Sameer Khandekar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sameer Khandekar has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
K. Muralidhar
7 shared publicationsAnkush Kumar Jaiswal
5 shared publications- Vyas Srinivasan
Indian Institute of Technology Kanpur
4 shared publications - Debartha Chatterjee
Indian Institute of Technology Kanpur, Kanpur, India
3 shared publications - Maneesh Punetha
Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, UP 208016, India
3 shared publications - Abhinav Bhanawat
Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur, UP 208016, India
2 shared publications
Latest Publications
- 7 December 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (50) , 18238-18251
Effect of Droplet-Laden Fibers on Aerodynamics of Fog Collection on Vertical Fiber Arrays
Growing population, along with rapid urbanization, has led to severe water scarcity, necessitating development of novel techniques to mitigate this looming problem. Fog contains water in the form of liquid droplets suspended in air, which can be collected on a porous structure placed in the path of the fog flow. We first develop an artificial fog-generating system using the thermodynamic principle of mixing of air streams followed by condensation, which closely mimics the liquid water content and droplet size distribution of natural fog. We then investigate how collected fog droplets growing on fiber surfaces alter the aerodynamics of fog flow across vertical fiber arrays, called harps, thus affecting their fog collection efficiency. As deposited droplets grow on the fiber surface, they increase the area occluded by droplet-laden fibers, thus increasing the effective shade coefficient (SCact), which increases with time from its initial geometric value (SCgeo), eventually reaching a quasi-steady state, as droplet shedding due to gravity and droplet growth due to fog collection balance each other. We find that this difference in the SCgeo and SCact is governed by local fiber geometry and its physico-chemical morphology; the process dynamics is captured by a nondimensional number, SC*, which increases with the length scale corresponding to the critical volume of droplet shedding relative to the fiber diameter, V*. Thus, there is a significantly greater increase in the effective shade coefficient for thin fibers having larger values of V* as compared to fibers with larger diameters which have lower V* values. On hydrophobic fibers, the quasi-steady state is achieved faster, and the time-averaged SCact is lower as compared to hydrophilic fibers due to the lower critical volume of droplet shedding. The shape of droplets growing on harp fibers affects the aerodynamics of fog flow, its inertial capture mechanism, and efficiency, which can guide design considerations for fog harps toward achieving optimal fog collection performance.
- 7 December 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (50) , 18238-18251
Effect of Droplet-Laden Fibers on Aerodynamics of Fog Collection on Vertical Fiber Arrays
Growing population, along with rapid urbanization, has led to severe water scarcity, necessitating development of novel techniques to mitigate this looming problem. Fog contains water in the form of liquid droplets suspended in air, which can be collected on a porous structure placed in the path of the fog flow. We first develop an artificial fog-generating system using the thermodynamic principle of mixing of air streams followed by condensation, which closely mimics the liquid water content and droplet size distribution of natural fog. We then investigate how collected fog droplets growing on fiber surfaces alter the aerodynamics of fog flow across vertical fiber arrays, called harps, thus affecting their fog collection efficiency. As deposited droplets grow on the fiber surface, they increase the area occluded by droplet-laden fibers, thus increasing the effective shade coefficient (SCact), which increases with time from its initial geometric value (SCgeo), eventually reaching a quasi-steady state, as droplet shedding due to gravity and droplet growth due to fog collection balance each other. We find that this difference in the SCgeo and SCact is governed by local fiber geometry and its physico-chemical morphology; the process dynamics is captured by a nondimensional number, SC*, which increases with the length scale corresponding to the critical volume of droplet shedding relative to the fiber diameter, V*. Thus, there is a significantly greater increase in the effective shade coefficient for thin fibers having larger values of V* as compared to fibers with larger diameters which have lower V* values. On hydrophobic fibers, the quasi-steady state is achieved faster, and the time-averaged SCact is lower as compared to hydrophilic fibers due to the lower critical volume of droplet shedding. The shape of droplets growing on harp fibers affects the aerodynamics of fog flow, its inertial capture mechanism, and efficiency, which can guide design considerations for fog harps toward achieving optimal fog collection performance.
- 15 July 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 193
Transient heat transfer during consecutive impact of two droplets on a heated substrate
- 15 July 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 193
Transient heat transfer during consecutive impact of two droplets on a heated substrate
- 14 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Hybrid Solar Simulator for Long-Term Testing of Photothermal Materials
Solar simulators are predominantly used for testing photovoltaic devices, which usually require a relatively shorter duration of exposure. Novel photothermal materials used for interfacial solar vapor generation utilizing the principle of heat localization, on the other hand, require a relatively much longer period of exposure and testing. This necessitates excellent stability for longer timescales, in addition to good spectrum distribution match and spatial uniformity of solar simulators. A hybrid LED-Halogen light source configuration for a solar simulator is proposed here which meets these requirements. An LED module (Phosphor coated blue LEDs, 100 W) producing warm white light is used as the primary light source, in conjunction with two commercially available Halogen lamps (50 W). The luminaire module performance in terms of spectrum distribution, intensity, effect of thermal management, interaction with neutral density filters and collimating lenses is investigated under different operating configurations. The assembled solar simulator is characterized based on spectrum distribution match, temporal instability, and spatial non-uniformity against global standards. Subsequently, an easily replicable photothermal fabric configuration is performance tested under the optimized solar simulator configuration, to evaluate its efficacy in terms of solar-to-vapor generation efficiency. The usefulness of the hybrid solar simulator system is established for long term testing as per the global standards.
- 14 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Hybrid Solar Simulator for Long-Term Testing of Photothermal Materials
Solar simulators are predominantly used for testing photovoltaic devices, which usually require a relatively shorter duration of exposure. Novel photothermal materials used for interfacial solar vapor generation utilizing the principle of heat localization, on the other hand, require a relatively much longer period of exposure and testing. This necessitates excellent stability for longer timescales, in addition to good spectrum distribution match and spatial uniformity of solar simulators. A hybrid LED-Halogen light source configuration for a solar simulator is proposed here which meets these requirements. An LED module (Phosphor coated blue LEDs, 100 W) producing warm white light is used as the primary light source, in conjunction with two commercially available Halogen lamps (50 W). The luminaire module performance in terms of spectrum distribution, intensity, effect of thermal management, interaction with neutral density filters and collimating lenses is investigated under different operating configurations. The assembled solar simulator is characterized based on spectrum distribution match, temporal instability, and spatial non-uniformity against global standards. Subsequently, an easily replicable photothermal fabric configuration is performance tested under the optimized solar simulator configuration, to evaluate its efficacy in terms of solar-to-vapor generation efficiency. The usefulness of the hybrid solar simulator system is established for long term testing as per the global standards.
- 21 June 2023
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 214
Transport phenomena and dynamics of an evaporating water meniscus at low heat fluxes
- 21 June 2023
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 214
Transport phenomena and dynamics of an evaporating water meniscus at low heat fluxes
- 30 March 2023
- Published by Springer Nature
- p. 75-80
Experimental Investigation of Heat Transfer During a Droplet Impacting Another Sessile Droplet on a Heated Substrate
- 30 March 2023
- Published by Springer Nature
- p. 75-80
Experimental Investigation of Heat Transfer During a Droplet Impacting Another Sessile Droplet on a Heated Substrate
- Open Access
- 17 February 2023
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 10
Role of offset during drop-on-drop impact dynamics on a superhydrophobic substrate
- 17 February 2023
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 10
Open AccessRole of offset during drop-on-drop impact dynamics on a superhydrophobic substrate
- 19 January 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 187
Effect of liquid splattering on thermal performance of jets and sprays over plain and pillared surfaces
- 19 January 2023
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 187
Effect of liquid splattering on thermal performance of jets and sprays over plain and pillared surfaces
- 9 August 2022
- Published by Taylor & Francis in Numerical Heat Transfer, Part B: Fundamentals
- Vol. 83 (3) , 39-57
Thermal transport during drop-on-drop impact on a heated superhydrophobic substrate
Interaction of multiple liquid droplets is ubiquitous in various engineering systems, for example, spray cooling in various forms, which is an attractive option to manage high heat flux applications. Thermal transport phenomena ensuing during drop-on-drop impact is numerically investigated here. One drop (Droplet #1) is kept stationary and in quasi-equilibrium on a heated superhydrophobic solid substrate, while the second drop (Droplet #2) is impacted vertically on it with a certain Weber number (WeDroplet #2 = 1.0, 4.0, and 8.2). The evolution of both droplets in different phases of impact, such as spreading, receding, and bounce-off regimes, along with associated heat transfer is scrutinized. The dependence of transport characteristics on various control parameters such as impact velocity of drop, volume ratio, fluid properties, and wall temperature are investigated. Distinct heat transfer trends are observed with the considered We number of impacting droplet (Droplet #2) being = 1.0, 4.0, and 8.2, respectively. Smaller droplet impacting with higher impact velocity results in more effective heat transfer as compared to a large droplet with small velocity, both having identical We number. To ease the analysis, comparison of heat transfer during drop-on-drop impact with a single droplet impact, having an equivalent diameter and velocity scales of the former drop-on-drop case, is also presented. It is revealed that the resulting heat transfer, with velocity scale based on momentum balance, is underpredicted, as compared to drop-on-drop impact. If the actual impact velocity of impacting droplet is taken, then the heat transfer gets overpredicted. Accordingly, analysis suggests that the appropriate representative velocity scale will be in-between these two bounds, which will accurately predict the heat transfer during drop-on-drop impact.
- 9 August 2022
- Published by Taylor & Francis in Numerical Heat Transfer, Part B: Fundamentals
- Vol. 83 (3) , 39-57
Thermal transport during drop-on-drop impact on a heated superhydrophobic substrate
Interaction of multiple liquid droplets is ubiquitous in various engineering systems, for example, spray cooling in various forms, which is an attractive option to manage high heat flux applications. Thermal transport phenomena ensuing during drop-on-drop impact is numerically investigated here. One drop (Droplet #1) is kept stationary and in quasi-equilibrium on a heated superhydrophobic solid substrate, while the second drop (Droplet #2) is impacted vertically on it with a certain Weber number (WeDroplet #2 = 1.0, 4.0, and 8.2). The evolution of both droplets in different phases of impact, such as spreading, receding, and bounce-off regimes, along with associated heat transfer is scrutinized. The dependence of transport characteristics on various control parameters such as impact velocity of drop, volume ratio, fluid properties, and wall temperature are investigated. Distinct heat transfer trends are observed with the considered We number of impacting droplet (Droplet #2) being = 1.0, 4.0, and 8.2, respectively. Smaller droplet impacting with higher impact velocity results in more effective heat transfer as compared to a large droplet with small velocity, both having identical We number. To ease the analysis, comparison of heat transfer during drop-on-drop impact with a single droplet impact, having an equivalent diameter and velocity scales of the former drop-on-drop case, is also presented. It is revealed that the resulting heat transfer, with velocity scale based on momentum balance, is underpredicted, as compared to drop-on-drop impact. If the actual impact velocity of impacting droplet is taken, then the heat transfer gets overpredicted. Accordingly, analysis suggests that the appropriate representative velocity scale will be in-between these two bounds, which will accurately predict the heat transfer during drop-on-drop impact.
- 14 May 2022
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 135, 106109
Energy efficient thermal management at low Reynolds number with air-ferrofluid Taylor bubble flows
- 14 May 2022
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 135, 106109
Energy efficient thermal management at low Reynolds number with air-ferrofluid Taylor bubble flows
- 14 May 2022
- Published by Elsevier in Scripta Materialia
- Vol. 218, 114776
Domination of phononic scattering in solid solutioning and interfaces of HfB2–ZrB2 – SiC -carbon nanotube based ultra high temperature composites
- 14 May 2022
- Published by Elsevier in Scripta Materialia
- Vol. 218, 114776
Domination of phononic scattering in solid solutioning and interfaces of HfB2–ZrB2 – SiC -carbon nanotube based ultra high temperature composites