ÁSÁlvaro J. Sánchez-Ortega

Álvaro J. Sánchez-Ortega

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Álvaro J. Sánchez-Ortega has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improving Cell Viability and Velocity in μ-Extrusion Bioprinting with a Novel Pre-Incubator Bioprinter and a Standard FDM 3D Printing Nozzle

    by Juan C. Gómez-Blanco, Victor Galván-Chacón, David Patrocinio, Manuel Matamoros, Álvaro J. Sánchez-Ortega, Alfonso C. Marcos, María Duarte-León, Federica Marinaro, José B. Pagador, Francisco M. Sánchez-Margallo

    Bioprinting is a promising emerging technology. It has been widely studied by the scientific community for the possibility to create transplantable artificial tissues, with minimal risk to the patient. Although the biomaterials and cells to be used are being carefully studied, there is still a long way to go before a bioprinter can easily and quickly produce printings without harmful effects on the cells. In this sense, we have developed a new μ-extrusion bioprinter formed by an Atom Proton 3D printer, an atmospheric enclosure and a new extrusion-head capable to increment usual printing velocity. Hence, this work has two main objectives. First, to experimentally study the accuracy and precision. Secondly, to study the influence of flow rates on cellular viability using this novel μ-extrusion bioprinter in combination with a standard FDM 3D printing nozzle. Our results show an X, Y and Z axis movement accuracy under 17 μm with a precision around 12 μm while the extruder values are under 5 and 7 μm, respectively. Additionally, the cell viability obtained from different volumetric flow tests varies from 70 to 90%. So, the proposed bioprinter and nozzle can control the atmospheric conditions and increase the volumetric flow speeding up the bioprinting process without compromising the cell viability.


  • Open Access

    Temperature and Humidity PID Controller for a Bioprinter Atmospheric Enclosure System

    by Manuel Matamoros, J. Carlos Gómez-Blanco, Álvaro J. Sánchez, Enrique Mancha, Alfonso C. Marcos, J. Pablo Carrasco-Amador, J. Blas Pagador

    Bioprinting is a complex process, highly dependent on bioink properties (materials and cells) and environmental conditions (mainly temperature, humidity and CO2 concentration) during the bioprinting process. To guarantee proper cellular viability and an accurate geometry, it is mandatory to control all these factors. Despite internal factors, such as printing pressures, temperatures or speeds, being well-controlled in actual bioprinters, there is a lack in the controlling of external parameters, such as room temperature or humidity. In this sense, the objective of this work is to control the temperature and humidity of a new, atmospheric enclosure system for bioprinting. The control has been carried out with a decoupled proportional integral derivative (PID) controller that was designed, simulated and experimentally tested in order to ensure the proper operation of all its components. Finally, the PID controller can stabilize the atmospheric enclosure system temperature in 311 s and the humidity in 65 s, with an average error of 1.89% and 1.30%, respectively. In this sense, the proposed atmospheric enclosure system can reach and maintain the proper temperature and humidity values during post-printing and provide a pre-incubation environment that promotes stability, integrity and cell viability of the 3D bioprinted structures.


  • Open Access

    Fabricación y evaluación de una cámara climática para el desarrollo de técnicas de bioimpresión 3D

    by Manuel Matamoros Pacheco, Álvaro Sánchez Ortega, José Luis Canito Lobo, Alfonso Carlos Marcos Romero, Juan Pablo Carrasco Amador, Juan Carlos Gómez Blanco, Enrique Mancha Sánchez, Francisco Miguel Sánchez Margallo, José Blas Pagador Carrasco