Dagmara Kotrys-Działak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dagmara Kotrys-Działak has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Katarzyna Stokowiec
Kielce University of Technology, Poland
3 shared publications - Sylwia Wciślik
Faculty of Environmental Engineering, Geomatics and Renewable Energy, Kielce University of Technology, Al. Tysiąclecia P.P. 7, 25-314 Kielce, Poland
3 shared publications Dominika Mochocka
Kielce University of Technology, Faculty of Environmental Engineering, Geomatics and Power Engineering, 25-314 Kielce, Poland
1 shared publicationKatarzyna Stokowiec
Kielce University of Technology, Faculty of Environmental Engineering, Geomatics and Power Engineering, 25-314 Kielce, Poland
1 shared publicationMarcin Sokołowski
Kielce University of Technology, Faculty of Environmental Engineering, Geomatics and Power Engineering, 25-314 Kielce, Poland
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Walter de Gruyter GmbH in Environmental and Climate Technologies
- Vol. 30 (1) , 122-141
Efficiency of Heat Exchanger Systems Working with Nanofluids
This paper presents a literature based comparative analysis of the heat transfer performance of heat exchanger systems operating with nanofluids. The study synthesizes and compares the results reported in published experimental and numerical works for different types of heat exchangers: shell and tube and plate heat exchangers. The comparison is based on key parameters including exergy efficiency ηex, overall heat transfer coefficient U , and effectiveness ε. The results are presented as functions of the Reynolds number for laminar, transitional, and turbulent flow regimes, and for different types of nanofluids, including both mono and hybrid suspensions. The analysis shows that WC/DI nanofluids provide the highest overall heat transfer coefficient in plate heat exchangers with U = 1110 W/(m2K) at Re = 525, while 0.1 % Graphene/DI nanofluids achieve the best thermal performance in shell and tube heat exchangers exceeding U values of 0.4 % Fe3O4/DI:EG and 0.4 % ND/DI:EG by 85 W/(m2K) at Re = 3000. For plate heat exchangers 0.4 % ND/DI nanofluid demonstrate the highest effectiveness with ε equals to 62 % at Re = 570, whereas in shell and tube designs the best performance is obtained for 0.1 % GNP nanofluid with effectiveness reaching approximately 97.5 % at Re = 500. Furthermore, the Cu:ZnO/DI hybrid nanofluid achieved the highest exergy efficiency 66 % while other hybrid nanofluids exhibits exergy efficiencies lower by 31–34 % at a comparable Reynolds number. The results confirm the significant influence of nanofluid composition and Reynolds number in optimizing heat transfer efficiency.
- 1 January 2026
- Published by Walter de Gruyter GmbH in Environmental and Climate Technologies
- Vol. 30 (1) , 122-141
Open AccessEfficiency of Heat Exchanger Systems Working with Nanofluids
This paper presents a literature based comparative analysis of the heat transfer performance of heat exchanger systems operating with nanofluids. The study synthesizes and compares the results reported in published experimental and numerical works for different types of heat exchangers: shell and tube and plate heat exchangers. The comparison is based on key parameters including exergy efficiency ηex, overall heat transfer coefficient U , and effectiveness ε. The results are presented as functions of the Reynolds number for laminar, transitional, and turbulent flow regimes, and for different types of nanofluids, including both mono and hybrid suspensions. The analysis shows that WC/DI nanofluids provide the highest overall heat transfer coefficient in plate heat exchangers with U = 1110 W/(m2K) at Re = 525, while 0.1 % Graphene/DI nanofluids achieve the best thermal performance in shell and tube heat exchangers exceeding U values of 0.4 % Fe3O4/DI:EG and 0.4 % ND/DI:EG by 85 W/(m2K) at Re = 3000. For plate heat exchangers 0.4 % ND/DI nanofluid demonstrate the highest effectiveness with ε equals to 62 % at Re = 570, whereas in shell and tube designs the best performance is obtained for 0.1 % GNP nanofluid with effectiveness reaching approximately 97.5 % at Re = 500. Furthermore, the Cu:ZnO/DI hybrid nanofluid achieved the highest exergy efficiency 66 % while other hybrid nanofluids exhibits exergy efficiencies lower by 31–34 % at a comparable Reynolds number. The results confirm the significant influence of nanofluid composition and Reynolds number in optimizing heat transfer efficiency.
- Open Access
- 24 April 2024
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 26, 128-136
The Effect of the Temperature Increase on Heat Demand Calculation for Building in the Polish Climatology
The Effect of the Temperature Increase on Heat Demand Calculation for Building in the Polish Climatology
- 24 April 2024
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 26, 128-136
Open AccessThe Effect of the Temperature Increase on Heat Demand Calculation for Building in the Polish Climatology
The Effect of the Temperature Increase on Heat Demand Calculation for Building in the Polish Climatology
- 1 April 2023
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 25, 37-44
Temperature Distribution Analysis on the Surface of the Radiator: Infrared Camera and Thermocouples Results Comparison
The experiments conducted in a didactic laboratory of the Kielce University of Technology involved temperature distribution measurements on the outer surface of a steel radiator using a thermal imaging camera and thermocouples to compare both investigation methods. The research included registering the parameters for a specific period for each of the four different medium flows. Graphs present the results with the division of the radiator into eight thermal fields. The results present the differences in temperatures between 1.78°C to 3.65°C. The non-contact method with an infrared camera seems more accurate since it is precise for surface temperature measurement.
- 1 April 2023
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 25, 37-44
Temperature Distribution Analysis on the Surface of the Radiator: Infrared Camera and Thermocouples Results Comparison
The experiments conducted in a didactic laboratory of the Kielce University of Technology involved temperature distribution measurements on the outer surface of a steel radiator using a thermal imaging camera and thermocouples to compare both investigation methods. The research included registering the parameters for a specific period for each of the four different medium flows. Graphs present the results with the division of the radiator into eight thermal fields. The results present the differences in temperatures between 1.78°C to 3.65°C. The non-contact method with an infrared camera seems more accurate since it is precise for surface temperature measurement.
- Open Access
- 3 February 2023
- Published by MDPI AG in Inventions
- Vol. 8 (1) , 43
Innovative Modernization of Building Heating Systems: The Economy and Ecology of a Hybrid District-Heating Substation
Hybrid installations with respect to renewable energy sources are becoming more popular due to the stringent requirements for the energy efficiency of buildings. Therefore, the thermomodernization of a district-heating substation was proposed. Several scenarios, including different renewable energies (an air–water heat pump versus a heat pump with photovoltaics), different investment financing (equity or bank credit), and different purposes for heating demand (central heating or central heating with ventilation and domestic hot water), were analyzed. The economic aspects involved the calculations of the payback time and net present value, while the ecological and environmental characteristics were weighed using emission reduction. Each of the analyses resulted in different proposed modernization methods. However, taking both factors together, the computations proved that the most profitable was the scenario with energy demand for heating, domestic hot water, and ventilation purposes financed by means of bank credit with a thermomodernization bonus.
- 3 February 2023
- Published by MDPI AG in Inventions
- Vol. 8 (1) , 43
Open AccessInnovative Modernization of Building Heating Systems: The Economy and Ecology of a Hybrid District-Heating Substation
Hybrid installations with respect to renewable energy sources are becoming more popular due to the stringent requirements for the energy efficiency of buildings. Therefore, the thermomodernization of a district-heating substation was proposed. Several scenarios, including different renewable energies (an air–water heat pump versus a heat pump with photovoltaics), different investment financing (equity or bank credit), and different purposes for heating demand (central heating or central heating with ventilation and domestic hot water), were analyzed. The economic aspects involved the calculations of the payback time and net present value, while the ecological and environmental characteristics were weighed using emission reduction. Each of the analyses resulted in different proposed modernization methods. However, taking both factors together, the computations proved that the most profitable was the scenario with energy demand for heating, domestic hot water, and ventilation purposes financed by means of bank credit with a thermomodernization bonus.
- Open Access
- 14 April 2022
- Published by EDP Sciences
- Vol. 347, 04017
Thermovision analysis of heat and power plant chimneys technical condition
This paper describes the thermovision analysis conducted on two types of chimneys: structural steel one and reinforced concrete one located in Kielce Heat and Power Plant, Poland. As a result of the research temperature distribution obtained from the thermograms were shown on the diagrams and analysed along their horizontal direction. It proves, both of the chimneys that were examined are in proper technical condition. The article also discusses the importance of the analysis as a diagnostic tool that allows early-stage detection of structural technical conditions and thermal insulation degradation. A factory’s chimney should work constantly to maintain its operation, since modifications in the production line caused by construction works are high cost and usually difficult to implement. However, analyses are critical to ensure chimneys are well maintained. The literature presents many examples of destructive influence of high temperature on the reinforced concrete chimneys. When failure of chimneys occurs, even the whole plant unit may be closed down. Thermography is then an ideal, non-destructive and cost-effective instrument for structure testing and can therefore be a useful, initial step to locate potential damage.
- 14 April 2022
- Published by EDP Sciences
- Vol. 347, 04017
Open AccessThermovision analysis of heat and power plant chimneys technical condition
This paper describes the thermovision analysis conducted on two types of chimneys: structural steel one and reinforced concrete one located in Kielce Heat and Power Plant, Poland. As a result of the research temperature distribution obtained from the thermograms were shown on the diagrams and analysed along their horizontal direction. It proves, both of the chimneys that were examined are in proper technical condition. The article also discusses the importance of the analysis as a diagnostic tool that allows early-stage detection of structural technical conditions and thermal insulation degradation. A factory’s chimney should work constantly to maintain its operation, since modifications in the production line caused by construction works are high cost and usually difficult to implement. However, analyses are critical to ensure chimneys are well maintained. The literature presents many examples of destructive influence of high temperature on the reinforced concrete chimneys. When failure of chimneys occurs, even the whole plant unit may be closed down. Thermography is then an ideal, non-destructive and cost-effective instrument for structure testing and can therefore be a useful, initial step to locate potential damage.
- Open Access
- 6 September 2021
- Published by Springer Nature in Energy Efficiency
- Vol. 14 (7) , 1-22
Thermal building upgrade with off-grid PV system: a Polish case
Nowadays, one of the basic requirements for thermally upgraded buildings involves limitation in CO2 emission even by over 90%. To fulfil these criteria, it is necessary to use alternative energy sources and photovoltaics constitutes a reasonable option for this. This paper addresses an analysis of the efficiency and profitability of a photovoltaic system located in the geometric center of Europe-Poland, where the intensity of solar irradiation is not very high compared to other European countries. The difference of total solar radiation density between Poland and Malta is 49.2%, from analysis based on SolarGIS base. The PV Lighthouse calculator was used for global power density and photon current examination for a Polish city and locations of the highest and the lowest solar radiation values, Malta and Finland, respectively. This case study concerns a thermally upgraded building; a gas boiler was replaced by a heat pump supported by an off-grid PV system. To achieve a reduction in CO2 emission of 90%, it is necessary to install 182 PV cells, which generates high investment costs. An investment is entirely profitable with 70% of funding with Simple Pay Back Time, SPBT~7 years although Net Present Value, NPV>0; Internal Rate of Return, IRR=10.6%.
- 6 September 2021
- Published by Springer Nature in Energy Efficiency
- Vol. 14 (7) , 1-22
Open AccessThermal building upgrade with off-grid PV system: a Polish case
Nowadays, one of the basic requirements for thermally upgraded buildings involves limitation in CO2 emission even by over 90%. To fulfil these criteria, it is necessary to use alternative energy sources and photovoltaics constitutes a reasonable option for this. This paper addresses an analysis of the efficiency and profitability of a photovoltaic system located in the geometric center of Europe-Poland, where the intensity of solar irradiation is not very high compared to other European countries. The difference of total solar radiation density between Poland and Malta is 49.2%, from analysis based on SolarGIS base. The PV Lighthouse calculator was used for global power density and photon current examination for a Polish city and locations of the highest and the lowest solar radiation values, Malta and Finland, respectively. This case study concerns a thermally upgraded building; a gas boiler was replaced by a heat pump supported by an off-grid PV system. To achieve a reduction in CO2 emission of 90%, it is necessary to install 182 PV cells, which generates high investment costs. An investment is entirely profitable with 70% of funding with Simple Pay Back Time, SPBT~7 years although Net Present Value, NPV>0; Internal Rate of Return, IRR=10.6%.
- Open Access
- 3 November 2020
- Published by MDPI AG in Preprints.org
The Energy, Economic and Environmental Efficiency of a PV Installation Cooperating with a Heat Pumpin the Central Part of Europe. Case study
The paper addresses an analysis of the efficiency and profitability of the operation of a photovoltaic installation located in the geometric centre of Europe (near Białystok, Poland), where the intensity of solar irradiation is not too high compared to other European countries. It is calculated that in that place average solar irradiation being lower even by approx. 26 kWh than that for the whole Europe, which results in a 26% drop in the economic potential of the utilisation of solar energy for its conversion. A case study and an economic analysis show that without minimum funding amounting to 50% of the investment costs paid for the modernisation of a central heating system assisted by PV cells, the time of return of pecuniary expenditures exceeds 7 years. Apart from the Simple Pay-Back Time SPBT, discount indicators determined in the paper also include the net present value NPV and the internal rate of return IRR. Moreover, a direct ecological effect has been determined for such an investment.
- 3 November 2020
- Published by MDPI AG in Preprints.org
Open AccessThe Energy, Economic and Environmental Efficiency of a PV Installation Cooperating with a Heat Pumpin the Central Part of Europe. Case study
The paper addresses an analysis of the efficiency and profitability of the operation of a photovoltaic installation located in the geometric centre of Europe (near Białystok, Poland), where the intensity of solar irradiation is not too high compared to other European countries. It is calculated that in that place average solar irradiation being lower even by approx. 26 kWh than that for the whole Europe, which results in a 26% drop in the economic potential of the utilisation of solar energy for its conversion. A case study and an economic analysis show that without minimum funding amounting to 50% of the investment costs paid for the modernisation of a central heating system assisted by PV cells, the time of return of pecuniary expenditures exceeds 7 years. Apart from the Simple Pay-Back Time SPBT, discount indicators determined in the paper also include the net present value NPV and the internal rate of return IRR. Moreover, a direct ecological effect has been determined for such an investment.