Dongming Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dongming Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yueming Gao
College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
4 shared publications - Linnan Huang
Fuzhou University, Fuzhou, China
2 shared publications - Mang I. Vai
University of Macau
2 shared publications - Mario Cifrek
University of Zagreb Faculty of Electrical Engineering and Computing, 10000 Zagreb, Croatia
2 shared publications - Min Du
College of Physics and Information Engineering, Fuzhou University, Fuzhou, China
2 shared publications - Sio Hang Pun
State Key Laboratory of Analog and Mixed Signal VLSI, Institute of Microelectronics University of Macau Macau China
2 shared publications
Latest Publications
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Dynamic High-Fidelity Equivalent Circuit Phantom for Intracardiac Communication in Pacemaker Indications
Conductive intracardiac communication (CIC) is an essential approach for achieving multichamber pacing in leadless pacemakers (LCPs), significantly enhancing the therapeutic outcomes for conditions, such as bradycardia. However, the characteristics of the intracardiac channel are profoundly affected by the heart’s rhythmic contractions. Accurately understanding the dynamic transmission mechanisms and channel parameters under various cardiac pathological states is crucial for enhancing the multichamber pacing functionality of LCPs. In this article, the relationship between cardiac chamber volume and channel impedance is mapped based on the electrocardiogram (ECG) data. This mapping enables precise, real-time adjustments to variable impedance, simulating the impedance changes occurring with each heartbeat. Through this approach, a time-frequency equivalent circuit phantom is proposed to accurately simulate channel characteristics for various pacemaker indications (PIs). Utilizing a quasi-dual-pump structural analogy to the heart, we designed a dynamic experimental measurement platform capable of simulating the cardiac beating process under various PIs, which is employed to validate the accuracy of the circuit phantom. The results demonstrate that the correlation coefficients in the frequency and time domains are greater than 0.9432 and 0.9150, respectively, with a time-domain consistency coefficient of less than 3.25. Through cross validation in both frequency and time domains, the circuit effectively simulates the channel characteristics of normal and PI hearts. The empirical formula established based on the time-domain measurement results can be utilized for the rapid estimation of the right atrium (RA)–right ventricle (RV) channel characteristics. The proposed phantom offers a highly accurate and reproducible experimental method for the design of intracardiac communication transceivers, advancing the development and validation of leadless multichamber pacemaker systems.
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Dynamic High-Fidelity Equivalent Circuit Phantom for Intracardiac Communication in Pacemaker Indications
Conductive intracardiac communication (CIC) is an essential approach for achieving multichamber pacing in leadless pacemakers (LCPs), significantly enhancing the therapeutic outcomes for conditions, such as bradycardia. However, the characteristics of the intracardiac channel are profoundly affected by the heart’s rhythmic contractions. Accurately understanding the dynamic transmission mechanisms and channel parameters under various cardiac pathological states is crucial for enhancing the multichamber pacing functionality of LCPs. In this article, the relationship between cardiac chamber volume and channel impedance is mapped based on the electrocardiogram (ECG) data. This mapping enables precise, real-time adjustments to variable impedance, simulating the impedance changes occurring with each heartbeat. Through this approach, a time-frequency equivalent circuit phantom is proposed to accurately simulate channel characteristics for various pacemaker indications (PIs). Utilizing a quasi-dual-pump structural analogy to the heart, we designed a dynamic experimental measurement platform capable of simulating the cardiac beating process under various PIs, which is employed to validate the accuracy of the circuit phantom. The results demonstrate that the correlation coefficients in the frequency and time domains are greater than 0.9432 and 0.9150, respectively, with a time-domain consistency coefficient of less than 3.25. Through cross validation in both frequency and time domains, the circuit effectively simulates the channel characteristics of normal and PI hearts. The empirical formula established based on the time-domain measurement results can be utilized for the rapid estimation of the right atrium (RA)–right ventricle (RV) channel characteristics. The proposed phantom offers a highly accurate and reproducible experimental method for the design of intracardiac communication transceivers, advancing the development and validation of leadless multichamber pacemaker systems.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
An Analog Front-End with Automatic Gain Control for Galvanic-Coupled Human Body Communication
The channel loss of galvanic-coupled human body communication (GC-HBC) is greatly affected by human body activities or individual differences, which will cause large changes in the amplitude of the input signal received by the receiver. This requires the analog front-end to have the ability to adaptively adjust the circuit gain to ensure stable output of the amplified signal. In this regard, this paper proposes an analog front-end with automatic gain control for GC-HBC. This circuit uses a differential preamplifier circuit with high input impedance and a rear-stage automatic gain control circuit that uses voltage feedback to control gain. While achieving amplification of weak signals, it also meets the requirements for stable signal output. The measurement results show that it has an input impedance of $> \mathbf{100}\mathbf{M}\mathbf{\Omega}$ , a maximum gain of 74dB, and a sensitivity of - 76dBm, effectively meeting the needs for capturing and amplifying weak signals. The loop stabilization time is $156\mu\mathrm{s}$ , and the input dynamic range is 34dB, which can ensure stable output of the amplified signal amplitude when the input signal amplitude changes.- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
An Analog Front-End with Automatic Gain Control for Galvanic-Coupled Human Body Communication
The channel loss of galvanic-coupled human body communication (GC-HBC) is greatly affected by human body activities or individual differences, which will cause large changes in the amplitude of the input signal received by the receiver. This requires the analog front-end to have the ability to adaptively adjust the circuit gain to ensure stable output of the amplified signal. In this regard, this paper proposes an analog front-end with automatic gain control for GC-HBC. This circuit uses a differential preamplifier circuit with high input impedance and a rear-stage automatic gain control circuit that uses voltage feedback to control gain. While achieving amplification of weak signals, it also meets the requirements for stable signal output. The measurement results show that it has an input impedance of $> \mathbf{100}\mathbf{M}\mathbf{\Omega}$ , a maximum gain of 74dB, and a sensitivity of - 76dBm, effectively meeting the needs for capturing and amplifying weak signals. The loop stabilization time is $156\mu\mathrm{s}$ , and the input dynamic range is 34dB, which can ensure stable output of the amplified signal amplitude when the input signal amplitude changes.- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (4) , 313-321
A Leg Phantom Model Based on the Visible Human Data for Intra-Body Communication
Intra-body communication (IBC) is an alternative method for communication of devices in body area networks. The existing research is mainly focused on on-body (OB) channel modeling, transceiver design, and in vivo experiments. However, the difficulty arises in carrying out long-term in vivo experiments for investigating the human channel characteristics in OB or in-body (IB) IBC channels, since the repeatability of in vivo experiments shows inconsistency. In this paper, a multi-layer leg model with realistic shape was designed based on visible human data (VHD) images. Then, novel mixtures with the approximate conductivities of leg tissues were designed and used to fabricate leg phantoms, via several pairs of 3D-printed molds. Finally, the efficiency of the leg phantoms was validated by in vivo experiments through the high similarity of voltage gain versus distance characteristic of the OB channel. Both conditions featured the same trend, that is, they decreased first and then stabilized. The leg phantom was adopted to explore the channel characteristics of the IB channel. The results indicate that the voltage gain versus distance curve of the OB to IB channel was nearly reciprocal. In summary, the VHD-based leg phantom provides a reusable experiment platform for the IBC research, especially for the case of implantable channels.
- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 5 (4) , 313-321
A Leg Phantom Model Based on the Visible Human Data for Intra-Body Communication
Intra-body communication (IBC) is an alternative method for communication of devices in body area networks. The existing research is mainly focused on on-body (OB) channel modeling, transceiver design, and in vivo experiments. However, the difficulty arises in carrying out long-term in vivo experiments for investigating the human channel characteristics in OB or in-body (IB) IBC channels, since the repeatability of in vivo experiments shows inconsistency. In this paper, a multi-layer leg model with realistic shape was designed based on visible human data (VHD) images. Then, novel mixtures with the approximate conductivities of leg tissues were designed and used to fabricate leg phantoms, via several pairs of 3D-printed molds. Finally, the efficiency of the leg phantoms was validated by in vivo experiments through the high similarity of voltage gain versus distance characteristic of the OB channel. Both conditions featured the same trend, that is, they decreased first and then stabilized. The leg phantom was adopted to explore the channel characteristics of the IB channel. The results indicate that the voltage gain versus distance curve of the OB to IB channel was nearly reciprocal. In summary, the VHD-based leg phantom provides a reusable experiment platform for the IBC research, especially for the case of implantable channels.
- Open Access
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 172233-172243
Analysis of Electrical Impedance Myography Electrodes Configuration for Local Muscle Fatigue Evaluation Based on Finite Element Method
Local muscle fatigue (LMF) is a common physiological phenomenon that occurs in daily exercise training and medical rehabilitation. Without timely treatment it can easily lead to muscle spasm, ligament rupture, and even stress fractures. Electrical impedance myography (EIM) is a noninvasive bioelectrical impedance technique suitable for the wearable LMF monitoring anytime and anywhere. In this paper, a novel EIM electrode configuration was proposed by establishing a four-layer simulation model of the human upper arm in FEM software. Sensitivity parameters were introduced to optimize muscle selectivity. The effect of fat thickness on impedance change rate was explored to reduce the influence of individual fat differences on EIM results. Dynamic and static contraction experiments of muscle fatigue were performed on the biceps brachii muscles of 10 volunteers to verify the effectiveness and feasibility of the proposed electrode configuration. The proposed electrode configuration reduced the measurement area by 25%, whereas the impedance amplitude and sensitivity remained the same. The influence of individual fat differences on EIM results was significantly reduced. When the fat thickness increased from 6 mm to 18 mm, the impedance change decreased by 31.78% compared with the traditional electrode configuration. When the muscles were extremely exhausted, the decrease in resistance varied around 10 Ω and within 10-1 order of magnitude in different volunteers. In a word, the proposed electrode configuration effectively evaluated the degree of LMF, providing more feasibility for the design of wearable devices.
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 172233-172243
Open AccessAnalysis of Electrical Impedance Myography Electrodes Configuration for Local Muscle Fatigue Evaluation Based on Finite Element Method
Local muscle fatigue (LMF) is a common physiological phenomenon that occurs in daily exercise training and medical rehabilitation. Without timely treatment it can easily lead to muscle spasm, ligament rupture, and even stress fractures. Electrical impedance myography (EIM) is a noninvasive bioelectrical impedance technique suitable for the wearable LMF monitoring anytime and anywhere. In this paper, a novel EIM electrode configuration was proposed by establishing a four-layer simulation model of the human upper arm in FEM software. Sensitivity parameters were introduced to optimize muscle selectivity. The effect of fat thickness on impedance change rate was explored to reduce the influence of individual fat differences on EIM results. Dynamic and static contraction experiments of muscle fatigue were performed on the biceps brachii muscles of 10 volunteers to verify the effectiveness and feasibility of the proposed electrode configuration. The proposed electrode configuration reduced the measurement area by 25%, whereas the impedance amplitude and sensitivity remained the same. The influence of individual fat differences on EIM results was significantly reduced. When the fat thickness increased from 6 mm to 18 mm, the impedance change decreased by 31.78% compared with the traditional electrode configuration. When the muscles were extremely exhausted, the decrease in resistance varied around 10 Ω and within 10-1 order of magnitude in different volunteers. In a word, the proposed electrode configuration effectively evaluated the degree of LMF, providing more feasibility for the design of wearable devices.
- 1 June 2008
- Published by Elsevier in Electrochimica Acta
- Vol. 53 (16) , 5186-5194
Potential and current oscillations during formaldehyde oxidation on platinum particles dispersed in three-dimensional pore networks of TiOx/Ti
- 1 June 2008
- Published by Elsevier in Electrochimica Acta
- Vol. 53 (16) , 5186-5194
Potential and current oscillations during formaldehyde oxidation on platinum particles dispersed in three-dimensional pore networks of TiOx/Ti