Peer Schrader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peer Schrader has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Stefan Kolling
Institute of Mechanics and Materials, Technische Hochschule Mittelhessen
4 shared publications- Alexander Schmidt
Department of Prosthodontics, Dental Clinic, Justus Liebig University, Schlangenzahl 14, 35392 Giessen, Germany
3 shared publications Bernd Wöstmann
Department of Prosthodontics, Dental Clinic, Justus-Liebig-University
3 shared publications- Stephan Marzi
Institute of Mechanics and Materials, Technische Hochschule Mittelhessen, University of Applied Sciences, Wiesenstraße 14, 35390 Gießen, Germany
3 shared publications Maximiliane Amelie Schlenz
Department of Prosthodontics, Dental Clinic, Justus-Liebig-University
2 shared publicationsStephan Marzi
2 shared publications
Latest Publications
- Open Access
Influence of Loading Rate on the Cohesive Traction for Soft, Rubber-Like Adhesive Layers Loaded in Modes I and III
To date, the fracture behaviour of soft, polyurethane-based adhesive joints has rarely been investigated. This work contributes to the experimental investigation of such joints in modes I and III by performing double cantilever beam (mode I) and out-of-plane loaded double cantilever beam (mode III) tests at various loading rates. The tests were evaluated using a J-integral method, which is well established for testing stiff adhesive layers and is conventionally used to determine the cohesive traction at the crack tip. Additionally, fibre-optics measurements were conducted to provide crack extension, process zone length, and cohesive traction from the measured backface strain of the adherends. It was found that the energy release rate seems to be largely independent of the loading mode. However, differences were observed regarding process zone length and resistance curve behaviour. Furthermore, the backface strain measurement allows the determination of the cohesive traction along with the complete adhesive layer as well as separation and separation rate, yielding rate-dependent cohesive laws. A comparison indicated that the cohesive traction obtained from the J-integral method does not match the measured benchmark from the backface strain measurements because the underlying theoretical assumptions of the J-integral method are likely violated for soft, rubber-like adhesive joints.
Open AccessInfluence of Loading Rate on the Cohesive Traction for Soft, Rubber-Like Adhesive Layers Loaded in Modes I and III
To date, the fracture behaviour of soft, polyurethane-based adhesive joints has rarely been investigated. This work contributes to the experimental investigation of such joints in modes I and III by performing double cantilever beam (mode I) and out-of-plane loaded double cantilever beam (mode III) tests at various loading rates. The tests were evaluated using a J-integral method, which is well established for testing stiff adhesive layers and is conventionally used to determine the cohesive traction at the crack tip. Additionally, fibre-optics measurements were conducted to provide crack extension, process zone length, and cohesive traction from the measured backface strain of the adherends. It was found that the energy release rate seems to be largely independent of the loading mode. However, differences were observed regarding process zone length and resistance curve behaviour. Furthermore, the backface strain measurement allows the determination of the cohesive traction along with the complete adhesive layer as well as separation and separation rate, yielding rate-dependent cohesive laws. A comparison indicated that the cohesive traction obtained from the J-integral method does not match the measured benchmark from the backface strain measurements because the underlying theoretical assumptions of the J-integral method are likely violated for soft, rubber-like adhesive joints.
- 25 November 2022
- Published by Elsevier in Theoretical and Applied Fracture Mechanics
- Vol. 123, 103699
Novel mode III DCB test setups and related evaluation methods to investigate the fracture behaviour of adhesive joints
- 25 November 2022
- Published by Elsevier in Theoretical and Applied Fracture Mechanics
- Vol. 123, 103699
Novel mode III DCB test setups and related evaluation methods to investigate the fracture behaviour of adhesive joints
- 1 March 2022
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 113
Mode I creep fracture of rubber-like adhesive joints at constant crack driving force
- 1 March 2022
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 113
Mode I creep fracture of rubber-like adhesive joints at constant crack driving force
- 1 March 2022
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 113
Mode III testing of structural adhesive joints at elevated loading rates
- 1 March 2022
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 113
Mode III testing of structural adhesive joints at elevated loading rates
- 25 July 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (4) , 894-902
Finite element simulation of fixed dental prostheses made from PMMA —Part II: Material modeling and nonlinear finite element analysis
Material characteristics can change significantly with increasing chewing velocity. As these in-vitro examinations are very time-consuming and cost-intensive, the application of finite element analysis (FEA) offers a suitable alternative for predicting the material behavior of complex specimen geometries under clinically relevant loads. Although FEA is applied within numerous dental investigations, there are only few studies available in which a nonlinear FEA is validated with real experiments. Therefore, the aim of the present study was to predict the mechanical behavior of a clinically close three-unit temporary bridge composed of polymethyl methacrylate (PMMA) in the left upper jaw with nonlinear FEA and to verify the prediction through validation experiments. In conclusion, simplifying assumptions of linear elastic material properties for polymeric materials should be avoided in FEA studies, because rate dependencies, stress relaxation and plastic flow are not considered. Additionally, precise preliminary investigations for material characterization are necessary.
- 25 July 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (4) , 894-902
Finite element simulation of fixed dental prostheses made from PMMA —Part II: Material modeling and nonlinear finite element analysis
Material characteristics can change significantly with increasing chewing velocity. As these in-vitro examinations are very time-consuming and cost-intensive, the application of finite element analysis (FEA) offers a suitable alternative for predicting the material behavior of complex specimen geometries under clinically relevant loads. Although FEA is applied within numerous dental investigations, there are only few studies available in which a nonlinear FEA is validated with real experiments. Therefore, the aim of the present study was to predict the mechanical behavior of a clinically close three-unit temporary bridge composed of polymethyl methacrylate (PMMA) in the left upper jaw with nonlinear FEA and to verify the prediction through validation experiments. In conclusion, simplifying assumptions of linear elastic material properties for polymeric materials should be avoided in FEA studies, because rate dependencies, stress relaxation and plastic flow are not considered. Additionally, precise preliminary investigations for material characterization are necessary.
- 25 May 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (3) , 704-711
Finite element simulation of fixed dental prostheses made from PMMA —Part I: Experimental investigation under quasi-static loading and chewing velocities
Material properties are of high clinical relevance, even though in vitro laboratory setups may differ from clinical conditions. Therefore, the aim of the present study was to investigate the fracture behavior of three-unit bridge restoration (Telio CAD) with different test velocities (1.0 mm/min International Organization for Standardization (ISO) standard speed/ 130 mm/s mean chewing velocity) and to provide crucial validation experiments for the upcoming Part 2 of our study, in which FEA on such temporary restorations will be conducted. Local strains were detected using digital image correlation (DIC). The material exhibited significantly different responses at different test velocities, and the forces at fracture were found to be much smaller at chewing velocity (130 mm/s) than in the quasi-static test. Overall, the results of the present study show that characteristics pertaining to material behavior can change significantly with increasing chewing velocity, and that fracture forces decrease with increasing test velocity.
- 25 May 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (3) , 704-711
Finite element simulation of fixed dental prostheses made from PMMA —Part I: Experimental investigation under quasi-static loading and chewing velocities
Material properties are of high clinical relevance, even though in vitro laboratory setups may differ from clinical conditions. Therefore, the aim of the present study was to investigate the fracture behavior of three-unit bridge restoration (Telio CAD) with different test velocities (1.0 mm/min International Organization for Standardization (ISO) standard speed/ 130 mm/s mean chewing velocity) and to provide crucial validation experiments for the upcoming Part 2 of our study, in which FEA on such temporary restorations will be conducted. Local strains were detected using digital image correlation (DIC). The material exhibited significantly different responses at different test velocities, and the forces at fracture were found to be much smaller at chewing velocity (130 mm/s) than in the quasi-static test. Overall, the results of the present study show that characteristics pertaining to material behavior can change significantly with increasing chewing velocity, and that fracture forces decrease with increasing test velocity.
- 25 January 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (1) , 52-60
Is the assumption of linear elasticity within prosthodontics valid for polymers? —An exemplary study of possible problems
As shown in previous studies within other scientific fields, the material behavior of polymethyl methacrylate (PMMA) is viscoelastic-viscoplastic. However, in dental biomaterial science it is mostly considered as linear elastic or elastic-plastic. The aim of the present study was to evaluate, whether the assumption of elastic or elastic-plastic material behavior for PMMA is a practicable simplification or a potential source of error, especially considering clinical loading conditions. Telio-CAD was tested in three-point bending tests with different test velocities to examine the material behavior at different initial loading rates. Additionally, a dynamic-mechanical-thermal-analysis at different frequencies and temperatures was used. Here, a significant influence of loading rate and temperature as well as stress relaxation and creep were observed. To describe the rate-dependency of the elastic modulus, a new model was created, from which the elastic modulus can be calculated with a given strain rate. This model was validated using linear elastic finite element analysis.
- 25 January 2021
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 40 (1) , 52-60
Is the assumption of linear elasticity within prosthodontics valid for polymers? —An exemplary study of possible problems
As shown in previous studies within other scientific fields, the material behavior of polymethyl methacrylate (PMMA) is viscoelastic-viscoplastic. However, in dental biomaterial science it is mostly considered as linear elastic or elastic-plastic. The aim of the present study was to evaluate, whether the assumption of elastic or elastic-plastic material behavior for PMMA is a practicable simplification or a potential source of error, especially considering clinical loading conditions. Telio-CAD was tested in three-point bending tests with different test velocities to examine the material behavior at different initial loading rates. Additionally, a dynamic-mechanical-thermal-analysis at different frequencies and temperatures was used. Here, a significant influence of loading rate and temperature as well as stress relaxation and creep were observed. To describe the rate-dependency of the elastic modulus, a new model was created, from which the elastic modulus can be calculated with a given strain rate. This model was validated using linear elastic finite element analysis.
- Open Access
Fracture of Thin-Walled Polyoxymethylene Bulk Specimens in Modes I and III
Thin-walled polymeric components are used in many applications. Hence, knowledge about their fracture behavior in bulk is beneficial in practice. Within this study, the double cantilever beam (DCB) and out-of-plane double cantilever beam (ODCB) tests are enhanced to enable the testing of such bulk specimens in mode I and mode III on the basis of the J-integral. This paper then presents and discusses the experimental results following the investigation of a semicrystalline polymer (polyoxymethylen) under quasi-static load conditions. From the experiments, fracture energies of similar magnitude in both mode I and mode III were determined. In mode III, pop-in fracture was observed. Furthermore, the fracture surfaces were investigated regarding the mode I and mode III dominant crack growth mechanisms, based on the morphology of the tested material. For specimens tested in mode I, no signs of plastic deformation were observed, and the fracture surface appears flat. In mode III, some samples display a twisted fracture surface (twisting angle close to 45), which indicates local mode I crack growth. A transfer of the presented methodology to other (more ductile) polymeric materials is deemed possible without further restrictions. In addition, the presented setup potentially enables an investigation of polymeric bulk specimens in mixed mode I+III.Open AccessFracture of Thin-Walled Polyoxymethylene Bulk Specimens in Modes I and III
Thin-walled polymeric components are used in many applications. Hence, knowledge about their fracture behavior in bulk is beneficial in practice. Within this study, the double cantilever beam (DCB) and out-of-plane double cantilever beam (ODCB) tests are enhanced to enable the testing of such bulk specimens in mode I and mode III on the basis of the J-integral. This paper then presents and discusses the experimental results following the investigation of a semicrystalline polymer (polyoxymethylen) under quasi-static load conditions. From the experiments, fracture energies of similar magnitude in both mode I and mode III were determined. In mode III, pop-in fracture was observed. Furthermore, the fracture surfaces were investigated regarding the mode I and mode III dominant crack growth mechanisms, based on the morphology of the tested material. For specimens tested in mode I, no signs of plastic deformation were observed, and the fracture surface appears flat. In mode III, some samples display a twisted fracture surface (twisting angle close to 45), which indicates local mode I crack growth. A transfer of the presented methodology to other (more ductile) polymeric materials is deemed possible without further restrictions. In addition, the presented setup potentially enables an investigation of polymeric bulk specimens in mixed mode I+III. Fraktographische Bruchspannungs‐Analyse von Acrylglas
Durch fraktographische Analysen der Bruchflächen spröder Werkstoffe ist es anhand der im Versagensursprung entstehenden Bruchspiegel möglich, eine Aussage über die Bruchspannung zu treffen. Im vorliegenden Artikel wird diese Methodik auf nicht‐ideal‐spröde Werkstoffe am Beispiel von PMMA (Acrylglas bzw. Plexiglas®) angewendet und eine Vorgehensweise zur Bestimmung der materialabhängigen Bruchspiegelkonstanten vorgestellt. Hierzu werden an über 50 Zugproben die Bruchspiegelradien vermessen und ausgewertet. Mittels digitaler Bildkorrelation wird das nicht lineare Spannungs‐Dehnungs‐Verhalten von PMMA ermittelt und daraus die Versagensspannungen bestimmt. Zur Validierung der Bruchspiegelanalyse an PMMA wird die resultierende statistische Bruchspannungsverteilung mit der aus einer digitalen Bildkorrelation gewonnenen Verteilung verglichen. Das vorgestellte Verfahren erlaubt es, die Bruchspannung auch für komplexe Bauteilgeometrien nach bereits erfolgtem Versagen zu bestimmen.
Fraktographische Bruchspannungs‐Analyse von Acrylglas
Durch fraktographische Analysen der Bruchflächen spröder Werkstoffe ist es anhand der im Versagensursprung entstehenden Bruchspiegel möglich, eine Aussage über die Bruchspannung zu treffen. Im vorliegenden Artikel wird diese Methodik auf nicht‐ideal‐spröde Werkstoffe am Beispiel von PMMA (Acrylglas bzw. Plexiglas®) angewendet und eine Vorgehensweise zur Bestimmung der materialabhängigen Bruchspiegelkonstanten vorgestellt. Hierzu werden an über 50 Zugproben die Bruchspiegelradien vermessen und ausgewertet. Mittels digitaler Bildkorrelation wird das nicht lineare Spannungs‐Dehnungs‐Verhalten von PMMA ermittelt und daraus die Versagensspannungen bestimmt. Zur Validierung der Bruchspiegelanalyse an PMMA wird die resultierende statistische Bruchspannungsverteilung mit der aus einer digitalen Bildkorrelation gewonnenen Verteilung verglichen. Das vorgestellte Verfahren erlaubt es, die Bruchspannung auch für komplexe Bauteilgeometrien nach bereits erfolgtem Versagen zu bestimmen.