Kari Maki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kari Maki has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Kim Forssén
VTT Technical Research Centre of Finland Ltd., 02044 Espoo, Finland
2 shared publications - Anna Kulmala
VTT Technical Research Centre of Finland, Espoo, Finland
1 shared publication - Carlo Sandroni
Ricerca sul Sistema Energetico, Milano, Italy
1 shared publication - Davood Babazadeh
Hamburg University of Technology
1 shared publication E. C. W. de Jong
KEMA B.V., Arnhem, Netherlands
1 shared publicationF. Coffele
University of Strathclyde, Glasgow, UK
1 shared publication
Latest Publications
- 9 November 2020
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 137 (8) , 502-508
Achievements, experiences, and lessons learned from the European research infrastructure ERIGrid related to the validation of power and energy systems
- 9 November 2020
- Published by Springer Nature in e+i Elektrotechnik und Informationstechnik
- Vol. 137 (8) , 502-508
Achievements, experiences, and lessons learned from the European research infrastructure ERIGrid related to the validation of power and energy systems
- 1 December 2016
- Published by World Scientific Pub Co Pte Ltd in Journal of Extreme Events
- Vol. 03 (04) , 1650016
Enhancing the Resilience of Electricity Networks by Multi-stakeholder Risk Assessment: The Case Study of Adverse Winter Weather in Finland
Electricity networks in Finland are subject to adverse winter weather, particularly a combination of heavy snowfall with strong winds, causing electricity outages especially in the rural areas. The severe consequences of such events require that electricity distributors and the entire network of stakeholders establish a proactive risk management for achieving enhanced situational awareness during adverse weather events, efficient and effective recovering after electricity outage as well as improved preparedness against future events. This paper shows how a risk assessment performed with an Action Error Analysis (AEA) were conducted in order to enhance the resilience of electricity networks against adverse winter weather. This also encompassed an assessment of co-operation and communication structures about such risks. Adverse winter weather that took place in Pirkanmaa, in South-West Finland in November 2015, serves as a case study and laboratory for the assessments. The results of the AEA underscore the importance of co-operation and communication-related challenges that electricity distributors, rescue authorities and municipalities face in maintaining and obtaining a high level of resilience of electricity networks during and after heavy snowfalls. Against this background, novel ways and measures related to co-operation and communication of stakeholders to improve the resilience of electricity networks against future events are discussed.
- 1 December 2016
- Published by World Scientific Pub Co Pte Ltd in Journal of Extreme Events
- Vol. 03 (04) , 1650016
Enhancing the Resilience of Electricity Networks by Multi-stakeholder Risk Assessment: The Case Study of Adverse Winter Weather in Finland
Electricity networks in Finland are subject to adverse winter weather, particularly a combination of heavy snowfall with strong winds, causing electricity outages especially in the rural areas. The severe consequences of such events require that electricity distributors and the entire network of stakeholders establish a proactive risk management for achieving enhanced situational awareness during adverse weather events, efficient and effective recovering after electricity outage as well as improved preparedness against future events. This paper shows how a risk assessment performed with an Action Error Analysis (AEA) were conducted in order to enhance the resilience of electricity networks against adverse winter weather. This also encompassed an assessment of co-operation and communication structures about such risks. Adverse winter weather that took place in Pirkanmaa, in South-West Finland in November 2015, serves as a case study and laboratory for the assessments. The results of the AEA underscore the importance of co-operation and communication-related challenges that electricity distributors, rescue authorities and municipalities face in maintaining and obtaining a high level of resilience of electricity networks during and after heavy snowfalls. Against this background, novel ways and measures related to co-operation and communication of stakeholders to improve the resilience of electricity networks against future events are discussed.
- Open Access
- 1 January 2016
- Published by Institution of Engineering and Technology (IET)
- p. 105 (4 .)
Resilience of Finnish electricity distribution networks against extreme weather conditions
Extreme weather conditions threaten Finnish electricity distribution networks that are mostly built as overhead lines. This paper presents selected methods and technologies that can be taken to improve the networks' resilience during different phases of a disruptive event.
- 1 January 2016
- Published by Institution of Engineering and Technology (IET)
- p. 105 (4 .)
Open AccessResilience of Finnish electricity distribution networks against extreme weather conditions
Extreme weather conditions threaten Finnish electricity distribution networks that are mostly built as overhead lines. This paper presents selected methods and technologies that can be taken to improve the networks' resilience during different phases of a disruptive event.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 455-460
Active Voltage Level Management of Distribution Networks with Distributed Generation using On Load Tap Changing Transformers
In this paper, time domain performance of active voltage level management based on co-ordinated control of substation voltage is studied. A control algorithm that controls the set point of the automatic voltage control (AVC) relay at the substation is proposed and its operation in an example network is tested using PSCAD simulations. The study network is a real distribution network located in south-west Finland which will experience voltage rise problems if a planned wind park is constructed.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 455-460
Active Voltage Level Management of Distribution Networks with Distributed Generation using On Load Tap Changing Transformers
In this paper, time domain performance of active voltage level management based on co-ordinated control of substation voltage is studied. A control algorithm that controls the set point of the automatic voltage control (AVC) relay at the substation is proposed and its operation in an example network is tested using PSCAD simulations. The study network is a real distribution network located in south-west Finland which will experience voltage rise problems if a planned wind park is constructed.