate pad, membrane, absorbent pad, backing card) and materials, requiring time-consuming device assembly. Here, we report a unique lateral flow immunochromatographic assay constructed from a single piece of cellulose paper, which is fabricated via laser cutting. Compared with conventional lateral flow immunochromatographic devices, this single-layer immunoassay enables simpler and faster fabrication, while minimizing material consumption and overall device costs. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2 (PfHRP2), a biomarker for malaria infection, which could be detected at concentrations as low as 4 ng mL−1 by the naked eye with no cross reactivity with other common Plasmodium protein biomarkers. While offering similar speed and ease-of-use as conventional LFIAs with a higher detection sensitivity than existing LFIAs for PfHRP2 detection, this single-layer lateral flow immunoassay has the potential to improve malaria testing, as well as the detection of other important protein biomarkers for point-of-care testing.
- Open Access
- 2 November 2020
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 6 (1) , 1-11
Microneedle-based skin patch for blood-free rapid diagnostic testing
Rapid diagnostic tests are one of the most commonly used tests to detect and screen for infectious diseases in the developing world. While these tests are simple, inexpensive, and readily available, they rely on finger-prick blood sampling, which requires trained medical personnel, poses risks of infection, and can complicate cooperation in young children, asymptomatic individuals, and communities with blood taboos. Here, we report a novel microneedle-based skin patch for the rapid detection of protein biomarkers in dermal interstitial fluid. Sample collection is facilitated by a hydrophilic hollow microneedle array that autonomously extracts and transports interstitial fluid to an antibody-based lateral flow test strip via surface tension for colorimetric antigen detection. We employ a simple gold enhancement treatment to enhance the detection sensitivity of this colloidal gold-based lateral flow assay and elucidate the underlying mechanism of this enhancement mechanism through experimental investigation. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2, a biomarker for malaria infection, which could be detected at concentrations as low as 8 ng/mL. Each test can be completed in <20 min and requires no equipment. To the best of our knowledge, this work is the first demonstration of a microneedle-based lateral flow assay for rapid protein detection in dermal interstitial fluid. In addition to its simplicity, minimally invasive nature, and low cost, this diagnostic device can be readily adapted to detect other protein biomarkers in interstitial fluid, making it a promising tool for point-of-care testing.
- 2 November 2020
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 6 (1) , 1-11
Open AccessMicroneedle-based skin patch for blood-free rapid diagnostic testing
Rapid diagnostic tests are one of the most commonly used tests to detect and screen for infectious diseases in the developing world. While these tests are simple, inexpensive, and readily available, they rely on finger-prick blood sampling, which requires trained medical personnel, poses risks of infection, and can complicate cooperation in young children, asymptomatic individuals, and communities with blood taboos. Here, we report a novel microneedle-based skin patch for the rapid detection of protein biomarkers in dermal interstitial fluid. Sample collection is facilitated by a hydrophilic hollow microneedle array that autonomously extracts and transports interstitial fluid to an antibody-based lateral flow test strip via surface tension for colorimetric antigen detection. We employ a simple gold enhancement treatment to enhance the detection sensitivity of this colloidal gold-based lateral flow assay and elucidate the underlying mechanism of this enhancement mechanism through experimental investigation. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2, a biomarker for malaria infection, which could be detected at concentrations as low as 8 ng/mL. Each test can be completed in <20 min and requires no equipment. To the best of our knowledge, this work is the first demonstration of a microneedle-based lateral flow assay for rapid protein detection in dermal interstitial fluid. In addition to its simplicity, minimally invasive nature, and low cost, this diagnostic device can be readily adapted to detect other protein biomarkers in interstitial fluid, making it a promising tool for point-of-care testing.
- 14 April 2020
- Published by American Chemical Society (ACS) in ACS Combinatorial Science
- Vol. 22 (5) , 285-296
Optimized Multimetal Sensitized Phosphor for Enhanced Red Up-Conversion Luminescence by Machine Learning
In this research, machine learning including genetic algorithm (GA) and support vector machine (SVM) algorithm is used to solve the “low up-conversion luminescence (UCL) intensity” problem in order to find the optimal phosphor with enhanced red UCL emis-sion using of multi-element K/Li/Mn metal modulation. Compared with the first genera-tion of phosphors, the best phosphors’ fluorescence intensity occurs in the third genera-tion optimized by GA, with a stronger brightness (4.91-fold), a higher relative quantum yield (6.40-fold), and an enhanced tissue penetration depth (by 5 mm). The single and multiple dopants effect on the upconversion intensity of K+Li+Mn sensitizers are also studied: the intensity increases first and then decreases with the increase of Yb/Er/K+Li+Mn content, and the optimized K+Li+Mn concentration is 6.03%. In order to confirm the stability of the brightness optimization by GA, a batch of phosphors were synthesized with the same element proportion, and the similarity of fluorescence intensity of two batches of phosphors was evaluated by SVM algorithm with classification accura-cy index. Finally, the optimized phosphor was used for bio-imaging and phosphor-LED.
- 14 April 2020
- Published by American Chemical Society (ACS) in ACS Combinatorial Science
- Vol. 22 (5) , 285-296
Optimized Multimetal Sensitized Phosphor for Enhanced Red Up-Conversion Luminescence by Machine Learning
In this research, machine learning including genetic algorithm (GA) and support vector machine (SVM) algorithm is used to solve the “low up-conversion luminescence (UCL) intensity” problem in order to find the optimal phosphor with enhanced red UCL emis-sion using of multi-element K/Li/Mn metal modulation. Compared with the first genera-tion of phosphors, the best phosphors’ fluorescence intensity occurs in the third genera-tion optimized by GA, with a stronger brightness (4.91-fold), a higher relative quantum yield (6.40-fold), and an enhanced tissue penetration depth (by 5 mm). The single and multiple dopants effect on the upconversion intensity of K+Li+Mn sensitizers are also studied: the intensity increases first and then decreases with the increase of Yb/Er/K+Li+Mn content, and the optimized K+Li+Mn concentration is 6.03%. In order to confirm the stability of the brightness optimization by GA, a batch of phosphors were synthesized with the same element proportion, and the similarity of fluorescence intensity of two batches of phosphors was evaluated by SVM algorithm with classification accura-cy index. Finally, the optimized phosphor was used for bio-imaging and phosphor-LED.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 38-41
Pneumatic microvalves fabricated by multi-material 3D printing
We report an innovative and simple approach for fabricating pneumatic microvalves via an assembly-free 3D printing technique. These valves are based on monolithic elastomeric valves fabricated by multilayer soft lithography but this method circumvents the need for specialized layering, alignment and bonding. 3D printed microfluidic devices containing flow channels and pneumatic valves were fabricated and tested for functionality. Using these devices, we successfully demonstrate valve actuation for precise liquid flow control and on/off operation. The speed and simplicity of this approach make it a promising technique for rapid prototyping and manufacturing of 3D printed microfluidic devices with fully integrated components.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 38-41
Pneumatic microvalves fabricated by multi-material 3D printing
We report an innovative and simple approach for fabricating pneumatic microvalves via an assembly-free 3D printing technique. These valves are based on monolithic elastomeric valves fabricated by multilayer soft lithography but this method circumvents the need for specialized layering, alignment and bonding. 3D printed microfluidic devices containing flow channels and pneumatic valves were fabricated and tested for functionality. Using these devices, we successfully demonstrate valve actuation for precise liquid flow control and on/off operation. The speed and simplicity of this approach make it a promising technique for rapid prototyping and manufacturing of 3D printed microfluidic devices with fully integrated components.