MZMeng Zhang

Meng Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Meng Zhang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Intensity-Modulated Fiber-Optic Strain Sensor Using Multimode Fiber and Microfiber Joint-Assisted Micro-Cavity Interferometer

    by Hui Zhang, Jing Kang, Meng Zhang, Chuanxu Liu, Jiuru Yang

    In this paper, a novel micro-cavity based Mach-Zehnder interferometer is proposed by joint-assistance of microfiber and multimode fiber (MMF). The light field distribution is comprehensively investigated, and the quantitative beam expansion range and the length of MMF are obtained. Under the optimized fabrication parameters, a joint-assisted micro-cavity structure is experimentally completed and the axial strain tests are performed. The experimental results show that obvious intensity responses of fringes are exhibited in the range from 0 to $300~ {\mu \varepsilon }$ , but with gradually reduced wavelength sensitivities. It is found that a near-zero wavelength drift exists in the fringe of 1589.83 nm with the intensity sensitivity of ~0.02 dB/ ${\mu \varepsilon }$ . Besides, the corresponding temperature response is −81 pm/°C with a slight fluctuation of ~0.003 dB/°C. Such high discrimination between axial strain and temperature brings $\sim 0.5~ {\mu \varepsilon }$ detection resolution and ultra-low temperature crosstalk ( $\sim 0.15~ {\mu \varepsilon }/^{ {\circ }}\text{C}$ ), simultaneously. With the merits of high sensitivity and practicality, our sensor is very promising and potential in high-precision axial-strain related engineering monitoring and sensing.


  • Self-Temperature Compensated Fiber-Optic Liquid Level Sensor With Ultra-Long Linear Range Using Quasi-Single Modal Interferometer

    by Huaicheng Zhang, Hui Zhang, Liangtao Hou, Meng Zhang, Jiuru Yang

    In this paper, a thin-core fiber based in-line Mach-Zehnder interferometer is proposed and experimentally completed through symmetric core-offset splicing technique. The light field distribution of fundamental and cladding modes is investigated with varied core-offset and the state of quasi-single modal interference (QS-MI) is attained. The comprehensive tests under QS-MI state are then conducted and compared in term of liquid level sensing. Experimental results show that significant linearity- improvement is achieved in the range from 0 to 500 mm, and the responses of liquid level reach 101 pm/mm (short-range within 20-mm) and 41.8 pm/cm (long-range within 50-cm), respectively. Also owing to high response consistency, the temperature crosstalk is eliminated by means of self-differential compensation and the measured error is compressed within 0.68%. Furthermore, $\sim 16$ -fold enhancement of detection limit at least is gained through building a fiber ring-cavity laser based active sensing system. It is the first time that the issues of linearity and temperature crosstalk are simultaneously overcome in the continuous long-range liquid level measurement. With the merits of low-cost, large-scale and ease of fabrication, our scheme is very practical and promising in the engineering and applications related to liquid level sensing.


  • High Sensitivity Fiber-Optic Strain Sensor Based on Modified Microfiber-Assisted Open-Cavity Mach-Zehnder Interferometer

    by Hui Zhang, Meng Zhang, Jing Kang, Xudong Zhang, Jiuru Yang

    In this paper, a modified microfiber-assisted open- cavity (MMA-OC) structure is proposed by introducing two pieces of multimode fiber and a novel sub-millimeter in-line Mach-Zehnder interferometer is theoretically and experimentally completed. The cavity-length dependence of MMA-OC on axial strain sensing is characterized and the comprehensive strain tests are conducted under an optimal waist diameter. The experimental results show that the selective intensity-/wavelength- modulated strain response can be achieved by varying the cavity length. For a shorter cavity length, MMA-OC presents more than 20-dB intensity variation and near-zero wavelength drift. But an apparent and flat red-shift of fringes occurs in the structure with >1000-μm cavity length. Moreover, due to inverse feature of temperature response, the calculated cross-sensitivity is merely 0.106 μϵ/°C. And the detection resolution up to ~0.2 μϵ is gained when the cavity length is equal to 503 μm, with the measurement error of ±0.021 μϵ. Our sensor with the merits of compactness, low-cost and ease of fabrication is very promising for high-precision engineering monitoring and sensing.


  • Open Access

    Composite Modal Interferometer for Simultaneous Triple-Parameter Measurement Based on Cascaded No-Cladding Fiber and Thin-Core Fiber Structure

    by Meng Zhang, Liangtao Hou, Hui Zhang, Xudong Zhang, Jiuru Yang

    In this paper, an in-fiber composite modal interferometer (CMI) is proposed and experimentally demonstrated based on cascaded no-cladding fiber (NCF) and thin-core fiber (TCF) structure, which respectively corresponds to multimode interferometer (MMI) and Mach-Zehnder interferometer (MZI). The self-image effect of MMI is deeply analyzed and the interference fringes distribution of CMI is accurately designed by the selective the length of NCF and TCF. The comprehensive tests are then conducted and the experimental results show that interference fringes present similar temperature response but the apparent differences in strain and refractive index (RI) tests owing to the asymmetrical structure. MMI has a near-zero intensity sensitivity of strain and red-shifts with the increased RI. But MZI has the sensitivity of –19.3nm/RIU and a 4.94 dB increment in the range of 300–1100 με. Thus high-discrimination simultaneous triple-parameter measurement is achieved by means of joint wavelength and intensity demodulation. The proposed CMI has the merits of high sensitivity, low cost and ease of fabrication, and is very promising and potential for the engineering monitoring and sensing applications.