Hokyung Jang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hokyung Jang has a total of 260 co-authors. Here are the top co-authors by number of shared publications:
- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
13 shared publications - Yonggang Huang
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
11 shared publications - Yoonseok Park
Department of Materials Science and Engineering, Kyung Hee University, Yongin 17104, Republic of Korea
9 shared publications - Hyoyoung Jeong
Department of Electrical and Computer Engineering, University of California, CA, USA
8 shared publications Jong Uk Kim
School of Chemical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
8 shared publicationsRaudel Avila
Department of Mechanical Engineering, Northwestern University, Evanston, USA
8 shared publications
Latest Publications
- 24 June 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (26)
Characteristics of grafted monocrystalline Si/ β -Ga2O3p–n heterojunction
Beta-phase gallium oxide (β-Ga2O3) has exceptional electronic properties with vast potential in power and radio frequency electronics. Despite the excellent demonstrations of high-performance unipolar devices, the lack of effective p-type dopants in β-Ga2O3 has hindered the further development of Ga2O3-based bipolar devices. In this work, we applied the semiconductor grafting approach and fabricated monocrystalline Si/β-Ga2O3p–n heterojunctions, of which the characteristics were systematically studied. The heterojunctions demonstrated a diode rectification over 1.3 × 107 at ±2 V with a diode ideality factor of 1.13. Furthermore, capacitance–voltage (C–V) measurement showed frequency dispersion-free characteristics from 10 to 900 kHz. The interface defect density (Dit) was calculated as 1–3 × 1012/cm2 eV. Scanning transmission electron microscopy (STEM) and x-ray photoelectron spectroscopy (XPS) revealed that an ultrathin oxygen-rich layer existed on the Ga2O3 surface and later formed an ultrathin interfacial layer after bonding with Si. It is speculated that the excessive oxygen at the Ga2O3 surface enhanced the passivation of the Si dangling bonds and thus reduced Dit. This work improved our understanding of interface properties of the semiconductor grafting approach, providing useful guidance on the future development of Si/Ga2O3 heterojunction devices.
- 24 June 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (26)
Characteristics of grafted monocrystalline Si/ β -Ga2O3p–n heterojunction
Beta-phase gallium oxide (β-Ga2O3) has exceptional electronic properties with vast potential in power and radio frequency electronics. Despite the excellent demonstrations of high-performance unipolar devices, the lack of effective p-type dopants in β-Ga2O3 has hindered the further development of Ga2O3-based bipolar devices. In this work, we applied the semiconductor grafting approach and fabricated monocrystalline Si/β-Ga2O3p–n heterojunctions, of which the characteristics were systematically studied. The heterojunctions demonstrated a diode rectification over 1.3 × 107 at ±2 V with a diode ideality factor of 1.13. Furthermore, capacitance–voltage (C–V) measurement showed frequency dispersion-free characteristics from 10 to 900 kHz. The interface defect density (Dit) was calculated as 1–3 × 1012/cm2 eV. Scanning transmission electron microscopy (STEM) and x-ray photoelectron spectroscopy (XPS) revealed that an ultrathin oxygen-rich layer existed on the Ga2O3 surface and later formed an ultrathin interfacial layer after bonding with Si. It is speculated that the excessive oxygen at the Ga2O3 surface enhanced the passivation of the Si dangling bonds and thus reduced Dit. This work improved our understanding of interface properties of the semiconductor grafting approach, providing useful guidance on the future development of Si/Ga2O3 heterojunction devices.
- Top Cited Papers
- 10 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1215-1228
A battery-less wireless implant for the continuous monitoring of vascular pressure, flow rate and temperature
Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.
- 10 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1215-1228
Top Cited PapersA battery-less wireless implant for the continuous monitoring of vascular pressure, flow rate and temperature
Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.
- 1 January 2022
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 50
Artificial stretchable armor for skin-interfaced wearable devices and soft robotics
- 1 January 2022
- Published by Elsevier in Extreme Mechanics Letters
- Vol. 50
Artificial stretchable armor for skin-interfaced wearable devices and soft robotics
- Open Access
- 18 November 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1
Author Correction: Battery-free, wireless soft sensors for continuous multi-site measurements of pressure and temperature from patients at risk for pressure injuries
- 18 November 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1
Open AccessAuthor Correction: Battery-free, wireless soft sensors for continuous multi-site measurements of pressure and temperature from patients at risk for pressure injuries
- Open Access
- 18 October 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (43)
Miniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants
Significance: Early detection of infant neuromotor pathologies is critical for timely therapeutic interventions that rely on early-life neuroplasticity. Traditional assessments rely on subjective expert evaluations or specialized medical facilities, making them challenging to scale in remote and/or resource-constrained settings. The results presented here aim to democratize these evaluations using wireless networks of miniaturized, skin-integrated sensors that digitize movement behaviors and vital signs of infants in a cost-effective manner. The resulting data yield full-body motion reconstructions in the form of deidentified infant avatars, along with a range of important cardiopulmonary information. This technology approach enables rapid, routine evaluations of infants at any age via an engineering platform that has potential for use in nearly any setting across developed and developing countries alike.
- 18 October 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (43)
Open AccessMiniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants
Significance: Early detection of infant neuromotor pathologies is critical for timely therapeutic interventions that rely on early-life neuroplasticity. Traditional assessments rely on subjective expert evaluations or specialized medical facilities, making them challenging to scale in remote and/or resource-constrained settings. The results presented here aim to democratize these evaluations using wireless networks of miniaturized, skin-integrated sensors that digitize movement behaviors and vital signs of infants in a cost-effective manner. The resulting data yield full-body motion reconstructions in the form of deidentified infant avatars, along with a range of important cardiopulmonary information. This technology approach enables rapid, routine evaluations of infants at any age via an engineering platform that has potential for use in nearly any setting across developed and developing countries alike.
- Top Cited Papers
- 22 September 2021
- Published by Springer Nature in Nature
- Vol. 597 (7877) , 503-510
Three-dimensional electronic microfliers inspired by wind-dispersed seeds
Large, distributed collections of miniaturized, wireless electronic devices1,2 may form the basis of future systems for environmental monitoring3, population surveillance4, disease management5 and other applications that demand coverage over expansive spatial scales. Aerial schemes to distribute the components for such networks are required, and—inspired by wind-dispersed seeds6—we examined passive structures designed for controlled, unpowered flight across natural environments or city settings. Techniques in mechanically guided assembly of three-dimensional (3D) mesostructures7,8,9 provide access to miniature, 3D fliers optimized for such purposes, in processes that align with the most sophisticated production techniques for electronic, optoelectronic, microfluidic and microelectromechanical technologies. Here we demonstrate a range of 3D macro-, meso- and microscale fliers produced in this manner, including those that incorporate active electronic and colorimetric payloads. Analytical, computational and experimental studies of the aerodynamics of high-performance structures of this type establish a set of fundamental considerations in bio-inspired design, with a focus on 3D fliers that exhibit controlled rotational kinematics and low terminal velocities. An approach that represents these complex 3D structures as discrete numbers of blades captures the essential physics in simple, analytical scaling forms, validated by computational and experimental results. Battery-free, wireless devices and colorimetric sensors for environmental measurements provide simple examples of a wide spectrum of applications of these unusual concepts.
- 22 September 2021
- Published by Springer Nature in Nature
- Vol. 597 (7877) , 503-510
Top Cited PapersThree-dimensional electronic microfliers inspired by wind-dispersed seeds
Large, distributed collections of miniaturized, wireless electronic devices1,2 may form the basis of future systems for environmental monitoring3, population surveillance4, disease management5 and other applications that demand coverage over expansive spatial scales. Aerial schemes to distribute the components for such networks are required, and—inspired by wind-dispersed seeds6—we examined passive structures designed for controlled, unpowered flight across natural environments or city settings. Techniques in mechanically guided assembly of three-dimensional (3D) mesostructures7,8,9 provide access to miniature, 3D fliers optimized for such purposes, in processes that align with the most sophisticated production techniques for electronic, optoelectronic, microfluidic and microelectromechanical technologies. Here we demonstrate a range of 3D macro-, meso- and microscale fliers produced in this manner, including those that incorporate active electronic and colorimetric payloads. Analytical, computational and experimental studies of the aerodynamics of high-performance structures of this type establish a set of fundamental considerations in bio-inspired design, with a focus on 3D fliers that exhibit controlled rotational kinematics and low terminal velocities. An approach that represents these complex 3D structures as discrete numbers of blades captures the essential physics in simple, analytical scaling forms, validated by computational and experimental results. Battery-free, wireless devices and colorimetric sensors for environmental measurements provide simple examples of a wide spectrum of applications of these unusual concepts.
- Top Cited PapersOpen Access
- 24 August 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-16
Battery-free, wireless soft sensors for continuous multi-site measurements of pressure and temperature from patients at risk for pressure injuries
Capabilities for continuous monitoring of pressures and temperatures at critical skin interfaces can help to guide care strategies that minimize the potential for pressure injuries in hospitalized patients or in individuals confined to the bed. This paper introduces a soft, skin-mountable class of sensor system for this purpose. The design includes a pressure-responsive element based on membrane deflection and a battery-free, wireless mode of operation capable of multi-site measurements at strategic locations across the body. Such devices yield continuous, simultaneous readings of pressure and temperature in a sequential readout scheme from a pair of primary antennas mounted under the bedding and connected to a wireless reader and a multiplexer located at the bedside. Experimental evaluation of the sensor and the complete system includes benchtop measurements and numerical simulations of the key features. Clinical trials involving two hemiplegic patients and a tetraplegic patient demonstrate the feasibility, functionality and long-term stability of this technology in operating hospital settings.
- 24 August 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-16
Top Cited PapersOpen AccessBattery-free, wireless soft sensors for continuous multi-site measurements of pressure and temperature from patients at risk for pressure injuries
Capabilities for continuous monitoring of pressures and temperatures at critical skin interfaces can help to guide care strategies that minimize the potential for pressure injuries in hospitalized patients or in individuals confined to the bed. This paper introduces a soft, skin-mountable class of sensor system for this purpose. The design includes a pressure-responsive element based on membrane deflection and a battery-free, wireless mode of operation capable of multi-site measurements at strategic locations across the body. Such devices yield continuous, simultaneous readings of pressure and temperature in a sequential readout scheme from a pair of primary antennas mounted under the bedding and connected to a wireless reader and a multiplexer located at the bedside. Experimental evaluation of the sensor and the complete system includes benchtop measurements and numerical simulations of the key features. Clinical trials involving two hemiplegic patients and a tetraplegic patient demonstrate the feasibility, functionality and long-term stability of this technology in operating hospital settings.
- 23 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (17) , 18706-18714
Wireless, Accumulation Mode Dosimeters for Monitoring Pulsed and Non-Pulsed Germicidal Lamps
Infectious diseases such as the COVID-19 pandemic demands simple and effective disinfection techniques. Ultraviolet germicidal irradiation (UVGI) is one such method in common use for decontamination of hospital rooms. Practical technologies designed to monitor UVGI ensure the delivery of effective dose for reliable germicide. Existing UVGI dosimeters rely on intermittent measurements of intensity as the basis for a numerical integration scheme that approximates dose. Traditional devices are ineffective particularly with pulsed UVGI lamps that emit ms pulses of duration shorter than the interval of measurement. Here, we present a compact, accumulation mode dosimeter (AMD) that detects continuously, as opposed to intermittently, at single or multiple UVGI wavelengths. AMD utilizes an array of photodiodes and supercapacitors to passively transduce and capture photocurrent generated by UVGI without the use of an external power. The accumulated voltage across the supercapacitors then serves as a measure of UVGI dose. A key result is that sampling intervals of AMD do not constrain measurement accuracy. When implemented with a wireless transponder, AMD supports light-adaptive sampling scheme designed to adjust sampling interval to intensity and period of UVGI exposure. Compared to time-based sampling adopted by conventional sensors, light-adaptive sampling autonomously optimizes expanded power by minimizing current consumption during periods of low or no UVGI. Benchtop studies of its use with pulsed Xenon lamps (pulse 5 ms) sampled at long intervals (> 1s) highlights key feature. Demonstration of AMD during UVGI of E. Coli cultures represents an example in dose dependent effects on disinfection.
- 23 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (17) , 18706-18714
Wireless, Accumulation Mode Dosimeters for Monitoring Pulsed and Non-Pulsed Germicidal Lamps
Infectious diseases such as the COVID-19 pandemic demands simple and effective disinfection techniques. Ultraviolet germicidal irradiation (UVGI) is one such method in common use for decontamination of hospital rooms. Practical technologies designed to monitor UVGI ensure the delivery of effective dose for reliable germicide. Existing UVGI dosimeters rely on intermittent measurements of intensity as the basis for a numerical integration scheme that approximates dose. Traditional devices are ineffective particularly with pulsed UVGI lamps that emit ms pulses of duration shorter than the interval of measurement. Here, we present a compact, accumulation mode dosimeter (AMD) that detects continuously, as opposed to intermittently, at single or multiple UVGI wavelengths. AMD utilizes an array of photodiodes and supercapacitors to passively transduce and capture photocurrent generated by UVGI without the use of an external power. The accumulated voltage across the supercapacitors then serves as a measure of UVGI dose. A key result is that sampling intervals of AMD do not constrain measurement accuracy. When implemented with a wireless transponder, AMD supports light-adaptive sampling scheme designed to adjust sampling interval to intensity and period of UVGI exposure. Compared to time-based sampling adopted by conventional sensors, light-adaptive sampling autonomously optimizes expanded power by minimizing current consumption during periods of low or no UVGI. Benchtop studies of its use with pulsed Xenon lamps (pulse 5 ms) sampled at long intervals (> 1s) highlights key feature. Demonstration of AMD during UVGI of E. Coli cultures represents an example in dose dependent effects on disinfection.
- Open Access
- 14 May 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (20) , eabg3092
Differential cardiopulmonary monitoring system for artifact-canceled physiological tracking of athletes, workers, and COVID-19 patients
Wearable electronics with dual-sensing modalities enable artifact-free health monitoring through differential detection.
- 14 May 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (20) , eabg3092
Open AccessDifferential cardiopulmonary monitoring system for artifact-canceled physiological tracking of athletes, workers, and COVID-19 patients
Wearable electronics with dual-sensing modalities enable artifact-free health monitoring through differential detection.
- Open Access
- 10 May 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (20)
Comprehensive pregnancy monitoring with a network of wireless, soft, and flexible sensors in high- and low-resource health settings
Significance: Monitoring vital signs for laboring women and their fetuses is foundational to the delivery of obstetrical care; however, monitoring platforms for pregnancy have undergone little innovation over the last several decades with many low-income settings lacking basic access. We report a new time-synchronized, flexible, and wireless sensor system applicable across the entire continuum of antepartum and postpartum care that provides continuous, comprehensive, and noninvasive monitoring (heart rate, respiratory rate, and pulse oxygenation) compatible with a wide range of mobile devices. This system offers advanced features such as continuous blood pressure, uterine electrohysterography, and automated body position classification. We further demonstrate the performance of this new system among pregnant individuals ( n = 576) in both high-resource settings and low-resource care settings.
- 10 May 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (20)
Open AccessComprehensive pregnancy monitoring with a network of wireless, soft, and flexible sensors in high- and low-resource health settings
Significance: Monitoring vital signs for laboring women and their fetuses is foundational to the delivery of obstetrical care; however, monitoring platforms for pregnancy have undergone little innovation over the last several decades with many low-income settings lacking basic access. We report a new time-synchronized, flexible, and wireless sensor system applicable across the entire continuum of antepartum and postpartum care that provides continuous, comprehensive, and noninvasive monitoring (heart rate, respiratory rate, and pulse oxygenation) compatible with a wide range of mobile devices. This system offers advanced features such as continuous blood pressure, uterine electrohysterography, and automated body position classification. We further demonstrate the performance of this new system among pregnant individuals ( n = 576) in both high-resource settings and low-resource care settings.