Emad Hosseinpour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emad Hosseinpour has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed W. Al Zand
Department of Civil Engineering, Universiti Kebangsaan Malaysia, Bangi, Malaysia
3 shared publications - Abel Teixeira1 shared publication
- Ali Joharchi
Department of Civil Engineering, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia
1 shared publication - Alireza Rashiddel
Department of Civil Engineering, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
1 shared publication Anton Mezhyrych
1 shared publication- Azrul A. Mutalib
Department of Civil Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
1 shared publication
Latest Publications
- Open Access
- 24 March 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (4) , 73
Development of a Stress Block Model to Predict the Ultimate Bending Capacity of Rectangular Concrete-Filled Steel Tube Beams Strengthened with U-Shaped CFRP Sheets
The prediction of the ultimate bending capacity of the rectangular concrete-filled steel tube (RCFST) beams strengthened with U-shaped carbon fiber reinforced polymer (CFRP) sheets is limited to using the existing empirical models. Thus, this study aims to develop a new theoretical model based on a stress block model to predict the ultimate bending capacity (Mu) of the RCFST beams strengthened with a U-shaped CFRP-wrapping scheme. For this purpose, 28 finite element (FE) models of CFRP-strengthened RCFST beams had been analyzed for further investigation of the flexural behavior and longitudinal stresses distributed along with the beam’s components (steel tube, concrete core, and CFRP layers). The main parameters investigated are concrete compressive strength, steel yield strength, number of CFRP layers, and CFRP-wrapping-depth ratio. In addition, the Mu values obtained from the FE models of the current study and those from the existing experimental tests performed by others are used to verify the corresponding values that are theoretically predicted by the new model. The comparison showed that the proposed model is moderately conservative, as the predicted values of Mu are, on average, up to 10% lower than those obtained from experimental tests and FE analysis.
- 24 March 2025
- Published by MDPI AG in Infrastructures
- Vol. 10 (4) , 73
Open AccessDevelopment of a Stress Block Model to Predict the Ultimate Bending Capacity of Rectangular Concrete-Filled Steel Tube Beams Strengthened with U-Shaped CFRP Sheets
The prediction of the ultimate bending capacity of the rectangular concrete-filled steel tube (RCFST) beams strengthened with U-shaped carbon fiber reinforced polymer (CFRP) sheets is limited to using the existing empirical models. Thus, this study aims to develop a new theoretical model based on a stress block model to predict the ultimate bending capacity (Mu) of the RCFST beams strengthened with a U-shaped CFRP-wrapping scheme. For this purpose, 28 finite element (FE) models of CFRP-strengthened RCFST beams had been analyzed for further investigation of the flexural behavior and longitudinal stresses distributed along with the beam’s components (steel tube, concrete core, and CFRP layers). The main parameters investigated are concrete compressive strength, steel yield strength, number of CFRP layers, and CFRP-wrapping-depth ratio. In addition, the Mu values obtained from the FE models of the current study and those from the existing experimental tests performed by others are used to verify the corresponding values that are theoretically predicted by the new model. The comparison showed that the proposed model is moderately conservative, as the predicted values of Mu are, on average, up to 10% lower than those obtained from experimental tests and FE analysis.
- Open Access
- 2 August 2022
- Published by Wiley in Journal of Engineering
- Vol. 2022, 1-26
Innovation of Shear Connectors in Slim Floor Beam Construction
Composite slim floor systems are increasingly applied in the construction industry. Therefore, several experimental and numerical studies have been conducted to investigate the composite flooring systems and examine the various details that may affect the production of composite floors. This review paper summarises some important developments of composite slim floor beams, such as the type of steel beam cross section and shear connectors used, presenting essential results and important notes from various studies. The fundamental structural elements and the contribution of conducted studies towards improving the shear capacity of composite beams in enhancing the general structural behaviour were also described. Finally, the paper concludes with the potential of a deeper investigation of some issues that accompany the application of certain types of shear connects or steel shapes used to improve the composite slim floor system so that the improvement construction industry may make the most out of using composite construction techniques.
- 2 August 2022
- Published by Wiley in Journal of Engineering
- Vol. 2022, 1-26
Open AccessInnovation of Shear Connectors in Slim Floor Beam Construction
Composite slim floor systems are increasingly applied in the construction industry. Therefore, several experimental and numerical studies have been conducted to investigate the composite flooring systems and examine the various details that may affect the production of composite floors. This review paper summarises some important developments of composite slim floor beams, such as the type of steel beam cross section and shear connectors used, presenting essential results and important notes from various studies. The fundamental structural elements and the contribution of conducted studies towards improving the shear capacity of composite beams in enhancing the general structural behaviour were also described. Finally, the paper concludes with the potential of a deeper investigation of some issues that accompany the application of certain types of shear connects or steel shapes used to improve the composite slim floor system so that the improvement construction industry may make the most out of using composite construction techniques.
- Open Access
Flexural Strength of Internally Stiffened Tubular Steel Beam Filled with Recycled Concrete Materials
The flexural strength of Slender steel tube sections is known to achieve significant improvements upon being filled with concrete material; however, this section is more likely to fail due to buckling under compression stresses. This study investigates the flexural behavior of a Slender steel tube beam that was produced by connecting two pieces of C-sections and was filled with recycled-aggregate concrete materials (CFST beam). The C-section’s lips behaved as internal stiffeners for the CFST beam’s cross-section. A static flexural test was conducted on five large scale specimens, including one specimen that was tested without concrete material (hollow specimen). The ABAQUS software was also employed for the simulation and non-linear analysis of an additional 20 CFST models in order to further investigate the effects of varied parameters that were not tested experimentally. The numerical model was able to adequately verify the flexural behavior and failure mode of the corresponding tested specimen, with an overestimation of the flexural strength capacity of about 3.1%. Generally, the study confirmed the validity of using the tubular C-sections in the CFST beam concept, and their lips (internal stiffeners) led to significant improvements in the flexural strength, stiffness, and energy absorption index. Moreover, a new analytical method was developed to specifically predict the bending (flexural) strength capacity of the internally stiffened CFST beams with steel stiffeners, which was well-aligned with the results derived from the current investigation and with those obtained by others.
Open AccessFlexural Strength of Internally Stiffened Tubular Steel Beam Filled with Recycled Concrete Materials
The flexural strength of Slender steel tube sections is known to achieve significant improvements upon being filled with concrete material; however, this section is more likely to fail due to buckling under compression stresses. This study investigates the flexural behavior of a Slender steel tube beam that was produced by connecting two pieces of C-sections and was filled with recycled-aggregate concrete materials (CFST beam). The C-section’s lips behaved as internal stiffeners for the CFST beam’s cross-section. A static flexural test was conducted on five large scale specimens, including one specimen that was tested without concrete material (hollow specimen). The ABAQUS software was also employed for the simulation and non-linear analysis of an additional 20 CFST models in order to further investigate the effects of varied parameters that were not tested experimentally. The numerical model was able to adequately verify the flexural behavior and failure mode of the corresponding tested specimen, with an overestimation of the flexural strength capacity of about 3.1%. Generally, the study confirmed the validity of using the tubular C-sections in the CFST beam concept, and their lips (internal stiffeners) led to significant improvements in the flexural strength, stiffness, and energy absorption index. Moreover, a new analytical method was developed to specifically predict the bending (flexural) strength capacity of the internally stiffened CFST beams with steel stiffeners, which was well-aligned with the results derived from the current investigation and with those obtained by others.
- Open Access
- 1 June 2021
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 24 (3) , 728-735
A numerical investigation on the through rib stiffener beam to concrete-filled steel tube column connections subjected to cyclic loading
- 1 June 2021
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 24 (3) , 728-735
Open AccessA numerical investigation on the through rib stiffener beam to concrete-filled steel tube column connections subjected to cyclic loading
- Open Access
- 5 July 2018
- Published by Penerbit UTM Press in Malaysian Journal of Civil Engineering
- Vol. 27 (2)
PUSHOVER ANALYSIS OF REINFORCED CONCRETE BUILDING WITH VERTICAL SHEAR LINK STEEL BRACES
In recent decades, steel cross bracing has been used as a conventional method to retrofit concrete buildings. Most of the cases utilized concentric steel braces system. However, studies concerning the behavior of RC frames with eccentricity steel bracing are quite limited. In this research, three types of structures incorporating special moment frames, RC structure with invert V braces and RC structures with vertical link beams with different stories were modeled through SAP 2000 and analyzed by considering nonlinear static analysis (pushover). Results revealed that invert Y steel braces (vertical shear links) system is an alternative way to construct a ductile structure with great lateral stiffness. It was also found that the axial force in braces is controlled by the behavior of the vertical link beam.
- 5 July 2018
- Published by Penerbit UTM Press in Malaysian Journal of Civil Engineering
- Vol. 27 (2)
Open AccessPUSHOVER ANALYSIS OF REINFORCED CONCRETE BUILDING WITH VERTICAL SHEAR LINK STEEL BRACES
In recent decades, steel cross bracing has been used as a conventional method to retrofit concrete buildings. Most of the cases utilized concentric steel braces system. However, studies concerning the behavior of RC frames with eccentricity steel bracing are quite limited. In this research, three types of structures incorporating special moment frames, RC structure with invert V braces and RC structures with vertical link beams with different stories were modeled through SAP 2000 and analyzed by considering nonlinear static analysis (pushover). Results revealed that invert Y steel braces (vertical shear links) system is an alternative way to construct a ductile structure with great lateral stiffness. It was also found that the axial force in braces is controlled by the behavior of the vertical link beam.
- 14 November 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 593-600
An Overview of Component Condition Assessment Systems (CCAS)
Recent requirements in component management of building systems have focused on the need for improving methods and metric tools to support component condition assessment and appropriate decisions for infrastructure owned facilities. A range of research articles (1975-2009) covering infrastructure system of component condition assessment systems (CCAS) is discussed to provide a practical and theoretical overview of CCAS infrastructure systems in industry and research. This paper reviews much of the literature on CCAS infrastructure systems. The literature is collected from major books, journals, technical reports and conference proceedings, the period covered is from 1975 to 2009. This paper finds that the focus of CCAS, surveyed in several aspects during the 35 years that have been investigated, from technology to measurement and from assessment function to component maintenance as an integrated part of the infrastructure component management. The purpose of this paper is to provide an overview of CCAS infrastructure system in industry and research. This paper offers help to researchers in understanding the selection of suitable method for component condition assessment in infrastructure systems.
- 14 November 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 593-600
An Overview of Component Condition Assessment Systems (CCAS)
Recent requirements in component management of building systems have focused on the need for improving methods and metric tools to support component condition assessment and appropriate decisions for infrastructure owned facilities. A range of research articles (1975-2009) covering infrastructure system of component condition assessment systems (CCAS) is discussed to provide a practical and theoretical overview of CCAS infrastructure systems in industry and research. This paper reviews much of the literature on CCAS infrastructure systems. The literature is collected from major books, journals, technical reports and conference proceedings, the period covered is from 1975 to 2009. This paper finds that the focus of CCAS, surveyed in several aspects during the 35 years that have been investigated, from technology to measurement and from assessment function to component maintenance as an integrated part of the infrastructure component management. The purpose of this paper is to provide an overview of CCAS infrastructure system in industry and research. This paper offers help to researchers in understanding the selection of suitable method for component condition assessment in infrastructure systems.