Vincent M. Levesque
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vincent M. Levesque has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Paul B. Shyn
Brigham and Women’s Hospital, Harvard Medical School
5 shared publications - Stuart G. Silverman
Brigham and Women’s Hospital, Harvard Medical School
3 shared publications - Julia G. Seol
Brigham and Women’s Hospital, Boston, USA
2 shared publications - Kemal Tuncali
Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis St., Boston, MA, USA
2 shared publications - Victor H. Gerbaudo
From the Departments of Radiology and Medicine, McMaster University, 1200 Main St W, Room 1P11, Hamilton, ON, Canada L8N 3Z5 (K.A.Z.); and Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Mass (V.H.G.).
2 shared publications Alan J. Cubre
Brigham and Women’s Hospital, Boston, USA
1 shared publication
Latest Publications
- Open Access
- 17 February 2022
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 29 (11) , 7009
Correction to: Outcomes Following Percutaneous Microwave and Cryoablation of Lung Metastases from Adenoid Cystic Carcinoma of the Head and Neck: A Bi-Institutional Retrospective Cohort Study
- 17 February 2022
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 29 (11) , 7009
Open AccessCorrection to: Outcomes Following Percutaneous Microwave and Cryoablation of Lung Metastases from Adenoid Cystic Carcinoma of the Head and Neck: A Bi-Institutional Retrospective Cohort Study
- 19 February 2021
- Published by Springer Nature in Abdominal Radiology
- Vol. 46 (7) , 3437-3447
F-18 FDG perfusion PET: intraprocedural assessment of the liver tumor ablation margin
Purpose To evaluate 18F-fluorodeoxyglucose (FDG) perfusion PET during FDG PET/CT-guided liver tumor microwave ablation procedures for assessing the ablation margin and correlating minimum margin measurements with local progression. Methods This IRB-approved, HIPAA-compliant study included 20 adult patients (11 M, 9 F; mean age 65) undergoing FDG PET/CT-guided liver microwave ablation to treat 31 FDG-avid tumors. Intraprocedural FDG perfusion PET was performed to assess the ablation margin. Intraprocedural decisions regarding overlapping ablations were recorded. Two readers retrospectively interpreted intraprocedural perfusion PET and postprocedural contrast-enhanced MRI. Assessability of the ablation margin and minimum margin measurements were recorded. Imaging follow-up for local progression ranged from 30 to 574 days (mean 310). Regression modeling of minimum margin measurements was performed. Hazard ratios were calculated to correlate an ablation margin threshold of 5 mm with outcomes. Results Intraprocedural perfusion PET prompted additional overlapping ablations of two tumors, neither of which progressed. Incomplete ablation or local progression occurred in 8/31 (26%) tumors. With repeat ablation, secondary efficacy was 26 (84%) of 31. Both study readers deemed ablation margins fully assessable more often using perfusion PET than MRI (OR 69.7; CI 6.0, 806.6; p = 0.001). Minimum ablation margins ≥ 5 mm on perfusion PET correlated with a low risk of incomplete ablation/local progression by both study readers (HR 0.08 and 0.02, p < 0.001). Conclusion Intraprocedural FDG perfusion PET consistently enabled complete liver tumor microwave ablation margin assessments, and the perfusion PET minimum ablation margin measurements correlated well with local outcomes. Clinical trial registration clinicaltrials.gov (NCT02018107).
- 19 February 2021
- Published by Springer Nature in Abdominal Radiology
- Vol. 46 (7) , 3437-3447
F-18 FDG perfusion PET: intraprocedural assessment of the liver tumor ablation margin
Purpose To evaluate 18F-fluorodeoxyglucose (FDG) perfusion PET during FDG PET/CT-guided liver tumor microwave ablation procedures for assessing the ablation margin and correlating minimum margin measurements with local progression. Methods This IRB-approved, HIPAA-compliant study included 20 adult patients (11 M, 9 F; mean age 65) undergoing FDG PET/CT-guided liver microwave ablation to treat 31 FDG-avid tumors. Intraprocedural FDG perfusion PET was performed to assess the ablation margin. Intraprocedural decisions regarding overlapping ablations were recorded. Two readers retrospectively interpreted intraprocedural perfusion PET and postprocedural contrast-enhanced MRI. Assessability of the ablation margin and minimum margin measurements were recorded. Imaging follow-up for local progression ranged from 30 to 574 days (mean 310). Regression modeling of minimum margin measurements was performed. Hazard ratios were calculated to correlate an ablation margin threshold of 5 mm with outcomes. Results Intraprocedural perfusion PET prompted additional overlapping ablations of two tumors, neither of which progressed. Incomplete ablation or local progression occurred in 8/31 (26%) tumors. With repeat ablation, secondary efficacy was 26 (84%) of 31. Both study readers deemed ablation margins fully assessable more often using perfusion PET than MRI (OR 69.7; CI 6.0, 806.6; p = 0.001). Minimum ablation margins ≥ 5 mm on perfusion PET correlated with a low risk of incomplete ablation/local progression by both study readers (HR 0.08 and 0.02, p < 0.001). Conclusion Intraprocedural FDG perfusion PET consistently enabled complete liver tumor microwave ablation margin assessments, and the perfusion PET minimum ablation margin measurements correlated well with local outcomes. Clinical trial registration clinicaltrials.gov (NCT02018107).
- 11 November 2020
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (5) , 1618-1625
Liver tumor F-18 FDG-PET before and immediately after microwave ablation enables imaging and quantification of tumor tissue contraction
Purpose Poor liver tumor visibility after microwave ablation (MWA) limits direct tumor ablation margin assessments using contrast-enhanced CT or ultrasound (US). Positron emission tomography (PET) or PET/CT may offer improved intraprocedural assessment of liver tumor ablation margins versus current imaging techniques, as 18F-fluorodeoxyglucose (18F-FDG)-avid tumors remain visible on PET immediately following ablation. The purpose of this study was to assess intraprocedural 18F-FDG PET scans before and immediately after PET/CT-guided MWA for visualization and quantification of metabolic liver tumor tissue contraction resulting from MWA. Methods This retrospective study, conducted at a large academic medical center after Institutional Review Board approval, included 36 patients (20 men; mean age 63 [range 37–85]) who underwent PET/CT-guided MWA of 42 18F-FDG-avid liver tumors from May 2013 to March 2018. Tumor metabolic diameters (short/long axes) were measured for each tumor on pre- and post-ablation PET images. Tumor metabolic volumes were calculated using tumor diameter measurements and compared with automated volumes using an SUV threshold algorithm. A two-tailed paired t test was used for the analyses. Results Comparing intraprocedural pre- and post-ablation PET images, mean metabolic tumor short- and long-axis diameters decreased from 21.4 to 14.9 mm [− 29%, p < 0.001, standard deviation (SD) 18%] and from 24.0 to 18.0 mm (− 24%, p < 0.001, SD 16%), respectively. The mean calculated tumor metabolic volume decreased from 10.5 to 4.6 mm3 (− 55%, p < 0.001, SD 26%). The mean automated tumor metabolic volume decreased from 10.6 to 5.8 mm3 (− 45%, p < 0.001, SD 30%). Conclusion Intraprocedural PET images of 18F-FDG-avid liver tumors allow visualization and quantification of MWA-induced metabolic tumor tissue contraction during 18F-FDG PET/CT-guided procedures. The ability to visualize contracted tumor immediately post-MWA may facilitate emerging intraprocedural PET and PET/CT imaging techniques that address a clinical gap in directly assessing the ablation margin.
- 11 November 2020
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 48 (5) , 1618-1625
Liver tumor F-18 FDG-PET before and immediately after microwave ablation enables imaging and quantification of tumor tissue contraction
Purpose Poor liver tumor visibility after microwave ablation (MWA) limits direct tumor ablation margin assessments using contrast-enhanced CT or ultrasound (US). Positron emission tomography (PET) or PET/CT may offer improved intraprocedural assessment of liver tumor ablation margins versus current imaging techniques, as 18F-fluorodeoxyglucose (18F-FDG)-avid tumors remain visible on PET immediately following ablation. The purpose of this study was to assess intraprocedural 18F-FDG PET scans before and immediately after PET/CT-guided MWA for visualization and quantification of metabolic liver tumor tissue contraction resulting from MWA. Methods This retrospective study, conducted at a large academic medical center after Institutional Review Board approval, included 36 patients (20 men; mean age 63 [range 37–85]) who underwent PET/CT-guided MWA of 42 18F-FDG-avid liver tumors from May 2013 to March 2018. Tumor metabolic diameters (short/long axes) were measured for each tumor on pre- and post-ablation PET images. Tumor metabolic volumes were calculated using tumor diameter measurements and compared with automated volumes using an SUV threshold algorithm. A two-tailed paired t test was used for the analyses. Results Comparing intraprocedural pre- and post-ablation PET images, mean metabolic tumor short- and long-axis diameters decreased from 21.4 to 14.9 mm [− 29%, p < 0.001, standard deviation (SD) 18%] and from 24.0 to 18.0 mm (− 24%, p < 0.001, SD 16%), respectively. The mean calculated tumor metabolic volume decreased from 10.5 to 4.6 mm3 (− 55%, p < 0.001, SD 26%). The mean automated tumor metabolic volume decreased from 10.6 to 5.8 mm3 (− 45%, p < 0.001, SD 30%). Conclusion Intraprocedural PET images of 18F-FDG-avid liver tumors allow visualization and quantification of MWA-induced metabolic tumor tissue contraction during 18F-FDG PET/CT-guided procedures. The ability to visualize contracted tumor immediately post-MWA may facilitate emerging intraprocedural PET and PET/CT imaging techniques that address a clinical gap in directly assessing the ablation margin.
- Open Access
- 1 March 2020
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 31 (3) , S61
3:36 PM Abstract No. 131 Liver tumor ablation procedure duration and estimated patient radiation dose: comparing positron emission tomography/computed tomography and computed tomography guidance
- 1 March 2020
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 31 (3) , S61
Open Access3:36 PM Abstract No. 131 Liver tumor ablation procedure duration and estimated patient radiation dose: comparing positron emission tomography/computed tomography and computed tomography guidance
- 1 November 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (11) , 2218-2221
Radiation dose during CT-guided percutaneous cryoablation of renal tumors: Effect of a dose reduction protocol
- 1 November 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (11) , 2218-2221
Radiation dose during CT-guided percutaneous cryoablation of renal tumors: Effect of a dose reduction protocol