Ayda Montaser Koohsari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ayda Montaser Koohsari has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Elmira Anzaniyan
Department of Architecture and Technology, Pars University, Tehran, Iran
1 shared publication - Matin Alaghmandan
School of Architecture and Urbanism, Shahid Beheshti University, Tehran, Iran
1 shared publication Shahin Heidari
Department of Architecture and Energy, Faculty of Architecture and Urbanism, University of Tehran, Tehran, Iran
1 shared publication
Latest Publications
- 21 October 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (10) , 1456-1471
Design, fabrication and computational simulation of a bio-kinetic façade inspired by the mechanism of the Lupinus Succulentus plant for daylight and energy efficiency
Designing a facade that is able to keep the balance between the daylight, view out and energy load is a challenge. The present paper aims to use the sun’s radiant energy utilizing the facade as the outer skin, which is in contact with the surroundings to reduce nonrenewable energy consumption and provide comfort to occupants. Using bionic science, a kinetic facade prototype was designed and fabricated with Lupinus Succulentus plants’ movement mechanism, a type of sun-tracking plant. This kinetic façade has been simulated by Grasshopper on the facade of the Southern side of an open office in Tehran. Accordingly, this study is to investigate a bio-kinetic facade, using the integration among kinetic architecture, biomimicry and occupants’ visual and thermal comfort. Bio-kinetic façade not only causes cooling load reduction by approximately 7% but also prevents the direct light entry, resulting in electric lighting load’s reduction by about 48%, which was calculated by Honey bee and Ladybug plugins.
- 21 October 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (10) , 1456-1471
Design, fabrication and computational simulation of a bio-kinetic façade inspired by the mechanism of the Lupinus Succulentus plant for daylight and energy efficiency
Designing a facade that is able to keep the balance between the daylight, view out and energy load is a challenge. The present paper aims to use the sun’s radiant energy utilizing the facade as the outer skin, which is in contact with the surroundings to reduce nonrenewable energy consumption and provide comfort to occupants. Using bionic science, a kinetic facade prototype was designed and fabricated with Lupinus Succulentus plants’ movement mechanism, a type of sun-tracking plant. This kinetic façade has been simulated by Grasshopper on the facade of the Southern side of an open office in Tehran. Accordingly, this study is to investigate a bio-kinetic facade, using the integration among kinetic architecture, biomimicry and occupants’ visual and thermal comfort. Bio-kinetic façade not only causes cooling load reduction by approximately 7% but also prevents the direct light entry, resulting in electric lighting load’s reduction by about 48%, which was calculated by Honey bee and Ladybug plugins.
- 4 November 2020
- Published by Emerald Publishing in Built Environment Project and Asset Management
- Vol. 11 (4) , 673-686
Optimizing window size by integrating energy and lighting analyses considering occupants’ visual satisfaction
Purpose: The purpose of this paper is to determine the approximate window-to-wall ratio (WWR), window width-to-height ratio (WHR) and sill level for a room in Rasht–Gilan province and to present an optimal window in each of the WWR ranges providing the minimum energy consumption by integrating artificial lighting and thermal analyses, whilst maintaining internal comfort conditions using dynamic evaluation.Design/methodology/approach: The process of modelling has four main steps: 1 – defining the building's features and requirements, 2 – validating input weather file data by on-site measurement, 3 – determining input parameters for the lighting and thermal analysis and 4 – clarifying variable parameters and fitness function for the optimization algorithm. Also, the survey study is performed in a daylit office room, in which 30 employees are employed to answer the questions in three different times of a day. In this process, the impact of daylight on their visual comfort is surveyed in 1,350 different illuminance levels which are manually recorded.Findings: The range of useful daylight illuminance (UDI) values is determined as 200–1,000 lux. The optimum range of WWRs in the case study is 15%–25%. Also, due to the appropriate window height, electric lighting could be decreased by 40%.Originality/value: Thermal and lighting performance in buildings is the relation of facade characteristics to environmental sustainability. Recent studies focussed on optimizing WWR and window characteristics considering thermal comfort and energy analyses. However, architects need freedom for designing façade and making decisions in their first sketches. Thus a guideline for optimum window conditions in each WWR is required. Also, considering occupants' behaviour in practical buildings, the visual comfort investigation is a gap in WWR optimization.
- 4 November 2020
- Published by Emerald Publishing in Built Environment Project and Asset Management
- Vol. 11 (4) , 673-686
Optimizing window size by integrating energy and lighting analyses considering occupants’ visual satisfaction
Purpose: The purpose of this paper is to determine the approximate window-to-wall ratio (WWR), window width-to-height ratio (WHR) and sill level for a room in Rasht–Gilan province and to present an optimal window in each of the WWR ranges providing the minimum energy consumption by integrating artificial lighting and thermal analyses, whilst maintaining internal comfort conditions using dynamic evaluation.Design/methodology/approach: The process of modelling has four main steps: 1 – defining the building's features and requirements, 2 – validating input weather file data by on-site measurement, 3 – determining input parameters for the lighting and thermal analysis and 4 – clarifying variable parameters and fitness function for the optimization algorithm. Also, the survey study is performed in a daylit office room, in which 30 employees are employed to answer the questions in three different times of a day. In this process, the impact of daylight on their visual comfort is surveyed in 1,350 different illuminance levels which are manually recorded.Findings: The range of useful daylight illuminance (UDI) values is determined as 200–1,000 lux. The optimum range of WWRs in the case study is 15%–25%. Also, due to the appropriate window height, electric lighting could be decreased by 40%.Originality/value: Thermal and lighting performance in buildings is the relation of facade characteristics to environmental sustainability. Recent studies focussed on optimizing WWR and window characteristics considering thermal comfort and energy analyses. However, architects need freedom for designing façade and making decisions in their first sketches. Thus a guideline for optimum window conditions in each WWR is required. Also, considering occupants' behaviour in practical buildings, the visual comfort investigation is a gap in WWR optimization.