HYHaoyang You

Haoyang You

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haoyang You has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • Qiaogen Zhang

    State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, P.R. China

    13 shared publications
  • Tao Wen

    State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, P.R. China

    10 shared publications
  • Can Guo

    State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, P.R. China

    9 shared publications
  • Jingtan Ma

    State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, P.R. China

    9 shared publications
  • Jin Wang

    The Ohio State University,Center for High Performance Power Electronics (CHPPE),Columbus,OH,USA

    8 shared publications
  • Yifan Qin

    State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an, 710049, P.R. China

    8 shared publications

Latest Publications

  • Partial Discharge Inception Characteristics of Twisted Pairs Under Single Voltage Pulses Generated by Silicon-Carbide Devices

    by Zhuo Wei, Haoyang You, Pengyu Fu, Boxue Hu, Jin Wang

    Partial discharge (PD) is a major cause of degradation of motor winding insulation. It is a challenge to the successful electrification of all types of ground, sea, and aerial vehicles. However, the mechanism of PD under pulsewidth modulated voltages is not fully understood. This article studies PD inception characteristics in twisted pairs under single voltage pulses with reduced voltage overshoot, aiming to study the PD inception characteristics and mechanism without the influences of memory effects and voltage overshoot. The tests are conducted with a lab-designed 10-kV silicon carbide (SiC) device-based voltage pulse generator. The generator can produce voltage pulses with variable rise/fall times and pulse widths to emulate the output voltages of both silicon (Si) and SiC device-based power electronics converters. The voltage overshoot in this study has been limited to less than 5%. In addition, single voltage pulses are utilized as the excitation to remove charge memory effects. PD inception voltages, PD current magnitudes, and PD time delays of twisted pair samples are measured under various test conditions. It is found that the partial discharge inception voltage (PDIV) of the test sample decreases with reduced voltage rise time and increased voltage pulsewidth. Based on the test results, the impacts of voltage rise/fall times and pulse widths on PD behavior are explained using the extended volume-time theory. The relationships between PDIV, voltage rise/fall time, and pulsewidth are presented through empirical equations. Test results and analysis provide insights on the impacts of emerging wide bandgap devices in applications on motor winding insulations.


  • Open Access

    A Partial Discharge Study of Medium-Voltage Motor Winding Insulation Under Two-Level Voltage Pulses With High Dv/Dt

    by Boxue Hu, Zhuo Wei, Haoyang You, Risha Na, Rui Liu, Han Xiong, Pengyu Fu, Julia Zhang, Jin Wang

    Medium-voltage (e.g., 10 kV rated) silicon carbide (SiC) devices have great potentials in medium-voltage variable speed drives. But their high switching dv/dt can increase the voltage stress on motor windings and cause partial discharges. This paper presents a partial discharge study of a medium-voltage form-wound winding under two-level square-wave voltage pulses. A 10 kV SiC device-based test platform is built to generate voltage pulses with high dv/dt. A three-step test approach is proposed and employed to systematically investigate the effects of various voltage parameters on partial discharges. These include voltage rise/fall time, voltage pulse width, pulse repetitive rate, duty ratio, voltage polarity, fundamental frequency, and modulation index. Partial discharge inception voltages (PDIVs) and repetitive partial discharge inception voltages (RPDIVs) of the sample are measured with varied voltage parameters. Test results show that voltage rise/fall time is a major affecting factor which reduces PDIVs of the winding sample by 6.5% when it decreases from 800 ns to 100 ns. Based on test results, a hypothetical partial discharge mechanism is presented to explain the effects of fast voltage rise/fall edges. An empirical equation is also derived to estimate PDIVs of a winding sample under various voltage rise/fall time and pulse width conditions.


  • Partial Discharge Behaviors in Power Modules Under Square Pulses With Ultrafast dv/dt

    by Haoyang You, Zhuo Wei, Boxue Hu, Zheng Zhao, Risha Na, Jin Wang

    The unprecedented high-speed switching of Wide Bandgap (WBG) power devices may change the partial discharge (PD) behaviors of power modules, busbars and loads. However, very little research has been published on PD behaviors under square-wave pulses with ultra-fast dv/dt. To address this problem, this paper studies PD behaviors of direct bonded copper (DBC) samples with different trench distances and chamfer radii under single and repetitive square pulses with ultra-fast dv/dt. The results show that for the single pulse excitation partial discharge inception voltage (PDIV) decreases with increasing rise time if the pulse width is shorter than 300 s, and PDIV decreases with increasing pulse width. For repetitive pulse excitation, PDIV increases linearly with trench distance if the chamfer radius is larger than 0.5 mm, while it follows a concave curve if the chamfer radius is less than 0.5 mm. On the other hand, for a fixed trench distance, the PDIV changes quadratically with the chamfer radius increasing from 0 mm (right angle) to 0.7 mm. Based on experimental results, a PD model with bubble expansion theory is to explain the PD mechanism under ultra-fast dv/dt excitation, and an empirical equation for PDIV prediction is also derived.


  • Design of a Lightweight Low Inductance Power Module with Ceramic Baseplates

    by Xintong Lyu, Xingyue Tian, He Li, Haoyang You, Jin Wang

    A lightweight high power-density low inductance power module design is presented in this paper. This power module utilizes vertical loop design to reduce the stray inductance. Various ceramic materials have been explored for the design as baseplate materials. Compared to the conventional power module structure, simulation results show 50% reduction in maximum electric field strength and 47% reduction in CM leakage current. Dynamic testing results of the fabricated power module are presented. The power loop inductance is 1.1 nH, and the drain to source voltage sees 4.3% voltage overshoot under 700 V 25 A switching.


  • A Comprehensive PD Study Method on Power Modules with Ultra-high dv/dt Output

    by Haoyang You, Zhuo Wei, Boxue Hu, Risha Na, Jin Wang

    The unprecedented high speed switching of Wide Bandgap (WBG) power devices may change the partial discharge (PD) mechanism inside power modules. However, very few research have been published on PD research methods and PD behaviors under ultra-high dv/dt excitation voltages. To address these problems, a three-step PD study method is proposed in order to comprehensively study PD mechanism inside power module with ultra-high dv/dt excitation voltages. The three-step study consists of PD tests under single pulse, repetitive pulses, and Sinusoidal Pulse Width Modulation (SPWM) pulses. The preliminary results of single pulse tests show influences of the rise time and the pulse width on PD behaviors in power modules. Based on test data, a PD model based on the bubble expansion theory is provided to explain results. The results presented in this paper can provide a better understanding of PD mechanism in power modules under high dv/dt excitations.


  • Partial Discharge Behavior on Twisted Pair under Ultra-short Rise Time Square-wave Excitations

    by Zhuo Wei, Haoyang You, Boxue Hu, Risha Na, Jin Wang

    The use of wide-bandgap (WBG) semiconductor device is increasing due to its capability to operate at much higher voltage, frequency and temperature compared with traditional semiconductor device. WBG semiconductor device is capable to generate voltages with ultra-high dv/dt (ultra-short rise time), which would alter the voltage stress in various electrical apparatus, e.g., inverter-controlled motors, and consequently change partial discharge (PD) behavior. Combine this with the fact that PD detection in inverter-controlled motor winding, even with slow-rising voltages, is intrinsically complicated, the study of PD behavior under ultra-fast squarewave voltages is much needed. In this paper, experimental observations and results for twisted pair samples stressed by an impulse generator with the ability of generating ultra-fast square-wave voltage are presented. Statements and hypotheses on PD behaviors and mechanism under ultra-fast dv/dt squarewave excitations are also put forward based on the test results.


  • Partial Discharge Detection Strategies under Fast Rise Time Voltages Generated by Wide-bandgap Semiconductor Devices

    by Zhuo Wei, Haoyang You, Risha Na, Jin Wang

    Wide-bandgap (WBG) semiconductor device is one of the leading contenders for the next generation semiconductor device. Its advantages include but not limited to: higher voltage rating, switching speed and frequency. However, when electrical applications are driven by WBG devices, the voltage stress is inevitably changed. To be more precise, the voltage stress is more likely to be enhanced based on the premature failures observed for various applications driven by WBG devices. As has been well accepted, partial discharge (PD) is considered as the main cause for insulation failure in high frequency equipment. Thus, it is necessary to study PD behaviors under the new stress introduced by WBG device. However, the issue is inherently challenging due to the nature of the equipment under test and the extremely high dv/dt (fast rise time) square-wave voltage introduced. Huge charging/discharging current would be seen at the rising/falling edges of the square-wave pulse train. The magnitude of the charging/discharging current can be hundreds of or even thousands of times larger than that of PD pulse current. In some cases, even in frequency domain, the PD pulse current would be masked by the charging/discharging current. In this paper, a summary is made on past research related to PD detection strategies under fast rise time square-wave voltage or impulse voltage. Their advantages and disadvantages would be introduced to provide a full picture about this issue for future researchers when the need of PD detection under fast rise time excitations arises.


  • The Ohio State University Partial Discharge Detection Platform for Electric Machine Windings Driven by PWM Voltage Excitation

    by Han Xiong, Rui Liu, Boxue Hu, Haoyang You, Zhuo Wei, Julia Zhang, Jin Wang

    Unexpected premature insulation breakdown has been reported for many electric machines driven by variable speed drives (VSDs). A major cause is the reflected voltage overshoots at the machine winding caused by the pulse voltage excitation, leading to severe stress on the insulation system. At The Ohio State University (OSU), we have started a series of efforts to understand the degradation and breakdown of the insulation systems in electric machines driven by VSDs. This paper reports our activities on partial discharge (PD) detection and characterization for random-wound low voltage and form-wound medium voltage coils excited by PWM voltages. A PD detection platform has been established consisting of three main systems: the testing samples and setups, the pulsed voltage generation system, and the PD detection system. One silicon (Si) based and two silicon-carbide (SiC) based pulsed voltage generators were employed to produce voltage excitations with a magnitude up to 10 kV and a $dV/dt$ up to $\mathbf{70\ kV}/\mu\mathbf{s}$ . The PD detection system, moreover, installed nine sensors catering to five different physical manifestations during PD: electrical current, electromagnetic wave, optical light emission, acoustic ultrasound emission and chemical ozone emission. The detection effectiveness of each type of sensor is presented and compared using twisted pairs of magnet wire samples. The demonstrated results hope to provide a better understanding of the effect of VSDs on the behaviors of PDs in electric machine winding insulation systems, and also some insight for the selection and evaluation of PD detectors for various VSD applications.


  • Partial Discharge Behaviors in Power Module under Very High Dv/dt Repetitive Square Voltages

    by Haoyang You, Zhuo Wei, Mohammed Aldawsari, Boxue Hu, Risha Na, Jin Wang

    Partial discharge (PD) is more likely to happen in the power module due to the increasing switching speed of new generation semiconductors. However, little research has been done to study the PD behaviors under very fast dv/dt (above $50 \mathrm{kV}/\mu\mathrm{s}$ ) repetitive square-wave voltages. To address this problem, PD behaviors of designed direct bonded copper (DBC) samples with different trench distances and chamfer radiuses under fast dv/dt ( $130 \mathrm{kV}/\mu\mathrm{s}$ ) repetitive square voltages are studied. The results show that, for different trench distances, the partial discharge inception voltage (PDIV) increases linearly with increasing trench distances when the chamfer radius is larger than 0.5 mm, while PDIV shows a hump curve when the chamfer radius is less than 0.5 mm. The apparent charge becomes 23 nC with a large dispersion when the trench distance is 0.5 mm. For different chamfer radiuses, PDIV presents a U-shape shape curve with increasing radiuses from the zero (right angle) to 0.7 mm. The apparent charge is about 325 pC with a large dispersion when the chamfer radius is zero. The detailed experiment results and discussions are presented in this paper.