Dingyi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dingyi Wang has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Guibin Jiang
State Key Laboratory of Environmental Chemistry and Toxicology, Research Center for Eco-environmental Sciences, Chinese Academy of Sciences
10 shared publications - Ligang Hu
Chinese Academy of Sciences
10 shared publications - Yongguang Yin
University of Chinese Academy of Sciences
5 shared publications - Lihong Liu
State Key Laboratory of Environmental Chemistry and Ecotoxicology
4 shared publications - Bin He
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
3 shared publications Dayi Ling
State Key Laboratory of Environmental Chemistry and Ecotoxicology
3 shared publications
Latest Publications
- 24 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (35) , 25870-25879
Novel Impingement-Plate Mouthpieces: Enhancing Data Quality in Breathomics Analysis via Direct High-Resolution Mass Spectrometry
Breath sampling mouthpieces are essential for breathomics research, as they effectively remove saliva contamination during sampling. However, for real-time online mass spectrometric breath analysis, the widely adopted filter-based mouthpieces substantially compromise data quality due to analyte adsorption and background interference. In this study, guided by the inertial impaction principle, we designed and fabricated three impingement-plate mouthpiece types via 3D printing using biocompatible, low-porosity poly(lactic-co-glycolic acid). Computational fluid dynamics simulations and salivary amylase validation experiments confirmed efficient saliva droplet interception by the proposed configurations. Targeted detection of a ten-component gas standard mixture by secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS) demonstrated that impingement-plate types exhibited far fewer statistically significant deviations from the control group compared with the filter-based mouthpiece. Among the three designs, the reverse-raked configuration yielded responses closest to the control for most analytes. The types also provided improved signal stability and reproducibility, with interunit coefficients of variation (CVs, n = 10) of 6.43–29.84%, compared with 28.91–66.36% for the filter-based mouthpiece. Principal component analysis based on high-purity nitrogen purging tests showed that the impingement-plate mouthpiece groups clustered closer to the control group than the filter group, suggesting minimal background interference. Untargeted breath profiling confirmed that mass spectral features acquired with impingement-plate mouthpieces were highly consistent with those obtained from filter-free sampling, while the filter-based mouthpiece induced deviations in breath metabolic signatures. Overall, inertial impaction-based designs mitigate the trade-off between saliva droplet removal and analyte transmission, reducing mouthpiece-derived bias and improving data fidelity and analytical robustness in real-time breathomics.
- 24 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (35) , 25870-25879
Novel Impingement-Plate Mouthpieces: Enhancing Data Quality in Breathomics Analysis via Direct High-Resolution Mass Spectrometry
Breath sampling mouthpieces are essential for breathomics research, as they effectively remove saliva contamination during sampling. However, for real-time online mass spectrometric breath analysis, the widely adopted filter-based mouthpieces substantially compromise data quality due to analyte adsorption and background interference. In this study, guided by the inertial impaction principle, we designed and fabricated three impingement-plate mouthpiece types via 3D printing using biocompatible, low-porosity poly(lactic-co-glycolic acid). Computational fluid dynamics simulations and salivary amylase validation experiments confirmed efficient saliva droplet interception by the proposed configurations. Targeted detection of a ten-component gas standard mixture by secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS) demonstrated that impingement-plate types exhibited far fewer statistically significant deviations from the control group compared with the filter-based mouthpiece. Among the three designs, the reverse-raked configuration yielded responses closest to the control for most analytes. The types also provided improved signal stability and reproducibility, with interunit coefficients of variation (CVs, n = 10) of 6.43–29.84%, compared with 28.91–66.36% for the filter-based mouthpiece. Principal component analysis based on high-purity nitrogen purging tests showed that the impingement-plate mouthpiece groups clustered closer to the control group than the filter group, suggesting minimal background interference. Untargeted breath profiling confirmed that mass spectral features acquired with impingement-plate mouthpieces were highly consistent with those obtained from filter-free sampling, while the filter-based mouthpiece induced deviations in breath metabolic signatures. Overall, inertial impaction-based designs mitigate the trade-off between saliva droplet removal and analyte transmission, reducing mouthpiece-derived bias and improving data fidelity and analytical robustness in real-time breathomics.
- Open Access
- 17 July 2026
- Published by American Chemical Society (ACS) in Environment & Health
- Vol. 4  (11) , 2517-2529
Spatiotemporal Profiling and Phase Partitioning of Emerging Pollutants in the Southern Bohai Sea: Insights from High-Resolution Screening and Risk Assessment
Emerging pollutants (EPs) in the marine environment pose growing ecological concerns due to their persistence, bioactivity, and limited regulatory oversight. As a critical interface between land and sea, coastal environments are highly vulnerable to anthropogenic contamination. In this study, 403 compounds spanning 14 chemical categories were identified in seawater, suspended particulate matter, and sediments using high-resolution mass spectrometry (HRMS) combined with suspect screening. By integrating multimatrix occurrence data with physicochemical descriptor analysis, this work provides a broader perspective on pollutant occurrence and environmental behavior in a semienclosed coastal system. Concentrations in seawater ranged from below detection limits to 8.6 × 103 ng L–1, while suspended particulate matter and sediment concentrations reached up to 5.9 × 103 ng L–1 and 7.6 × 102 ng g–1, respectively. Active pharmaceutical ingredients, pesticides, and intermediates were the dominant contaminant categories. Notably, 78 compounds appear to be newly reported in this region based on available literature. Partitioning analysis indicates that dissolved-particulate distribution patterns were associated with multiple physicochemical descriptors, including log KOW, molar refractivity, polarizability, and aqueous solubility, indicating that hydrophobicity alone may not fully capture the phase behavior of polar or multifunctional compounds. Differences between spring and summer sampling campaigns indicated potential seasonal variability, with generally higher detection frequencies and concentrations during summer. Spatial hotspots were mainly associated with land-based inputs and hydrodynamic transport. Ecological risk assessment identified 17 prioritized compounds, with pesticide-related compounds and certain personal care product ingredients exhibiting elevated ecological risks, underscoring the importance of considering co-occurring contaminants in future ecological risk assessments. Collectively, this study provides insight into the occurrence and distribution characteristics of EPs in coastal environments and provides a transferable framework for risk-based management in marginal seas.
- 17 July 2026
- Published by American Chemical Society (ACS) in Environment & Health
- Vol. 4  (11) , 2517-2529
Open AccessSpatiotemporal Profiling and Phase Partitioning of Emerging Pollutants in the Southern Bohai Sea: Insights from High-Resolution Screening and Risk Assessment
Emerging pollutants (EPs) in the marine environment pose growing ecological concerns due to their persistence, bioactivity, and limited regulatory oversight. As a critical interface between land and sea, coastal environments are highly vulnerable to anthropogenic contamination. In this study, 403 compounds spanning 14 chemical categories were identified in seawater, suspended particulate matter, and sediments using high-resolution mass spectrometry (HRMS) combined with suspect screening. By integrating multimatrix occurrence data with physicochemical descriptor analysis, this work provides a broader perspective on pollutant occurrence and environmental behavior in a semienclosed coastal system. Concentrations in seawater ranged from below detection limits to 8.6 × 103 ng L–1, while suspended particulate matter and sediment concentrations reached up to 5.9 × 103 ng L–1 and 7.6 × 102 ng g–1, respectively. Active pharmaceutical ingredients, pesticides, and intermediates were the dominant contaminant categories. Notably, 78 compounds appear to be newly reported in this region based on available literature. Partitioning analysis indicates that dissolved-particulate distribution patterns were associated with multiple physicochemical descriptors, including log KOW, molar refractivity, polarizability, and aqueous solubility, indicating that hydrophobicity alone may not fully capture the phase behavior of polar or multifunctional compounds. Differences between spring and summer sampling campaigns indicated potential seasonal variability, with generally higher detection frequencies and concentrations during summer. Spatial hotspots were mainly associated with land-based inputs and hydrodynamic transport. Ecological risk assessment identified 17 prioritized compounds, with pesticide-related compounds and certain personal care product ingredients exhibiting elevated ecological risks, underscoring the importance of considering co-occurring contaminants in future ecological risk assessments. Collectively, this study provides insight into the occurrence and distribution characteristics of EPs in coastal environments and provides a transferable framework for risk-based management in marginal seas.
- 30 May 2026
- Published by Elsevier in Journal of Food Engineering
- Vol. 420
Starch gel rheology vs 3D printing: Multi-factor orthogonal study
- 30 May 2026
- Published by Elsevier in Journal of Food Engineering
- Vol. 420
Starch gel rheology vs 3D printing: Multi-factor orthogonal study
- 27 March 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (13) , 9812-9820
3D-Printed Droplet Microfluidic TRA-ICP-MS Platform: Single-Cell Analysis of Cadmium and Nanoplastics Coexposure in Synechocystis
Nanoplastics (NPs) in aquatic environments raise concerns as carriers that alter the bioavailability of co-occurring pollutants, such as cadmium (Cd), affecting combined toxicity. Precision toxicology now demands single-cell assessments to provide novel insights into pollutant interactions. In this study, we utilized a 3D-printed droplet microfluidic platform integrated with time-resolved analysis (TRA)─inductively coupled plasma mass spectrometry (ICP-MS)─to investigate the uptake behavior of single algal cells exposed to Cd and Eu-containing polystyrene (PS) NPs. 3D printing enables rapid prototyping and design flexibility for optimized microfluidic chips, while the monolithic structure eliminates assembly errors, reduces dead volume, and supports large-scale production. The droplet platform offers high-throughput single-cell encapsulation; coupled with TRA-ICP-MS, it minimizes cross-contamination and enhances sensitivity for multielement single-cell analysis. Single-cell analysis revealed that coexposure increased both the proportion of Eu/Cd-containing cells and the uptaken Eu/Cd content. The adsorption of Cd2+ imparted a more positive surface charge to PS NPs. This promoted heterogeneous aggregation between algal cells and PS NPs, thereby enhancing the bioavailability of PS/Cd2+ to the algae. Complementing these single-cell measurements, bulk-cell assays were conducted to evaluate the toxicological impacts of coexposure to Cd and PS NPs on microalgae. The results demonstrate that coexposure to PS NPs and Cd2+ resulted in synergistic effects, including enhanced growth inhibition, photosynthetic impairment, membrane damage, and increased secretion of extracellular polymers. These findings highlight the increased ecological risks posed to aquatic organisms by the coexposure to PS NPs and Cd2+, emphasizing the need for comprehensive assessments of nanoplastic-pollutant interactions in aquatic ecosystems.
- 27 March 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98  (13) , 9812-9820
3D-Printed Droplet Microfluidic TRA-ICP-MS Platform: Single-Cell Analysis of Cadmium and Nanoplastics Coexposure in Synechocystis
Nanoplastics (NPs) in aquatic environments raise concerns as carriers that alter the bioavailability of co-occurring pollutants, such as cadmium (Cd), affecting combined toxicity. Precision toxicology now demands single-cell assessments to provide novel insights into pollutant interactions. In this study, we utilized a 3D-printed droplet microfluidic platform integrated with time-resolved analysis (TRA)─inductively coupled plasma mass spectrometry (ICP-MS)─to investigate the uptake behavior of single algal cells exposed to Cd and Eu-containing polystyrene (PS) NPs. 3D printing enables rapid prototyping and design flexibility for optimized microfluidic chips, while the monolithic structure eliminates assembly errors, reduces dead volume, and supports large-scale production. The droplet platform offers high-throughput single-cell encapsulation; coupled with TRA-ICP-MS, it minimizes cross-contamination and enhances sensitivity for multielement single-cell analysis. Single-cell analysis revealed that coexposure increased both the proportion of Eu/Cd-containing cells and the uptaken Eu/Cd content. The adsorption of Cd2+ imparted a more positive surface charge to PS NPs. This promoted heterogeneous aggregation between algal cells and PS NPs, thereby enhancing the bioavailability of PS/Cd2+ to the algae. Complementing these single-cell measurements, bulk-cell assays were conducted to evaluate the toxicological impacts of coexposure to Cd and PS NPs on microalgae. The results demonstrate that coexposure to PS NPs and Cd2+ resulted in synergistic effects, including enhanced growth inhibition, photosynthetic impairment, membrane damage, and increased secretion of extracellular polymers. These findings highlight the increased ecological risks posed to aquatic organisms by the coexposure to PS NPs and Cd2+, emphasizing the need for comprehensive assessments of nanoplastic-pollutant interactions in aquatic ecosystems.
- 19 March 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60  (12) , 9704-9712
Divergent Hydrodynamic Impacts of Feed Spacer Designs on Scaling and Biofouling in Spiral Wound Membrane Modules
Spiral wound membrane (SWM) modules are vital for water purification technologies but suffer from performance degradation caused by membrane fouling. Existing studies on SWM feed spacer designs predominantly target single-type fouling mitigation (e.g., biofouling), lacking cross-comparative assessment of different fouling challenges. This study investigates how geometric modifications of columnar-node feed spacers regulate hydrodynamic conditions to combat inorganic scaling and biofouling differentially via combined numerical and experimental approaches. Our results reveal that spacer architectures dictate resistance to fouling through divergent hydrodynamic mediation pathways. The triangular mesh configurations demonstrated superior scaling mitigation performance by enhancing shear stress and solute mass transfer efficiency to suppress concentration polarization, while the diamond-shaped columnar-node design effectively minimized biofouling through reduced hydraulic stagnant zones that typically facilitate microbial adhesion. The hexagonal architectures exacerbated both fouling types due to inadequate fluid mixing, highlighting critical trade-offs between turbulence generation and hydraulic resistance. Overall, the spacer design for scaling control should enhance mass transfer efficiency, while that for biofouling inhibition is suggested to diminish the proportion of low-velocity regions in the feed channel. These insights establish a mechanistic foundation for developing specialized feed spacers that target dominant fouling challenges, advancing the rational design of SWM modules across diverse water treatment applications.
- 19 March 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60  (12) , 9704-9712
Divergent Hydrodynamic Impacts of Feed Spacer Designs on Scaling and Biofouling in Spiral Wound Membrane Modules
Spiral wound membrane (SWM) modules are vital for water purification technologies but suffer from performance degradation caused by membrane fouling. Existing studies on SWM feed spacer designs predominantly target single-type fouling mitigation (e.g., biofouling), lacking cross-comparative assessment of different fouling challenges. This study investigates how geometric modifications of columnar-node feed spacers regulate hydrodynamic conditions to combat inorganic scaling and biofouling differentially via combined numerical and experimental approaches. Our results reveal that spacer architectures dictate resistance to fouling through divergent hydrodynamic mediation pathways. The triangular mesh configurations demonstrated superior scaling mitigation performance by enhancing shear stress and solute mass transfer efficiency to suppress concentration polarization, while the diamond-shaped columnar-node design effectively minimized biofouling through reduced hydraulic stagnant zones that typically facilitate microbial adhesion. The hexagonal architectures exacerbated both fouling types due to inadequate fluid mixing, highlighting critical trade-offs between turbulence generation and hydraulic resistance. Overall, the spacer design for scaling control should enhance mass transfer efficiency, while that for biofouling inhibition is suggested to diminish the proportion of low-velocity regions in the feed channel. These insights establish a mechanistic foundation for developing specialized feed spacers that target dominant fouling challenges, advancing the rational design of SWM modules across diverse water treatment applications.
- Open Access
- 17 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97  (51) , 28139-28147
A Simple Online Internal Standard Calibration Strategy for Single-Particle Inductively Coupled Plasma Mass Spectrometry Based on Multielement Analysis
Single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) is a powerful tool for resolving particle heterogeneity. However, in real environmental and biological samples, matrix effects pose significant challenges to accurate mass/size determination. Herein, we first systematically investigated the specific matrix effects on each stage of SP-ICP-MS analysis. Results showed that the sizes of Ag nanoparticles in the typical matrices were underestimated by nearly 10 nm due to 30-50% signal attenuation. To address this issue, we developed an online internal standard calibration strategy based on multielement detection and nonanalyte elements as internal standards. The theory of a novel calibration approach involving the use of nonanalyte elements as internal standards for signal response calibration was proposed and experimentally validated. The multielement detection mode was employed to measure the analyte (Ag) and internal standard elements (Pd and Au) within a single analytical run, enabling simultaneous correction of matrix-induced variations in signal response and nebulization efficiency. Under optimized time-resolution conditions (dwell time of 5 ms), the measured sizes of the particles in both simulated and real matrices showed good agreement with the true values. Overall, the proposed method provides a simple, reliable, and flexible solution for extending the applicability of SP-ICP-MS to the analysis of complex environmental and biological samples.
- 17 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97  (51) , 28139-28147
Open AccessA Simple Online Internal Standard Calibration Strategy for Single-Particle Inductively Coupled Plasma Mass Spectrometry Based on Multielement Analysis
Single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) is a powerful tool for resolving particle heterogeneity. However, in real environmental and biological samples, matrix effects pose significant challenges to accurate mass/size determination. Herein, we first systematically investigated the specific matrix effects on each stage of SP-ICP-MS analysis. Results showed that the sizes of Ag nanoparticles in the typical matrices were underestimated by nearly 10 nm due to 30-50% signal attenuation. To address this issue, we developed an online internal standard calibration strategy based on multielement detection and nonanalyte elements as internal standards. The theory of a novel calibration approach involving the use of nonanalyte elements as internal standards for signal response calibration was proposed and experimentally validated. The multielement detection mode was employed to measure the analyte (Ag) and internal standard elements (Pd and Au) within a single analytical run, enabling simultaneous correction of matrix-induced variations in signal response and nebulization efficiency. Under optimized time-resolution conditions (dwell time of 5 ms), the measured sizes of the particles in both simulated and real matrices showed good agreement with the true values. Overall, the proposed method provides a simple, reliable, and flexible solution for extending the applicability of SP-ICP-MS to the analysis of complex environmental and biological samples.
- 8 September 2025
- Published by American Chemical Society (ACS) in ACS Sustainable Resource Management
- Vol. 2  (9) , 1731-1741
Life Cycle Assessment of 3D Printing for Precision Analytical Instrument Components: Carbon Emission Reduction Potential in ICP-MS Spray Chamber Manufacturing
- 8 September 2025
- Published by American Chemical Society (ACS) in ACS Sustainable Resource Management
- Vol. 2  (9) , 1731-1741
Life Cycle Assessment of 3D Printing for Precision Analytical Instrument Components: Carbon Emission Reduction Potential in ICP-MS Spray Chamber Manufacturing
- Open Access
- 1 August 2025
- Published by American Chemical Society (ACS) in Environment & Health
- Vol. 3  (12) , 1510-1520
Exploring the Antagonistic Effects of Bisphenols with Nonmonotonic Dose–Response Curves on the Estrogen Receptor
The nonmonotonic dose–response curve (NMDRC) is a prevalent characteristic of endocrine-disrupting chemicals (EDCs) in activating nuclear receptors (NRs), implicating intricate regulatory mechanisms. In this study, the agonistic and antagonistic activities of 11 bisphenols on the estrogen receptor (ER) were screened using MVLN cells. Three distinct dose–response patterns were observed, namely, S-shaped, inverted S-shaped, and bell-shaped profiles, corresponding to the agonistic, antagonistic, and nonmonotonic effects on ERs, respectively. To further explore NMDRC, bisphenol B (BPB) and bisphenol AF (BPAF), as representative compounds, were specifically investigated for their antagonistic effects on ER under high exposure concentrations (10–50 μmol/L). Notably, the successive decline in cell viability suggested a subhealthy cell state upon high-dose chemical treatments, compromising cell response in ER transactivation. Unlike the specific effect induced by an ERα antagonist (4-hydroxytamoxifen, 4OHT), the nonspecific inhibitory effects of BPB and BPAF on ER transactivation were further confirmed with their identical antagonistic curves, with or without E2 cotreatment, due to hydrophobicity-related cellular baseline toxicity. Accordingly, the inhibitory effects on NR transactivation might not necessarily be considered as a specific antagonistic activity. Thus, a more cautious inspection is highly encouraged in screening NR antagonism-centered endocrine-disrupting effects of emerging chemicals by carefully reviewing the specificity of signal reduction or inhibition.
- 1 August 2025
- Published by American Chemical Society (ACS) in Environment & Health
- Vol. 3  (12) , 1510-1520
Open AccessExploring the Antagonistic Effects of Bisphenols with Nonmonotonic Dose–Response Curves on the Estrogen Receptor
The nonmonotonic dose–response curve (NMDRC) is a prevalent characteristic of endocrine-disrupting chemicals (EDCs) in activating nuclear receptors (NRs), implicating intricate regulatory mechanisms. In this study, the agonistic and antagonistic activities of 11 bisphenols on the estrogen receptor (ER) were screened using MVLN cells. Three distinct dose–response patterns were observed, namely, S-shaped, inverted S-shaped, and bell-shaped profiles, corresponding to the agonistic, antagonistic, and nonmonotonic effects on ERs, respectively. To further explore NMDRC, bisphenol B (BPB) and bisphenol AF (BPAF), as representative compounds, were specifically investigated for their antagonistic effects on ER under high exposure concentrations (10–50 μmol/L). Notably, the successive decline in cell viability suggested a subhealthy cell state upon high-dose chemical treatments, compromising cell response in ER transactivation. Unlike the specific effect induced by an ERα antagonist (4-hydroxytamoxifen, 4OHT), the nonspecific inhibitory effects of BPB and BPAF on ER transactivation were further confirmed with their identical antagonistic curves, with or without E2 cotreatment, due to hydrophobicity-related cellular baseline toxicity. Accordingly, the inhibitory effects on NR transactivation might not necessarily be considered as a specific antagonistic activity. Thus, a more cautious inspection is highly encouraged in screening NR antagonism-centered endocrine-disrupting effects of emerging chemicals by carefully reviewing the specificity of signal reduction or inhibition.
- 14 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97  (20) , 10867-10876
Accurate Quantification of Metals in Individual Synechocystis sp. PCC 6803 Cells by Single-Cell ICP-MS: Dual-Calibration and Sample Stabilization Strategies
Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) is an emerging technique to investigate metal heterogeneity in individual cells. However, due to the absence of consistent calibration and suitable stabilization strategy for cells, accurate quantification of cellular heterogeneity and the content of metals remains a challenge. Herein, an accurate quantification method for the content and heterogeneous distribution of metals among individual microalgae cells was developed based on SC-ICP-MS using dual-calibration strategies and robust pretreatment methods. Gold nanoparticles (AuNPs) were used as calibration for measuring metal contents in single cells, but it would lead to a 13.6-63.1% underestimation of cell numbers due to inaccurate detection of cells' transport efficiency. To avoid this inaccuracy, we proposed an additional calibration strategy to measure cellular transport efficiency and cell numbers using endogenous Mg, enabling a more accurate assessment of cell heterogeneity. Then, an effective pretreatment method was optimized through fixation of cells with glutaraldehyde for 1 h to maintain the cellular stability and obtain accurate results, with satisfactory recoveries for cell number (98.4%) and Mg contents (91.7%), even after long-time storage. After optimization, the proposed method showed high sensitivity and repeatability in both cellular metal contents (Mg, Hg, Cd, and Co) and cell number, with detection limits (LODs) to be 0.14-0.53 fg/cell and 5.5 × 103 cells/mL, respectively. Finally, the proposed method was successfully used for detecting various metals and their heterogeneity in Synechocystis sp. PCC 6803 cells provided an accurate and robust tool for investigating the uptake and heterogeneous distribution of metals in microalgae.
- 14 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97  (20) , 10867-10876
Accurate Quantification of Metals in Individual Synechocystis sp. PCC 6803 Cells by Single-Cell ICP-MS: Dual-Calibration and Sample Stabilization Strategies
Single-cell inductively coupled plasma mass spectrometry (SC-ICP-MS) is an emerging technique to investigate metal heterogeneity in individual cells. However, due to the absence of consistent calibration and suitable stabilization strategy for cells, accurate quantification of cellular heterogeneity and the content of metals remains a challenge. Herein, an accurate quantification method for the content and heterogeneous distribution of metals among individual microalgae cells was developed based on SC-ICP-MS using dual-calibration strategies and robust pretreatment methods. Gold nanoparticles (AuNPs) were used as calibration for measuring metal contents in single cells, but it would lead to a 13.6-63.1% underestimation of cell numbers due to inaccurate detection of cells' transport efficiency. To avoid this inaccuracy, we proposed an additional calibration strategy to measure cellular transport efficiency and cell numbers using endogenous Mg, enabling a more accurate assessment of cell heterogeneity. Then, an effective pretreatment method was optimized through fixation of cells with glutaraldehyde for 1 h to maintain the cellular stability and obtain accurate results, with satisfactory recoveries for cell number (98.4%) and Mg contents (91.7%), even after long-time storage. After optimization, the proposed method showed high sensitivity and repeatability in both cellular metal contents (Mg, Hg, Cd, and Co) and cell number, with detection limits (LODs) to be 0.14-0.53 fg/cell and 5.5 × 103 cells/mL, respectively. Finally, the proposed method was successfully used for detecting various metals and their heterogeneity in Synechocystis sp. PCC 6803 cells provided an accurate and robust tool for investigating the uptake and heterogeneous distribution of metals in microalgae.
- 15 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97  (3) , 1792-1798
Particle Trajectory Simulation Facilitates the Development of an Efficient Sample Introduction System for Single-Particle ICP-MS Analysis
Inductively coupled plasma mass spectrometry (ICP-MS) has demonstrated significant capabilities in the analysis of single events, such as single cells and particles. Researchers have been actively pursuing innovations in ICP-MS sample introduction systems to enhance their transport efficiency, as this is critical for ensuring the accuracy of single-event analysis. However, the majority of prior studies have relied heavily on empirical approaches, with limited attention given to the individual characteristics of particles from a theoretical perspective and a lack of efficient manufacturing tools for optimizing related components. Herein, we developed a high-efficiency sample introduction system for single-event ICP-MS analysis by integrating the computational simulation-aided design, precise 3D printing manufacturing, and rapid experimental testing process. For the first time, we simulated the transport trajectories of individual particles passing through the spray chamber, providing theoretical guidance for the design and optimization process. The statistical analysis of particle trajectories revealed that under the absorption boundary condition, particles between 20 and 100 nm achieved transport efficiencies exceeding 18.8%. In comparison, particles larger than 100 nm exhibited 0% transport efficiency due to increased deposition within the spray chamber. The spray chamber was fabricated in-house using a range of 3D printing technologies and materials, streamlining the process and reducing the cost for both manufacturing and validation. Further optimization of the operating parameters, including an increase in temperature, resulted in a notable transport efficiency of 61.1%. The workflow introduced in this study has the potential to transform the research and development of critical mass spectrometry components moving forward.
- 15 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97  (3) , 1792-1798
Particle Trajectory Simulation Facilitates the Development of an Efficient Sample Introduction System for Single-Particle ICP-MS Analysis
Inductively coupled plasma mass spectrometry (ICP-MS) has demonstrated significant capabilities in the analysis of single events, such as single cells and particles. Researchers have been actively pursuing innovations in ICP-MS sample introduction systems to enhance their transport efficiency, as this is critical for ensuring the accuracy of single-event analysis. However, the majority of prior studies have relied heavily on empirical approaches, with limited attention given to the individual characteristics of particles from a theoretical perspective and a lack of efficient manufacturing tools for optimizing related components. Herein, we developed a high-efficiency sample introduction system for single-event ICP-MS analysis by integrating the computational simulation-aided design, precise 3D printing manufacturing, and rapid experimental testing process. For the first time, we simulated the transport trajectories of individual particles passing through the spray chamber, providing theoretical guidance for the design and optimization process. The statistical analysis of particle trajectories revealed that under the absorption boundary condition, particles between 20 and 100 nm achieved transport efficiencies exceeding 18.8%. In comparison, particles larger than 100 nm exhibited 0% transport efficiency due to increased deposition within the spray chamber. The spray chamber was fabricated in-house using a range of 3D printing technologies and materials, streamlining the process and reducing the cost for both manufacturing and validation. Further optimization of the operating parameters, including an increase in temperature, resulted in a notable transport efficiency of 61.1%. The workflow introduced in this study has the potential to transform the research and development of critical mass spectrometry components moving forward.