Michal Kostelansky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michal Kostelansky has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jan Nedoma
Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSB—Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic
3 shared publications - Marcel Fajkus
Department of Telecommunications, Faculty of Electrical Engineering and Computer Science, VSBTechnical University of Ostrava, Ostrava, Czech Republic
3 shared publications - Radek Martinek
Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
3 shared publications - Jindrich Brablik
Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB–Technical University of Ostrava, Ostrava, Czechia
2 shared publications - Khosrow Behbehani
Department of Bioengineering, University of Texas at Arlington, Arlington, TX, USA
2 shared publications - Mazin Abed Mohammed
College of Computer Science and Information Technology, University of Anbar, Anbar, Iraq
2 shared publications
Latest Publications
- Open Access
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 57150-57162
FBG Sensor for Heart Rate Monitoring Using 3D Printing Technology
Currently, the use of fiber-optic Bragg gratings in biomedical applications, especially in the field of magnetic resonance imaging (MRI), is becoming popular. In these applications, the fiber Bragg grating (FBG) encapsulation plays a crucial role in terms of the accuracy and reproducibility of the measurements. This paper describes in detail the fabrication method of a prototype FBG sensor, which is realized by encapsulating a Bragg grating between two layers of the MR-compatible material Acrylonitrile Butadiene Styrene (ABS) by 3D printing. The sensor thus created, implemented, for example, on the chest of a human body, enables monitoring of the vital functions of the human body. The paper describes the complete procedure for the creation of the prototype sensor, including strain and temperature dependence, as well as results of long-term experimental measurements against the conventional electrocardiography (ECG) standard. Results based on the objective Bland-Altman (B-A) method confirm that the implemented sensor can be used for reliable monitoring of cardiac activity (>95% based on B-A). Taking into account the single fiber optic cable, its simple implementation, its small size and weight < 5g, the presented sensor represents an interesting alternative to conventional ECG.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 57150-57162
Open AccessFBG Sensor for Heart Rate Monitoring Using 3D Printing Technology
Currently, the use of fiber-optic Bragg gratings in biomedical applications, especially in the field of magnetic resonance imaging (MRI), is becoming popular. In these applications, the fiber Bragg grating (FBG) encapsulation plays a crucial role in terms of the accuracy and reproducibility of the measurements. This paper describes in detail the fabrication method of a prototype FBG sensor, which is realized by encapsulating a Bragg grating between two layers of the MR-compatible material Acrylonitrile Butadiene Styrene (ABS) by 3D printing. The sensor thus created, implemented, for example, on the chest of a human body, enables monitoring of the vital functions of the human body. The paper describes the complete procedure for the creation of the prototype sensor, including strain and temperature dependence, as well as results of long-term experimental measurements against the conventional electrocardiography (ECG) standard. Results based on the objective Bland-Altman (B-A) method confirm that the implemented sensor can be used for reliable monitoring of cardiac activity (>95% based on B-A). Taking into account the single fiber optic cable, its simple implementation, its small size and weight < 5g, the presented sensor represents an interesting alternative to conventional ECG.
- 20 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
Fiber-Optic Breathing Mask: An Alternative Solution for MRI Respiratory Triggering
This article provides the outcomes of complex testing of a novel low-cost and safe breathing sensor using fiber-optic technology under real magnetic resonance (MR) examination at 3 T. The sensor consists of the Bragg grating embedded into an oxygen breathing mask [i.e., fiber-optic breathing mask (FOBM)], thus minimizing movement artifacts and preventing MR interference. The obtained triggered MR images were evaluated using both objective and subjective image analysis methods, such as signal-to-noise ratio, contrast-noise ratio, and the analysis performed by radiologists. The system was compared with Siemens Prisma Respiratory Reference based on the navigator technique and pneumatic respiratory belt. Image quality assessment provided by radiologist experts shows that the FOBM approach provides reliable and accurate results since the overall image quality reached an average score of 3.3 ± 0.4, 3.7 ± 0.5, and 3.8 ± 0.2 for FOBM, Siemens respiratory reference, and respiratory belts, respectively.
- 20 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
Fiber-Optic Breathing Mask: An Alternative Solution for MRI Respiratory Triggering
This article provides the outcomes of complex testing of a novel low-cost and safe breathing sensor using fiber-optic technology under real magnetic resonance (MR) examination at 3 T. The sensor consists of the Bragg grating embedded into an oxygen breathing mask [i.e., fiber-optic breathing mask (FOBM)], thus minimizing movement artifacts and preventing MR interference. The obtained triggered MR images were evaluated using both objective and subjective image analysis methods, such as signal-to-noise ratio, contrast-noise ratio, and the analysis performed by radiologists. The system was compared with Siemens Prisma Respiratory Reference based on the navigator technique and pneumatic respiratory belt. Image quality assessment provided by radiologist experts shows that the FOBM approach provides reliable and accurate results since the overall image quality reached an average score of 3.3 ± 0.4, 3.7 ± 0.5, and 3.8 ± 0.2 for FOBM, Siemens respiratory reference, and respiratory belts, respectively.
- Open Access
- 1 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 181205-181223
A Novel FBG-Based Triggering System for Cardiac MR Imaging at 3 Tesla: A Pilot Pre-Clinical Study
This first-ever study demonstrates the applicability of a fiber Bragg grating (FBG) system for MR cardiac triggering of cardiovascular magnetic resonance at 3 Tesla. The unique patented system senses body movements caused by cardiac activity using a non-invasive ballistocardiography (BCG) sensor. The pilot research compares a novel FBG-based system with clinically used triggering systems based on electrocardiography (ECG) and pulse oximetry (POX). The pilot pre-clinical study was conducted on 8 subjects at a Siemens Prisma 3T MR Scanner. The study compares images from two basic cardiac sequences, TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery), using objective methods and subjective evaluation by clinical experts. The study presents original results that confirm the applicability of optical sensors in the field of cardiac triggering having a number of advantages in comparison to conventional solutions, such as no eddy current interference, ease of placement of the sensor on the patient’s body, and senor reusability. The proposed FBG-based system achieves comparable results with the most frequently used and most accurate ECG-based and POX-based clinical systems. In terms of subjective evaluation by experts, the FBG system outperformed the POX-based system used in clinical practice.
- 1 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 181205-181223
Open AccessA Novel FBG-Based Triggering System for Cardiac MR Imaging at 3 Tesla: A Pilot Pre-Clinical Study
This first-ever study demonstrates the applicability of a fiber Bragg grating (FBG) system for MR cardiac triggering of cardiovascular magnetic resonance at 3 Tesla. The unique patented system senses body movements caused by cardiac activity using a non-invasive ballistocardiography (BCG) sensor. The pilot research compares a novel FBG-based system with clinically used triggering systems based on electrocardiography (ECG) and pulse oximetry (POX). The pilot pre-clinical study was conducted on 8 subjects at a Siemens Prisma 3T MR Scanner. The study compares images from two basic cardiac sequences, TRUE FISP (Free Induction Decay Steady-State Precession) and PSIR (Phase Sensitive Inversion Recovery), using objective methods and subjective evaluation by clinical experts. The study presents original results that confirm the applicability of optical sensors in the field of cardiac triggering having a number of advantages in comparison to conventional solutions, such as no eddy current interference, ease of placement of the sensor on the patient’s body, and senor reusability. The proposed FBG-based system achieves comparable results with the most frequently used and most accurate ECG-based and POX-based clinical systems. In terms of subjective evaluation by experts, the FBG system outperformed the POX-based system used in clinical practice.