Jaeyeon Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jaeyeon Chung has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jinyoung Bae
Department of Anesthesiology and Pain medicine, Seoul National University Hospital, Seoul National University College of Medicine, #101 Daehak-ro, Jongno-GU, Seoul 03080, Korea
2 shared publications - Youn Joung Cho
Department of Anaesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
2 shared publications - Ho-Jin Lee
Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Korea
1 shared publication - Hye-Yeon Cho
Seoul Natl Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
1 shared publication - Hyun-Kyu Yoon
Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
1 shared publication - Ja Hyeon Ku
Department of Urology, National University Hospital, College of Medicine, Seoul National University, 101 Daehak-Ro, Jongno-Gu, Seoul 03080, Korea
1 shared publication
Latest Publications
- Open Access
- 12 April 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (8) , 1636
The Effect of Remote Ischemic Preconditioning on Serum Creatinine in Patients Undergoing Partial Nephrectomy: A Randomized Controlled Trial
Renal function declines after partial nephrectomy due to ischemic reperfusion injury induced by surgical insult or renal artery clamping. The effect of remote ischemic preconditioning (RIPC) on reducing renal injury after partial nephrectomy has not been studied regarding urinary biomarkers. Eighty-one patients undergoing partial nephrectomy were randomly assigned to either RIPC or the control group. RIPC protocol consisted of four cycles of five-min inflation and deflation of a blood pressure cuff to 250 mmHg. Serum creatinine levels were compared at the following time points: preoperative baseline, immediate postoperative, on the first and third days after surgery, and two weeks after surgery. The incidence of acute kidney injury, other surgical complication rates, and urinary biomarkers, including urine creatinine, β-2 microglobulin, microalbumin, and N-acetyl-beta-D-glucosaminidase were compared. Split renal functions measured by renal scan were compared up to 18 months after surgery. There was no significant difference in the serum creatinine level on the first postoperative day (median (interquartile range) 0.87 mg/dL (0.72–1.03) in the RIPC group vs. 0.92 mg/dL (0.71–1.12) in the control group, p = 0.728), nor at any other time point. There was no significant difference in the incidence of acute kidney injury. Secondary outcomes, including urinary biomarkers, were not significantly different between the groups. RIPC showed no significant effect on the postoperative serum creatinine level of the first postoperative day. We could not reveal any significant difference in the urinary biomarkers and clinical outcomes. However, further larger randomized trials are required, because our study was not sufficiently powered for the secondary outcomes.
- 12 April 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (8) , 1636
Open AccessThe Effect of Remote Ischemic Preconditioning on Serum Creatinine in Patients Undergoing Partial Nephrectomy: A Randomized Controlled Trial
Renal function declines after partial nephrectomy due to ischemic reperfusion injury induced by surgical insult or renal artery clamping. The effect of remote ischemic preconditioning (RIPC) on reducing renal injury after partial nephrectomy has not been studied regarding urinary biomarkers. Eighty-one patients undergoing partial nephrectomy were randomly assigned to either RIPC or the control group. RIPC protocol consisted of four cycles of five-min inflation and deflation of a blood pressure cuff to 250 mmHg. Serum creatinine levels were compared at the following time points: preoperative baseline, immediate postoperative, on the first and third days after surgery, and two weeks after surgery. The incidence of acute kidney injury, other surgical complication rates, and urinary biomarkers, including urine creatinine, β-2 microglobulin, microalbumin, and N-acetyl-beta-D-glucosaminidase were compared. Split renal functions measured by renal scan were compared up to 18 months after surgery. There was no significant difference in the serum creatinine level on the first postoperative day (median (interquartile range) 0.87 mg/dL (0.72–1.03) in the RIPC group vs. 0.92 mg/dL (0.71–1.12) in the control group, p = 0.728), nor at any other time point. There was no significant difference in the incidence of acute kidney injury. Secondary outcomes, including urinary biomarkers, were not significantly different between the groups. RIPC showed no significant effect on the postoperative serum creatinine level of the first postoperative day. We could not reveal any significant difference in the urinary biomarkers and clinical outcomes. However, further larger randomized trials are required, because our study was not sufficiently powered for the secondary outcomes.
- Open Access
- 10 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3615
Continuous Non-Invasive Arterial Pressure Monitoring (ClearSight System) and Ankle Blood Pressure Measurements as Alternatives to Conventional Arm Blood Pressure
Measuring blood pressure (BP) via a pneumatic cuff placed around the arm has long been the standard method. However, in clinical situations where BP monitoring at the arm is difficult, the ankle is frequently used instead. We compared continuous non-invasive blood pressure (CNBP) measurements obtained at the finger, ankle BP and arm BP in patients undergoing breast cancer surgery. Arm BP, ankle BP (both obtained with a conventional pneumatic cuff) and CNBP measurements were obtained every 2.5 min during surgery. Correlation and Bland–Altman analyses were performed and differences among measurements were analyzed using a linear mixed model. A total of 245 sets of BP measurements were obtained from 10 patients. All systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean blood pressure (MBP) measurements of ankle BP and CNBP were positively correlated with the arm BP measurements (Spearman rho 0.688–0.836, p < 0.001 for each correlation). The difference between CNBP and arm SBP was significantly smaller (least squares mean (95% confidence interval): −6.03 (−11.40, −0.67)) compared to that between ankle and arm SBP (least squares mean (95% CI): −15.32 (−20.69, −9.96), p = 0.019). However, this significant difference was not observed in DBP and MBP (−1.23 vs. 1.75, p = 0.190 and −3.85 vs. −2.63, p = 0.604, respectively). Ankle SBP measurements showed larger differences from arm SBP measurements than did CNBP SBP measurements in patients undergoing breast cancer surgery. CNBP could serve as a useful alternative to ankle BP when standard arm BP measurements cannot be obtained.
- 10 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3615
Open AccessContinuous Non-Invasive Arterial Pressure Monitoring (ClearSight System) and Ankle Blood Pressure Measurements as Alternatives to Conventional Arm Blood Pressure
Measuring blood pressure (BP) via a pneumatic cuff placed around the arm has long been the standard method. However, in clinical situations where BP monitoring at the arm is difficult, the ankle is frequently used instead. We compared continuous non-invasive blood pressure (CNBP) measurements obtained at the finger, ankle BP and arm BP in patients undergoing breast cancer surgery. Arm BP, ankle BP (both obtained with a conventional pneumatic cuff) and CNBP measurements were obtained every 2.5 min during surgery. Correlation and Bland–Altman analyses were performed and differences among measurements were analyzed using a linear mixed model. A total of 245 sets of BP measurements were obtained from 10 patients. All systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean blood pressure (MBP) measurements of ankle BP and CNBP were positively correlated with the arm BP measurements (Spearman rho 0.688–0.836, p < 0.001 for each correlation). The difference between CNBP and arm SBP was significantly smaller (least squares mean (95% confidence interval): −6.03 (−11.40, −0.67)) compared to that between ankle and arm SBP (least squares mean (95% CI): −15.32 (−20.69, −9.96), p = 0.019). However, this significant difference was not observed in DBP and MBP (−1.23 vs. 1.75, p = 0.190 and −3.85 vs. −2.63, p = 0.604, respectively). Ankle SBP measurements showed larger differences from arm SBP measurements than did CNBP SBP measurements in patients undergoing breast cancer surgery. CNBP could serve as a useful alternative to ankle BP when standard arm BP measurements cannot be obtained.