HUHiroaki Uehara

Hiroaki Uehara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroaki Uehara has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Molecular dynamics study on anisotropic water cluster formation in polyethylene: A fundamental perspective on water tree initiation

    by Shinya Iwata, Ryota Kitani, Tomoka Tsuya, Hiroaki Uehara, Tatsuki Okamoto, Tatsuo Takada

    The microscopic mechanisms of water tree inception in polymeric insulating materials remain a critical challenge for high-voltage engineering. In this study, molecular dynamics simulations were employed to investigate the structural and kinetic responses of water nanoclusters in a polyethylene matrix to external electric fields (0 and 2 V/nm). We demonstrate a fundamental disparity between ion-free pure water and ion-containing (Na+ and SO42−) clusters. In pure water systems, external fields induce macroscopic elongation along the field direction, accompanied by a reduction in the activation energy for hydrogen-bond dissociation. This field-induced dynamic softening kinetically facilitates continuous structural reorganization. Conversely, in ion-containing systems, the intense Coulombic attraction of the ions forms an electrostatically locked “hydration core.” This core exhibits an anomalously high activation energy that remains robustly intact even under 2 V/nm fields, causing kinematic freezing of the cluster’s morphology. These findings suggest that while pure water possesses the kinetic flexibility to undergo one-dimensional anisotropic growth under electrical stress, ionic impurities act as stable, non-deformable aggregation centers. Such contrasting dynamic behaviors provide a fundamental perspective on the initial cluster stabilization and directional elongation processes associated with water tree initiation.

  • Influence of moisture and ionic stresses on the defect-driven failure of PI and PEN films: bulk charge dynamics and surface partial discharge

    by Shinya Iwata, Ryota Kitani, Tomoka Tsuya, Hiroaki Uehara, Tatsuki Okamoto, Tatsuo Takada

    Environmental degradation of polymer insulators under moisture and ionic contaminants poses a critical challenge to the reliability of high-voltage applications. This study systematically investigates and compares the dielectric and surface partial discharge degradation mechanisms of polyimide (PI) and polyethylene naphthalate (PEN) films subjected to thermal (90 ∘ C), wet (deionized water), and ionic (5 wt% NaCl) stresses. Time-dependent current integration ( Q ( t ) ) data reveal that while PI suffers from a massive surge in leakage current with an extraordinary coefficient of variation, PEN maintains exceptional bulk insulation stability due to its rigid molecular structure. AC dielectric breakdown analysis shows that environmental stresses cause a severe reduction in the Weibull shape parameter, indicating a transition from intrinsic electronic avalanche processes to a defect-driven failure mode induced by electric field enhancement. Crucially, objective model selection utilizing information criteria reveals a fundamental mechanistic discrepancy between the static inception (PDIV) and dynamic extinction (PDEV) thresholds. While moisture absorption alone preserves the baseline PDIV, localized ionic residues act as severe electric field enhancement sites, triggering premature stochastic inception. Conversely, PDEV is profoundly governed by dynamic surface charge relaxation. It is hypothesized that trace amounts of residual bound water alter surface charge diffusion and trap injected charges, severely degrading the PDEV into a mixed-Weibull framework for both materials. Furthermore, under NaCl treatment, the ion-moisture synergy in PI promotes rapid charge dissipation and PDEV recovery, whereas the hydrophobic nature of PEN sustains isolated charge traps and hinders extinction. These findings phenomenologically link inferred microscopic surface states to macroscopic statistical lifespans, providing vital guidelines for next-generation high-voltage insulation design.


  • Open Access

    Filtering of Q(t) Measurement Data for Estimating Leakage Current

    by Ryota Kitani, Shinya Iwata, Tomoka Tsuya, Hiroaki Uehara, Tatsuki Okamoto

    Q(t) measurement has been developed as a diagnostic technique for electrical insulators in DC applications, and is widely used to compare the relative properties of polymeric samples under high voltage; however, its conventional usage is limited to analyzing the charge amount compared to the space charge phenomenon. Conversely, Q(t) measurement can also serve as a diagnostic tool for leakage current through insulation materials because of its relatively high precision; hence, this study focuses on utilizing this method as an online abnormal detector. However, first, noisy data resulting from variable circumstances remains a challenge, even when simple low-pass filters are applied. This study ensures noise reduction by assuming an ordinary differential equation model and applying Kalman filters/Rauch–Tung–Striebel (RTS) smoothers to the experimental data of a polyimide sheet sample. Filtering/smoothing reduces the noise level to less than 1/900 of the simple first-difference data when an RTS smoother is applied, according to the comparison method that utilizes linearly-approximated data. Then, fixed-lag smoothers are applied, generally obtaining more smoothed data than that of the Kalman filter. Through the filtered results and Kalman filters’ property as an adaptive low-pass filter, a direction for filter designing is proposed, which depends on ‘process noise to the 2nd power’ / ‘observation noise.’ The filtering/evaluation/designing methods utilized in this study are beneficial for more precise diagnoses and are expected to provide a foundation for online leakage current detection.


  • Open Access

    Fast Pulse-Widths of Partial Discharges Using Needle-Plane Electrodes With Different Tip Radius Over Polyimide Film

    by Tatsuki Okamoto, Hiroaki Uehara, Yuta Makino, Toshihiro Takahashi

    Partial discharge (PD) has been analyzed for many years; however, it is still difficult to understand clearly because it strongly depends on experimental conditions. To understand PD characteristics better, we directly measure fast-PD current waveforms on the order of nanoseconds instead of PD charge amounts. These fast-PD current peak measurements may provide us the deep understanding of the PD mechanism under different electric field strengths with different tip-radiuses and discharge gaps. Recent advances in high-speed oscilloscopes now enable nanosecond-scale pulse measurements under appropriate conditions. In this study, the PD measurement circuit is minimized to ensure accurate peak acquisition, reducing the total length of the circuit-flow path to less than 150 mm. A simple needle-plane electrode is used with discharge gaps ranging from 0 to 150 μm. The needle electrode has a diameter of 1 mm with several tip radii of 30, 100, 300 and 500 μm. An AC voltage with peak amplitudes of 2 kV at 50–1000 Hz is applied, and a 100-μm-thick polyimide film is employed as the insulating specimen. The measured new PD characteristics are the peak time that is the time interval between pulse detection to pulse peak and the half-maximum pulse widths of the fast PD current pulse. The peak time shows relatively small variation, between 4 ns and 6 ns across all electrode conditions. In contrast, pulse widths are approximately 5-15 ns, depending on conditions such as dischargegap length and needle tip radius. Moreover, the dependence of these times on AC voltage frequency is consistently small, suggesting that accelerated testing using higher AC frequencies up to 1000 Hz may be effective for estimating insulation lifetime under PD stress for this electrode configuration.


  • Charge Characteristics in Low-Density Polyethylene With and Without Antioxidant Using Current Integration Method

    by Hiroaki Uehara, Shinya Iwata, Ryota Kitani, Tomoka Tsuya, Tatsuki Okamoto, Tatsuo Takada

    Measurement data on charge characteristics in the insulation layers of power devices, DC power cables, and enamel windings of electric vehicle drive motors under strong electric fields, high temperatures, and long-term voltage applications are critically important. The current integration method used in this study can measure both fast-moving carrier charges (shallow-trapped charges) and accumulated charges (deep-trapped charges). While the existing pulsed electro-acoustic method is excellent for observing the distribution of accumulated charges, it has difficulty measuring carrier charges moving at high speeds. In this study, we measure the charge characteristics of low-density polyethylene (LDPE) with and without phenolic antioxidants using the current integration method. Antioxidants are typically added to suppress material oxidation. However, the results show that they also suppress charge characteristics. Although a chemical analysis using differential scanning calorimetry reveals that the melting and crystallization temperatures of LDPE do not change significantly, its melting enthalpy and degree of crystallinity are higher in the presence of antioxidants than in their absence. The increase in crystallinity due to antioxidants suppresses the temperature dependence of LDPE charge carriers.


  • Nanosecond PD Currents Under Needle-Plane Electrode With Different Electrode Radii Over Four Kinds of Polymer Films

    by Tatsuki Okamoto, Hiroaki Uehara, Yuta Makino, Toshihiro Takahashi

    Partial discharge (PD) degradation in high-voltage and/or high-field equipment is a major hazard that can result in equipment breakdown. Despite extensive research, PDs remain challenging to understand owing to their strong dependence on experimental conditions. Fast-PD waveforms have garnered significant interest owing to recent advancements in high-speed oscilloscopes, which has facilitated the measurement of PD current shapes and the direct analysis of nanosecond-order waveforms. PD currents typically flow in 10–20 ns and PD measurement circuit length must be sufficiently short to get correct PD waveforms. The total length of our PD current-flow circuit is made to be less than 15 cm to get correct waveforms. The electrode consists of a simple needle-plane electrode with small discharge gaps of 0–150 μm. The needle diameter is 1 mm with tip radii of 30 μm and 300 μm. An a.c. peak voltage of 2000 V at 50–1000 Hz are applied to polyimide, polyethylene terephthalate, polyethylene naphthalate, and polycarbonate films. The PD current waveforms exhibit approximately 5 ns peak time for both positive and negative pulses and the pulse width at half height of the peak value are 5–15 ns. Those times vary depending on the film material, discharge gap length and needle tip radius. The applied a.c. voltage frequency dependence of these times are small over the applied voltage frequencies. Moreover, nuclear magnetic resonance analyses suggest that the current wave form differences may occur with the dipole movement affects the trapped charge movements.


  • Nanosecond Current Waveforms With Small Discharge Gaps in Needle-Plane Electrode Over Three Kinds of Polymer Film

    by Tatsuki Okamoto, Hiroaki Uehara

    The nanosecond partial discharge (PD) currents have become increasingly important with the recent development of large power modules used in automobile drive mechanisms and other high-temperature equipment. Those modules are sometimes operated at frequencies higher than normal power frequencies, making it crucial to analyze the PD characteristics at these elevated frequencies. Measuring PD characteristics with a small gap, less than $100~\mu $ m, has also become essential due to system compactization. PD currents typically flow in a few tens of nanoseconds; hence, the wire length of the current measurement circuit should be sufficiently short. The electrode system employed in this study consists of a simple needle-plane electrode with small discharge gaps of 0, 12.5, 25, 50, 75, 100, and $150~\mu $ m. The needle diameter is 1 mm with a tip radius of $300~\mu $ m. The total length of the PD current-flow circuit is set to be less than approximately 150 mm. We measure nanosecond PD pulse current waveforms using a digital oscilloscope with an ac peak voltage of 2000 V at 50–1000 Hz. PD current forms were observed over polyimide (PI), polyethylene terephthalate (PET), and polyethylene naphthalate (PEN) films, widely used as insulating films. The PD current waveforms over PI, PET, and PEN films exhibited approximately 5 ns peak time for both positive and negative pulses, with a pulsewidth time at half height of the peak value ranging from about 5–15 ns. These times vary depending on the material kind and discharge gap length. The frequency dependence of those times showed little change over applied voltage frequencies. Moreover, new time-domain NMR analyses correlate the current waveform differences with the dipole movement affected by the trapped charges.


  • Open Access

    Circuit Models of Q(t) Data and Analyses of Saturation Time Dependency on Delay Parameters

    by Ryota Kitani, Shinya Iwata, Tomoka Tsuya, Hiroaki Uehara, Tatsuki Okamoto, Tatsuo Takada

    In recent years, there has been a considerable increase in the use of DC power equipment in the industry, making it crucial for insulation materials to withstand high DC electric fields. The current integration method (Q(t) measurement) is one of the most useful and effective methods to measure the time dependency of charges. However, the mathematical/physical model of Q(t) measurement is not advanced because obtained data are not completely analyzed, particularly the methods in which delay parameters affect the charge saturation time of insulators. In this study, we analyze the delay property of Q(t) data by solving differential equations with some approximations. In addition, sample sheets of polyimide and polyethylene terephthalate are tested for experimental purposes. The results indicate that circuit properties can be estimated from the analysis of experimental Q(t) data based on the assumption of a circuit model. The proposed analysis method can be used for further discussions regarding the analytical estimation of timing of charge saturation, and the relationship between circuit models and the space charges phenomenon.


  • Charge Accumulation Dependence on Electric Field, Temperature, and Voltage Application Time in Polymeric Insulating Materials by Current-Integrated Charge Method

    by Hiroaki Uehara, Shinya Iwata, Ryota Kitani, Tatsuki Okamoto, Tatsuo Takada

    The current-integrated charge (Q(t)) method used in this study can measure all fast-moving carrier charges and accumulated charges, which are shallow and deep trapped charges, respectively. The pulsed electro-acoustic (PEA) method is an excellent method for observing the distribution of accumulated charges; however, it is difficult to measure fast-moving carrier charges using the PEA method. Currently, space charge measurement data on a wide range of electric field, temperature, and voltage application time are required. Therefore, this study aims to provide the Q(t) data of charge accumulation characteristics by examining six types of polymeric insulating materials: low-density polyethylene (LDPE), cross-linked polyethylene (XLPE), polyethylene terephthalate (PET), polyimide (PI), polycarbonate (PC), and polyethylene naphthalate (PEN). The space charge accumulation is measured using the Q(t) method. The Q(t) measurement results are obtained over a wide range of electric field (1-100 kV/mm), temperature (20-80 °C), and voltage application time (0-5 h). The results show that the space charge accumulation characteristics (Q(t) data) of the six types of polymeric insulating materials are significantly dependent on these three factors. We believe the Q(t) method used in this study can contribute to further understanding of the charge accumulation properties of DC polymeric insulating materials.