ASAlexander Sun

Alexander Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Sun has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Density Redox Amplified Coulostatic Discharge-Based Biosensor Array

    by Alexander C. Sun, Enrique Alvarez-Fontecilla, A. G. Venkatesh, Eliah Aronoff-Spencer, Drew A. Hall

    High-density biosensor arrays are essential for many cutting-edge biomedical applications including point-of-care vaccination screening to detect multiple highly contagious diseases. Typical electrochemical biosensing techniques are based on the measurement of sub-pA currents for micrometer-sized sensors requiring highly sensitive readout circuits. Such circuits are often too complex to scale down for high-density arrays. In this paper, a high-density 4,096-pixel electrochemical biosensor array in 180-nm CMOS is presented. It uses a coulostatic discharge sensing technique and interdigitated electrode (IDE) geometry to reduce both the complexity and size of the readout circuitry. Each biopixel contains an interdigitated microelectrode with a 13-aA low-leakage readout circuit directly underneath. Compared to standard planar electrodes, the implemented IDEs achieve a maximum amplification factor of 10.5× from redox cycling. The array's sensor density is comparable to state-ofthe-art arrays, all without augmenting the sensors with complex post-processing. The detection of anti-Rubella and anti-Mumps antibodies in human serum is demonstrated.


  • A 64×64 high-density redox amplified coulostatic discharge-based biosensor array in 180nm CMOS

    by Alexander Sun, Enrique Alvarez-Fontecilla, A. G. Venkatesh, Eliah Aronoff-Spencer, Drew A. Hall

    This paper describes the design of a high-density 4,096-pixel electrochemical biosensor array in 180nm CMOS for biomedical applications that require multiple analyte detection from small (5μL) samples. Each pixel of the array contains an exposed 45×45μm 2 interdigitated micro-electrode surrounded by a ~9pL nanowell fabricated using only a standard CMOS process along with a simple electroless gold plating procedure without the need for further post processing. Directly underneath each transducer is a complete ultra-low-leakage (sub-fA) readout circuitry, which leverages the Coulostatic Discharge sensing technique and interdigitated electrode (IDE) geometry to minimize both the complexity and overall size of the array. By evaluating IDE designs with different feature sizes (2-5μm), an average maximum amplification factor of 10.5x was achieved using redox cycling coupled with the higher collection efficiency of trenches formed from opening the passivation. The array's sensor density is comparable to or better than state-of-the-art sensor arrays, all without augmenting the sensors with additional materials or structures. Using the array, detection of anti-Rubella is demonstrated as progress towards a complete vaccination panel.


  • Integrated biosensor for simultaneous detection by surface plasmon resonance and Faradaic electrochemical impedance spectroscopy

    by Brandon Hong, Alexander Sun, Lin Pang, A.G. Venkatesh, Drew Hall, Yeshaiahu Fainman

    We present an integrated label-free biosensor based on surface plasmon resonance and Faradaic electrochemical impedance spectroscopy sensing modalities, for simultaneous and independent detection of biological analytes. We report non-interfering dual detection of neutravidin in 10nM concentration.