Abed Khorasani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abed Khorasani has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Reza Daliri
Iran University of Science and Technology
9 shared publications - Vahid Shalchyan
Biomedical Engineering Department, School of Electrical Engineering, Neuroscience & Neuroengineering Research Laboratory, Iran University of Science and Technology, Tehran, Iran
6 shared publications - Soshi Samejima
International Collaboration on Repair Discoveries, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia (BC), Canada
4 shared publications Adrien Boissenin
Department of Rehabilitation Medicine, University of Washington, Seattle, WA, USA
2 shared publications- Chet T. Moritz
Department of Rehabilitation Medicine, University of Washington, Seattle, Washington, USA
2 shared publications Cynthia M. Gorski
Department of Neurology, Northwestern University, Chicago, IL, USA
2 shared publications
Latest Publications
- Open Access
Early Emergence of Abnormal Muscle Synergies in the Human Upper Extremity Following Stroke
Background: Abnormal muscle co-activation, also called abnormal synergies, is an important contributor to arm impairment after stroke. While abnormal co-activation is well-described in chronic stroke, it remains unclear how early abnormal patterns appear and whether their spatial and temporal characteristics resemble those seen in the chronic phase. We sought to determine how soon after stroke abnormal muscle co-activation appears. Methods: In this cross-sectional study, thirty-nine individuals with hemiparesis in the early subacute period (6 months) after stroke performed targeted reaching movements while surface electromyography (EMG) was recorded from nine upper-limb muscles. Muscle synergies (patterns of coordinated muscle activation) were identified using non-negative matrix factorization. Synergy composition (spatial structure) and activation profile (temporal structure) were compared across the contralesional arms of subacute and chronic participants and the ipsilesional arm, which served as the reference for normal coordination. Results: Three primary synergies accounted for most EMG variance during reaching in each arm group. A deltoid-dominant synergy characterized by abnormal co-activation of anterior and posterior deltoids, was present in both subacute and chronic stages in the contralesional arm but was absent in the ipsilesional arm. In addition, the elbow flexor synergy co-activated with the deltoid synergy in both contralesional groups but not in the ipsilesional arm. Abnormal co-activation between elbow flexor and elbow extensor synergies was also seen in contralesional, but not ipsilesional, arms. These abnormalities were already present by 15 days after stroke and did not differ between subacute and chronic groups. Conclusions: Abnormal muscle co-activation appears within the first few weeks after stroke and persists in chronically impaired survivors. Its full development this early suggests these patterns arise rapidly rather than emerging gradually during recovery, and that interventions targeting abnormal co-activation may be most useful when applied early. Clinical Trial Registration: NCT03401762.
Open AccessEarly Emergence of Abnormal Muscle Synergies in the Human Upper Extremity Following Stroke
Background: Abnormal muscle co-activation, also called abnormal synergies, is an important contributor to arm impairment after stroke. While abnormal co-activation is well-described in chronic stroke, it remains unclear how early abnormal patterns appear and whether their spatial and temporal characteristics resemble those seen in the chronic phase. We sought to determine how soon after stroke abnormal muscle co-activation appears. Methods: In this cross-sectional study, thirty-nine individuals with hemiparesis in the early subacute period (6 months) after stroke performed targeted reaching movements while surface electromyography (EMG) was recorded from nine upper-limb muscles. Muscle synergies (patterns of coordinated muscle activation) were identified using non-negative matrix factorization. Synergy composition (spatial structure) and activation profile (temporal structure) were compared across the contralesional arms of subacute and chronic participants and the ipsilesional arm, which served as the reference for normal coordination. Results: Three primary synergies accounted for most EMG variance during reaching in each arm group. A deltoid-dominant synergy characterized by abnormal co-activation of anterior and posterior deltoids, was present in both subacute and chronic stages in the contralesional arm but was absent in the ipsilesional arm. In addition, the elbow flexor synergy co-activated with the deltoid synergy in both contralesional groups but not in the ipsilesional arm. Abnormal co-activation between elbow flexor and elbow extensor synergies was also seen in contralesional, but not ipsilesional, arms. These abnormalities were already present by 15 days after stroke and did not differ between subacute and chronic groups. Conclusions: Abnormal muscle co-activation appears within the first few weeks after stroke and persists in chronically impaired survivors. Its full development this early suggests these patterns arise rapidly rather than emerging gradually during recovery, and that interventions targeting abnormal co-activation may be most useful when applied early. Clinical Trial Registration: NCT03401762.
- Open Access
Wearable Myoelectric Interface for Neurorehabilitation (MINT) to Recover Arm Function: a Randomized Controlled Trial
Background Abnormal muscle co-activation contributes to arm impairment after stroke. This single-blind, randomized, sham-controlled trial evaluated the feasibility and efficacy of home-based, personalized myoelectric interface for neurorehabilitation (MINT) conditioning to reduce abnormal co-activation and enhance arm function and determine the optimal number of abnormally co-activating muscles to target during training. Methods Moderately to severely impaired chronic stroke survivors were randomized to one of three MINT groups (who played customized games requiring independent activation of 2 or 3 abnormally co-activating muscles) or a sham control group (played using one muscle). All groups trained 90 minutes/day, 5 days/week at home and 1 day/week in lab, for 6 weeks, and changed trained muscle sets every 2-3 weeks. The primary outcome was the Wolf Motor Function Test (WMFT) at 6 weeks. Results Fifty-nine participants completed the training. Participants performed 315 ± 85 (mean ± SD) repetitions daily. At week 6, participants in all MINT groups combined improved by 4 s on WMFT (p=0.0008), exceeding the minimal clinically important difference (1.5 s). Participants who trained 3 muscles simultaneously improved by 6.8 s (p=0.001), while the 2-muscle and sham groups did not change significantly. In per-protocol analysis, the 3-muscle group, but not 2-muscle groups, improved significantly more than sham (p=0.046), though not in intention-to-treat analysis. All MINT groups continued improving at 4 weeks post-training. Importantly, severely impaired participants in combined MINT groups improved more than those in sham (p=0.02). Importantly, combined MINT groups also improved their reaching range of motion significantly more than sham. Co-activation decreased by 76% in MINT groups during training. Notably, reduction in co-activation during reaching correlated significantly with improved arm function and range of motion. Other secondary outcomes did not show clinically important improvement. Stroke involving the posterior limb of the internal capsule negatively predicted response to MINT. Conclusions Home-based MINT conditioning, especially the 3-muscle variant, is feasible, reduces co-activation, and improves arm movement and function. Clinical Trial Registration ClinicalTrials.gov (NCT03401762)
Open AccessWearable Myoelectric Interface for Neurorehabilitation (MINT) to Recover Arm Function: a Randomized Controlled Trial
Background Abnormal muscle co-activation contributes to arm impairment after stroke. This single-blind, randomized, sham-controlled trial evaluated the feasibility and efficacy of home-based, personalized myoelectric interface for neurorehabilitation (MINT) conditioning to reduce abnormal co-activation and enhance arm function and determine the optimal number of abnormally co-activating muscles to target during training. Methods Moderately to severely impaired chronic stroke survivors were randomized to one of three MINT groups (who played customized games requiring independent activation of 2 or 3 abnormally co-activating muscles) or a sham control group (played using one muscle). All groups trained 90 minutes/day, 5 days/week at home and 1 day/week in lab, for 6 weeks, and changed trained muscle sets every 2-3 weeks. The primary outcome was the Wolf Motor Function Test (WMFT) at 6 weeks. Results Fifty-nine participants completed the training. Participants performed 315 ± 85 (mean ± SD) repetitions daily. At week 6, participants in all MINT groups combined improved by 4 s on WMFT (p=0.0008), exceeding the minimal clinically important difference (1.5 s). Participants who trained 3 muscles simultaneously improved by 6.8 s (p=0.001), while the 2-muscle and sham groups did not change significantly. In per-protocol analysis, the 3-muscle group, but not 2-muscle groups, improved significantly more than sham (p=0.046), though not in intention-to-treat analysis. All MINT groups continued improving at 4 weeks post-training. Importantly, severely impaired participants in combined MINT groups improved more than those in sham (p=0.02). Importantly, combined MINT groups also improved their reaching range of motion significantly more than sham. Co-activation decreased by 76% in MINT groups during training. Notably, reduction in co-activation during reaching correlated significantly with improved arm function and range of motion. Other secondary outcomes did not show clinically important improvement. Stroke involving the posterior limb of the internal capsule negatively predicted response to MINT. Conclusions Home-based MINT conditioning, especially the 3-muscle variant, is feasible, reduces co-activation, and improves arm movement and function. Clinical Trial Registration ClinicalTrials.gov (NCT03401762)
- Open Access
- 14 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31  (15344320) , 620-627
Glassy Carbon Neural Interface for Chronic Epidural Stimulation in Rats With Cervical Spinal Cord Injury
There is growing evidence on the efficacy of electrical stimulation delivered via spinal neural interfaces to improve functional recovery following spinal cord injury. For such interfaces, carbon-based neural arrays are fast becoming recognized as a compelling material and platform due to biocompatibility and long-term electrochemical stability. Here, we introduce the design, fabrication, and in vivo characterization of a novel cervical epidural implant with carbon-based surface electrodes. Through finite element analysis and mechanical load tests, we demonstrated that the array could safely withstand loads applied to it during implantation and natural movement of the subject with minimal stress levels. Furthermore, the long-term in vivo performance of this neural array consisting of glassy carbon surface electrodes was investigated through acute and chronic spinal motor evoked potential recordings and electrode impedance tests in rats. We demonstrated stable stimulation performance for at least four weeks in a rat model of spinal cord injury. Lastly, we found that impedance measurements on all carbon-based spinal arrays were generally stable over time up to four weeks after implantation, with a slight increase in impedance in subsequent weeks when tested in spinally injured rats. Taken together, this study demonstrated the potential for carbon-based electrodes as a spinal neural interface to accelerate both mechanistic research and functional restoration in animal models of spinal cord injury.
- 14 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31  (15344320) , 620-627
Open AccessGlassy Carbon Neural Interface for Chronic Epidural Stimulation in Rats With Cervical Spinal Cord Injury
There is growing evidence on the efficacy of electrical stimulation delivered via spinal neural interfaces to improve functional recovery following spinal cord injury. For such interfaces, carbon-based neural arrays are fast becoming recognized as a compelling material and platform due to biocompatibility and long-term electrochemical stability. Here, we introduce the design, fabrication, and in vivo characterization of a novel cervical epidural implant with carbon-based surface electrodes. Through finite element analysis and mechanical load tests, we demonstrated that the array could safely withstand loads applied to it during implantation and natural movement of the subject with minimal stress levels. Furthermore, the long-term in vivo performance of this neural array consisting of glassy carbon surface electrodes was investigated through acute and chronic spinal motor evoked potential recordings and electrode impedance tests in rats. We demonstrated stable stimulation performance for at least four weeks in a rat model of spinal cord injury. Lastly, we found that impedance measurements on all carbon-based spinal arrays were generally stable over time up to four weeks after implantation, with a slight increase in impedance in subsequent weeks when tested in spinally injured rats. Taken together, this study demonstrated the potential for carbon-based electrodes as a spinal neural interface to accelerate both mechanistic research and functional restoration in animal models of spinal cord injury.
- Open Access
- 17 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29  (15344320) , 1233-1242
Brain-Computer-Spinal Interface Restores Upper Limb Function After Spinal Cord Injury
Brain-computer interfaces (BCIs) are an emerging strategy for spinal cord injury (SCI) intervention that may be used to reanimate paralyzed limbs. This approach requires decoding movement intention from the brain to control movement-evoking stimulation. Common decoding methods use spike-sorting and require frequent calibration and high computational complexity. Furthermore, most applications of closed-loop stimulation act on peripheral nerves or muscles, resulting in rapid muscle fatigue. Here we show that a local field potential-based BCI can control spinal stimulation and improve forelimb function in rats with cervical SCI. We decoded forelimb movement via multi-channel local field potentials in the sensorimotor cortex using a canonical correlation analysis algorithm. We then used this decoded signal to trigger epidural spinal stimulation and restore forelimb movement. Finally, we implemented this closed-loop algorithm in a miniaturized onboard computing platform. This Brain-Computer-Spinal Interface (BCSI) utilized recording and stimulation approaches already used in separate human applications. Our goal was to demonstrate a potential neuroprosthetic intervention to improve function after upper extremity paralysis.
- 17 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29  (15344320) , 1233-1242
Open AccessBrain-Computer-Spinal Interface Restores Upper Limb Function After Spinal Cord Injury
Brain-computer interfaces (BCIs) are an emerging strategy for spinal cord injury (SCI) intervention that may be used to reanimate paralyzed limbs. This approach requires decoding movement intention from the brain to control movement-evoking stimulation. Common decoding methods use spike-sorting and require frequent calibration and high computational complexity. Furthermore, most applications of closed-loop stimulation act on peripheral nerves or muscles, resulting in rapid muscle fatigue. Here we show that a local field potential-based BCI can control spinal stimulation and improve forelimb function in rats with cervical SCI. We decoded forelimb movement via multi-channel local field potentials in the sensorimotor cortex using a canonical correlation analysis algorithm. We then used this decoded signal to trigger epidural spinal stimulation and restore forelimb movement. Finally, we implemented this closed-loop algorithm in a miniaturized onboard computing platform. This Brain-Computer-Spinal Interface (BCSI) utilized recording and stimulation approaches already used in separate human applications. Our goal was to demonstrate a potential neuroprosthetic intervention to improve function after upper extremity paralysis.
- Open Access
- 25 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 159089-159099
State-Based Decoding of Force Signals From Multi-Channel Local Field Potentials
The functional use of brain-machine interfaces (BMIs) in everyday tasks requires the accurate decoding of both movement and force information. In real-word tasks such as reach-to-grasp movements, a prosthetic hand should be switched between reaching and grasping modes, depending on the detection of the user intents in the decoder part of the BMI. Therefore, it is important to detect the rest or active states of different actions in the decoder to produce the corresponding continuous command output during the estimated state. In this study, we demonstrated that the resting and force-generating time-segments in a key pressing task could be accurately detected from local field potentials (LFPs) in rat’s primary motor cortex. Common spatial pattern (CSP) algorithm was applied on different spectral LFP sub-bands to maximize the difference between the two classes of force and rest. We also showed that combining a discrete state decoder with linear or non-linear continuous force variable decoders could lead to a higher force decoding performance compared with the case we use a continuous variable decoder only. Moreover, the results suggest that gamma LFP signals (50-100 Hz) could be used successfully for decoding the discrete rest/force states as well as continuous values of the force variable. The results of this study can offer substantial benefits for the implementation of a self-paced, force-related command generator in BMI experiments without the need for manual external signals to select the state of the decoder.
- 25 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 159089-159099
Open AccessState-Based Decoding of Force Signals From Multi-Channel Local Field Potentials
The functional use of brain-machine interfaces (BMIs) in everyday tasks requires the accurate decoding of both movement and force information. In real-word tasks such as reach-to-grasp movements, a prosthetic hand should be switched between reaching and grasping modes, depending on the detection of the user intents in the decoder part of the BMI. Therefore, it is important to detect the rest or active states of different actions in the decoder to produce the corresponding continuous command output during the estimated state. In this study, we demonstrated that the resting and force-generating time-segments in a key pressing task could be accurately detected from local field potentials (LFPs) in rat’s primary motor cortex. Common spatial pattern (CSP) algorithm was applied on different spectral LFP sub-bands to maximize the difference between the two classes of force and rest. We also showed that combining a discrete state decoder with linear or non-linear continuous force variable decoders could lead to a higher force decoding performance compared with the case we use a continuous variable decoder only. Moreover, the results suggest that gamma LFP signals (50-100 Hz) could be used successfully for decoding the discrete rest/force states as well as continuous values of the force variable. The results of this study can offer substantial benefits for the implementation of a self-paced, force-related command generator in BMI experiments without the need for manual external signals to select the state of the decoder.
- Open Access
- 16 April 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 350
Adaptive Artifact Removal From Intracortical Channels for Accurate Decoding of a Force Signal in Freely Moving Rats
Intracortical data recorded with multi-electrode arrays provide rich information about kinematic and kinetic states of movement in the brain–machine interface (BMI) systems. Direct estimation of kinetic information such as the force from cortical data has the same importance as kinematic information to make a functional BMI system. Various types of the information including single unit activity (SUA), multiunit activity (MUA) and local field potential (LFP) can be used as an input information to extract motor commands for control of the external devices in BMI. Here we combine LFP and MUA information to improve decoding accuracy of the force signal from the multi-channel intracortical data of freely moving rats. We suggest a weighted common average referencing (CAR) algorithm in order to valid interpretation of the force decoding from different data types. The proposed spatial filter adaptively identifies contribution of the common noise on the channels employing Kalman filter method. We evaluated the efficacy of the proposed artifact algorithm on both simulation and real data. In the simulation study, the average R2 between the original and reconstructed signal of all channels after applying the proposed artifact removal method was computed for input SNRs in the range of −45 to 0 dB. Weighted CAR method can effectively reconstruct the original signal with average R2 higher than 0.5 for input SNRs higher than −10 dB in case of adding simulated outlier and motion artifacts. We also show that the proposed artifact removal algorithm 33% improves the accuracy of force decoding in terms of R2 value compared to standard CAR filters.
- 16 April 2019
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 350
Open AccessAdaptive Artifact Removal From Intracortical Channels for Accurate Decoding of a Force Signal in Freely Moving Rats
Intracortical data recorded with multi-electrode arrays provide rich information about kinematic and kinetic states of movement in the brain–machine interface (BMI) systems. Direct estimation of kinetic information such as the force from cortical data has the same importance as kinematic information to make a functional BMI system. Various types of the information including single unit activity (SUA), multiunit activity (MUA) and local field potential (LFP) can be used as an input information to extract motor commands for control of the external devices in BMI. Here we combine LFP and MUA information to improve decoding accuracy of the force signal from the multi-channel intracortical data of freely moving rats. We suggest a weighted common average referencing (CAR) algorithm in order to valid interpretation of the force decoding from different data types. The proposed spatial filter adaptively identifies contribution of the common noise on the channels employing Kalman filter method. We evaluated the efficacy of the proposed artifact algorithm on both simulation and real data. In the simulation study, the average R2 between the original and reconstructed signal of all channels after applying the proposed artifact removal method was computed for input SNRs in the range of −45 to 0 dB. Weighted CAR method can effectively reconstruct the original signal with average R2 higher than 0.5 for input SNRs higher than −10 dB in case of adding simulated outlier and motion artifacts. We also show that the proposed artifact removal algorithm 33% improves the accuracy of force decoding in terms of R2 value compared to standard CAR filters.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 791-794
NeuralCLIP: A Modular FPGA-Based Neural Interface for Closed-Loop Operation
The need for a miniaturized device that can perform closed-loop operation is imminent with the growing interest in brain-controlled devices and in stimulation to treat neural disorders. This work presents the Neural Closed-Loop Implantable Platform (NeuralCLIP), a modular FPGA-based device that can record neural signals, process them locally to detect an event and trigger neural stimulation based on the detection. Specifically, the NeuralCLIP is designed to record and process different neural signals in the frequency range between 20 Hz and 1 kHz. It is a flexible platform that can be reconfigured to optimize parameters like channel count and operation frequency based on the processing requirements. The signal-agnostic feature is demonstrated by testing the device with calibration signals from standard bio-signal emulators. The application focus for this device is a brain-computer-spinal interface (BCSI) which is demonstrated based on local field potential (LFP) signals recorded from a rat motor cortex. This work demonstrates recording and on-device processing of LFP signals to decode action intent and determine stimulation timing. The FPGA implementation of the device also targets development of low power algorithms for closed-loop operation.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 791-794
NeuralCLIP: A Modular FPGA-Based Neural Interface for Closed-Loop Operation
The need for a miniaturized device that can perform closed-loop operation is imminent with the growing interest in brain-controlled devices and in stimulation to treat neural disorders. This work presents the Neural Closed-Loop Implantable Platform (NeuralCLIP), a modular FPGA-based device that can record neural signals, process them locally to detect an event and trigger neural stimulation based on the detection. Specifically, the NeuralCLIP is designed to record and process different neural signals in the frequency range between 20 Hz and 1 kHz. It is a flexible platform that can be reconfigured to optimize parameters like channel count and operation frequency based on the processing requirements. The signal-agnostic feature is demonstrated by testing the device with calibration signals from standard bio-signal emulators. The application focus for this device is a brain-computer-spinal interface (BCSI) which is demonstrated based on local field potential (LFP) signals recorded from a rat motor cortex. This work demonstrates recording and on-device processing of LFP signals to decode action intent and determine stimulation timing. The FPGA implementation of the device also targets development of low power algorithms for closed-loop operation.
- Open Access
- 3 May 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8  (1) , 6958
Ultra-Capacitive Carbon Neural Probe Allows Simultaneous Long-Term Electrical Stimulations and High-Resolution Neurotransmitter Detection
We present a new class of carbon-based neural probes that consist of homogeneous glassy carbon (GC) microelectrodes, interconnects and bump pads. These electrodes have purely capacitive behavior with exceptionally high charge storage capacity (CSC) and are capable of sustaining more than 3.5 billion cycles of bi-phasic pulses at charge density of 0.25 mC/cm2. These probes enable both high SNR (>16) electrical signal recording and remarkably high-resolution real-time neurotransmitter detection, on the same platform. Leveraging a new 2-step, double-sided pattern transfer method for GC structures, these probes allow extended long-term electrical stimulation with no electrode material corrosion. Cross-section characterization through FIB and SEM imaging demonstrate strong attachment enabled by hydroxyl and carbonyl covalent bonds between GC microstructures and top insulating and bottom substrate layers. Extensive in-vivo and in-vitro tests confirmed: (i) high SNR (>16) recordings, (ii) highest reported CSC for non-coated neural probe (61.4 ± 6.9 mC/cm2), (iii) high-resolution dopamine detection (10 nM level - one of the lowest reported so far), (iv) recording of both electrical and electrochemical signals, and (v) no failure after 3.5 billion cycles of pulses. Therefore, these probes offer a compelling multi-modal platform for long-term applications of neural probe technology in both experimental and clinical neuroscience.
- 3 May 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8  (1) , 6958
Open AccessUltra-Capacitive Carbon Neural Probe Allows Simultaneous Long-Term Electrical Stimulations and High-Resolution Neurotransmitter Detection
We present a new class of carbon-based neural probes that consist of homogeneous glassy carbon (GC) microelectrodes, interconnects and bump pads. These electrodes have purely capacitive behavior with exceptionally high charge storage capacity (CSC) and are capable of sustaining more than 3.5 billion cycles of bi-phasic pulses at charge density of 0.25 mC/cm2. These probes enable both high SNR (>16) electrical signal recording and remarkably high-resolution real-time neurotransmitter detection, on the same platform. Leveraging a new 2-step, double-sided pattern transfer method for GC structures, these probes allow extended long-term electrical stimulation with no electrode material corrosion. Cross-section characterization through FIB and SEM imaging demonstrate strong attachment enabled by hydroxyl and carbonyl covalent bonds between GC microstructures and top insulating and bottom substrate layers. Extensive in-vivo and in-vitro tests confirmed: (i) high SNR (>16) recordings, (ii) highest reported CSC for non-coated neural probe (61.4 ± 6.9 mC/cm2), (iii) high-resolution dopamine detection (10 nM level - one of the lowest reported so far), (iv) recording of both electrical and electrochemical signals, and (v) no failure after 3.5 billion cycles of pulses. Therefore, these probes offer a compelling multi-modal platform for long-term applications of neural probe technology in both experimental and clinical neuroscience.
- 12 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 26  (1) , 18-25
Brain Control of an External Device by Extracting the Highest Force-Related Contents of Local Field Potentials in Freely Moving Rats
A local field potential (LFP) signal is an alternative source to neural action potentials for decoding kinematic and kinetic information from the brain. Here we demonstrate that better extraction of force-related features from multichannel LFPs improves the accuracy of force decoding. We propose that applying canonical correlation analysis (CCA) filter on the envelopes of separate frequency bands (band-specific CCA) seperates non- task related information from the LFPs. The decoding accuracy of the continuous force signal based on the proposed method were compared with three feature reduction methods: 1) Band-specific principal component analysis (bandspecific PCA) method that extract the components which leads to maximum variance from envelopes of different frequency bands, 2) Correlation coefficient-based (CC-based) feature reduction that selects the best features from the envelopes sorted based on the absolute correlation coefficient between each envelope and the target force signal and 3) Mutual information –based (MI-based) feature reduction that selects the best features from the envelopes sorted based on the mutual information between each envelope and output force signal. The band-specific CCA method outperformed band-specific PCA with 11% improvement, CC-based feature reduction with 16% improvement and MI –based feature reduction with 18% improvement. In the online brain control experiments, the realtime decoded force signal from the 16-channel LFPs based on the proposed method was used to move a mechanical arm. Two rats performed 88 trials in 7 sessions to control the mechanical arm based on the 16-channel LFPs.
- 12 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 26  (1) , 18-25
Brain Control of an External Device by Extracting the Highest Force-Related Contents of Local Field Potentials in Freely Moving Rats
A local field potential (LFP) signal is an alternative source to neural action potentials for decoding kinematic and kinetic information from the brain. Here we demonstrate that better extraction of force-related features from multichannel LFPs improves the accuracy of force decoding. We propose that applying canonical correlation analysis (CCA) filter on the envelopes of separate frequency bands (band-specific CCA) seperates non- task related information from the LFPs. The decoding accuracy of the continuous force signal based on the proposed method were compared with three feature reduction methods: 1) Band-specific principal component analysis (bandspecific PCA) method that extract the components which leads to maximum variance from envelopes of different frequency bands, 2) Correlation coefficient-based (CC-based) feature reduction that selects the best features from the envelopes sorted based on the absolute correlation coefficient between each envelope and the target force signal and 3) Mutual information –based (MI-based) feature reduction that selects the best features from the envelopes sorted based on the mutual information between each envelope and output force signal. The band-specific CCA method outperformed band-specific PCA with 11% improvement, CC-based feature reduction with 16% improvement and MI –based feature reduction with 18% improvement. In the online brain control experiments, the realtime decoded force signal from the 16-channel LFPs based on the proposed method was used to move a mechanical arm. Two rats performed 88 trials in 7 sessions to control the mechanical arm based on the 16-channel LFPs.
- Open Access
- 21 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6  (1) , 35238
Continuous Force Decoding from Local Field Potentials of the Primary Motor Cortex in Freely Moving Rats
Local field potential (LFP) signals recorded by intracortical microelectrodes implanted in primary motor cortex can be used as a high informative input for decoding of motor functions. Recent studies show that different kinematic parameters such as position and velocity can be inferred from multiple LFP signals as precisely as spiking activities, however, continuous decoding of the force magnitude from the LFP signals in freely moving animals has remained an open problem. Here, we trained three rats to press a force sensor for getting a drop of water as a reward. A 16-channel micro-wire array was implanted in the primary motor cortex of each trained rat, and obtained LFP signals were used for decoding of the continuous values recorded by the force sensor. Average coefficient of correlation and the coefficient of determination between decoded and actual force signals were r = 0.66 and R2 = 0.42, respectively. We found that LFP signal on gamma frequency bands (30–120 Hz) had the most contribution in the trained decoding model. This study suggests the feasibility of using low number of LFP channels for the continuous force decoding in freely moving animals resembling BMI systems in real life applications.
- 21 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6  (1) , 35238
Open AccessContinuous Force Decoding from Local Field Potentials of the Primary Motor Cortex in Freely Moving Rats
Local field potential (LFP) signals recorded by intracortical microelectrodes implanted in primary motor cortex can be used as a high informative input for decoding of motor functions. Recent studies show that different kinematic parameters such as position and velocity can be inferred from multiple LFP signals as precisely as spiking activities, however, continuous decoding of the force magnitude from the LFP signals in freely moving animals has remained an open problem. Here, we trained three rats to press a force sensor for getting a drop of water as a reward. A 16-channel micro-wire array was implanted in the primary motor cortex of each trained rat, and obtained LFP signals were used for decoding of the continuous values recorded by the force sensor. Average coefficient of correlation and the coefficient of determination between decoded and actual force signals were r = 0.66 and R2 = 0.42, respectively. We found that LFP signal on gamma frequency bands (30–120 Hz) had the most contribution in the trained decoding model. This study suggests the feasibility of using low number of LFP channels for the continuous force decoding in freely moving animals resembling BMI systems in real life applications.