Klevis Aliaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Klevis Aliaj has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Heath B. Henninger
Department of Orthopaedics, University of Utah, Salt Lake City, UT, United States; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States; Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, United States
7 shared publications Hema J. Sulkar
Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA
3 shared publications- Peter N. Chalmers
University of Utah
3 shared publications K. Bo Foreman
Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA; Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT, USA
2 shared publications- Kenneth Bo Foreman
Department of Physical Therapy, The University of Utah, Salt Lake City, UT, USA
2 shared publications - Robert Z. Tashjian
Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA
2 shared publications
Latest Publications
- 4 November 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (4) , e133-e144
High and low performers in internal rotation after reverse total shoulder arthroplasty: a biplane fluoroscopic study
- 4 November 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 32 (4) , e133-e144
High and low performers in internal rotation after reverse total shoulder arthroplasty: a biplane fluoroscopic study
- 9 May 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (10) , 2023-2033
Anatomic total shoulder glenoid component inclination affects glenohumeral kinetics during abduction: a cadaveric study
- 9 May 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (10) , 2023-2033
Anatomic total shoulder glenoid component inclination affects glenohumeral kinetics during abduction: a cadaveric study
- 24 March 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 136, 111059
Kinematic coupling of the glenohumeral and scapulothoracic joints generates humeral axial rotation
- 24 March 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 136, 111059
Kinematic coupling of the glenohumeral and scapulothoracic joints generates humeral axial rotation
- Open Access
- 21 December 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (68) , 3490
Kinematics-vis: A Visualization Tool for the Mathematics of Human Motion
Kinematic analysis studies characterize human motion in healthy, pathologic, and rehabilitated subjects. These studies provide rich datasets which enable clinicians and researchers to understand disease progression, and the effects of surgical intervention and physical therapy. A variety of techniques – ranging from optical skin marker tracking to biplane fluoroscopy – are utilized to collect these datasets. The quantification and physical interpretation of these motion capture datasets (i.e. kinematic analysis) are predominantly conducted using Euler/Cardan angles (Diebel, 2006; Wikipedia, 2021; Zatsiorsky, 1998), whose output – time series of 3 angles – is presented in peer-reviewed manuscripts in 2D graphs (Ludewig et al., 2009). This rudimentary presentation, however, obscures the physical meaning behind Euler/Cardan analysis. As other authors have noted, the visualization of these angles enables meaningful discussion between biomechanics researchers and clinicians (Baker, 2011). A ubiquitous open-source method to concurrently visualize recorded human motion and the results of kinematic analysis is presently lacking in the biomechanics community. ‘Kinematics-vis’ is a JavaScript web application that visualizes kinematic analysis output resulting from motion capture studies.
- 21 December 2021
- Published by The Open Journal in Journal of Open Source Software
- Vol. 6 (68) , 3490
Open AccessKinematics-vis: A Visualization Tool for the Mathematics of Human Motion
Kinematic analysis studies characterize human motion in healthy, pathologic, and rehabilitated subjects. These studies provide rich datasets which enable clinicians and researchers to understand disease progression, and the effects of surgical intervention and physical therapy. A variety of techniques – ranging from optical skin marker tracking to biplane fluoroscopy – are utilized to collect these datasets. The quantification and physical interpretation of these motion capture datasets (i.e. kinematic analysis) are predominantly conducted using Euler/Cardan angles (Diebel, 2006; Wikipedia, 2021; Zatsiorsky, 1998), whose output – time series of 3 angles – is presented in peer-reviewed manuscripts in 2D graphs (Ludewig et al., 2009). This rudimentary presentation, however, obscures the physical meaning behind Euler/Cardan analysis. As other authors have noted, the visualization of these angles enables meaningful discussion between biomechanics researchers and clinicians (Baker, 2011). A ubiquitous open-source method to concurrently visualize recorded human motion and the results of kinematic analysis is presently lacking in the biomechanics community. ‘Kinematics-vis’ is a JavaScript web application that visualizes kinematic analysis output resulting from motion capture studies.
- 20 September 2021
- Published by Elsevier in Gait & Posture
- Vol. 90, 380-387
Proximal humeral coordinate systems can predict humerothoracic and glenohumeral kinematics of a full bone system
- 20 September 2021
- Published by Elsevier in Gait & Posture
- Vol. 90, 380-387
Proximal humeral coordinate systems can predict humerothoracic and glenohumeral kinematics of a full bone system
- 8 May 2021
- Published by Elsevier in Gait & Posture
- Vol. 88, 28-36
Beyond Euler/Cardan analysis: True glenohumeral axial rotation during arm elevation and rotation
- 8 May 2021
- Published by Elsevier in Gait & Posture
- Vol. 88, 28-36
Beyond Euler/Cardan analysis: True glenohumeral axial rotation during arm elevation and rotation
- Open Access
- 9 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0242005
Replicating dynamic humerus motion using an industrial robot
Transhumeral percutaneous osseointegrated prostheses provide upper-extremity amputees with increased range of motion, more natural movement patterns, and enhanced proprioception. However, direct skeletal attachment of the endoprosthesis elevates the risk of bone fracture, which could necessitate revision surgery or result in loss of the residual limb. Bone fracture loads are direction dependent, strain rate dependent, and load rate dependent. Furthermore, in vivo, bone experiences multiaxial loading. Yet, mechanical characterization of the bone-implant interface is still performed with simple uni- or bi-axial loading scenarios that do not replicate the dynamic multiaxial loading environment inherent in human motion. The objective of this investigation was to reproduce the dynamic multiaxial loading conditions that the humerus experiences in vivo by robotically replicating humeral kinematics of advanced activities of daily living typical of an active amputee population. Specifically, 115 jumping jack, 105 jogging, 15 jug lift, and 15 internal rotation trials—previously recorded via skin-marker motion capture—were replicated on an industrial robot and the resulting humeral trajectories were verified using an optical tracking system. To achieve this goal, a computational pipeline that accepts a motion capture trajectory as input and outputs a motion program for an industrial robot was implemented, validated, and made accessible via public code repositories. The industrial manipulator utilized in this study was able to robotically replicate over 95% of the aforementioned trials to within the characteristic error present in skin-marker derived motion capture datasets. This investigation demonstrates the ability to robotically replicate human motion that recapitulates the inertial forces and moments of high-speed, multiaxial activities for biomechanical and orthopaedic investigations. It also establishes a library of robotically replicated motions that can be utilized in future studies to characterize the interaction of prosthetic devices with the skeletal system, and introduces a computational pipeline for expanding this motion library.
- 9 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0242005
Open AccessReplicating dynamic humerus motion using an industrial robot
Transhumeral percutaneous osseointegrated prostheses provide upper-extremity amputees with increased range of motion, more natural movement patterns, and enhanced proprioception. However, direct skeletal attachment of the endoprosthesis elevates the risk of bone fracture, which could necessitate revision surgery or result in loss of the residual limb. Bone fracture loads are direction dependent, strain rate dependent, and load rate dependent. Furthermore, in vivo, bone experiences multiaxial loading. Yet, mechanical characterization of the bone-implant interface is still performed with simple uni- or bi-axial loading scenarios that do not replicate the dynamic multiaxial loading environment inherent in human motion. The objective of this investigation was to reproduce the dynamic multiaxial loading conditions that the humerus experiences in vivo by robotically replicating humeral kinematics of advanced activities of daily living typical of an active amputee population. Specifically, 115 jumping jack, 105 jogging, 15 jug lift, and 15 internal rotation trials—previously recorded via skin-marker motion capture—were replicated on an industrial robot and the resulting humeral trajectories were verified using an optical tracking system. To achieve this goal, a computational pipeline that accepts a motion capture trajectory as input and outputs a motion program for an industrial robot was implemented, validated, and made accessible via public code repositories. The industrial manipulator utilized in this study was able to robotically replicate over 95% of the aforementioned trials to within the characteristic error present in skin-marker derived motion capture datasets. This investigation demonstrates the ability to robotically replicate human motion that recapitulates the inertial forces and moments of high-speed, multiaxial activities for biomechanical and orthopaedic investigations. It also establishes a library of robotically replicated motions that can be utilized in future studies to characterize the interaction of prosthetic devices with the skeletal system, and introduces a computational pipeline for expanding this motion library.