Jun Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jun Xu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Xiangmei Dong
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
2 shared publicationsXiangyu Kang
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
2 shared publications- Xiumin Gao
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
2 shared publications - Yang Li
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China
2 shared publications Zhanfei Zhang
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
2 shared publications- Zhengkun Fan
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
2 shared publications
Latest Publications
- 13 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4412-4424
Design of Highly Uniform Magnetic Field Coils With Wolf Pack Algorithm
Uniform magnetic fields are widely used in atomic magnetometers, MRI and other fields. The traditional method of solving closed-form equations is usually used to design highly uniform magnetic field coils. In this paper, a new intelligent algorithm, wolf pack algorithm (WPA), is proposed to design the coil structure of a highly uniform magnetic field. This method can replace the traditional method to obtain the coil parameters. We additionally use a discrete optimization method to solve the rounding error. According to the investigation, compared with particle swarm optimization (PSO) algorithm, WPA has stronger global optimization ability, faster convergence speed and multiple optimization strategies. We set appropriate coil constraints (structural and process constraints) and simplify the multi-dimensional solutions to one-dimensional solutions to reduce the difficulty of operation. The distribution of magnetic field intensity of three axes of coils is analyzed by the finite element analysis method, and the 1%, 0.1%, and 0.01% uniform regions are studied. Under the same conditions, the uniform magnetic field regions of the coils designed by the PSO and WPA, as well as a single pair of axial and radial coils are compared. The performance results of multiple pairs of coils are superior to those of a single pair of coils. In general, the uniformity of the axial and radial magnetic field coils designed by the WPA is better than that designed by the PSO. Finally, the experimental value of the magnetic field uniformity is nearly consistent with the theoretical value.
- 13 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4412-4424
Design of Highly Uniform Magnetic Field Coils With Wolf Pack Algorithm
Uniform magnetic fields are widely used in atomic magnetometers, MRI and other fields. The traditional method of solving closed-form equations is usually used to design highly uniform magnetic field coils. In this paper, a new intelligent algorithm, wolf pack algorithm (WPA), is proposed to design the coil structure of a highly uniform magnetic field. This method can replace the traditional method to obtain the coil parameters. We additionally use a discrete optimization method to solve the rounding error. According to the investigation, compared with particle swarm optimization (PSO) algorithm, WPA has stronger global optimization ability, faster convergence speed and multiple optimization strategies. We set appropriate coil constraints (structural and process constraints) and simplify the multi-dimensional solutions to one-dimensional solutions to reduce the difficulty of operation. The distribution of magnetic field intensity of three axes of coils is analyzed by the finite element analysis method, and the 1%, 0.1%, and 0.01% uniform regions are studied. Under the same conditions, the uniform magnetic field regions of the coils designed by the PSO and WPA, as well as a single pair of axial and radial coils are compared. The performance results of multiple pairs of coils are superior to those of a single pair of coils. In general, the uniformity of the axial and radial magnetic field coils designed by the WPA is better than that designed by the PSO. Finally, the experimental value of the magnetic field uniformity is nearly consistent with the theoretical value.
- Open Access
- 12 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 187876-187881
Multilayer Spindle Shaped Magnetic Shielding Device for SERF Atomic Magnetometer Application
Most of shielding devices currently used for SERF magnetometers are multilayer cylindrical magnetic shielding barrels. This paper studies a new multilayer spindle shaped magnetic shielding barrel for the spin exchange relaxation free (SERF) magnetometer shielding system and uses finite element method (FEM) to compare the analysis results. The results show that the shielding effect of the spindle shaped magnetic shielding barrel is better than the traditional cylindrical magnetic shielding barrel, while the volume is reduced by about 1/5 and the weight is reduced by about 1/4. Therefore, we expect that a small-sized, light-weight, low-cost and more efficient magnetic shielding device can be obtained.
- 12 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 187876-187881
Open AccessMultilayer Spindle Shaped Magnetic Shielding Device for SERF Atomic Magnetometer Application
Most of shielding devices currently used for SERF magnetometers are multilayer cylindrical magnetic shielding barrels. This paper studies a new multilayer spindle shaped magnetic shielding barrel for the spin exchange relaxation free (SERF) magnetometer shielding system and uses finite element method (FEM) to compare the analysis results. The results show that the shielding effect of the spindle shaped magnetic shielding barrel is better than the traditional cylindrical magnetic shielding barrel, while the volume is reduced by about 1/5 and the weight is reduced by about 1/4. Therefore, we expect that a small-sized, light-weight, low-cost and more efficient magnetic shielding device can be obtained.
- 24 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10457, 104573A
Modulated visible spectra properties of Pr:Ca1-xRxF2+x(R=Y, La, Gd) crystals
The spectroscopic properties of the 1.0 at.%Pr:Ca0.97R0.02F2.03(R=Y, La, Gd) crystals are investigated. X-diffraction and room temperature absorption spectra have been registered and analyzed. The emission spectra and decay curves of the crystals were obtained at room temperature. The photoluminescence intensity in the visible region is significantly enhanced by co-doping R3+ ions in Pr:CaF2 crystal. The different effects among the R3+ (Y3+, La3+ and Gd3+) regulating ions on the crystals were observed and compared. Pr:Ca0.97La0.02F2.03 and Pr:Ca0.97Y0.02F2.03 crystals have substantially strong emission at blue and orange region, while the Pr:Ca0.97Gd0.02F2.03 crystal is more suitable for the red emission emitting.
- 24 October 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10457, 104573A
Modulated visible spectra properties of Pr:Ca1-xRxF2+x(R=Y, La, Gd) crystals
The spectroscopic properties of the 1.0 at.%Pr:Ca0.97R0.02F2.03(R=Y, La, Gd) crystals are investigated. X-diffraction and room temperature absorption spectra have been registered and analyzed. The emission spectra and decay curves of the crystals were obtained at room temperature. The photoluminescence intensity in the visible region is significantly enhanced by co-doping R3+ ions in Pr:CaF2 crystal. The different effects among the R3+ (Y3+, La3+ and Gd3+) regulating ions on the crystals were observed and compared. Pr:Ca0.97La0.02F2.03 and Pr:Ca0.97Y0.02F2.03 crystals have substantially strong emission at blue and orange region, while the Pr:Ca0.97Gd0.02F2.03 crystal is more suitable for the red emission emitting.