Alexander Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander Sun has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Drew A. Hall
University of California, San Diego
3 shared publications A. G. Venkatesh
Electrical and Computer Engineering Department, University of California at San Diego, San Diego, CA, USA
2 shared publications- Enrique Alvarez-Fontecilla
Analog Devices Inc., Santiago, Chile
2 shared publications A.G. Venkatesh
University of California, San Diego, United States
1 shared publication- Brandon Hong
Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92023 USA
1 shared publication Eliah Aronoff-Spencer
School of Medicine, University of California at San Diego, San Diego, CA, USA
1 shared publication
Latest Publications
- 27 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (7) , 2054-2064
High-Density Redox Amplified Coulostatic Discharge-Based Biosensor Array
High-density biosensor arrays are essential for many cutting-edge biomedical applications including point-of-care vaccination screening to detect multiple highly contagious diseases. Typical electrochemical biosensing techniques are based on the measurement of sub-pA currents for micrometer-sized sensors requiring highly sensitive readout circuits. Such circuits are often too complex to scale down for high-density arrays. In this paper, a high-density 4,096-pixel electrochemical biosensor array in 180-nm CMOS is presented. It uses a coulostatic discharge sensing technique and interdigitated electrode (IDE) geometry to reduce both the complexity and size of the readout circuitry. Each biopixel contains an interdigitated microelectrode with a 13-aA low-leakage readout circuit directly underneath. Compared to standard planar electrodes, the implemented IDEs achieve a maximum amplification factor of 10.5× from redox cycling. The array's sensor density is comparable to state-ofthe-art arrays, all without augmenting the sensors with complex post-processing. The detection of anti-Rubella and anti-Mumps antibodies in human serum is demonstrated.
- 27 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (7) , 2054-2064
High-Density Redox Amplified Coulostatic Discharge-Based Biosensor Array
High-density biosensor arrays are essential for many cutting-edge biomedical applications including point-of-care vaccination screening to detect multiple highly contagious diseases. Typical electrochemical biosensing techniques are based on the measurement of sub-pA currents for micrometer-sized sensors requiring highly sensitive readout circuits. Such circuits are often too complex to scale down for high-density arrays. In this paper, a high-density 4,096-pixel electrochemical biosensor array in 180-nm CMOS is presented. It uses a coulostatic discharge sensing technique and interdigitated electrode (IDE) geometry to reduce both the complexity and size of the readout circuitry. Each biopixel contains an interdigitated microelectrode with a 13-aA low-leakage readout circuit directly underneath. Compared to standard planar electrodes, the implemented IDEs achieve a maximum amplification factor of 10.5× from redox cycling. The array's sensor density is comparable to state-ofthe-art arrays, all without augmenting the sensors with complex post-processing. The detection of anti-Rubella and anti-Mumps antibodies in human serum is demonstrated.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 368-371
A 64×64 high-density redox amplified coulostatic discharge-based biosensor array in 180nm CMOS
This paper describes the design of a high-density 4,096-pixel electrochemical biosensor array in 180nm CMOS for biomedical applications that require multiple analyte detection from small (5μL) samples. Each pixel of the array contains an exposed 45×45μm 2 interdigitated micro-electrode surrounded by a ~9pL nanowell fabricated using only a standard CMOS process along with a simple electroless gold plating procedure without the need for further post processing. Directly underneath each transducer is a complete ultra-low-leakage (sub-fA) readout circuitry, which leverages the Coulostatic Discharge sensing technique and interdigitated electrode (IDE) geometry to minimize both the complexity and overall size of the array. By evaluating IDE designs with different feature sizes (2-5μm), an average maximum amplification factor of 10.5x was achieved using redox cycling coupled with the higher collection efficiency of trenches formed from opening the passivation. The array's sensor density is comparable to or better than state-of-the-art sensor arrays, all without augmenting the sensors with additional materials or structures. Using the array, detection of anti-Rubella is demonstrated as progress towards a complete vaccination panel.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 368-371
A 64×64 high-density redox amplified coulostatic discharge-based biosensor array in 180nm CMOS
This paper describes the design of a high-density 4,096-pixel electrochemical biosensor array in 180nm CMOS for biomedical applications that require multiple analyte detection from small (5μL) samples. Each pixel of the array contains an exposed 45×45μm 2 interdigitated micro-electrode surrounded by a ~9pL nanowell fabricated using only a standard CMOS process along with a simple electroless gold plating procedure without the need for further post processing. Directly underneath each transducer is a complete ultra-low-leakage (sub-fA) readout circuitry, which leverages the Coulostatic Discharge sensing technique and interdigitated electrode (IDE) geometry to minimize both the complexity and overall size of the array. By evaluating IDE designs with different feature sizes (2-5μm), an average maximum amplification factor of 10.5x was achieved using redox cycling coupled with the higher collection efficiency of trenches formed from opening the passivation. The array's sensor density is comparable to or better than state-of-the-art sensor arrays, all without augmenting the sensors with additional materials or structures. Using the array, detection of anti-Rubella is demonstrated as progress towards a complete vaccination panel.
- 1 January 2016
- Published by Optica Publishing Group
- p. JW2A.113
Integrated biosensor for simultaneous detection by surface plasmon resonance and Faradaic electrochemical impedance spectroscopy
We present an integrated label-free biosensor based on surface plasmon resonance and Faradaic electrochemical impedance spectroscopy sensing modalities, for simultaneous and independent detection of biological analytes. We report non-interfering dual detection of neutravidin in 10nM concentration.
- 1 January 2016
- Published by Optica Publishing Group
- p. JW2A.113
Integrated biosensor for simultaneous detection by surface plasmon resonance and Faradaic electrochemical impedance spectroscopy
We present an integrated label-free biosensor based on surface plasmon resonance and Faradaic electrochemical impedance spectroscopy sensing modalities, for simultaneous and independent detection of biological analytes. We report non-interfering dual detection of neutravidin in 10nM concentration.