Bikram Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bikram Das has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Prabir Ranjan Kasari
Department of Electrical Engineering, National Institute of Technology Agartala, Agartala, Tripura 799046, India
8 shared publications - Abanishwar Chakrabarti
Electrical Engineering Department, NIT, Agartala, India
7 shared publications - Sujit K. Biswas
Jadavpur University
4 shared publications Abanishwar Chakraborti
Department of Electrical Engineering, National Institute of Technology, Agartala, Agartala, India
2 shared publications- Apurva Verma
Electrical Engineering, IIT Delhi, 28817 New Delhi, Delhi, India
2 shared publications - Koustuv Sarkar
Department of Electrical Engineering, St. Thomas College of Engineering and Technology, Kolkata, India
2 shared publications
Latest Publications
- 1 November 2025
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 18 (9) , 1-19
Multilevel Inverters: An Exploration of Topologies, Advantages, and Limitations
It presents a thorough analysis of Multilevel Inverter (MLI) topologies. The standard two-level converters are expensive, heavy, and cause substantial switching loss in order to obtain the sinusoidal output waveform. This is due to the requirement of the filter circuit. Multilevel Inverter topologies are becoming increasingly popular in power electronics inverters as a solution to this issue in recent years. The Multilevel Inverter configuration, which generates output voltage in more than two levels to get the stepped voltage minimizing total harmonic distortion (THD) and lowering switching frequencies, eliminates the need for bulky transformers and filter circuits. To assess the inverter efficiency, the optimal output voltage with less harmonic content requires the correct switching mechanism. In order to achieve excellent power quality and minimal switching loss, the power consumption must also be taken into consideration while choosing the topology and control method. However, because separate gate drivers are used for the switching components, it is vital to reduce count of semiconductors because this increases the complexity of the circuit. The advantages, disadvantages, and applications of MLI topologies are deliberated in this work.
- 1 November 2025
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 18 (9) , 1-19
Multilevel Inverters: An Exploration of Topologies, Advantages, and Limitations
It presents a thorough analysis of Multilevel Inverter (MLI) topologies. The standard two-level converters are expensive, heavy, and cause substantial switching loss in order to obtain the sinusoidal output waveform. This is due to the requirement of the filter circuit. Multilevel Inverter topologies are becoming increasingly popular in power electronics inverters as a solution to this issue in recent years. The Multilevel Inverter configuration, which generates output voltage in more than two levels to get the stepped voltage minimizing total harmonic distortion (THD) and lowering switching frequencies, eliminates the need for bulky transformers and filter circuits. To assess the inverter efficiency, the optimal output voltage with less harmonic content requires the correct switching mechanism. In order to achieve excellent power quality and minimal switching loss, the power consumption must also be taken into consideration while choosing the topology and control method. However, because separate gate drivers are used for the switching components, it is vital to reduce count of semiconductors because this increases the complexity of the circuit. The advantages, disadvantages, and applications of MLI topologies are deliberated in this work.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2093-2102
Negative Sequence Current Injection Based Active Islanding Detection Method
This article presents a fast and accurate active islanding detection scheme for a grid-tied voltage source inverter (VSI). In the proposed scheme, the VSI generates a small negative sequence voltage to continuously inject a small negative sequence current into the system. The voltage at the point of common coupling (PCC) is measured and the negative sequence component of PCC voltage is extracted. The negative sequence voltage generated by the VSI and the negative sequence voltage at PCC are combined to yield a time-invariant coefficient, which is proposed here to be used for islanding detection. In case detection is done solely based on the magnitude of negative sequence voltage at PCC, higher threshold has to be set as a small magnitude of negative sequence voltage at PCC may also be present due to grid unbalance and other transient events. In the proposed scheme, the islanding detection coefficient depends on the similarity between the injected and measured negative sequence voltage and hence is not dependent on the absolute magnitude of the negative sequence voltage. Thus a very low magnitude of negative sequence current can be injected to effectively detect islanding conditions without a significant impact on power quality. Simulation results show that the proposed scheme is effective for unbalanced grid voltage, or unbalanced load, even in the presence of noise in acquired data. Experimental studies on a laboratory prototype validate the performance of the proposed islanding detection scheme.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2093-2102
Negative Sequence Current Injection Based Active Islanding Detection Method
This article presents a fast and accurate active islanding detection scheme for a grid-tied voltage source inverter (VSI). In the proposed scheme, the VSI generates a small negative sequence voltage to continuously inject a small negative sequence current into the system. The voltage at the point of common coupling (PCC) is measured and the negative sequence component of PCC voltage is extracted. The negative sequence voltage generated by the VSI and the negative sequence voltage at PCC are combined to yield a time-invariant coefficient, which is proposed here to be used for islanding detection. In case detection is done solely based on the magnitude of negative sequence voltage at PCC, higher threshold has to be set as a small magnitude of negative sequence voltage at PCC may also be present due to grid unbalance and other transient events. In the proposed scheme, the islanding detection coefficient depends on the similarity between the injected and measured negative sequence voltage and hence is not dependent on the absolute magnitude of the negative sequence voltage. Thus a very low magnitude of negative sequence current can be injected to effectively detect islanding conditions without a significant impact on power quality. Simulation results show that the proposed scheme is effective for unbalanced grid voltage, or unbalanced load, even in the presence of noise in acquired data. Experimental studies on a laboratory prototype validate the performance of the proposed islanding detection scheme.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3242 (1) , 050004
A comprehensive review of optimization techniques for power quality improvement using multilevel inverters
Poor power quality is a major concern in power system, which can lead to equipment damage, power interruptions, and safety hazards. In modern days, due to non-l Poor power quality is a major concern in power system, which can lead to equipment damage, power interruptions, and safety hazards. In modern days, due to non-l
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3242 (1) , 050004
A comprehensive review of optimization techniques for power quality improvement using multilevel inverters
Poor power quality is a major concern in power system, which can lead to equipment damage, power interruptions, and safety hazards. In modern days, due to non-l Poor power quality is a major concern in power system, which can lead to equipment damage, power interruptions, and safety hazards. In modern days, due to non-l
- 29 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 6336-6347
Performance Improved Multi-Level OEIM Drive With Voltage Boost Through Unequal Levels
This article proposes an energy efficient 5-level neutral point clamped (NPC) inverter based boost inverter topology for transformer-less medium voltage high power Open End Induction Motor (OEIM) drive. A conventional boost circuit cannot be used in such drives as single semiconductor device may not be able to block the total dc link voltage and simultaneously carry full load current. In the proposed scheme, two partly rated soft switched isolated dc-dc converters which generate only the required boost fraction of the voltage are connected in cascade with the two ends of the input dc bus. The input dc is divided into two equal parts using a capacitor voltage divider circuit. These four effective voltage sources in cascade serve as the four dc bus for the two five level NPC VSI of the OEIM drive. A substantial amount of power directly flows to the inverter through the capacitor voltage divider circuit and hence the size as well as power loss of the dc-dc converter of the proposed scheme is much smaller. The voltage generated from the dc-dc converter is lower than the voltage in the capacitor voltage divider circuit, creating unequal step heights in the pole voltage of the 5-level NPC VSI. These unequal steps in the pole voltage of the two VSI of open end drive restrict the use of existing technique for operating an OEIM drive from a single dc source. In this article, a carrier based PWM technique is proposed to restrict the circulating current caused by CMV even when the voltage steps are unequal.
- 29 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 6336-6347
Performance Improved Multi-Level OEIM Drive With Voltage Boost Through Unequal Levels
This article proposes an energy efficient 5-level neutral point clamped (NPC) inverter based boost inverter topology for transformer-less medium voltage high power Open End Induction Motor (OEIM) drive. A conventional boost circuit cannot be used in such drives as single semiconductor device may not be able to block the total dc link voltage and simultaneously carry full load current. In the proposed scheme, two partly rated soft switched isolated dc-dc converters which generate only the required boost fraction of the voltage are connected in cascade with the two ends of the input dc bus. The input dc is divided into two equal parts using a capacitor voltage divider circuit. These four effective voltage sources in cascade serve as the four dc bus for the two five level NPC VSI of the OEIM drive. A substantial amount of power directly flows to the inverter through the capacitor voltage divider circuit and hence the size as well as power loss of the dc-dc converter of the proposed scheme is much smaller. The voltage generated from the dc-dc converter is lower than the voltage in the capacitor voltage divider circuit, creating unequal step heights in the pole voltage of the 5-level NPC VSI. These unequal steps in the pole voltage of the two VSI of open end drive restrict the use of existing technique for operating an OEIM drive from a single dc source. In this article, a carrier based PWM technique is proposed to restrict the circulating current caused by CMV even when the voltage steps are unequal.
- 12 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (2) , 1997-2006
A Fault-Tolerant Control Scheme of Grid Connected VSI for Balanced Power Injection
A retrofit solution is proposed in this article for providing fault-tolerant capability in the existing three-leg grid synchronized converter operating at unity displacement factor, during open circuit fault of one of its phases. During such a fault, the scheme controls the current in the two operative phases of the converter for equal magnitude with a mutual phase shift of 60°. This 60° phase-shifted two-phase current is distributed as a balanced three-phase grid current at unity displacement factor, using an existing Δ-Y isolation transformer or a lower power-rated zig-zag autotransformer. Existing fault-tolerant schemes are applicable only if the device or its driver fails, with the addition of hardware in the form of the redundant leg for the total failure of one phase of the converter. In retrofit application, the proposed scheme modifies the control logic and does not require modification in the controller hardware circuit or addition of a leg in the converter power circuit. Hence, it can be conveniently implemented to add fault-tolerant capability to an existing three-leg voltage source converter in either an inversion or rectification mode of operation. In addition to semiconductor failure, the proposed scheme is applicable during an open-circuit fault in other parts of the circuit viz., line reactor, connecting wire, transformer, etc., which is not possible using the existing fault-tolerant techniques. Simulation and experimental results are provided to validate the proposed concept.
- 12 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (2) , 1997-2006
A Fault-Tolerant Control Scheme of Grid Connected VSI for Balanced Power Injection
A retrofit solution is proposed in this article for providing fault-tolerant capability in the existing three-leg grid synchronized converter operating at unity displacement factor, during open circuit fault of one of its phases. During such a fault, the scheme controls the current in the two operative phases of the converter for equal magnitude with a mutual phase shift of 60°. This 60° phase-shifted two-phase current is distributed as a balanced three-phase grid current at unity displacement factor, using an existing Δ-Y isolation transformer or a lower power-rated zig-zag autotransformer. Existing fault-tolerant schemes are applicable only if the device or its driver fails, with the addition of hardware in the form of the redundant leg for the total failure of one phase of the converter. In retrofit application, the proposed scheme modifies the control logic and does not require modification in the controller hardware circuit or addition of a leg in the converter power circuit. Hence, it can be conveniently implemented to add fault-tolerant capability to an existing three-leg voltage source converter in either an inversion or rectification mode of operation. In addition to semiconductor failure, the proposed scheme is applicable during an open-circuit fault in other parts of the circuit viz., line reactor, connecting wire, transformer, etc., which is not possible using the existing fault-tolerant techniques. Simulation and experimental results are provided to validate the proposed concept.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (9) , 8666-8675
A CB-PWM Technique for Eliminating CMV in Multilevel Multiphase VSI
A generalized Carrier-Based Pulse Width Modulation (CB-PWM) scheme is proposed here for the elimination of common-mode voltage (CMV) in a multilevel multiphase voltage source inverter (VSI). In this CB-PWM scheme, the switching function of x-level, q-phase VSI is obtained from the switching function of virtual y-level and (y+1) level, q-phase VSI, where y = (x+1)/2 when x is odd and y = x/2 when x is even. It is established here that the pole voltages of q-phase x-level VSI thus obtained generate zero CMV. The proposed CB-PWM technique is computationally less intensive and hence can be easily implemented in hardware. Extensive simulation and experimental results are presented to validate the proposed CMV elimination technique in 3-phase 7-level VSI, 5-phase 5-level VSI, and 6-phase 4-level VSI. A comparative study of the proposed PWM scheme with the existing technique shows the superiority of the proposed technique in eliminating CMV.
- 3 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (9) , 8666-8675
A CB-PWM Technique for Eliminating CMV in Multilevel Multiphase VSI
A generalized Carrier-Based Pulse Width Modulation (CB-PWM) scheme is proposed here for the elimination of common-mode voltage (CMV) in a multilevel multiphase voltage source inverter (VSI). In this CB-PWM scheme, the switching function of x-level, q-phase VSI is obtained from the switching function of virtual y-level and (y+1) level, q-phase VSI, where y = (x+1)/2 when x is odd and y = x/2 when x is even. It is established here that the pole voltages of q-phase x-level VSI thus obtained generate zero CMV. The proposed CB-PWM technique is computationally less intensive and hence can be easily implemented in hardware. Extensive simulation and experimental results are presented to validate the proposed CMV elimination technique in 3-phase 7-level VSI, 5-phase 5-level VSI, and 6-phase 4-level VSI. A comparative study of the proposed PWM scheme with the existing technique shows the superiority of the proposed technique in eliminating CMV.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 869-881
A New Grid Interactive 11-Level Hybrid Inverter Topology for Medium-Voltage Application
Multi-Level Inverters (MLI) has wide applications due to their numerous advantages. An improved configuration of eleven-level MLI suitable for medium voltage range has been proposed in this paper. The proposed topology contains two half-bridge sub-modules (HBSM), one flying capacitor (FC) MLI and one full bridge sub-module (FBSM). A simple method of capacitor voltages balancing (CVB) has been demonstrated with less ripple. The study about the effectiveness of proposed MLI has been justified by loss calculation to find efficiency and voltage ripple analysis of capacitor. The comparative assessment in terms of switch count, driver count, capacitor requirement, device peak inverse voltage (PIV), total standing voltage (TSVp.u), cost function etc. for developed hybrid inverter (HI) topology has been presented to establish the utility of the proposed HI. This topology has been checked for its operation under various operating conditions including frequency and modulation index (MI) variation, over-modulation range and also with motor load. The grid connectivity option of the proposed HI has been verified to ensure the suitability for application with renewables.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 869-881
A New Grid Interactive 11-Level Hybrid Inverter Topology for Medium-Voltage Application
Multi-Level Inverters (MLI) has wide applications due to their numerous advantages. An improved configuration of eleven-level MLI suitable for medium voltage range has been proposed in this paper. The proposed topology contains two half-bridge sub-modules (HBSM), one flying capacitor (FC) MLI and one full bridge sub-module (FBSM). A simple method of capacitor voltages balancing (CVB) has been demonstrated with less ripple. The study about the effectiveness of proposed MLI has been justified by loss calculation to find efficiency and voltage ripple analysis of capacitor. The comparative assessment in terms of switch count, driver count, capacitor requirement, device peak inverse voltage (PIV), total standing voltage (TSVp.u), cost function etc. for developed hybrid inverter (HI) topology has been presented to establish the utility of the proposed HI. This topology has been checked for its operation under various operating conditions including frequency and modulation index (MI) variation, over-modulation range and also with motor load. The grid connectivity option of the proposed HI has been verified to ensure the suitability for application with renewables.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 964-976
OCNOP Control of Grid-Connected Converters for Single-Phase Open Circuit Fault
An open circuit fault-tolerant operation of a grid connected inverter requires switching reconfigurations or redundant inverter leg to bypass the faulty device. Such measures led to increased cost and design complexities. In the absence of such reconfiguration mechanisms, a grid-connected inverter with an open-circuit fault in one of the inverter leg injects negative sequence current into the grid. The negative sequence current causes oscillation in DC-link voltage and thereby inject lower order harmonic into the grid. The present work proposes a novel control strategy (Open Circuit Non-Oscillatory Power- OCNOP) to deliver a steady power into a balanced three phase grid with only two active legs of the grid connected inverter. The current of these two active phases are controlled to be equal in magnitude and 60° phase apart. This inhibits the flow of negative sequence current and in turn limits the lower order harmonic injection within the permissible limit. A control strategy is also proposed to modify the power references during post fault operation so that the post fault current in two active phases are limited within the converter current rating. The performance of the proposed scheme is compared with the conventional vector control scheme through a simulation study. The simulation results for the proposed control scheme are verified through experimental study in a laboratory prototype.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (1) , 964-976
OCNOP Control of Grid-Connected Converters for Single-Phase Open Circuit Fault
An open circuit fault-tolerant operation of a grid connected inverter requires switching reconfigurations or redundant inverter leg to bypass the faulty device. Such measures led to increased cost and design complexities. In the absence of such reconfiguration mechanisms, a grid-connected inverter with an open-circuit fault in one of the inverter leg injects negative sequence current into the grid. The negative sequence current causes oscillation in DC-link voltage and thereby inject lower order harmonic into the grid. The present work proposes a novel control strategy (Open Circuit Non-Oscillatory Power- OCNOP) to deliver a steady power into a balanced three phase grid with only two active legs of the grid connected inverter. The current of these two active phases are controlled to be equal in magnitude and 60° phase apart. This inhibits the flow of negative sequence current and in turn limits the lower order harmonic injection within the permissible limit. A control strategy is also proposed to modify the power references during post fault operation so that the post fault current in two active phases are limited within the converter current rating. The performance of the proposed scheme is compared with the conventional vector control scheme through a simulation study. The simulation results for the proposed control scheme are verified through experimental study in a laboratory prototype.
- 8 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (6) , 6158-6173
TSBC Converter With BESS for DFIG-Based Wind Energy Conversion System
This paper proposes the integration of a battery energy storage system in a doubly-fed induction generator based wind energy conversion system. A modified triple star bridge cell converter is proposed for the control of doubly fed induction generator and battery energy storage system. The modular structure of the converter facilitates the integration of large energy storage using low rated converters. A median filter is used to segregate the fluctuating component of power generation because of wind speed variation. A control strategy is proposed to mitigate a part of this fluctuation within the rating of the battery energy storage system thereby reducing the fluctuation of power fed to the grid. Wind velocity at an interval of 30second is obtained from online resources and the performance of the proposed algorithm is evaluated via a simulation study. A wind turbine is emulated in a separately excited DC motor and the performance of the proposed scheme is experimentally validated in a laboratory prototype
- 8 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (6) , 6158-6173
TSBC Converter With BESS for DFIG-Based Wind Energy Conversion System
This paper proposes the integration of a battery energy storage system in a doubly-fed induction generator based wind energy conversion system. A modified triple star bridge cell converter is proposed for the control of doubly fed induction generator and battery energy storage system. The modular structure of the converter facilitates the integration of large energy storage using low rated converters. A median filter is used to segregate the fluctuating component of power generation because of wind speed variation. A control strategy is proposed to mitigate a part of this fluctuation within the rating of the battery energy storage system thereby reducing the fluctuation of power fed to the grid. Wind velocity at an interval of 30second is obtained from online resources and the performance of the proposed algorithm is evaluated via a simulation study. A wind turbine is emulated in a separately excited DC motor and the performance of the proposed scheme is experimentally validated in a laboratory prototype