Hiroaki Matsumori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiroaki Matsumori has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Takashi Kosaka
Nagoya Institute of Technology, Nagoya, Japan
9 shared publications Nobuyuki Matsui
Nagoya Institute of Technology Gokiso-cho, Nagoya, Japan
5 shared publications- Subrata Saha
Aisin Corporation, Anjo, Japan
4 shared publications - Nobuyuki Matsui
Nagoya Institute of Technology, Nagoya, Japan
3 shared publications Yuto Maeda
Nagoya Institute of Technology, Nagoya, Japan
3 shared publicationsKiyotaka Koga
Aisin Corporation, Anjo, Japan
2 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Structural design of a common-mode inductor with metallic casing for improved high-frequency performance
The high-frequency common-mode (CM) attenuation of EMI filters for power converters in electric vehicles is often degraded by the equivalent parallel capacitance between the windings of the CM choke, which limits further miniaturization of the systems. This work presents a simple method to improve CM attenuation by exploiting a metallic casing combined with an injected dielectric material to generate a compensating capacitance around the CM choke. A distributed-parameter model was developed to determine the optimal casing configuration, and the proposed concept was validated through circuit simulations and experimental measurements. The results confirmed that the method effectively enhanced CM attenuation above 1 MHz. Because the metallic casing can utilize the existing converter housing, the proposed approach requires no additional components or cost and provides a practical, compact solution for power converter design.
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Open AccessStructural design of a common-mode inductor with metallic casing for improved high-frequency performance
The high-frequency common-mode (CM) attenuation of EMI filters for power converters in electric vehicles is often degraded by the equivalent parallel capacitance between the windings of the CM choke, which limits further miniaturization of the systems. This work presents a simple method to improve CM attenuation by exploiting a metallic casing combined with an injected dielectric material to generate a compensating capacitance around the CM choke. A distributed-parameter model was developed to determine the optimal casing configuration, and the proposed concept was validated through circuit simulations and experimental measurements. The results confirmed that the method effectively enhanced CM attenuation above 1 MHz. Because the metallic casing can utilize the existing converter housing, the proposed approach requires no additional components or cost and provides a practical, compact solution for power converter design.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 3094-3108
GaN Based Modified Integrated on-Board Charger Configuration Using Minimum Additional Active and Passive Components
In this paper, a GaN based modified non-isolated integrated on-board charger (IOBC) using a low value zero sequence inductance of traction motor and an inverter for class A and B segment electric vehicles (EV’s) with dual power conversion stages is proposed. In the modified configuration, the traction motor and the inverter will be used as components in the back-end DC to DC buck converter instead of in the front-end AC to DC boost converter as available in the conventional IOBC configuration. The modified IOBC configuration satisfies the permissible THD distortion limit of the Japanese utility companies and also keep the output peak-to-peak battery current ripple within the specified limits. Furthermore, electrical safety issues such as touch currents due to the presence of ground leakage currents caused by the low common-mode impedance of the non-isolated IOBC are solved by adding a split boost inductor and a floating EMI filter in the proposed modified IOBC configuration. The feasibility of the modified IOBC configuration and the solutions for the safety issues are verified from suitable simulation and experimental results.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 3094-3108
GaN Based Modified Integrated on-Board Charger Configuration Using Minimum Additional Active and Passive Components
In this paper, a GaN based modified non-isolated integrated on-board charger (IOBC) using a low value zero sequence inductance of traction motor and an inverter for class A and B segment electric vehicles (EV’s) with dual power conversion stages is proposed. In the modified configuration, the traction motor and the inverter will be used as components in the back-end DC to DC buck converter instead of in the front-end AC to DC boost converter as available in the conventional IOBC configuration. The modified IOBC configuration satisfies the permissible THD distortion limit of the Japanese utility companies and also keep the output peak-to-peak battery current ripple within the specified limits. Furthermore, electrical safety issues such as touch currents due to the presence of ground leakage currents caused by the low common-mode impedance of the non-isolated IOBC are solved by adding a split boost inductor and a floating EMI filter in the proposed modified IOBC configuration. The feasibility of the modified IOBC configuration and the solutions for the safety issues are verified from suitable simulation and experimental results.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 6886-6898
Comparative Study on Insulation Lifetime of Stator Winding of Dual Inverter Fed Open Winding IPMSM and Single Inverter Fed Star-Connected IPMSM for EV Application
In this paper, the turn-to-turn insulation lifetime of a dual inverter fed open winding interior permanent magnet synchronous motor (OWIPMSM) is compared with a conventional single inverter fed star-connected interior permanent magnet synchronous motor (SCIPMSM) for an EV traction application via an on-line experiment. A twisted pair coil (TP) is connected between the line-to-line terminal of windings of an OWIPMSM and a SCIPMSM without rotor and the effect of the line-to-line terminal surge voltage on the turn-to-turn insulation lifetime using the TP is investigated by generating PWM pulses at the inverter output identical to a variable load traction inverter drive. The turn-to-turn insulation life of the TP windings is approximately estimated by measuring the capacitance of the TP windings at regular time intervals during the on-line testing. Finally, experiment is carried out to detect the partial discharge in the TP windings and understand the physical relationship that exists between the total partial discharge count number and the decrease in capacitance of the TP windings after a specified time-period of insulation life testing. From the present preliminary insulation lifetime testing results using the TP, it is found that for motors with the same ratings, an OWIPMSM could be designed with a lower insulation level winding than the SCIPMSM for an EV traction application.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 6886-6898
Comparative Study on Insulation Lifetime of Stator Winding of Dual Inverter Fed Open Winding IPMSM and Single Inverter Fed Star-Connected IPMSM for EV Application
In this paper, the turn-to-turn insulation lifetime of a dual inverter fed open winding interior permanent magnet synchronous motor (OWIPMSM) is compared with a conventional single inverter fed star-connected interior permanent magnet synchronous motor (SCIPMSM) for an EV traction application via an on-line experiment. A twisted pair coil (TP) is connected between the line-to-line terminal of windings of an OWIPMSM and a SCIPMSM without rotor and the effect of the line-to-line terminal surge voltage on the turn-to-turn insulation lifetime using the TP is investigated by generating PWM pulses at the inverter output identical to a variable load traction inverter drive. The turn-to-turn insulation life of the TP windings is approximately estimated by measuring the capacitance of the TP windings at regular time intervals during the on-line testing. Finally, experiment is carried out to detect the partial discharge in the TP windings and understand the physical relationship that exists between the total partial discharge count number and the decrease in capacitance of the TP windings after a specified time-period of insulation life testing. From the present preliminary insulation lifetime testing results using the TP, it is found that for motors with the same ratings, an OWIPMSM could be designed with a lower insulation level winding than the SCIPMSM for an EV traction application.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 6684-6693
New Experimental System and Procedure for On-Line Insulation Life Testing of Stator Winding of Automotive Traction PMSM Without Using Dynamo System
This paper proposes an experimental procedure using a new experimental system for on-line insulation turn-to-turn life testing of a stator winding without a rotor of a permanent magnet synchronous motor. Without using any expensive large capacity dynamo set-up, the proposed system and procedure make it possible to test the insulation life of the stator winding under steady state operation of the motor even though at high temperatures of more than 200 ℃. The line-to-line surge voltage applied to the motor under the inverter's PWM control at the running state of the motor is successfully replicated by the proposed static system. Suitable control blocks are given to describe the experimental procedure for an automotive traction application. In the new experimental set-up, a twisted pair (TP) winding is connected between the U-V phase of the stator phase windings. The turn-to-turn insulation life of the TP windings is approximately estimated by measuring the capacitance of the TP windings at regular time intervals during the on-line testing. Finally, an experiment is carried out to detect the partial discharge in the TP windings and understand the physical relationship that exists between the total partial discharge count number and the decrease in capacitance of the TP windings after a specified time-period of insulation life testing.
- 22 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 6684-6693
New Experimental System and Procedure for On-Line Insulation Life Testing of Stator Winding of Automotive Traction PMSM Without Using Dynamo System
This paper proposes an experimental procedure using a new experimental system for on-line insulation turn-to-turn life testing of a stator winding without a rotor of a permanent magnet synchronous motor. Without using any expensive large capacity dynamo set-up, the proposed system and procedure make it possible to test the insulation life of the stator winding under steady state operation of the motor even though at high temperatures of more than 200 ℃. The line-to-line surge voltage applied to the motor under the inverter's PWM control at the running state of the motor is successfully replicated by the proposed static system. Suitable control blocks are given to describe the experimental procedure for an automotive traction application. In the new experimental set-up, a twisted pair (TP) winding is connected between the U-V phase of the stator phase windings. The turn-to-turn insulation life of the TP windings is approximately estimated by measuring the capacitance of the TP windings at regular time intervals during the on-line testing. Finally, an experiment is carried out to detect the partial discharge in the TP windings and understand the physical relationship that exists between the total partial discharge count number and the decrease in capacitance of the TP windings after a specified time-period of insulation life testing.
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Proper magnetic materials selection method for AC filter inductor design used in single phase PWM inverters
The use of wide-bandgap devices such as SiC and GaN has improved the efficiency and power density of power converters compared with conventional Si devices. However, a significant portion of the efficiency loss and volume in power converters is attributed to the magnetic components, particularly the challenges of miniaturization and loss reduction. This is due to the use of nonsinusoidal waveforms, with high-frequency switching of the PWM inverter introducing ripple components that exhibit complex loss characteristics. In this study, we propose a method for selecting magnetic materials for AC filter inductors based on loss and volume considerations. In addition, the effectiveness of the proposed method is validated through experiments.
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Open AccessProper magnetic materials selection method for AC filter inductor design used in single phase PWM inverters
The use of wide-bandgap devices such as SiC and GaN has improved the efficiency and power density of power converters compared with conventional Si devices. However, a significant portion of the efficiency loss and volume in power converters is attributed to the magnetic components, particularly the challenges of miniaturization and loss reduction. This is due to the use of nonsinusoidal waveforms, with high-frequency switching of the PWM inverter introducing ripple components that exhibit complex loss characteristics. In this study, we propose a method for selecting magnetic materials for AC filter inductors based on loss and volume considerations. In addition, the effectiveness of the proposed method is validated through experiments.
- 3 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5957-5970
Alternative PWM Switching Strategy Implementation for a Dual Inverter Fed Open Winding Motor Drive System for an Electric Vehicle Application
The dual inverter fed open winding interior permanent magnet synchronous motor (DIF-OW-IPMSM) is a promising traction drive system configuration for a high power and high efficiency electric vehicle. In this paper, for an electric vehicle application, an alternative PWM switching strategy of the DIF-OW-IPMSM is presented when the motor is operating in the medium and high speed regions. The alternative PWM switching strategy consists of operating one of the inverters in the low switching frequency synchronous 1 pulse (1P) mode and the other inverter in the high switching frequency asynchronous specialized continuous pulse width modulation (SCPWM) or discontinuous pulse width modulation (SDPWM). Preliminarily, the alternative PWM switching strategy has been verified from suitable simulation and experimental results with a dual Si-IGBT based inverter. Finally, a dual inverter configuration with a hybrid combination of Si-IGBT inverter and SiC-MOSFET inverter is recommended for a premium class electric vehicle to further improve the drive system efficiency. Suitable experimental results and relevant logical arguments are given for the dual inverter based on Si-IGBT and SiC-MOSFET to support the concept.
- 3 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5957-5970
Alternative PWM Switching Strategy Implementation for a Dual Inverter Fed Open Winding Motor Drive System for an Electric Vehicle Application
The dual inverter fed open winding interior permanent magnet synchronous motor (DIF-OW-IPMSM) is a promising traction drive system configuration for a high power and high efficiency electric vehicle. In this paper, for an electric vehicle application, an alternative PWM switching strategy of the DIF-OW-IPMSM is presented when the motor is operating in the medium and high speed regions. The alternative PWM switching strategy consists of operating one of the inverters in the low switching frequency synchronous 1 pulse (1P) mode and the other inverter in the high switching frequency asynchronous specialized continuous pulse width modulation (SCPWM) or discontinuous pulse width modulation (SDPWM). Preliminarily, the alternative PWM switching strategy has been verified from suitable simulation and experimental results with a dual Si-IGBT based inverter. Finally, a dual inverter configuration with a hybrid combination of Si-IGBT inverter and SiC-MOSFET inverter is recommended for a premium class electric vehicle to further improve the drive system efficiency. Suitable experimental results and relevant logical arguments are given for the dual inverter based on Si-IGBT and SiC-MOSFET to support the concept.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 3875-3888
Inverter Power Device Fault Detection and Fail Safe Action Strategy for Electric Vehicle With a Dual Inverter Fed Open Winding Motor
A electric vehicle (EV) needs high drive system efficiency, low motor noise and limp-home capability of the traction drive when there is a component failure. A dual inverter fed open winding interior permanent magnet synchronous motor (DIF-OW-IPMSM) drive system satisfied all the above needs. In this paper, new algorithms for the inverter power device fault detection and fail-safe action strategy for the DIF-OW-IPMSM drive system in the entire speed region of the EV are proposed to prove its high reliability. The new algorithms for the inverter power device fault detection are derived from the sensed three phase fault currents and their subsequent analytical and logical processing within the micro-computer. The fail-safe action strategy is derived such that the unbalanced three phase fault currents using the dual inverters are quickly restored to balanced three phase currents using a single inverter and hence, the effect of the vibration of the traction motor due to undesired torque ripple during inverter device fault condition is kept minimum. The proposed new algorithms are verified by suitable simulation and experimental results, and the safe limp-home capability of the DIF-OW-IPMSM drive system is demonstrated.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 3875-3888
Inverter Power Device Fault Detection and Fail Safe Action Strategy for Electric Vehicle With a Dual Inverter Fed Open Winding Motor
A electric vehicle (EV) needs high drive system efficiency, low motor noise and limp-home capability of the traction drive when there is a component failure. A dual inverter fed open winding interior permanent magnet synchronous motor (DIF-OW-IPMSM) drive system satisfied all the above needs. In this paper, new algorithms for the inverter power device fault detection and fail-safe action strategy for the DIF-OW-IPMSM drive system in the entire speed region of the EV are proposed to prove its high reliability. The new algorithms for the inverter power device fault detection are derived from the sensed three phase fault currents and their subsequent analytical and logical processing within the micro-computer. The fail-safe action strategy is derived such that the unbalanced three phase fault currents using the dual inverters are quickly restored to balanced three phase currents using a single inverter and hence, the effect of the vibration of the traction motor due to undesired torque ripple during inverter device fault condition is kept minimum. The proposed new algorithms are verified by suitable simulation and experimental results, and the safe limp-home capability of the DIF-OW-IPMSM drive system is demonstrated.
- Open Access
- 1 February 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (2) , 025302
Iron loss evaluation method for SiFe sheet material under PWM inverter excitation
This study proposed an iron loss evaluation method for SiFe sheet material under high-frequency current ripple caused by pulse width modulation (PWM) inverter switching. The PWM inverter switching results in dynamic minor loops on the BH plane, leading to iron loss. Furthermore, in magnetic material with wide major loops, such as SiFe sheet material, the iron loss caused by one dynamic minor loop differs based on the flux density bias difference even for the same magnetic field bias. A previous study reported an iron loss calculation error because the conventional iron loss calculation method neglected the iron loss of the flux density bias characteristic in the same magnetic field bias. Therefore, we modified the previously developed iron loss measurement system to collect the iron loss of the flux density bias characteristic and proposed an iron loss calculation method for SiFe sheet material.
- 1 February 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (2) , 025302
Open AccessIron loss evaluation method for SiFe sheet material under PWM inverter excitation
This study proposed an iron loss evaluation method for SiFe sheet material under high-frequency current ripple caused by pulse width modulation (PWM) inverter switching. The PWM inverter switching results in dynamic minor loops on the BH plane, leading to iron loss. Furthermore, in magnetic material with wide major loops, such as SiFe sheet material, the iron loss caused by one dynamic minor loop differs based on the flux density bias difference even for the same magnetic field bias. A previous study reported an iron loss calculation error because the conventional iron loss calculation method neglected the iron loss of the flux density bias characteristic in the same magnetic field bias. Therefore, we modified the previously developed iron loss measurement system to collect the iron loss of the flux density bias characteristic and proposed an iron loss calculation method for SiFe sheet material.
- 28 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 2069-2080
Dual Inverter-Fed Open Winding IPMSM Drive System for High-Power Premium Class EV
Recently, the development of a premium class of electric vehicles (EVs) with high-power (250 kW) motor drive systems and high energy/high voltage (100 kWh/800 V) batteries has been the prominent focus of various automotive makers. Considering the drive system efficiency, motor acoustic noise, system fail-safe features, and cost, the dual inverter with a dual battery and an open-winding interior permanent magnet motor is considered to be a highly promising drive system configuration for premium class EVs. Therefore, considering the high drive system efficiency and low motor acoustic noise, the authors propose selecting different pulse width modulation (PWM) switching pattern modes in the frequent vehicle operating area based on the vehicle driving modes for the system configuration of premium class EVs. The authors performed suitable simulations and experiments with a 65 kW motor drive system. The experimental results are validated to verify the effectiveness of selecting different PWM switching modes based on the vehicle driving pattern.
- 28 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 2069-2080
Dual Inverter-Fed Open Winding IPMSM Drive System for High-Power Premium Class EV
Recently, the development of a premium class of electric vehicles (EVs) with high-power (250 kW) motor drive systems and high energy/high voltage (100 kWh/800 V) batteries has been the prominent focus of various automotive makers. Considering the drive system efficiency, motor acoustic noise, system fail-safe features, and cost, the dual inverter with a dual battery and an open-winding interior permanent magnet motor is considered to be a highly promising drive system configuration for premium class EVs. Therefore, considering the high drive system efficiency and low motor acoustic noise, the authors propose selecting different pulse width modulation (PWM) switching pattern modes in the frequent vehicle operating area based on the vehicle driving modes for the system configuration of premium class EVs. The authors performed suitable simulations and experiments with a 65 kW motor drive system. The experimental results are validated to verify the effectiveness of selecting different PWM switching modes based on the vehicle driving pattern.
- Open Access
- 2 April 2021
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 12 (2) , 58
Comparative Study on Hybrid Excitation Flux Switching Motors without and with Variably Magnetizable Permanent Magnets for Electrified Vehicle Propulsion
A demand for high efficiency traction motors has been accelerated by the promotion of electrified vehicles, such as battery and fuel cell electric vehicles. As a part of development of the high efficiency traction motor, this paper reports a comparative study on two kinds of hybrid excitation flux switching motors (HEFSM) as a variable flux machine. One is the conventional HEFSM, which consists of a stator with constantly magnetized-permanent magnets, field excitation coils (FECs) and three-phase armature windings, and a rotor with salient poles like a switched reluctance motor. The other is a HEFSM employing variably magnetizable-permanent magnets (VM-PMs) that replace a part in the FEC slot area in the conventional one. Based on the variable magnetization nature of VM-PMs, the latter HEFSM promises that the replacement of magnetomotive force (mmf) of FECs with that of the VM-PMs makes the motor efficiency better at both low- and high-speed under the low-torque condition, that is, at both urban driving or highway cruising. To verify that, finite element analysis- (FEA)-based design simulations, as well as experimental performance evaluations for the two kinds of HEFSM, were conducted under reasonable dimensional and electrical constraints. As a result, it is shown that the latter HEFSM can achieve higher motor efficiency at the low-torque and high-speed region while keeping the motor efficiency at the low-torque and low-speed region.
- 2 April 2021
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 12 (2) , 58
Open AccessComparative Study on Hybrid Excitation Flux Switching Motors without and with Variably Magnetizable Permanent Magnets for Electrified Vehicle Propulsion
A demand for high efficiency traction motors has been accelerated by the promotion of electrified vehicles, such as battery and fuel cell electric vehicles. As a part of development of the high efficiency traction motor, this paper reports a comparative study on two kinds of hybrid excitation flux switching motors (HEFSM) as a variable flux machine. One is the conventional HEFSM, which consists of a stator with constantly magnetized-permanent magnets, field excitation coils (FECs) and three-phase armature windings, and a rotor with salient poles like a switched reluctance motor. The other is a HEFSM employing variably magnetizable-permanent magnets (VM-PMs) that replace a part in the FEC slot area in the conventional one. Based on the variable magnetization nature of VM-PMs, the latter HEFSM promises that the replacement of magnetomotive force (mmf) of FECs with that of the VM-PMs makes the motor efficiency better at both low- and high-speed under the low-torque condition, that is, at both urban driving or highway cruising. To verify that, finite element analysis- (FEA)-based design simulations, as well as experimental performance evaluations for the two kinds of HEFSM, were conducted under reasonable dimensional and electrical constraints. As a result, it is shown that the latter HEFSM can achieve higher motor efficiency at the low-torque and high-speed region while keeping the motor efficiency at the low-torque and low-speed region.