Ali Onder Biliroglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ali Onder Biliroglu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Omer Oralkan
North Carolina State University
10 shared publications - Feysel Yalcin Yamaner
North Carolina State University
9 shared publications - Oluwafemi Joel Adelegan
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
8 shared publications - Muhammetgeldi Annayev
North Carolina State University
4 shared publications - Jeanne Sanders
Department of Biomedical Engineering University of Michigan Ann Arbor Ann Arbor Michigan USA
3 shared publications - Tamzid Ibn Minhaj
North Carolina State University
3 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
Fabrication of an 8-Ring Annular Array from 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array Elements Using a Metal Redistribution Layer
The emergence of capacitive micromachined ultrasonic transducers (CMUTs) has enabled the possibility of different applications because of the inherent advantages associated with this technology. One of the notable advantages of this technology is the flexibility to implement complex transducer geometries with the established silicon microfabrication techniques. With this capability, application-specific CMUTs can be implemented, and with the possibility of CMUT integration with supporting electronics, compact form-factor ultrasound systems can be developed. One approach to develop different CMUT array geometries is by fixed lithographic definition. This study presents another approach for implementing different CMUT geometries on a 2D CMUT array canvas with the use of an additional metal layer as needed. This approach further simplifies the implementation of different complex CMUT geometries with a short turnaround time. To demonstrate this approach using a sacrificial release-based fabrication approach, an 8-ring concentric annular CMUT array was fabricated on a borosilicate glass substrate by connecting a group of elements on a 2D CMUT array canvas. The fabricated rings show an average resonant frequency of 4.8 MHz in air. In immersion, the 8-ring annular array, 7.98 mm in diameter, shows a focused pressure of 2.78 MPa peak-to-peak in oil at an optimum frequency of 3.46 MHz, and this pressure was measured at 8 mm from the array surface (F#1).
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. PP, 1
Fabrication of an 8-Ring Annular Array from 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array Elements Using a Metal Redistribution Layer
The emergence of capacitive micromachined ultrasonic transducers (CMUTs) has enabled the possibility of different applications because of the inherent advantages associated with this technology. One of the notable advantages of this technology is the flexibility to implement complex transducer geometries with the established silicon microfabrication techniques. With this capability, application-specific CMUTs can be implemented, and with the possibility of CMUT integration with supporting electronics, compact form-factor ultrasound systems can be developed. One approach to develop different CMUT array geometries is by fixed lithographic definition. This study presents another approach for implementing different CMUT geometries on a 2D CMUT array canvas with the use of an additional metal layer as needed. This approach further simplifies the implementation of different complex CMUT geometries with a short turnaround time. To demonstrate this approach using a sacrificial release-based fabrication approach, an 8-ring concentric annular CMUT array was fabricated on a borosilicate glass substrate by connecting a group of elements on a 2D CMUT array canvas. The fabricated rings show an average resonant frequency of 4.8 MHz in air. In immersion, the 8-ring annular array, 7.98 mm in diameter, shows a focused pressure of 2.78 MPa peak-to-peak in oil at an optimum frequency of 3.46 MHz, and this pressure was measured at 8 mm from the array surface (F#1).
- Open Access
Neurodegeneration Associated with Repeated High-Frequency Transcranial Focused Ultrasound
Transcranial Focused Ultrasound (tFUS) is a popular tool for non-invasive neuromodulation which prior testing paradigms have suggested is benign. However, emerging use cases such as clinical therapies and brain-machine interfaces will likely require repeated or long-duration exposures with novel combinations of stimulus parameters (e.g., frequency, focal volume), and the safety of these conditions has not yet been rigorously validated. Therefore, as an initial study we delivered 1.8 MHz tFUS stimulation to the cortex of 4 non-human primates in 4 sessions each of approximately 90 min over 2 weeks. Motor skills were measured daily with a food pellet picking task. Animals were euthanized and the brain sections were processed for histological markers of neurodegeneration (Fluoro-Jade C). While the animals did not show disruption on the behavioral task, there was clear evidence of neurodegeneration in regions associated with short, intermediate, and extended-duration stimulation, but not with unstimulated control tissues in deeper brain areas. Additional neurodegeneration was observed at locations distant from but functionally connected to stimulated regions, consistent with retrograde damage propagated from neuron processes. We discuss alternative causes for the neurodegeneration, and we recommend the use of additional animal studies to understand this phenomenon, especially for novel stimulation paradigms or parameters and applications where extended or repeated exposures are planned.
Open AccessNeurodegeneration Associated with Repeated High-Frequency Transcranial Focused Ultrasound
Transcranial Focused Ultrasound (tFUS) is a popular tool for non-invasive neuromodulation which prior testing paradigms have suggested is benign. However, emerging use cases such as clinical therapies and brain-machine interfaces will likely require repeated or long-duration exposures with novel combinations of stimulus parameters (e.g., frequency, focal volume), and the safety of these conditions has not yet been rigorously validated. Therefore, as an initial study we delivered 1.8 MHz tFUS stimulation to the cortex of 4 non-human primates in 4 sessions each of approximately 90 min over 2 weeks. Motor skills were measured daily with a food pellet picking task. Animals were euthanized and the brain sections were processed for histological markers of neurodegeneration (Fluoro-Jade C). While the animals did not show disruption on the behavioral task, there was clear evidence of neurodegeneration in regions associated with short, intermediate, and extended-duration stimulation, but not with unstimulated control tissues in deeper brain areas. Additional neurodegeneration was observed at locations distant from but functionally connected to stimulated regions, consistent with retrograde damage propagated from neuron processes. We discuss alternative causes for the neurodegeneration, and we recommend the use of additional animal studies to understand this phenomenon, especially for novel stimulation paradigms or parameters and applications where extended or repeated exposures are planned.
- Open Access
- 30 August 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1106
Design, Fabrication, and Characterization of Capacitive Micromachined Ultrasonic Transducers for Transcranial, Multifocus Neurostimulation
In a recent study using 3-D fullwave simulations, it was shown for a nonhuman primate model that a helmet-shaped 3D array of 128 transducer elements can be assembled for neurostimulation in an optimized configuration with the accommodation of an imaging aperture. Considering all acoustic losses, according to this study, for a nonhuman primate skull, the assembly of the proposed transducers was projected to produce sufficient focusing gain in two different focal positions at deep and shallow brain regions, thus providing sufficient acoustic intensity at these distinct focal points for neural stimulation. This array also has the ability to focus on multiple additional brain regions. In the work presented here, we designed and fabricated a single 15 mm diameter capacitive micromachined ultrasonic transducer (CMUT) element operating at 800 kHz central frequency with a 480 kHz 3 dB bandwidth, capable of producing a 190 kPa peak negative pressure (PNP) on the surface. The corresponding projected transcranial spatial peak pulse average intensity (ISPPA) was 28 Wcm−2, and the mechanical index (MI) value was 1.1 for an array of 128 of these elements.
- 30 August 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1106
Open AccessDesign, Fabrication, and Characterization of Capacitive Micromachined Ultrasonic Transducers for Transcranial, Multifocus Neurostimulation
In a recent study using 3-D fullwave simulations, it was shown for a nonhuman primate model that a helmet-shaped 3D array of 128 transducer elements can be assembled for neurostimulation in an optimized configuration with the accommodation of an imaging aperture. Considering all acoustic losses, according to this study, for a nonhuman primate skull, the assembly of the proposed transducers was projected to produce sufficient focusing gain in two different focal positions at deep and shallow brain regions, thus providing sufficient acoustic intensity at these distinct focal points for neural stimulation. This array also has the ability to focus on multiple additional brain regions. In the work presented here, we designed and fabricated a single 15 mm diameter capacitive micromachined ultrasonic transducer (CMUT) element operating at 800 kHz central frequency with a 480 kHz 3 dB bandwidth, capable of producing a 190 kPa peak negative pressure (PNP) on the surface. The corresponding projected transcranial spatial peak pulse average intensity (ISPPA) was 28 Wcm−2, and the mechanical index (MI) value was 1.1 for an array of 128 of these elements.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (5) , 586-595
Fabrication of 32×32 2 D CMUT Arrays on a Borosilicate Glass Substrate With Silicon- Through-Wafer Interconnects Using Non- Aligned and Aligned Anodic Bonding
2D arrays are crucial for developing compact and efficient 3D ultrasound systems. Capacitive micromachined ultrasonic transducer (CMUT) arrays, providing convenient integration with supporting electronics, are advantageous for implementing such systems. Fabricating 2D CMUT arrays and integrated circuits (ICs) separately and then combining them in the packaging stage provides flexibility in design and integration. The integrated system can be used for beam-steering and electronic focusing in 3D space. Previously, fabrication processes were reported for implementing 2D CMUT arrays on glass substrates with copper through-glass-via (Cu-TGV) interconnects using anodic bonding and silicon through-glass-via (Si-TGV) interconnects using a sacrificial-release process. Both approaches had challenges, such as voids in Cu-vias, microcracks in laser-drilled glass, mechanical stress in CVD nitride layers, and low fill factor due to fabrication limitations. These challenges can be overcome by combining Si-TGV interconnects with an anodic bonding process. We developed a Si-TGV wafer with a backside glass layer to make it compatible with anodic bonding. We designed and fabricated $32\times32$ 2D CMUT arrays with a single cell per element to increase the fill factor and to produce high pressure. We measured an output pressure as high as 4.75 MPa $_{\textbf{pp}}$ at 1.8 MHz by focusing the array at 8 mm (F $\#$ 1). Four arrays, tiled next to each other in a $2\times2$ grid, focusing at 15 mm produced up to 8.65 MPa $_{\textbf{pp}}$ pressure at 1.8 MHz. We achieved 99.9 % element yield measured in a single array. 2024-0078
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 33 (5) , 586-595
Fabrication of 32×32 2 D CMUT Arrays on a Borosilicate Glass Substrate With Silicon- Through-Wafer Interconnects Using Non- Aligned and Aligned Anodic Bonding
2D arrays are crucial for developing compact and efficient 3D ultrasound systems. Capacitive micromachined ultrasonic transducer (CMUT) arrays, providing convenient integration with supporting electronics, are advantageous for implementing such systems. Fabricating 2D CMUT arrays and integrated circuits (ICs) separately and then combining them in the packaging stage provides flexibility in design and integration. The integrated system can be used for beam-steering and electronic focusing in 3D space. Previously, fabrication processes were reported for implementing 2D CMUT arrays on glass substrates with copper through-glass-via (Cu-TGV) interconnects using anodic bonding and silicon through-glass-via (Si-TGV) interconnects using a sacrificial-release process. Both approaches had challenges, such as voids in Cu-vias, microcracks in laser-drilled glass, mechanical stress in CVD nitride layers, and low fill factor due to fabrication limitations. These challenges can be overcome by combining Si-TGV interconnects with an anodic bonding process. We developed a Si-TGV wafer with a backside glass layer to make it compatible with anodic bonding. We designed and fabricated $32\times32$ 2D CMUT arrays with a single cell per element to increase the fill factor and to produce high pressure. We measured an output pressure as high as 4.75 MPa $_{\textbf{pp}}$ at 1.8 MHz by focusing the array at 8 mm (F $\#$ 1). Four arrays, tiled next to each other in a $2\times2$ grid, focusing at 15 mm produced up to 8.65 MPa $_{\textbf{pp}}$ pressure at 1.8 MHz. We achieved 99.9 % element yield measured in a single array. 2024-0078
- 30 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (7) , 2318-2330
A Handheld Imaging Probe for Acoustic Angiography With an Ultrawideband Capacitive Micromachined Ultrasonic Transducer (CMUT) Array
This article presents an imaging probe with a 256-element ultrawideband (UWB) 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for acoustic angiography (AA). This array was fabricated on a borosilicate glass wafer with a reduced bottom electrode and an additional central plate mass to achieve the broad bandwidth. A custom 256-channel handheld probe was designed and implemented with integrated low-noise amplifiers and supporting power circuitry. This probe was used to characterize the UWB CMUT, which has a functional 3-dB frequency band from 3.5 to 23.5 MHz. A mechanical index (MI) of 0.33 was achieved at 3.5 MHz at a depth of 11 mm. These promising measurements are then combined to demonstrate AA. The use of alternate amplitude modulation (aAM) combined with a frequency analysis of the measured transmit signal demonstrates the suitability of the UWB CMUT for AA. This is achieved by measuring only a low level of unwanted high-frequency harmonics in both the transmit signal and the reconstructed image in the areas other than the contrast bubbles.
- 30 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (7) , 2318-2330
A Handheld Imaging Probe for Acoustic Angiography With an Ultrawideband Capacitive Micromachined Ultrasonic Transducer (CMUT) Array
This article presents an imaging probe with a 256-element ultrawideband (UWB) 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for acoustic angiography (AA). This array was fabricated on a borosilicate glass wafer with a reduced bottom electrode and an additional central plate mass to achieve the broad bandwidth. A custom 256-channel handheld probe was designed and implemented with integrated low-noise amplifiers and supporting power circuitry. This probe was used to characterize the UWB CMUT, which has a functional 3-dB frequency band from 3.5 to 23.5 MHz. A mechanical index (MI) of 0.33 was achieved at 3.5 MHz at a depth of 11 mm. These promising measurements are then combined to demonstrate AA. The use of alternate amplitude modulation (aAM) combined with a frequency analysis of the measured transmit signal demonstrates the suitability of the UWB CMUT for AA. This is achieved by measuring only a low level of unwanted high-frequency harmonics in both the transmit signal and the reconstructed image in the areas other than the contrast bubbles.
- Open Access
- 20 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (6) , 968-979
Fabrication of 32 × 32 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Arrays on a Borosilicate Glass Substrate With Silicon-Through-Wafer Interconnects Using Sacrificial Release Process
Close integration of transducer arrays with supporting electronic circuits is essential in achieving efficient and compact ultrasound systems. An integral part of hybrid integration of 2D CMUT array to CMOS electronics is the introduction of through-glass-via (TGV) interconnects in glass substrates as an integral part of the 2D CMUT array fabrication. Micro-cracks around via locations, via discontinuity, and poor coplanarity between the vias and glass substrate are some of the challenges with laser-drilled, paste-filled copper-through-glass-via (Cu-TGV) interconnects. This study provides a detailed fabrication process for making $32\times 32$ -element 2D CMUT arrays on a composite glass substrate incorporating silicon-through-glass vias (Si-TGV) as interconnects using sacrificial release approach. On one column of a fabricated 2D CMUT array, we measured a mean resonant frequency of 5.6 MHz in air and an average device capacitance of 1.5 pF. With the introduction of a buried top electrode in the device structure, we achieved a collapse voltage of 93 V, which is considerably lower than the collapse voltage measured in our previously demonstrated 2D CMUT arrays with top electrode on top of the nitride plate. The fabricated array is flip-chip bonded on a custom-designed driving integrated circuit to demonstrate the complete system operation. We measured a peak-to-peak pressure of 1.82 MPa at 3.4 MHz, and 5 mm from the array surface in a 0.33 mm focal spot size. [2021-0101]
- 20 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 30 (6) , 968-979
Open AccessFabrication of 32 × 32 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Arrays on a Borosilicate Glass Substrate With Silicon-Through-Wafer Interconnects Using Sacrificial Release Process
Close integration of transducer arrays with supporting electronic circuits is essential in achieving efficient and compact ultrasound systems. An integral part of hybrid integration of 2D CMUT array to CMOS electronics is the introduction of through-glass-via (TGV) interconnects in glass substrates as an integral part of the 2D CMUT array fabrication. Micro-cracks around via locations, via discontinuity, and poor coplanarity between the vias and glass substrate are some of the challenges with laser-drilled, paste-filled copper-through-glass-via (Cu-TGV) interconnects. This study provides a detailed fabrication process for making $32\times 32$ -element 2D CMUT arrays on a composite glass substrate incorporating silicon-through-glass vias (Si-TGV) as interconnects using sacrificial release approach. On one column of a fabricated 2D CMUT array, we measured a mean resonant frequency of 5.6 MHz in air and an average device capacitance of 1.5 pF. With the introduction of a buried top electrode in the device structure, we achieved a collapse voltage of 93 V, which is considerably lower than the collapse voltage measured in our previously demonstrated 2D CMUT arrays with top electrode on top of the nitride plate. The fabricated array is flip-chip bonded on a custom-designed driving integrated circuit to demonstrate the complete system operation. We measured a peak-to-peak pressure of 1.82 MPa at 3.4 MHz, and 5 mm from the array surface in a 0.33 mm focal spot size. [2021-0101]
- 16 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (4) , 705-718
A Wearable Ultrasonic Neurostimulator—Part II: A 2D CMUT Phased Array System With a Flip-Chip Bonded ASIC
A 2D ultrasonic array is the ultimate form of a focused ultrasonic system, which enables electronically focusing beams in a 3D space. A 2D array is also a versatile tool for various applications such as 3D imaging, high-intensity focused ultrasound, particle manipulation, and pattern generation. However, building a 2D system involves complicated technologies: fabricating a 2D transducer array, developing a pitch-matched ASIC, and interconnecting the transducer and the ASIC. Previously, we successfully demonstrated 2D capacitive micromachined ultrasonic transducer (CMUT) arrays using various fabrication technologies. In this paper, we present a 2D ultrasonic transmit phased array based on a 32 × 32 CMUT array flip-chip bonded to a pitch-matched pulser ASIC for ultrasonic neuromodulation. The ASIC consists of 32 × 32 unipolar high-voltage (HV) pulsers, each of which occupies an area of 250 $\mu$ m × 250 $\mu$ m. The phase of each pulser output is individually programmable with a resolution of $1/f_{\mathrm{C}}/16$ , where $f_{\mathrm{C}}$ is less than 10 MHz. This enables the fine granular control of a focus. The ASIC was fabricated in the TSMC 0.18- $\mu$ m HV BCD process within an area of 9.8 mm × 9.8 mm, followed by a wafer-level solder bumping process. After flip-chip bonding an ASIC and a CMUT array, we identified shorted elements in the CMUT array using the built-in test function in the ASIC, which took approximately 9 minutes to scan the entire 32 × 32 array. A compact-form-factor wireless neural stimulator system—only requiring a connected 15-V DC power supply—was also developed, integrating a power management unit, a clock generator, and a Bluetooth Low-Energy enabled microcontroller. The focusing and steering capability of the system in a 3D space is demonstrated, while achieving a spatial-peak pulse-average intensity ( $\mathrm{I_{SPPA}}$ ) of 12.4 and 33.1 W/ ${\rm cm^{2}}$ ; and a 3-dB focal volume of 0.2 and 0.05 ${\rm mm^{3}}$ —at a depth of 5 mm—at 2 and 3.4 MHz, respectively. We also characterized transmission of ultrasound through a mouse skull and compensated the phase distortion due to the skull by using the programmable phase-delay function in the ASIC, achieving 10% improvement in pressure and a tighter focus. Finally, we demonstrated a ultrasonic arbitrary pattern generation on a 5 mm × 5 mm plane at a depth of 5 mm.
- 16 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (4) , 705-718
A Wearable Ultrasonic Neurostimulator—Part II: A 2D CMUT Phased Array System With a Flip-Chip Bonded ASIC
A 2D ultrasonic array is the ultimate form of a focused ultrasonic system, which enables electronically focusing beams in a 3D space. A 2D array is also a versatile tool for various applications such as 3D imaging, high-intensity focused ultrasound, particle manipulation, and pattern generation. However, building a 2D system involves complicated technologies: fabricating a 2D transducer array, developing a pitch-matched ASIC, and interconnecting the transducer and the ASIC. Previously, we successfully demonstrated 2D capacitive micromachined ultrasonic transducer (CMUT) arrays using various fabrication technologies. In this paper, we present a 2D ultrasonic transmit phased array based on a 32 × 32 CMUT array flip-chip bonded to a pitch-matched pulser ASIC for ultrasonic neuromodulation. The ASIC consists of 32 × 32 unipolar high-voltage (HV) pulsers, each of which occupies an area of 250 $\mu$ m × 250 $\mu$ m. The phase of each pulser output is individually programmable with a resolution of $1/f_{\mathrm{C}}/16$ , where $f_{\mathrm{C}}$ is less than 10 MHz. This enables the fine granular control of a focus. The ASIC was fabricated in the TSMC 0.18- $\mu$ m HV BCD process within an area of 9.8 mm × 9.8 mm, followed by a wafer-level solder bumping process. After flip-chip bonding an ASIC and a CMUT array, we identified shorted elements in the CMUT array using the built-in test function in the ASIC, which took approximately 9 minutes to scan the entire 32 × 32 array. A compact-form-factor wireless neural stimulator system—only requiring a connected 15-V DC power supply—was also developed, integrating a power management unit, a clock generator, and a Bluetooth Low-Energy enabled microcontroller. The focusing and steering capability of the system in a 3D space is demonstrated, while achieving a spatial-peak pulse-average intensity ( $\mathrm{I_{SPPA}}$ ) of 12.4 and 33.1 W/ ${\rm cm^{2}}$ ; and a 3-dB focal volume of 0.2 and 0.05 ${\rm mm^{3}}$ —at a depth of 5 mm—at 2 and 3.4 MHz, respectively. We also characterized transmission of ultrasound through a mouse skull and compensated the phase distortion due to the skull by using the programmable phase-delay function in the ASIC, achieving 10% improvement in pressure and a tighter focus. Finally, we demonstrated a ultrasonic arbitrary pattern generation on a 5 mm × 5 mm plane at a depth of 5 mm.
- 1 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 19684-19696
A Low-Power Wearable E-Nose System Based on a Capacitive Micromachined Ultrasonic Transducer (CMUT) Array for Indoor VOC Monitoring
Volatile organic compounds (VOCs) are pervasive in the environment and their real-time continuous monitoring can facilitate better understanding of their effects on human health by combining environmental factors with physiological conditions. The scope of wearable sensors for detection of VOCs is evident as the accuracy of the sensor prediction depends on its proximity to the VOC source along with the sensitivity and selectivity of the sensor itself. In this paper, we present a low-power wearable e-nose system based on a capacitive micromachined ultrasonic transducer (CMUT) array. CMUTs offer inherent benefits of excellent mass resolution, easy array fabrication, and integration with electronics, which make them an appropriate choice as a transducer element for gravimetric e-nose systems. A 5-channel CMUT sensor array was chemically functionalized and used for the detection of four volatiles, ethanol, toluene, p-xylene, and styrene. All the channels of the sensor array achieved a resolution below 10 ppm within 0.2–3% of OSHA-PEL time-weighted average (TWA) for each volatile. For each test cycle, the maximum frequency shift, the rate of adsorption, and the rate of desorption were extracted as features. Linear discriminant analysis (LDA) was applied to visualize the discrimination performance of the sensor array. The system performance was characterized using an automated testing system. The presented sensor system can be used for identification of volatiles with suitable pattern-recognition techniques.
- 1 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 19684-19696
A Low-Power Wearable E-Nose System Based on a Capacitive Micromachined Ultrasonic Transducer (CMUT) Array for Indoor VOC Monitoring
Volatile organic compounds (VOCs) are pervasive in the environment and their real-time continuous monitoring can facilitate better understanding of their effects on human health by combining environmental factors with physiological conditions. The scope of wearable sensors for detection of VOCs is evident as the accuracy of the sensor prediction depends on its proximity to the VOC source along with the sensitivity and selectivity of the sensor itself. In this paper, we present a low-power wearable e-nose system based on a capacitive micromachined ultrasonic transducer (CMUT) array. CMUTs offer inherent benefits of excellent mass resolution, easy array fabrication, and integration with electronics, which make them an appropriate choice as a transducer element for gravimetric e-nose systems. A 5-channel CMUT sensor array was chemically functionalized and used for the detection of four volatiles, ethanol, toluene, p-xylene, and styrene. All the channels of the sensor array achieved a resolution below 10 ppm within 0.2–3% of OSHA-PEL time-weighted average (TWA) for each volatile. For each test cycle, the maximum frequency shift, the rate of adsorption, and the rate of desorption were extracted as features. Linear discriminant analysis (LDA) was applied to visualize the discrimination performance of the sensor array. The system performance was characterized using an automated testing system. The presented sensor system can be used for identification of volatiles with suitable pattern-recognition techniques.
- 25 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (3) , 767-776
A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate
This article presents a row-column (RC) capacitive micromachined ultrasonic transducer (CMUT) array fabricated using anodic bonding on a borosilicate glass substrate. This is shown to reduce the bottom electrode-to-substrate capacitive coupling. This subsequently improves the relative response of the elements when top or bottom electrodes are used as the “signal” (active) electrode. This results in a more uniform performance for the two cases. Measured capacitance and resonant frequency, pulse-echo signal amplitude, and frequency response are presented to support this. Biasing configurations with varying ac and dc arrangements are applied and subsequently explored. Setting the net dc bias voltage across an off element to zero is found to be most effective to minimize spurious transmission. To achieve this, a custom switching circuit was designed and implemented. This circuit was also used to obtain orthogonal B-mode cross-sectional images of a rotationally asymmetric target.
- 25 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (3) , 767-776
A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate
This article presents a row-column (RC) capacitive micromachined ultrasonic transducer (CMUT) array fabricated using anodic bonding on a borosilicate glass substrate. This is shown to reduce the bottom electrode-to-substrate capacitive coupling. This subsequently improves the relative response of the elements when top or bottom electrodes are used as the “signal” (active) electrode. This results in a more uniform performance for the two cases. Measured capacitance and resonant frequency, pulse-echo signal amplitude, and frequency response are presented to support this. Biasing configurations with varying ac and dc arrangements are applied and subsequently explored. Setting the net dc bias voltage across an off element to zero is found to be most effective to minimize spurious transmission. To achieve this, a custom switching circuit was designed and implemented. This circuit was also used to obtain orthogonal B-mode cross-sectional images of a rotationally asymmetric target.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (11) , 2291-2302
An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography
This study demonstrates, in detail, the potential of using capacitive micromachined ultrasonic transducers (CMUTs) for acoustic angiography of the microvasculature. It is known that when ultrasound contrast agents (microbubbles) are excited with moderate acoustic pressure around their resonance (2-4 MHz), they produce higher order harmonics (greater than third harmonic) due to their nonlinear behavior. To date, the fundamental challenge has been the availability of a transducer that can generate the transmit signals to excite the microbubbles at low frequencies and, in the same cycle, confocally detect harmonics in the higher frequencies. We present a novel device structure and dual-mode operation of a CMUT that operates with a center frequency of 4.3 MHz and 150% bandwidth in the conventional mode for transmitting and a center frequency of 9.8 MHz and a 125.5% bandwidth in collapse mode for receiving. Output pressure of 1.7 MPapp is achieved on the surface of a single unfocused transducer. The mechanical index at the transducer surface is 0.56. FEM simulations are performed first to show the functionality of the proposed device, and then, the device fabrication is described in detail. Finally, we experimentally demonstrate the ability to detect the microbubble signals with good contrast, and the background reflection is adequately suppressed, indicating the feasibility of the presented approach for acoustic angiography.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (11) , 2291-2302
An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography
This study demonstrates, in detail, the potential of using capacitive micromachined ultrasonic transducers (CMUTs) for acoustic angiography of the microvasculature. It is known that when ultrasound contrast agents (microbubbles) are excited with moderate acoustic pressure around their resonance (2-4 MHz), they produce higher order harmonics (greater than third harmonic) due to their nonlinear behavior. To date, the fundamental challenge has been the availability of a transducer that can generate the transmit signals to excite the microbubbles at low frequencies and, in the same cycle, confocally detect harmonics in the higher frequencies. We present a novel device structure and dual-mode operation of a CMUT that operates with a center frequency of 4.3 MHz and 150% bandwidth in the conventional mode for transmitting and a center frequency of 9.8 MHz and a 125.5% bandwidth in collapse mode for receiving. Output pressure of 1.7 MPapp is achieved on the surface of a single unfocused transducer. The mechanical index at the transducer surface is 0.56. FEM simulations are performed first to show the functionality of the proposed device, and then, the device fabrication is described in detail. Finally, we experimentally demonstrate the ability to detect the microbubble signals with good contrast, and the background reflection is adequately suppressed, indicating the feasibility of the presented approach for acoustic angiography.