Mark T. Burgess
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark T. Burgess has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jeffrey A. Ketterling
Department of Radiology, Weill Cornell Medicine 2 , New York, New York 10022
3 shared publicationsChristian Aguilar
Department of Radiology, University of Michigan, Ann Arbor, MI, 48109
1 shared publicationDaniel Heller
Molecular Pharmacology Program, Memorial Sloan Kettering Cancer Ctr., New York, NY
1 shared publicationDaniel Tylawsky
Molecular Pharmacology Program, Memorial Sloan Kettering Cancer Ctr., New York, NY
1 shared publication- Elisa Evgenia Konofagou
Department of Biomedical Engineering, Columbia University, New York, USA
1 shared publication - Hermes Arytto Salles Kamimura
Columbia University
1 shared publication
Latest Publications
- 1 October 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 160 (4) , 2951-2959
Transient cavitation dynamics of vaporized perfluorocarbon nanodroplets measured with an acoustical camera
Perfluorocarbon nanodroplets are metastable phase-change contrast agents that convert into gas bubbles on demand through acoustic droplet vaporization (ADV). Their transient radial dynamics are difficult to measure without high-speed optical imaging. An acoustical camera approach characterizes post-ADV bubble dynamics acoustically. Perfluoropentane nanodroplets were activated with a 5 MHz focused pulse (peak negative pressure ≈5 MPa) and simultaneously probed at 35 MHz, with the side-scattered signal detected by an orthogonal receiver. Scattered amplitude scales with bubble radius, so the Hilbert-transformed envelope yields a relative radius–time response with microsecond resolution, revealing rapid growth and collapse consistent with transient inertial cavitation. Collapse times give a mean maximum bubble radius of 13.2 ± 1.8μm (N=475), roughly 300 times the >∼46 nm precursor radius, confirming strongly inertial overshoot. Deriving from pulse timing rather than amplitude, this estimate is independent of bubble position within the probe beam. The 35 MHz focal zone is approximately four times narrower than the 5 MHz activation zone, so the detected amplitude reflects lateral position rather than size, and only 7% of events fall within ±20% of the timing estimate. The technique offers a low-complexity route to quantifying post-ADV cavitation dynamics and comparing nanodroplet formulations.
- 1 October 2026
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 160 (4) , 2951-2959
Transient cavitation dynamics of vaporized perfluorocarbon nanodroplets measured with an acoustical camera
Perfluorocarbon nanodroplets are metastable phase-change contrast agents that convert into gas bubbles on demand through acoustic droplet vaporization (ADV). Their transient radial dynamics are difficult to measure without high-speed optical imaging. An acoustical camera approach characterizes post-ADV bubble dynamics acoustically. Perfluoropentane nanodroplets were activated with a 5 MHz focused pulse (peak negative pressure ≈5 MPa) and simultaneously probed at 35 MHz, with the side-scattered signal detected by an orthogonal receiver. Scattered amplitude scales with bubble radius, so the Hilbert-transformed envelope yields a relative radius–time response with microsecond resolution, revealing rapid growth and collapse consistent with transient inertial cavitation. Collapse times give a mean maximum bubble radius of 13.2 ± 1.8μm (N=475), roughly 300 times the >∼46 nm precursor radius, confirming strongly inertial overshoot. Deriving from pulse timing rather than amplitude, this estimate is independent of bubble position within the probe beam. The 35 MHz focal zone is approximately four times narrower than the 5 MHz activation zone, so the detected amplitude reflects lateral position rather than size, and only 7% of events fall within ±20% of the timing estimate. The technique offers a low-complexity route to quantifying post-ADV cavitation dynamics and comparing nanodroplet formulations.
- Open Access
- 1 March 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (3_Suppleme) , A250
Microcavitation dynamics of vaporized perfluorocarbon nanodroplets captured with an acoustical camera
Perfluorocarbon nanodroplets are on-demand cavitation nuclei for numerous biomedical applications. These nanodroplets remain in a metastable state until an ultrasound pulse of sufficient negative pressure initiates conversion from a liquid droplet into a gaseous micro- or nano-bubble in a process termed acoustic droplet vaporization (ADV). Extensive research has gone into understanding their interaction with ultrasound at varying acoustic and ambient conditions. Recent studies have detected intra- and post-excitation collapse emissions indicative of inertial cavitation. This study aims to further understand the post-ADV dynamics of perfluorocarbon nanodroplets with an acoustical camera technique. Nanodroplets were activated with a low-frequency ultrasound pulse (5 MHz) while being insonified with a high-frequency (35 MHz) probing wave. The side scattered emissions from the probing wave were captured with another matched high-frequency transducer. The amplitude modulation of these emissions is proportional to the radial strain; thus, a relative radius-time curve can be extracted from the scattered signal after filtering and enveloping. Results show that this technique can capture the radial growth and collapse curves of these newly formed bubbles and aligns well with intra- and post-excitation emissions indicative of inertial cavitation. This approach could be useful to understand post-ADV dynamics of various droplet formulations.
- 1 March 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (3_Suppleme) , A250
Open AccessMicrocavitation dynamics of vaporized perfluorocarbon nanodroplets captured with an acoustical camera
Perfluorocarbon nanodroplets are on-demand cavitation nuclei for numerous biomedical applications. These nanodroplets remain in a metastable state until an ultrasound pulse of sufficient negative pressure initiates conversion from a liquid droplet into a gaseous micro- or nano-bubble in a process termed acoustic droplet vaporization (ADV). Extensive research has gone into understanding their interaction with ultrasound at varying acoustic and ambient conditions. Recent studies have detected intra- and post-excitation collapse emissions indicative of inertial cavitation. This study aims to further understand the post-ADV dynamics of perfluorocarbon nanodroplets with an acoustical camera technique. Nanodroplets were activated with a low-frequency ultrasound pulse (5 MHz) while being insonified with a high-frequency (35 MHz) probing wave. The side scattered emissions from the probing wave were captured with another matched high-frequency transducer. The amplitude modulation of these emissions is proportional to the radial strain; thus, a relative radius-time curve can be extracted from the scattered signal after filtering and enveloping. Results show that this technique can capture the radial growth and collapse curves of these newly formed bubbles and aligns well with intra- and post-excitation emissions indicative of inertial cavitation. This approach could be useful to understand post-ADV dynamics of various droplet formulations.
- Open Access
- 3 October 2023
- Published by Wiley in Molecular Oncology
- Vol. 17 (10) , 1947-1949
From bedside to portable and wearable: development of a conformable ultrasound patch for deep breast tissue imaging
A breakthrough study from Du et al. has developed a wearable, ultrasound imaging patch for standardized and reproducible breast tissue imaging. The technology utilizes a honeycomb patch design to facilitate guided movement of the ultrasound array, enabling comprehensive, multiangle breast imaging. The system was validated in vitro and in vivo with a single human subject and has the potential for early‐stage breast cancer detection. This study addressed the current limitations of wearable ultrasound technologies, including imaging over large, curvilinear organs and integration of superior piezoelectric materials for high‐performance ultrasound arrays. The transition of ultrasound from the bedside to portable and wearable devices will pave the way for integration with big data collection, such as artificial intelligence (AI)‐based diagnosis and personalized ultrasonographic profile generation, for rapid and objective measurements. This advancement is especially important in the context of breast cancer, where early diagnosis and assessment of medical therapy responses are paramount to patient care.
- 3 October 2023
- Published by Wiley in Molecular Oncology
- Vol. 17 (10) , 1947-1949
Open AccessFrom bedside to portable and wearable: development of a conformable ultrasound patch for deep breast tissue imaging
A breakthrough study from Du et al. has developed a wearable, ultrasound imaging patch for standardized and reproducible breast tissue imaging. The technology utilizes a honeycomb patch design to facilitate guided movement of the ultrasound array, enabling comprehensive, multiangle breast imaging. The system was validated in vitro and in vivo with a single human subject and has the potential for early‐stage breast cancer detection. This study addressed the current limitations of wearable ultrasound technologies, including imaging over large, curvilinear organs and integration of superior piezoelectric materials for high‐performance ultrasound arrays. The transition of ultrasound from the bedside to portable and wearable devices will pave the way for integration with big data collection, such as artificial intelligence (AI)‐based diagnosis and personalized ultrasonographic profile generation, for rapid and objective measurements. This advancement is especially important in the context of breast cancer, where early diagnosis and assessment of medical therapy responses are paramount to patient care.
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A32
Assessing the effects of ultrasound parameters on P-selectin expression for active targeting of nanotherapeutics
P-selectin is a nanotherapeutic target for enhanced passage of nanoscale drug delivery systems across the vascular barrier and into tumors via transcytosis. While many tumors express P-selection, radiation can be used to induce expression in tumors devoid of P-selectin. This study aims to test whether ultrasound can elicit a similar response through mechanical or thermal bioeffects. Preliminary experiments were performed in vitro using brain tissue derived mouse endothelial cells. A Vevo SoniGene system was used to sonicate cells with low-intensity (2 W/cm2) pulsed ultrasound in a 12-well cell culture plate. Upregulation of P-selectin was seen using a 60 second treatment duration at 50% and 100% duty cycles via flow cytometry analysis. The mean fluorescence intensity, normalized to nontreated cells, was 32 + /- 17.4 and 103 + /- 37.2 for 50% and 100% duty cycles, respectively. Viability remained high with 72.6 + /- 14.5 and 77.5 + /- 8.3% of cells viable for both 50% and 100% duty cycle groups, respectively. These results highlight the potential of ultrasound for active targeting using non-ionizing energy and for tumors where radiation is not feasible. Future studies will identify associated bioeffects and compare ultrasound with radiation for nanotherapeutic delivery in small animal tumor models.
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A32
Open AccessAssessing the effects of ultrasound parameters on P-selectin expression for active targeting of nanotherapeutics
P-selectin is a nanotherapeutic target for enhanced passage of nanoscale drug delivery systems across the vascular barrier and into tumors via transcytosis. While many tumors express P-selection, radiation can be used to induce expression in tumors devoid of P-selectin. This study aims to test whether ultrasound can elicit a similar response through mechanical or thermal bioeffects. Preliminary experiments were performed in vitro using brain tissue derived mouse endothelial cells. A Vevo SoniGene system was used to sonicate cells with low-intensity (2 W/cm2) pulsed ultrasound in a 12-well cell culture plate. Upregulation of P-selectin was seen using a 60 second treatment duration at 50% and 100% duty cycles via flow cytometry analysis. The mean fluorescence intensity, normalized to nontreated cells, was 32 + /- 17.4 and 103 + /- 37.2 for 50% and 100% duty cycles, respectively. Viability remained high with 72.6 + /- 14.5 and 77.5 + /- 8.3% of cells viable for both 50% and 100% duty cycle groups, respectively. These results highlight the potential of ultrasound for active targeting using non-ionizing energy and for tumors where radiation is not feasible. Future studies will identify associated bioeffects and compare ultrasound with radiation for nanotherapeutic delivery in small animal tumor models.
- 4 February 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 48 (5) , 743-759
Slow-Flow Ultrasound Localization Microscopy Using Recondensation of Perfluoropentane Nanodroplets
- 4 February 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 48 (5) , 743-759
Slow-Flow Ultrasound Localization Microscopy Using Recondensation of Perfluoropentane Nanodroplets
- Open Access
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (11) , 3391-3402
Displacement Imaging for Focused Ultrasound Peripheral Nerve Neuromodulation
Focused ultrasound (FUS) is an emerging technique for neuromodulation due to its noninvasive application and high depth penetration. Recent studies have reported success in modulation of brain circuits, peripheral nerves, ion channels, and organ structures. In particular, neuromodulation of peripheral nerves and the underlying mechanisms remain comparatively unexplored in vivo. Lack of methodologies for FUS targeting and monitoring impede further research in in vivo studies. Thus, we developed a method that non-invasively measures nerve engagement, via tissue displacement, during FUS neuromodulation of in vivo nerves using simultaneous high frame-rate ultrasound imaging. Using this system, we can validate, in real-time, FUS targeting of the nerve and characterize subsequent compound muscle action potentials (CMAPs) elicited from sciatic nerve activation in mice using 0.5 to 5 ms pulse durations and 22 - 28 MPa peak positive stimulus pressures at 4 MHz. Interestingly, successful motor excitation from FUS neuromodulation required a minimum interframe nerve displacement of 18 μm without any displacement incurred at the skin or muscle levels. Moreover, CMAPs detected in mice monotonically increased with interframe nerve displacements within the range of 18 to 300 μm. Thus, correlation between nerve displacement and motor activation constitutes strong evidence FUS neuromodulation is driven by a mechanical effect given that tissue deflection is a result of highly focused acoustic radiation force.
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (11) , 3391-3402
Open AccessDisplacement Imaging for Focused Ultrasound Peripheral Nerve Neuromodulation
Focused ultrasound (FUS) is an emerging technique for neuromodulation due to its noninvasive application and high depth penetration. Recent studies have reported success in modulation of brain circuits, peripheral nerves, ion channels, and organ structures. In particular, neuromodulation of peripheral nerves and the underlying mechanisms remain comparatively unexplored in vivo. Lack of methodologies for FUS targeting and monitoring impede further research in in vivo studies. Thus, we developed a method that non-invasively measures nerve engagement, via tissue displacement, during FUS neuromodulation of in vivo nerves using simultaneous high frame-rate ultrasound imaging. Using this system, we can validate, in real-time, FUS targeting of the nerve and characterize subsequent compound muscle action potentials (CMAPs) elicited from sciatic nerve activation in mice using 0.5 to 5 ms pulse durations and 22 - 28 MPa peak positive stimulus pressures at 4 MHz. Interestingly, successful motor excitation from FUS neuromodulation required a minimum interframe nerve displacement of 18 μm without any displacement incurred at the skin or muscle levels. Moreover, CMAPs detected in mice monotonically increased with interframe nerve displacements within the range of 18 to 300 μm. Thus, correlation between nerve displacement and motor activation constitutes strong evidence FUS neuromodulation is driven by a mechanical effect given that tissue deflection is a result of highly focused acoustic radiation force.