Evgenia A. Senokosova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Evgenia A. Senokosova has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Larisa V. Antonova
Research Institute for Complex Issues of Cardiovascular Diseases
4 shared publications - Dmitrii Vladimirovich Vasilchenko
Siberian State Medical University
2 shared publications - Elena A. Velikanova
Research Institute for Complex Issues of Cardiovascular Diseases
2 shared publications - Evgeniy N. Bolbasov
National Research Tomsk Polytechnic University
2 shared publications - Georgiy T. Dambaev
Department of Hospital Surgery with the Course of Cardiovascular Surgery, Siberian State Medical University, 634050 Tomsk, Russia
2 shared publications - Ilya M. Kolesnik
Laboratory of Hybrid Plasma Systems, Tomsk Polytechnic University, Tomsk 634050, Russia
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (10) , 2383
Biodegradable Vascular Patches for Arterial Reconstruction: In Vitro Study and Long-Term Implantation in a Sheep Model
Background/Objectives: The development of biodegradable materials for cardiovascular surgery that promote gradual replacement with native tissue is a key scientific challenge. Silk fibroin (SF) is a naturally derived biodegradable material with low immunogenicity and good biocompatibility. This study compared the in vitro and in vivo properties of SF patches with bovine pericardium (BP). Methods: SF and BP patches were characterized for ultrastructure, physico-mechanical properties, hydrolytic degradation, protein adsorption, hemocompatibility, and in vitro biocompatibility. SF and BP patches were implanted into sheep carotid arteries for 2, 6, and 12 months, with intravital ultrasound and optical coherence tomography (OCT) monitoring, followed by morphological examination. Results: The SF patch exhibited a porous-fibrous structure, uniaxial tensile properties similar to those of native arteries, and resistance to in vitro hydrolytic degradation for 12 months. It caused no hemolysis, minimal platelet aggregation, and in vitro biocompatibility comparable to BP. At 2 months of implantation, both types of patches showed no stenosis, aneurysms, or calcification, with endothelial-like cell coverage. At 6 months, SF patches displayed minimal degradation, no calcification, and no neointimal hyperplasia (NH), whereas BP patches showed delamination and NH. At 12 months, NH was observed in both groups; the degrading SF patch was partially replaced by host tissue, maintaining a three-component tissue organization comprising neointima, residual patch material, and neoadventitia, whereas the BP patches exhibited focal calcification. Conclusions: The SF patch showed promising in vitro and in vivo performance, artery-like tensile properties, and partial hemocompatibility. However, elastin absence and 12-month NH warrant further optimization of the material.
- 19 October 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (10) , 2383
Open AccessBiodegradable Vascular Patches for Arterial Reconstruction: In Vitro Study and Long-Term Implantation in a Sheep Model
Background/Objectives: The development of biodegradable materials for cardiovascular surgery that promote gradual replacement with native tissue is a key scientific challenge. Silk fibroin (SF) is a naturally derived biodegradable material with low immunogenicity and good biocompatibility. This study compared the in vitro and in vivo properties of SF patches with bovine pericardium (BP). Methods: SF and BP patches were characterized for ultrastructure, physico-mechanical properties, hydrolytic degradation, protein adsorption, hemocompatibility, and in vitro biocompatibility. SF and BP patches were implanted into sheep carotid arteries for 2, 6, and 12 months, with intravital ultrasound and optical coherence tomography (OCT) monitoring, followed by morphological examination. Results: The SF patch exhibited a porous-fibrous structure, uniaxial tensile properties similar to those of native arteries, and resistance to in vitro hydrolytic degradation for 12 months. It caused no hemolysis, minimal platelet aggregation, and in vitro biocompatibility comparable to BP. At 2 months of implantation, both types of patches showed no stenosis, aneurysms, or calcification, with endothelial-like cell coverage. At 6 months, SF patches displayed minimal degradation, no calcification, and no neointimal hyperplasia (NH), whereas BP patches showed delamination and NH. At 12 months, NH was observed in both groups; the degrading SF patch was partially replaced by host tissue, maintaining a three-component tissue organization comprising neointima, residual patch material, and neoadventitia, whereas the BP patches exhibited focal calcification. Conclusions: The SF patch showed promising in vitro and in vivo performance, artery-like tensile properties, and partial hemocompatibility. However, elastin absence and 12-month NH warrant further optimization of the material.
- Open Access
- 28 March 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (4) , 789
Advantages of Fibrin Polymerization Method without the Use of Exogenous Thrombin for Vascular Tissue Engineering Applications
Fibrin is widely used in vascular tissue engineering. Typically, fibrin polymerization is initiated by adding exogenous thrombin. In this study, we proposed a protocol for the preparation of completely autologous fibrin without the use of endogenous thrombin and compared the properties of the prepared fibrin matrix with that obtained by the traditional method. Fibrinogen was obtained by ethanol precipitation followed by fibrin polymerization by adding either exogenous thrombin and calcium chloride (ExThr), or only calcium chloride (EnThr). We examined the structure, mechanical properties, thrombogenicity, degradation rate and cytocompatibility of fibrin matrices. Factor XIII (FXIII) quantitative assay was performed by ELISA, and FXIII activity was assessed by SDS-PAGE detection of γ-γ cross-links. The results show that network structure of EnThr fibrin was characterized by thinner fibers. The EnThr fibrin matrices had higher strength, stiffness and resistance to proteolytic degradation compared to ExThr fibrin. EnThr fibrin matrices exhibited less thrombogenicity in vitro than ExThr, and retained high cytocompatibility. Thus, the proposed approach has several advantages over the traditional method, namely the fabrication of a completely autologous coating material that has better mechanical properties, higher resistance to proteolysis and lower thrombogenicity.
- 28 March 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (4) , 789
Open AccessAdvantages of Fibrin Polymerization Method without the Use of Exogenous Thrombin for Vascular Tissue Engineering Applications
Fibrin is widely used in vascular tissue engineering. Typically, fibrin polymerization is initiated by adding exogenous thrombin. In this study, we proposed a protocol for the preparation of completely autologous fibrin without the use of endogenous thrombin and compared the properties of the prepared fibrin matrix with that obtained by the traditional method. Fibrinogen was obtained by ethanol precipitation followed by fibrin polymerization by adding either exogenous thrombin and calcium chloride (ExThr), or only calcium chloride (EnThr). We examined the structure, mechanical properties, thrombogenicity, degradation rate and cytocompatibility of fibrin matrices. Factor XIII (FXIII) quantitative assay was performed by ELISA, and FXIII activity was assessed by SDS-PAGE detection of γ-γ cross-links. The results show that network structure of EnThr fibrin was characterized by thinner fibers. The EnThr fibrin matrices had higher strength, stiffness and resistance to proteolytic degradation compared to ExThr fibrin. EnThr fibrin matrices exhibited less thrombogenicity in vitro than ExThr, and retained high cytocompatibility. Thus, the proposed approach has several advantages over the traditional method, namely the fabrication of a completely autologous coating material that has better mechanical properties, higher resistance to proteolysis and lower thrombogenicity.
- Open Access
Composite Ferroelectric Membranes Based on Vinylidene Fluoride-Tetrafluoroethylene Copolymer and Polyvinylpyrrolidone for Wound Healing
Wound healing is a complex process and an ongoing challenge for modern medicine. Herein, we present the results of study of structure and properties of ferroelectric composite polymer membranes for wound healing. Membranes were fabricated by electrospinning from a solution of vinylidene fluoride/tetrafluoroethylene copolymer (VDF–TeFE) and polyvinylpyrrolidone (PVP) in dimethylformamide (DMF). The effects of the PVP content on the viscosity and conductivity of the spinning solution, DMF concentration, chemical composition, crystal structure, and conformation of VDF–TeFE macromolecules in the fabricated materials were studied. It was found that as PVP amount increased, the viscosity and conductivity of the spinning solutions decreased, resulting in thinner fibers. Using FTIR and XRD methods, it was shown that if the PVP content was lower than 50 wt %, the VDF–TeFE copolymer adopted a flat zigzag conformation (TTT conformation) and crystalline phases with ferroelectric properties were formed. Gas chromatography results indicated that an increase in the PVP concentration led to a higher residual amount of DMF in the material, causing cytotoxic effects on 3T3L1 fibroblasts. In vivo studies demonstrated that compared to classical gauze dressings impregnated with a solution of an antibacterial agent, ferroelectric composite membranes with 15 wt % PVP provided better conditions for the healing of purulent wounds.
Open AccessComposite Ferroelectric Membranes Based on Vinylidene Fluoride-Tetrafluoroethylene Copolymer and Polyvinylpyrrolidone for Wound Healing
Wound healing is a complex process and an ongoing challenge for modern medicine. Herein, we present the results of study of structure and properties of ferroelectric composite polymer membranes for wound healing. Membranes were fabricated by electrospinning from a solution of vinylidene fluoride/tetrafluoroethylene copolymer (VDF–TeFE) and polyvinylpyrrolidone (PVP) in dimethylformamide (DMF). The effects of the PVP content on the viscosity and conductivity of the spinning solution, DMF concentration, chemical composition, crystal structure, and conformation of VDF–TeFE macromolecules in the fabricated materials were studied. It was found that as PVP amount increased, the viscosity and conductivity of the spinning solutions decreased, resulting in thinner fibers. Using FTIR and XRD methods, it was shown that if the PVP content was lower than 50 wt %, the VDF–TeFE copolymer adopted a flat zigzag conformation (TTT conformation) and crystalline phases with ferroelectric properties were formed. Gas chromatography results indicated that an increase in the PVP concentration led to a higher residual amount of DMF in the material, causing cytotoxic effects on 3T3L1 fibroblasts. In vivo studies demonstrated that compared to classical gauze dressings impregnated with a solution of an antibacterial agent, ferroelectric composite membranes with 15 wt % PVP provided better conditions for the healing of purulent wounds.
- Open Access
- 5 November 2020
- Published by MDPI AG in Preprints.org
Composite Ferroelectric Membranes based on Vinylidene Fluoride-Tetrafluoroethylene Copolymer and Polyvinylpyrrolidone for Wound Healing: A Pilot Study
Herein, we report results of the study of the composite ferroelectric scaffolds based on vinylidene fluoride-tetrafluoroethylene copolymer (VDF-TeFE) and polyvinylpyrrolidone (PVP) produced by electrospinning and their application as a wound-healing material. The physicochemical properties of ferroelectric composite polymer scaffolds depending on the content of PVP (in the range from 0 to 50 wt %) including morphology, composition and crystalline structure were studied. The cytotoxicity of materials and the proliferative activity of cells during their cultivation on the surface of formed scaffolds are reported. It has been found that the optimal PVP content in the VDF-TeFE composite scaffolds is 15 wt%. On a model of a full-thickness contaminated wound in vivo, it was shown that piezoelectric scaffolds based on VDF-TeFE copolymer containing 15 wt% PVP provide better wound healing results in comparison with standard gauze dressings impregnated with a solution of an antibacterial agent.
- 5 November 2020
- Published by MDPI AG in Preprints.org
Open AccessComposite Ferroelectric Membranes based on Vinylidene Fluoride-Tetrafluoroethylene Copolymer and Polyvinylpyrrolidone for Wound Healing: A Pilot Study
Herein, we report results of the study of the composite ferroelectric scaffolds based on vinylidene fluoride-tetrafluoroethylene copolymer (VDF-TeFE) and polyvinylpyrrolidone (PVP) produced by electrospinning and their application as a wound-healing material. The physicochemical properties of ferroelectric composite polymer scaffolds depending on the content of PVP (in the range from 0 to 50 wt %) including morphology, composition and crystalline structure were studied. The cytotoxicity of materials and the proliferative activity of cells during their cultivation on the surface of formed scaffolds are reported. It has been found that the optimal PVP content in the VDF-TeFE composite scaffolds is 15 wt%. On a model of a full-thickness contaminated wound in vivo, it was shown that piezoelectric scaffolds based on VDF-TeFE copolymer containing 15 wt% PVP provide better wound healing results in comparison with standard gauze dressings impregnated with a solution of an antibacterial agent.