BBBradley J. Bazuin

Bradley J. Bazuin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bradley J. Bazuin has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of Microneedle-Induced Pore Architecture on Electrochemical Performance of Dry-Processed NMC811 Cathodes

    by Pranava Avuthu, Valliammai Palaniappan, Alek K. Hultberg, Dinesh Maddipatla, AliMohammad Adineh, Bradley Bazuin, Massood Z. Atashbar

  • Development of Self-Powered e-Gear Selector Based on Single-Electrode Triboelectric Nanogenerator (TENG) Technology

    by Sam Ali, Dinesh Maddipatla, Bradley J. Bazuin, Massood Z. Atashbar

    A novel e-Gear selector single electrode based triboelectric nanogenerator (TENG) was successfully designed, fabricated, and tested on flexible substrates. The proposed device consists of four TENG sensors representing the traditional gear shift selector (P, R, N, and D). Leather, cotton, paper, and thermoplastic polyurethane (TPU) were selected as bottom triboelectric layers for TENG 1, TENG 2, TENG 3, and TENG 4, respectively. Silver (Ag) ink was screen-printed on the backside of each layer representing the single electrode. Human skin was chosen as the top triboelectric layer. Based on the selection of the materials, each TENG device generates different output voltages, enabling the selection of the intended gear mode without the need for a complex control algorithm. The TENG device was characterized in terms of open circuit voltage (V oc ) and short circuit current (I sc ). The repeatability and reproducibility of the TENG device were evaluated by fabricating three samples of each TENG device and by testing each TENG device three times. An average V oc of 4.27 ± 0.36 V pp , 7 ± 0.31 V pp , 9.05 ± 0.21 V pp , and 12.38 ± 0.34 V pp , resulted in a power density of 0.37 ± 0.05 μW/cm², 0.72 ± 0.09 μW/cm², 0.95 ± 0.07 μW/cm², and 1.74 ± 0.10 μW/cm², were measured for the TENG 1, TENG 2, TENG 3 and TENG 4, respectively. The performance of the e-Gear selector showcased the potential of the TENG energy harvesting method for integration into the automotive industry, aligning with the rapid advancements in electric vehicle (EV) applications. This technology is particularly promising for future gear selector designs, as it eliminates the need for external power supplies, reduces cost, minimizes wiring, and offers greater flexibility in positioning within the vehicle.


  • Open Access

    Intelligent Detection of Adventitious Sounds Critical in Diagnosing Cardiovascular and Cardiopulmonary Diseases

    by Xingzhe Zhang, Dinesh Maddipatla, Binu B. Narakathu, Bradley J. Bazuin, Massood Z. Atashbar

    A Multi-Channel Stethograph System (STG system) was designed and developed as an electronic auscultation system for recording heart, lung, and trachea sounds non-invasively through an acoustic sensor array. The STG system consists of 16 acoustic sensors, a signal conditioning board, and a data logger (data acquisition, wireless transmission, sound visualization). The STG system captures breath with any adventitious sound event in 16 locations simultaneously to maximize the information of the specific sound event (for example, detection of the origin of mother adventitious sound and extracting its features), when compared with a single-channel stethoscope. This system can be an efficient tool to aid doctors or physicians in analyzing the adventitious sound from respiration diseases. However, it still requires the need for an experienced doctor or physician in the diagnosis and validation of adventitious sound. This paper presents a computerized method with an intelligent algorithm for detecting various adventitious sounds that are the key characteristics of cardiopulmonary diseases (CD) and assists the doctor/physician in the continuous diagnosis of lungs, which potentially can be beneficial during the COVID-19 progression. The proposed algorithm was able to detect breath patterns using trachea sound; location of the mother adventitious event using lung sounds (14 channels); determine the type of adventitious sound by correlating lung sound with trachea sound. The algorithm consists of breath pattern detection, candidate audio selection, breath pattern extraction, and adventitious sound detection. Digital signal processing techniques such as filtering, windowing, enveloping, discrete Fourier transform, and thresholds were used for identifying and classifying the inhalation and exhalation patterns in the lung sound in an independent (automatic) and intelligent way. The auscultation diagnosis algorithm can identify and distinguish discontinuous adventitious sounds which include wheeze, rhonchi, wheeze & rhonchi, and squawk, with an accuracy of 96.9%, 95.3%, 90%, and 100%. The algorithm was able to fully utilize the advantage of the multichannel system to simultaneously detect breath patterns, types of adventitious sound, and the location of the mother adventitious event that other algorithms cannot achieve. It has the potential to aid doctors/physicians in the early detection and monitoring of any lung disorders by providing objective evidence on adventitious sounds.


  • Laser Patterned Flexible Cathode with Low Tortuosity for Fast Charging Lithium-Ion Battery Applications

    by H. R. K. M. Emani, V. Palaniappan, D. Maddipatla, G. Hajimazdarani, B. J. Bazuin, M. Z. Atashbar

    Fabricating electrodes with low tortuosity and fast charging capabilities is pivotal for advancing the field of electric vehicles. A cathode ink was prepared using NMC 811 (LiNi 0.8 Co 0.l Mn 0.l O 2 ) as active material alongside carbon black as conductive additive, polyvinylidene fluoride (PVDF) as binder and n-methyl-2-pyrrolidone (NMP) as solvent. The cathodes were fabricated by bar-coating the ink on an aluminum foil, which acts as a current collector. Laser patterning was performed to introduce structured pore networks (SPNs) into the cathode with a pore diameter of 80 $\mu \mathrm{m}$ and edge-to-edge distance (ETE) of 75 $\mu\mathrm{m}$ between the pores. The significance of the structured electrode was investigated by conducting electrochemical tests on the coin-cells assembled with and without SPNs at high mass loadings of approximately 14 $\text{mg}/\text{cm}^{2}$ . The cathode with SPNs exhibited superior capacity of 134 mAh/g compared to the capacity of control bar-coated electrode (without SPNs) 93 mAh/g at highest C-rate of 6C. The structured electrode also displayed excellent capacity retention of 99% at the end of rate test. The improvement in the performance of cells is due to the reduction in tortuosity resulted from laser patterned SPNs in the cathode.


  • A Novel and Flexible Laser Patterned Graphene Nanoplatelet Electrode With SPNs for Fast Charging Lithium-Ion Batteries

    by Himanaga Rama Krishna Manoj Emani, Valliammai Palaniappan, Dinesh Maddipatla, Xingzhe Zhang, Bradley J. Bazuin, Massood Z. Atashbar

    A flexible anode was developed with graphene nanoplatelet (xGnP) as the anode material for fabricating fast charging lithium-ion battery. The ink consists of graphene nanoplatelets as active material along with C-45 carbon black as conductive additive and polyvinylidene fluoride (PVDF) as binder. The ink was bar coated on to two flexible copper films to form anodes with mass loadings of 2.8 mg/cm 2 and 7.2 mg/cm 2 . Then the anode was laser patterned to introduce secondary pore network (SPN) consisting of pores with a diameter of ~33 μm and an edge-to-edge distance of ~42 μm between the pores. The mass loadings of laser patterned anodes were measured to be 2.1 mg/cm 2 and 5.6 mg/cm 2 . Half-cell lithium-ion batteries was assembled with fabricated anodes with lithium metal foil as counter electrode. Ethylene carbonate and dimethyl carbonate (EC: DEC) in 50/50 (v/v) mixed with 1M lithium hexafluorophosphate (LiPF 6 ) was used as electrolyte in assembled coin-cells. Formation, rate and cycling tests were performed for bar-coated (without SPN) and laser patterned (with SPN) cells with different mass loadings at different C-rates. Cells with SPNs exhibited higher specific capacities of 420 mAh/g, 315 mAh/g and 207 mAh/g at high mass loading, at fast charging C-rates of 2C, 4C and 6C, respectively. Cells with SPNs showed superior capacity retention close to 90% when compared to cells without SPNs (38%) after 200 cycles at 2C-rate. Effect of SPN’s was significantly evident during rate and cycling performance of anodes at high mass loading. This study demonstrated the significance of implementing SPNs in the electrodes for achieving fast charging lithium-ion batteries with high mass loading.


  • Triboelectric Nanogenerators (TENGs) Based on Various Flexible Polymeric Materials Along With Printed and Non-Printed Electrodes

    by Sam Ali, Valliammai Palaniappan, Dinesh Maddipatla, Masoud Panahi, Bradley J. Bazuin, Massood Z. Atashbar

    Four designs (D1-D4) of flexible triboelectric nanogenerators (TENGs) were successfully fabricated in three different configurations for energy harvesting applications. Typically, TENG consists of anode layer, cathode layer, and electrodes. Combination of materials were investigated in this study using polyethylene terephthalate (PET), thermoplastic polyurethane (TPU) and a flexible fabric as top triboelectric (cathode) layers; Kapton and polydimethylsiloxane (PDMS) as bottom triboelectric (anode) layers. Copper (Cu) tape and screen-printed silver (Ag) were used as electrodes. Each of these designs (D1-D4) has three configurations C1, C2 and C3 in which the top substrate (cathode layer) was different from one configuration to other. In order to determine the best material combination that would provide better TENG performance, different configurations were considered. The capability of the TENGs in terms of open circuit voltage (V oc ) and short circuit current (I sc ) were demonstrated by subjecting them to ~5 to 6 N force at 10 Hz operating frequency. A maximum V oc of 21.61 ± 2.27 V pp , 35.32 ± 0.89 V pp , 31.21 ± 1.43 V pp and 45.75 ± 5.09 V pp resulted in a power density of 0.29 μW/cm², 1.12 μW/cm², 0.47 μW/cm² and 0.91 μW/cm² from the D1, D2, D3 and D4 designs, respectively. The TENG fabricated using screen printed Ag flake on PDMS and fabric (D4) exhibited the highest open circuit output and a good repeatability after six months of re-testing with a maximum difference of ~ 7.39 % change(ΔV/V) in the output signal. In addition, a cyclic test was performed on D4, the results obtained demonstrate a good durability of the TENG sensor over 1000 cycles. The fabricated TENG device has a simple design, compact size, and demonstrated a better performance in comparison with some of the other works in terms of output voltage.


  • A new method for ensemble combination based on adaptive decision making

    by Mohammed Falih Hassan, Ikhlas Abdel-Qader, Bradley Bazuin


  • Development of a Flexible Wireless ECG Monitoring Device With Dry Fabric Electrodes for Wearable Applications

    by Simin Masihi, Masoud Panahi, Dinesh Maddipatla, Anthony J. Hanson, Stephen Fenech, Lucas Bonek, Nicholas Sapoznik, Paul D. Fleming, Bradley J. Bazuin, Massood Z. Atashbar

    A flexible wireless electrocardiogram (ECG) device, integrated with fabric was fabricated for monitoring physiological signals in wearable biomedical applications. The ECG device consists of dry electrodes and a readout module. The dry electrode was fabricated by depositing multi-walled carbon nanotube (MWCNTs)/polydimethyl-siloxane (PDMS) composite on a thermoplastic polyurethane (TPU) substrate with screen printed silver (Ag) layer. The readout module with wireless data transmission capability was designed and fabricated on a flexible polyimide substrate. The ECG device was attached to fabric, and its performance was investigated by measuring the ECG signals and comparing them with the results of conventional wet Ag/AgCl electrode. It was observed that the device demonstrated similar performance in terms of signal intensity and correlation when compared to the conventional wet ECG electrodes. Signal-to-noise-ratio (SNR) analysis clearly showed that the dry electrodes with an average SNR of 23.1 dB, perform better than the commercially available Ag/AgCl electrodes (SNR of 21.2 dB). In addition, the capability of the fabric based dry electrodes to measure ECG signals during the physiological activities under exercise motions was studied. This enabled understanding the effect of motion artifacts on the dry electrode response and allowed comparing the obtained ECG signals with the responses of conventional wet ECG electrodes (subjected to similar conditions). It was observed that, even though dry electrodes didn’t use any kind of adhesive gel for measuring the ECG signals, they performed very similar to conventional wet electrodes. The results obtained clearly demonstrated the feasibility of employing fabric based flexible dry ECG electrodes for continuous monitoring of ECG signals in health care applications and can potentially replace the wet electrodes.


  • Open Access

    Development of a Novel Wireless Multi-Channel Stethograph System for Monitoring Cardiovascular and Cardiopulmonary Diseases

    by Xingzhe Zhang, Dinesh Maddipatla, Binu B. Narakathu, Bradley J. Bazuin, Massood Z. Atashbar

    A multi-channel stethograph system was designed and developed as an electronic auscultation system for graphic recording of heart, lung, and trachea (HLT) sounds non-invasively through a set of 16 acoustic sensors. The multi-channel stethograph system was fabricated by placing 16 microphone based acoustic sensor in a CNC machined DelrinⓇhousing cases that are covered using diaphragms. Among the 16 acoustic sensors, 14 were positioned in a memory foam pad, and two were placed directly on the heart and trachea to acquire sounds simultaneously from the lungs, heart, and trachea. The sounds acquired from the 16 acoustic sensors were processed through a custom designed and fabricated 16-channel PCB for signal conditioning. A National Instruments (NI) 9205 data acquisition device (DAQ) along with a NI 9191 wireless chassis was used to acquire and wirelessly transmit the data from the 16-channel PCB to a Wi-Fi enabled device such as a PC/tablet. A custom LabVIEW program was developed on a Wi-Fi enabled PC/tablet to record the data from the DAQ. In addition, a MATLAB program was developed to convert the recorded data from the acoustic sensors into 16 audio files (for audio playback) and plot the waveforms in time and frequency domain as well as spectrogram for visual examination of any abnormal patterns in inhalation and exhalation. This provides critical information on the presence of crackles, rhonchi and wheeze sounds as well as abnormal heartbeat and respiration rate which helps in analyzing the condition of heart and lungs. The graphically displayed HLT sounds will help physicians in the clinical diagnosis and monitoring of lung and heart disorders, particularly chronic obstructive pulmonary disease (COPD), asthma, pneumonia, and congestive heart failure by providing objective evidence.