MWMondher Wali

Mondher Wali

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mondher Wali has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact Of Carbon Fiber on the surface properties of the 3D Printed PEGT Product

    by Abraheem Hadeeyah, Hana Jamhour, Ibrahim Emhemed, Fouzi Alhadar, Neila Masmoudi, Monder Wali

    هذه الدراسة تهدف لتطوير استخدام عملية الإنتاج والتشكيل لخيوط المواد البوليمرية المركبة الهجينة باستخدام الطابعة ثلاثية الأبعاد و حيث تم دراسة الخصائص السطحية (خشونة السطح، صلادة شور، والصلادة الدقيقة) لعينات مادة (PETG) ومقارنتها مع عينات من مادة (PETG/Carbon) المركبة وذلك باستخدام نسبة 15٪ من ألياف الكربون كحشو تقوية على شكل خيوط لمواد مركبة من ألياف الكربون مع البولي إيثيلين فثالات جلايكول (PETG/Carbon) باستخدام تقنية نمذجة الترسيب المنصهر (FDM)، جهزت العينات بحيث كانت درجة حرارة الطابعة 240◦م، ودرجة حرارة لوحة التصميم 80◦م، سرعة الطابعة 55 مم/ثانية، وسرعة المروحة 100مم/ ثانية، ارتفاع الطبقة 0.2مم . وبعد ذلك تم استخدام المجهر الضوئي وتقنيات FT-IR)) لفحص العينات. وأظهرت النتائج أن خشونة العينات المصنوعة من مادة (PETG/Carbon) المركبة تقل بنسبة 32.7٪عن العينات المصنوعة من مادة (PETG)فقط. ويعوذ ذلك لأن ألياف الكربون تعمل على كسر الروابط الثنائية في هيكل مادة ( PETG) وكذلك تحسين التدفق والالتصاق. وأن اختبار صلادة شور (Shoer D) لعينات (PETG) أقل بنسبة 2.16٪ من عينات PETG/Carbon)) المركبة، واختبار الصلادة (Micro-hardness ) كان أعلى قليلا HV10.4 مقارنة بـ HV9.6 ومع ذلك فان التعزيز بألياف الكربون أظهر توافقًا عاليًا مع بوليمرPETG في...


  • Three-dimensional coupling between orthodontic bone remodeling and superelastic behavior of a NiTi wire applied for initial alignment

    by Aroua Fathallah, Tarek Hassine, Fehmi Gamaoun, Mondher Wali

    Purpose NiTi wires are considered as the most appropriate wires to be used during the initial phase of orthodontic treatment. This work presents a numerical method to simulate the coupling between the orthodontic appliance and bone remodeling, which are the two mechanisms responsible for the orthodontic tooth movement. Methods The superelastic behavior of a NiTi wire was integrated in a three-dimensional simulation model to reproduce the long-term bone remodeling coupled with tooth alignment using the finite element method. The orthodontic load was derived by deforming the superelastic wire in order to adopt itself to the original position of irregular teeth. Root form was extracted from cone beam tomography imaging files. Results As a result, the teeth were aligned while the wire was recovering its initial shape. The canine was intruded by 0.53 mm, while the neighboring teeth were extruded by 0.44 and 0.46 mm. When the wire was loaded, it generated a load of 4.6 N on the bracket bonded on the canine. This force was active during the first day of the treatment. Then, the force continued to decline until the end of the correction period. The decreasing load delivered from the wire affected the teeth displacements as observed in real situations. Conclusion Despite the complexity of the presented numerical simulation, this procedure allowed the analysis of the orthodontic forces that were generated in the clinical experiments and of the biomechanical response of the periodontal support elements when using this kind of wire.