Kumarasamy Jayakumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kumarasamy Jayakumar has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Huangxian Ju
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
2 shared publications - Maria Belén Camarada
Cluster of Excellence livMatS @ FIT – Freiburg Center for Interactive Materials and Bioinspired Technologies University of Freiburg Georges‐Köhler‐Allee 105 79110 Freiburg Germany
2 shared publications - Ramendra Sundar Dey
Institute of Nano Science and Technology, Sector-81, Mohali-140306, Punjab, India
2 shared publications - Yangping Wen
Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, Institute of Functional Materials and Agricultural Applied Chemistry, Jiangxi Agricultural University, Nanchang, People’s Republic of China
2 shared publications - Arunas Ramanavicius
Department of Physical Chemistry, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University (VU), Naugarduko str. 24, LT-03225 Vilnius, Lithuania
1 shared publication Dharmalingam Sakthilatha
Department of Chemistry Kandaswami Kandar's College Velur, Namakkal 638182 India
1 shared publication
Latest Publications
- 25 March 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (12)
Advancements in Bioelectrocatalysis for Electrochemical Ammonia Production: Integrating Enzyme‐Based Catalysis
Bioelectrocatalysis has advanced ammonia production by integrating enzyme‐based processes into electrochemical methods, providing chemical manufacturers with a distinct alternative to the traditional Haber–Bosch process. The review discusses the latest developments in enzyme‐based electrochemical catalysis that have been shown to enhance ammonia synthesis, efficiency, and sustainability. We also discuss the development of designed bioelectrocatalysts, including nitrogenase‐inspired enzymes and engineered microbes, which enable the reduction of atmospheric nitrogen to ammonia under mild conditions. Also the study highlights the most recent e‐BNF advancements, focusing on innovations that enhance efficiency and scalability. Nanomaterial integration simplifies ATP‐independent nitrogen fixation, enhancing electron transfer and ammonia production under normal conditions, while also exploring its scalability and implications for green chemistry and industrial applications as a sustainable alternative to the Haber–Bosch process. Eventually, the study discusses the scalability of these technologies and their implications for green chemistry and industrial applications, providing a comprehensive overview of current advancements and future research directions.
- 25 March 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (12)
Advancements in Bioelectrocatalysis for Electrochemical Ammonia Production: Integrating Enzyme‐Based Catalysis
Bioelectrocatalysis has advanced ammonia production by integrating enzyme‐based processes into electrochemical methods, providing chemical manufacturers with a distinct alternative to the traditional Haber–Bosch process. The review discusses the latest developments in enzyme‐based electrochemical catalysis that have been shown to enhance ammonia synthesis, efficiency, and sustainability. We also discuss the development of designed bioelectrocatalysts, including nitrogenase‐inspired enzymes and engineered microbes, which enable the reduction of atmospheric nitrogen to ammonia under mild conditions. Also the study highlights the most recent e‐BNF advancements, focusing on innovations that enhance efficiency and scalability. Nanomaterial integration simplifies ATP‐independent nitrogen fixation, enhancing electron transfer and ammonia production under normal conditions, while also exploring its scalability and implications for green chemistry and industrial applications as a sustainable alternative to the Haber–Bosch process. Eventually, the study discusses the scalability of these technologies and their implications for green chemistry and industrial applications, providing a comprehensive overview of current advancements and future research directions.
- 25 February 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (10) , 2355-2363
Advanced detection of bisphenol A in plastic water bottles using liquid–liquid phase extraction and LC-MS
The release of endocrine-disrupting chemicals (EDCs) can harm humans and wildlife. It is therefore important to monitor bisphenol A (BPA) consumption, an endocrine disruptor commonly found in water from plastic products, and detect BPA at low concentrations for accurate health risk assessments. We present a method for estimating BPA levels in plastic-bottled products that is highly sensitive, precise, and effective. BPA analysis was performed using advanced liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS), with multiple reaction monitoring (MRM) on a state-of-the-art Orbitrap mass spectrometry system using negative ionization techniques. To assess the quality of Indian brands of water, we used LC-MS to obtain balanced hydrophilic–lipophilic extracts. Brand water samples showed efficiently separated BPA in 2.35 minutes, with other sources typically taking between 5 and 8 minutes. BPA concentrations, measured within a range of 10 ng mL−1 to 1 pg mL−1 with a lower detection limit (LOD) of 0.037 ng mL−1, were characterized by dynamic linear ranges and corresponding linear equations for each compound. We also evaluated the reproducibility and sensitivity of the detection of BPA in different water samples, including mineral, river, and tap water, with low levels of BPA found in Indian river water (below 4.54 ng mL−1). Thus, this study explored alternatives to solid phase extraction (SPE) for screening BPA analogs in water samples, and real samples from an Indian supermarket revealed BPA in plastic bottles at concentrations comparable to those described in Europe, the United States, Korea, Japan, and China.
- 25 February 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (10) , 2355-2363
Advanced detection of bisphenol A in plastic water bottles using liquid–liquid phase extraction and LC-MS
The release of endocrine-disrupting chemicals (EDCs) can harm humans and wildlife. It is therefore important to monitor bisphenol A (BPA) consumption, an endocrine disruptor commonly found in water from plastic products, and detect BPA at low concentrations for accurate health risk assessments. We present a method for estimating BPA levels in plastic-bottled products that is highly sensitive, precise, and effective. BPA analysis was performed using advanced liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS), with multiple reaction monitoring (MRM) on a state-of-the-art Orbitrap mass spectrometry system using negative ionization techniques. To assess the quality of Indian brands of water, we used LC-MS to obtain balanced hydrophilic–lipophilic extracts. Brand water samples showed efficiently separated BPA in 2.35 minutes, with other sources typically taking between 5 and 8 minutes. BPA concentrations, measured within a range of 10 ng mL−1 to 1 pg mL−1 with a lower detection limit (LOD) of 0.037 ng mL−1, were characterized by dynamic linear ranges and corresponding linear equations for each compound. We also evaluated the reproducibility and sensitivity of the detection of BPA in different water samples, including mineral, river, and tap water, with low levels of BPA found in Indian river water (below 4.54 ng mL−1). Thus, this study explored alternatives to solid phase extraction (SPE) for screening BPA analogs in water samples, and real samples from an Indian supermarket revealed BPA in plastic bottles at concentrations comparable to those described in Europe, the United States, Korea, Japan, and China.
- Open Access
- 16 January 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (5) , 2658
Correction: One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor
Correction for ‘One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor’ by Jayakumar Kumarasamy, et al., Nanoscale, 2018, DOI: 10.1039/c7nr06952a.
- 16 January 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (5) , 2658
Open AccessCorrection: One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor
Correction for ‘One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor’ by Jayakumar Kumarasamy, et al., Nanoscale, 2018, DOI: 10.1039/c7nr06952a.
- 22 December 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (3) , 1196-1206
One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor
A layer-by-layer (LBL) assembly was employed for preparing multilayer thin films with a controlled architecture and composition. In this study, we report the one-step coelectrodeposition-assisted LBL assembly of both gold nanoparticles (AuNPs) and reduced graphene oxide (rGO) on the surface of a glassy carbon electrode (GCE) for the ultrasensitive electrochemical impedance sensing of DNA hybridization. A self-healable nanohybrid thin film with a three-dimensional (3D) alternate-layered nanoarchitecture was obtained by the one-step simultaneous electro-reduction of both graphene oxide and gold chloride in a high acidic medium of H2SO4 using cyclic voltammetry and was confirmed by different characterization techniques. The DNA bioelectrode was prepared by immobilizing the capture DNA onto the surface of the as-obtained self-healable AuNP/rGO/AuNP/GCE with a 3D LBL nanoarchitecture via gold–thiol interactions, which then served as an impedance sensing platform for the label-free ultrasensitive electrochemical detection of DNA hybridization over a wide range from 1.0 × 10−9 to 1.0 × 10−13 g ml−1, a low limit of detection of 3.9 × 10−14 g ml−1 (S/N = 3), ultrahigh sensitivity, and excellent selectivity. This study presents a promising electrochemical sensing platform for the label-free ultrasensitive detection of DNA hybridization with potential application in cancer diagnostics and the preparation of a self-healable nanohybrid thin film with a 3D alternate-layered nanoarchitecture via a one-step coelectrodeposition-assisted LBL assembly.
- 22 December 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (3) , 1196-1206
One-step coelectrodeposition-assisted layer-by-layer assembly of gold nanoparticles and reduced graphene oxide and its self-healing three-dimensional nanohybrid for an ultrasensitive DNA sensor
A layer-by-layer (LBL) assembly was employed for preparing multilayer thin films with a controlled architecture and composition. In this study, we report the one-step coelectrodeposition-assisted LBL assembly of both gold nanoparticles (AuNPs) and reduced graphene oxide (rGO) on the surface of a glassy carbon electrode (GCE) for the ultrasensitive electrochemical impedance sensing of DNA hybridization. A self-healable nanohybrid thin film with a three-dimensional (3D) alternate-layered nanoarchitecture was obtained by the one-step simultaneous electro-reduction of both graphene oxide and gold chloride in a high acidic medium of H2SO4 using cyclic voltammetry and was confirmed by different characterization techniques. The DNA bioelectrode was prepared by immobilizing the capture DNA onto the surface of the as-obtained self-healable AuNP/rGO/AuNP/GCE with a 3D LBL nanoarchitecture via gold–thiol interactions, which then served as an impedance sensing platform for the label-free ultrasensitive electrochemical detection of DNA hybridization over a wide range from 1.0 × 10−9 to 1.0 × 10−13 g ml−1, a low limit of detection of 3.9 × 10−14 g ml−1 (S/N = 3), ultrahigh sensitivity, and excellent selectivity. This study presents a promising electrochemical sensing platform for the label-free ultrasensitive detection of DNA hybridization with potential application in cancer diagnostics and the preparation of a self-healable nanohybrid thin film with a 3D alternate-layered nanoarchitecture via a one-step coelectrodeposition-assisted LBL assembly.