Tomoya Manaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomoya Manaka has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Hiroaki Nakamura
Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
6 shared publications- Ryosuke Iio
Roth McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, Canada
5 shared publications - Yoichi Ito
Osaka Shoulder Center, Ito Clinic, Matsubara, Japan
5 shared publications - Yoshihiro Hirakawa
Department of orthopedic surgery, Osaka Metropolitan University Graduate of Medicine, osaka, Japan
5 shared publications - Katsumasa Nakazawa
Department of Orthopaedic Surgery, Graduate School of Medicine, Osaka Metropolitan University, Osaka 545-8585, Japan
4 shared publications Hayato Shimizu
Shimizu Orthopaedic Clinic, Osaka, Japan
2 shared publications
Latest Publications
- 30 July 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-11
Effect of humeral lengthening on post-operative pain scores by three-dimensional measurements in patients undergoing reverse shoulder arthroplasty
Purpose Humeral lengthening (HL) has been reported to correlate with post-operative clinical outcomes of reverse shoulder arthroplasty (RSA). However, these are simple radiographic evaluations, and three-dimensional (3D) assessments using computed tomography (CT) images have not been considered. This study aimed to investigate the factors that influence post-operative clinical outcomes of RSA implant placement using a 3D evaluation system, specifically, the effect of HL on post-operative clinical outcomes. Methods This retrospective study included 49 patients who underwent RSA using the Exactech Equinoxe Reverse Shoulder System (Exactech Inc., Gainesville, FL, USA) for cuff tear arthropathy or irreparable rotator cuff tear between August 2017 and June 2021 and were followed up for at least two years post-operatively. An augmented baseplate was used in 19 patients. Pre- and post-operative CT images were used to evaluate post-operative implant placement using the 3D planning software ZedShoulder software (Lexi, Tokyo, Japan). Global offset, overhang of glenosphere, glenoid version, glenoid inclination, HL, and amount of humeral resection were measured. Clinical outcomes were also evaluated in relation to post-operative implant placement. Results Univariate analysis revealed that HL correlated with the pain score of Constant–Murley score and visual analog scale (VAS) (r=-0.37, p = 0.01; r = 0.38, p = 0.01). Moreover, the overhang of the glenosphere correlated with the Constant–Murley score and the pain score of the Constant–Murley score (r=-0.34, p = 0.02; r = 0.31, p = 0.03). Using multivariate analysis, HL and the overhang of the glenosphere were factors influencing the pain score on the Constant–Murley score (R2 = 0.502). Allocating patients with HL into two groups based on the amount of lengthening (≤ 18 mm and > 18 mm), the pain score of the Constant–Murley score and pain VAS were significantly lower in the group with HL of ≤ 18 mm (p < 0.01, p < 0.01). Conclusion HL affected post-operative pain scores in patients undergoing RSA. Particularly, the group with HL of ≤ 18 mm had a significantly lower pain score. Therefore, we suggest that post-operative pain scores could be improved by reducing the HL to ≤ 18 mm. However, this was a retrospective study with a small number of cases, and the correlation between HL and outcomes requires further investigation.
- 30 July 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-11
Effect of humeral lengthening on post-operative pain scores by three-dimensional measurements in patients undergoing reverse shoulder arthroplasty
Purpose Humeral lengthening (HL) has been reported to correlate with post-operative clinical outcomes of reverse shoulder arthroplasty (RSA). However, these are simple radiographic evaluations, and three-dimensional (3D) assessments using computed tomography (CT) images have not been considered. This study aimed to investigate the factors that influence post-operative clinical outcomes of RSA implant placement using a 3D evaluation system, specifically, the effect of HL on post-operative clinical outcomes. Methods This retrospective study included 49 patients who underwent RSA using the Exactech Equinoxe Reverse Shoulder System (Exactech Inc., Gainesville, FL, USA) for cuff tear arthropathy or irreparable rotator cuff tear between August 2017 and June 2021 and were followed up for at least two years post-operatively. An augmented baseplate was used in 19 patients. Pre- and post-operative CT images were used to evaluate post-operative implant placement using the 3D planning software ZedShoulder software (Lexi, Tokyo, Japan). Global offset, overhang of glenosphere, glenoid version, glenoid inclination, HL, and amount of humeral resection were measured. Clinical outcomes were also evaluated in relation to post-operative implant placement. Results Univariate analysis revealed that HL correlated with the pain score of Constant–Murley score and visual analog scale (VAS) (r=-0.37, p = 0.01; r = 0.38, p = 0.01). Moreover, the overhang of the glenosphere correlated with the Constant–Murley score and the pain score of the Constant–Murley score (r=-0.34, p = 0.02; r = 0.31, p = 0.03). Using multivariate analysis, HL and the overhang of the glenosphere were factors influencing the pain score on the Constant–Murley score (R2 = 0.502). Allocating patients with HL into two groups based on the amount of lengthening (≤ 18 mm and > 18 mm), the pain score of the Constant–Murley score and pain VAS were significantly lower in the group with HL of ≤ 18 mm (p < 0.01, p < 0.01). Conclusion HL affected post-operative pain scores in patients undergoing RSA. Particularly, the group with HL of ≤ 18 mm had a significantly lower pain score. Therefore, we suggest that post-operative pain scores could be improved by reducing the HL to ≤ 18 mm. However, this was a retrospective study with a small number of cases, and the correlation between HL and outcomes requires further investigation.
- Open Access
- 8 November 2024
- Published by Elsevier in JSES International
- Vol. 9 (2) , 436-444
Three-dimensional evaluation of stem placement accuracy with the conventional guide in reverse shoulder arthroplasty and its relevance to clinical outcomes
- 8 November 2024
- Published by Elsevier in JSES International
- Vol. 9 (2) , 436-444
Open AccessThree-dimensional evaluation of stem placement accuracy with the conventional guide in reverse shoulder arthroplasty and its relevance to clinical outcomes
- Open Access
- 30 September 2024
- Published by Elsevier in JSES International
- Vol. 9 (1) , 206-211
Accuracy of placement of the glenoid component in reverse shoulder arthroplasty using a custom baseplate for severe glenoid deficiency
- 30 September 2024
- Published by Elsevier in JSES International
- Vol. 9 (1) , 206-211
Open AccessAccuracy of placement of the glenoid component in reverse shoulder arthroplasty using a custom baseplate for severe glenoid deficiency
- Open Access
- 22 September 2023
- Published by Elsevier in JSES International
- Vol. 8 (1) , 119-125
Bone mineral density around cementless short stems after reverse shoulder arthroplasty: changes over time and its relationship to stem positioning
- 22 September 2023
- Published by Elsevier in JSES International
- Vol. 8 (1) , 119-125
Open AccessBone mineral density around cementless short stems after reverse shoulder arthroplasty: changes over time and its relationship to stem positioning
- 18 August 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (1) , 181-191
Impact of constrained humeral liner on impingement-free range of motion and impingement type in reverse shoulder arthroplasty using a computer simulation
- 18 August 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (1) , 181-191
Impact of constrained humeral liner on impingement-free range of motion and impingement type in reverse shoulder arthroplasty using a computer simulation
- Open Access
- 14 June 2021
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 3 (4) , e981-e988
Comparison of Occurrence of Bone Tunnel Laceration, Clinical Results, and Cuff Repair Integrity of Transosseous Arthroscopic Rotator Cuff Repair With and Without Lateral Cortical Augmentation
Purpose: To compare the occurrence of bone tunnel laceration, the short‐term clinical results, and cuff repair integrity of transosseous arthroscopic rotator cuff repair (ARCR) using a tunneling device, with and without lateral cortical augmentation. Methods: A retrospective review of patients who underwent transosseous ARCR from May 2012 to December 2017 was conducted. The inclusion criterion was repairable medium‐ to massive‐sized full‐thickness rotator cuff tear. This study included 2 consecutive series of patients undergoing transosseous ARCR with and without lateral cortical augmentation, called the ITO method and AT method, respectively. The incidence of bone tunnel laceration was evaluated intraoperatively. Patients were assessed through a range of motion and Constant scores preoperatively and at final follow‐up. Further, magnetic resonance imaging was performed at 24 months postoperatively to examine the repaired rotator cuff integrity. Results: A total of 121 subjects were included: 33 in the AT group and 88 in the ITO group. The intraoperative bone tunnel laceration occurrence rate was 67% and 4% for the AT and ITO methods, respectively; the difference was significant ( P = .001). Anatomic failure rate (Sugaya Ⅲ, Ⅳ, and Ⅴ) rate for medium‐ to large‐sized tears was significantly lower for the ITO than for the AT method (29% vs 65%, P = .004), but not for massive tears (61% vs 69%, P = .515). The mean forward elevation, abduction, external rotation, internal rotation, and Constant score were significantly improved at final follow‐up from preoperative values. There were no significant differences between the 2 methods. Conclusions: Transosseous ARCR using a tunneling device with and without lateral cortical augmentation is a reliable method of improving clinical results at a minimum follow‐up of 2 years. The intraoperative occurrence rate of bone tunnel laceration occurrence rate and the anatomic failure rate of medium‐ to large‐sized cuff tear were lower with lateral cortical augmentation than without it. Level of Evidence: Level Ⅳ, therapeutic cases series.
- 14 June 2021
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 3 (4) , e981-e988
Open AccessComparison of Occurrence of Bone Tunnel Laceration, Clinical Results, and Cuff Repair Integrity of Transosseous Arthroscopic Rotator Cuff Repair With and Without Lateral Cortical Augmentation
Purpose: To compare the occurrence of bone tunnel laceration, the short‐term clinical results, and cuff repair integrity of transosseous arthroscopic rotator cuff repair (ARCR) using a tunneling device, with and without lateral cortical augmentation. Methods: A retrospective review of patients who underwent transosseous ARCR from May 2012 to December 2017 was conducted. The inclusion criterion was repairable medium‐ to massive‐sized full‐thickness rotator cuff tear. This study included 2 consecutive series of patients undergoing transosseous ARCR with and without lateral cortical augmentation, called the ITO method and AT method, respectively. The incidence of bone tunnel laceration was evaluated intraoperatively. Patients were assessed through a range of motion and Constant scores preoperatively and at final follow‐up. Further, magnetic resonance imaging was performed at 24 months postoperatively to examine the repaired rotator cuff integrity. Results: A total of 121 subjects were included: 33 in the AT group and 88 in the ITO group. The intraoperative bone tunnel laceration occurrence rate was 67% and 4% for the AT and ITO methods, respectively; the difference was significant ( P = .001). Anatomic failure rate (Sugaya Ⅲ, Ⅳ, and Ⅴ) rate for medium‐ to large‐sized tears was significantly lower for the ITO than for the AT method (29% vs 65%, P = .004), but not for massive tears (61% vs 69%, P = .515). The mean forward elevation, abduction, external rotation, internal rotation, and Constant score were significantly improved at final follow‐up from preoperative values. There were no significant differences between the 2 methods. Conclusions: Transosseous ARCR using a tunneling device with and without lateral cortical augmentation is a reliable method of improving clinical results at a minimum follow‐up of 2 years. The intraoperative occurrence rate of bone tunnel laceration occurrence rate and the anatomic failure rate of medium‐ to large‐sized cuff tear were lower with lateral cortical augmentation than without it. Level of Evidence: Level Ⅳ, therapeutic cases series.
- 1 July 2019
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 30 (4) , 336-342
Intraoperative bone tunnel laceration affects integrity of arthroscopic transosseous rotator cuff repair with a tunneling device
Background: We aimed to evaluate the functional outcomes, incidence of bone tunnel laceration, and bone tunnel morphology of transosseous arthroscopic rotator cuff repair (ARCR) with the Arthro-Tunneler(TM). Methods: Between May 2012 and April 2013, patients with full-thickness tears who underwent transosseous ARCR with the Arthro-Tunnele(TM) and could be followed for a minimum of 2 yr were included in this retrospective study. Functional outcomes, cuff repair integrity, intraoperative bone tunnel laceration, and postoperative bone tunnel morphology were analyzed. Results: We retrospectively evaluated 42 consecutive patients (average age: 67.6 yr) who underwent transosseous ARCR. The mean active forward elevation, mean active abduction, mean Constant-Murley score, mean American Shoulder and Elbow Surgeon Score (ASES), and pain Visual Analogue Scale (VAS) improved from preoperative values of 127 degrees, 118 degrees, 50.3 points, 53.2 points, and 4.5 to 159 degrees, 160 degrees, 83.3 points, 78.5 points, and 1.7, respectively, at the final follow-up (P<0.001, P<0.01, P<0.001, P<0.001, P<0.001, respectively). The re-tear rate was 16.7%. The intraoperative bone tunnel laceration occurrence was 67.8% (61 tunnels). Bone tunnel laceration and re-tear were significantly correlated. We evaluated the morphology of 81 bone tunnels with MRI of 90 bone tunnels. Eight, 37, and 36 tunnels were L-shaped, curve-shaped, and straight-shaped, respectively. Conclusions: The clinical results of transosseous ARCR with the Arthro-Tunneler(TM) were significantly improved at a minimum of 2 yr of follow-up. However, patients older than 65 yr were at a high risk of developing bone tunnel laceration, which was associated with rotator cuff re-tear.
- 1 July 2019
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 30 (4) , 336-342
Intraoperative bone tunnel laceration affects integrity of arthroscopic transosseous rotator cuff repair with a tunneling device
Background: We aimed to evaluate the functional outcomes, incidence of bone tunnel laceration, and bone tunnel morphology of transosseous arthroscopic rotator cuff repair (ARCR) with the Arthro-Tunneler(TM). Methods: Between May 2012 and April 2013, patients with full-thickness tears who underwent transosseous ARCR with the Arthro-Tunnele(TM) and could be followed for a minimum of 2 yr were included in this retrospective study. Functional outcomes, cuff repair integrity, intraoperative bone tunnel laceration, and postoperative bone tunnel morphology were analyzed. Results: We retrospectively evaluated 42 consecutive patients (average age: 67.6 yr) who underwent transosseous ARCR. The mean active forward elevation, mean active abduction, mean Constant-Murley score, mean American Shoulder and Elbow Surgeon Score (ASES), and pain Visual Analogue Scale (VAS) improved from preoperative values of 127 degrees, 118 degrees, 50.3 points, 53.2 points, and 4.5 to 159 degrees, 160 degrees, 83.3 points, 78.5 points, and 1.7, respectively, at the final follow-up (P<0.001, P<0.01, P<0.001, P<0.001, P<0.001, respectively). The re-tear rate was 16.7%. The intraoperative bone tunnel laceration occurrence was 67.8% (61 tunnels). Bone tunnel laceration and re-tear were significantly correlated. We evaluated the morphology of 81 bone tunnels with MRI of 90 bone tunnels. Eight, 37, and 36 tunnels were L-shaped, curve-shaped, and straight-shaped, respectively. Conclusions: The clinical results of transosseous ARCR with the Arthro-Tunneler(TM) were significantly improved at a minimum of 2 yr of follow-up. However, patients older than 65 yr were at a high risk of developing bone tunnel laceration, which was associated with rotator cuff re-tear.