Andriy Rebryk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andriy Rebryk has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Peter Haglund
Department of Chemistry, Chemical Biological Centre (KBC), Umeå University , Linnaeus väg 6, 901 87 Umeå
5 shared publications- Belgin Gözmen
Department of Chemistry, Faculty of Science, Mersin University, Mersin 33343, Türkiye
1 shared publication Christine Gallampois
Department of Chemistry, Chemical Biological Centre (KBC), Umeå University, Linnaeus väg 6, 901 87 Umeå, Sweden
1 shared publicationDenice van Herwerden
Van ’t Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam , 1090 GD Amsterdam
1 shared publication- Dimitrios Kalderis
Department of Electronic Engineering, Hellenic Mediterranean University, 73100 Chania, Greece
1 shared publication - Ivan Hetman
Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, Norrköping SE-601 74, Sweden; Clinical Department of Occupational and Environmental Medicine, Region Östergötland, SE-581 85 Linköping, Sweden
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Oxford University Press (OUP) in Briefings in Bioinformatics
- Vol. 27 (5)
Evaluation of peak alignment performance of commercial and open-source tools for GC×GC–MS based non-targeted screening
Comprehensive two-dimensional gas chromatography–mass spectrometry (GC × GC–MS) is a powerful tool for analysing complex mixtures, but its wide use is limited by the lack of robust and transparent inter-sample peak alignment workflows. Commercial solutions often rely on proprietary algorithms, while user-friendly open-source alternatives remain scarce. Here, we introduce jAligner4GCxGC, a new open-access Julia package for inter-sample GC × GC–MS peak alignment and benchmark its performance within practical GC × GC–MS data processing workflows against Guineu (open-source) and ChromaTOF Sync 2D (commercial). The package performs data preprocessing, alignment, and postprocessing including feature merging, library searching, and compound data retrieval. Three indoor dust samples, including certified reference material, were spiked with >150 reference compounds at concentrations of 0.5, 5.0, and 50 pg/μl and analysed using workflows optimized for each application. Performance was evaluated based on recovery of correctly aligned spiked compounds and workflow processing time. Because the software packages differ in peak detection and preprocessing, comparisons involving Sync 2D should be interpreted at workflow rather than alignment algorithm level. At 50 pg/μl, Guineu and jAligner4GCxGC detected 94% and 92% of compounds, respectively, outperforming Sync 2D (82%). At 5 and 0.5 pg/μl, Sync 2D detected the highest proportions (79% and 71%), whereas Guineu and jAligner4GCxGC performed identically (68% and 33%). Alignment-related processing required seconds for Guineu, 4 min for jAligner4GCxGC, and 9 min for Sync 2D. However, Sync 2D provided the quickest end-to-end workflow. These results highlight practical trade-offs between commercial and open-source workflows and demonstrate that jAligner4GCxGC provides a transparent and reproducible solution for GC × GC–MS peak alignment.
- 1 September 2026
- Published by Oxford University Press (OUP) in Briefings in Bioinformatics
- Vol. 27 (5)
Open AccessEvaluation of peak alignment performance of commercial and open-source tools for GC×GC–MS based non-targeted screening
Comprehensive two-dimensional gas chromatography–mass spectrometry (GC × GC–MS) is a powerful tool for analysing complex mixtures, but its wide use is limited by the lack of robust and transparent inter-sample peak alignment workflows. Commercial solutions often rely on proprietary algorithms, while user-friendly open-source alternatives remain scarce. Here, we introduce jAligner4GCxGC, a new open-access Julia package for inter-sample GC × GC–MS peak alignment and benchmark its performance within practical GC × GC–MS data processing workflows against Guineu (open-source) and ChromaTOF Sync 2D (commercial). The package performs data preprocessing, alignment, and postprocessing including feature merging, library searching, and compound data retrieval. Three indoor dust samples, including certified reference material, were spiked with >150 reference compounds at concentrations of 0.5, 5.0, and 50 pg/μl and analysed using workflows optimized for each application. Performance was evaluated based on recovery of correctly aligned spiked compounds and workflow processing time. Because the software packages differ in peak detection and preprocessing, comparisons involving Sync 2D should be interpreted at workflow rather than alignment algorithm level. At 50 pg/μl, Guineu and jAligner4GCxGC detected 94% and 92% of compounds, respectively, outperforming Sync 2D (82%). At 5 and 0.5 pg/μl, Sync 2D detected the highest proportions (79% and 71%), whereas Guineu and jAligner4GCxGC performed identically (68% and 33%). Alignment-related processing required seconds for Guineu, 4 min for jAligner4GCxGC, and 9 min for Sync 2D. However, Sync 2D provided the quickest end-to-end workflow. These results highlight practical trade-offs between commercial and open-source workflows and demonstrate that jAligner4GCxGC provides a transparent and reproducible solution for GC × GC–MS peak alignment.
- Open Access
- 12 May 2026
- Published by Elsevier in Bioresource Technology
- Vol. 456, 134859
Insights into the mechanisms of volatile organic compounds formation during the hydrothermal carbonization of olive tree sawdust, rice husk and wine pomace
- 12 May 2026
- Published by Elsevier in Bioresource Technology
- Vol. 456, 134859
Open AccessInsights into the mechanisms of volatile organic compounds formation during the hydrothermal carbonization of olive tree sawdust, rice husk and wine pomace
- Open Access
- 17 August 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 897, 166282
Temporal trends of lipophilic organic contaminants in blue mussel (1994–2017) and eelpout (1994–2017) from the southern Baltic Sea
- 17 August 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 897, 166282
Open AccessTemporal trends of lipophilic organic contaminants in blue mussel (1994–2017) and eelpout (1994–2017) from the southern Baltic Sea
- Open Access
- 24 August 2022
- Published by Elsevier in Science of The Total Environment
- Vol. 851 (Pt 1) , 158280
Comprehensive non-target screening of biomagnifying organic contaminants in the Baltic Sea food web
- 24 August 2022
- Published by Elsevier in Science of The Total Environment
- Vol. 851 (Pt 1) , 158280
Open AccessComprehensive non-target screening of biomagnifying organic contaminants in the Baltic Sea food web
- Open Access
- 16 March 2022
- Published by Elsevier in Science of The Total Environment
- Vol. 829, 154620
A time-trend guided non-target screening study of organic contaminants in Baltic Sea harbor porpoise (1988–2019), guillemot (1986–2019), and white-tailed sea eagle (1965–2017) using gas chromatography–high-resolution mass spectrometry
- 16 March 2022
- Published by Elsevier in Science of The Total Environment
- Vol. 829, 154620
Open AccessA time-trend guided non-target screening study of organic contaminants in Baltic Sea harbor porpoise (1988–2019), guillemot (1986–2019), and white-tailed sea eagle (1965–2017) using gas chromatography–high-resolution mass spectrometry
- Open Access
- 6 November 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (2) , 479-501
Non-targeted screening workflows for gas chromatography–high-resolution mass spectrometry analysis and identification of biomagnifying contaminants in biota samples
The health of key species in the Baltic region has been impaired by exposure to anthropogenic hazardous substances (AHSs), which accumulate in organisms and are transferred through food chains. There is, thus, a need for comprehensive characterization of the occurrence and accumulation of AHSs in the ecosystem. In this study, we use a non-target screening (NTS) approach for this purpose. A major challenge in NTS of biological samples is the removal of matrix components such as lipids that may interfere with the detection and identification of compounds of interest. Here, we combine gel permeation chromatography with Florisil® column fractionation to achieve sufficient lipid removal for gas chromatography–high-resolution mass spectrometry analysis using electron ionization (EI) and electron capture negative ion chemical ionization (ECNI). In addition, we present new data processing workflows designed to systematically find and identify frequently occurring and biomagnifying AHSs, including known, emerging, and new contaminants. Using these workflows, we discovered a wide range of contaminants in tissue samples from blue mussels, fish, and marine mammals, and calculated their biomagnification factors (BMFs). Compounds with BMFs above 1 for herring and at least one marine mammal included legacy chlorinated pollutants (polychlorinated biphenyls, DDTs, chloro-benzenes/cyclohexanes, chlordanes, toxaphenes, dieldrin), polybrominated diphenyl ethers (PBDEs), and brominated biphenyls. However, there were also several halogenated natural products (halogenated methoxylated brominated diphenyl ethers, 1′-methyl-1,2′-bipyrroles, 1,1′-dimethyl-2,2′-bipyrroles, and the halogenated monoterpene mixed halogenated compound 1) as well as the novel flame retardant Dechlorane 602 and several polycyclic aromatic hydrocarbons, terpenoids, and steroids. The legacy pollutants exhibited the expected biomagnification behavior, demonstrating the utility of the unguided data processing workflow.
- 6 November 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (2) , 479-501
Open AccessNon-targeted screening workflows for gas chromatography–high-resolution mass spectrometry analysis and identification of biomagnifying contaminants in biota samples
The health of key species in the Baltic region has been impaired by exposure to anthropogenic hazardous substances (AHSs), which accumulate in organisms and are transferred through food chains. There is, thus, a need for comprehensive characterization of the occurrence and accumulation of AHSs in the ecosystem. In this study, we use a non-target screening (NTS) approach for this purpose. A major challenge in NTS of biological samples is the removal of matrix components such as lipids that may interfere with the detection and identification of compounds of interest. Here, we combine gel permeation chromatography with Florisil® column fractionation to achieve sufficient lipid removal for gas chromatography–high-resolution mass spectrometry analysis using electron ionization (EI) and electron capture negative ion chemical ionization (ECNI). In addition, we present new data processing workflows designed to systematically find and identify frequently occurring and biomagnifying AHSs, including known, emerging, and new contaminants. Using these workflows, we discovered a wide range of contaminants in tissue samples from blue mussels, fish, and marine mammals, and calculated their biomagnification factors (BMFs). Compounds with BMFs above 1 for herring and at least one marine mammal included legacy chlorinated pollutants (polychlorinated biphenyls, DDTs, chloro-benzenes/cyclohexanes, chlordanes, toxaphenes, dieldrin), polybrominated diphenyl ethers (PBDEs), and brominated biphenyls. However, there were also several halogenated natural products (halogenated methoxylated brominated diphenyl ethers, 1′-methyl-1,2′-bipyrroles, 1,1′-dimethyl-2,2′-bipyrroles, and the halogenated monoterpene mixed halogenated compound 1) as well as the novel flame retardant Dechlorane 602 and several polycyclic aromatic hydrocarbons, terpenoids, and steroids. The legacy pollutants exhibited the expected biomagnification behavior, demonstrating the utility of the unguided data processing workflow.