Shuai Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuai Yuan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jian-Ying Zhang
2 shared publicationsBao-Feng Yang
1 shared publicationBing Wen
Inner Mongolia Power (Group) Co., Ltd. Inner Mongolia Power Research Institute Branch Hohhot China
1 shared publicationChuan-Qiang Che
Inner Mongolia Electric Power Research Institute, Hohhot, China
1 shared publicationDa-Peng Xu
Inner Mongolia Electric Power Research Institute, Hohhot, China
1 shared publication- Haowei Hao
Inner Mongolia Power Research Institute Branch, Inner Mongolia Power (Group) Co., Ltd., Hohhot 010020, China
1 shared publication
Latest Publications
- Open Access
- 11 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4647
Short-Circuit Current Analytical Method for Photovoltaic Systems Considering Dual Closed-Loop Control Dynamic Characteristics
Accurate short-circuit current calculation is crucial for protection coordination and grid integration of large-scale photovoltaic (PV) plants, yet conventional methods often lack transient accuracy. Based on field tests under varying power and voltage-dip conditions, this study proposes an analytical short-circuit current calculation method for PV systems considering the dynamic characteristics of dual closed-loop control. The complete fault transient process is divided into distinct stages according to control mode switching and limiter actions. The method incorporates stage-wise active power balance and approximates the outer-loop current reference via linearization, enabling the derivation of transient fault currents through a second-order response solution to piecewise linear references. Validation with field measurements confirms that the proposed approach improves the accuracy of transient short-circuit current compared to traditional methods, providing a reliable basis for protection coordination and grid integration of large-scale PV plants.
- 11 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4647
Open AccessShort-Circuit Current Analytical Method for Photovoltaic Systems Considering Dual Closed-Loop Control Dynamic Characteristics
Accurate short-circuit current calculation is crucial for protection coordination and grid integration of large-scale photovoltaic (PV) plants, yet conventional methods often lack transient accuracy. Based on field tests under varying power and voltage-dip conditions, this study proposes an analytical short-circuit current calculation method for PV systems considering the dynamic characteristics of dual closed-loop control. The complete fault transient process is divided into distinct stages according to control mode switching and limiter actions. The method incorporates stage-wise active power balance and approximates the outer-loop current reference via linearization, enabling the derivation of transient fault currents through a second-order response solution to piecewise linear references. Validation with field measurements confirms that the proposed approach improves the accuracy of transient short-circuit current compared to traditional methods, providing a reliable basis for protection coordination and grid integration of large-scale PV plants.
- Open Access
- 13 April 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (9) , 1855-1870
A state‐space average model of a three‐level PV inverter for transient short‐circuit currents analysis
This paper presents a state‐space average model of a three‐level photovoltaic (PV) inverter to understand short‐circuit currents transient characteristics. Analytical solution of the model is also derived. The proposed model is validated with PV system controller hardware in‐loop (HIL) test method. The errors between simulation and HIL tests results under various conditions are evaluated, testifying the validity of the proposed model. With the model and analytical solution, the decaying time constants of sub‐transient and transient processes are derived, which shows that the time constants of a three‐level PV inverter are not fixed and they vary with voltage dips. The analytical expression of short‐circuit currents is also formulated. The findings from this study are essential to short‐circuit current calculations of a power grid with large‐scale PV plants, coordination of power system protections, and grid planning.
- 13 April 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (9) , 1855-1870
Open AccessA state‐space average model of a three‐level PV inverter for transient short‐circuit currents analysis
This paper presents a state‐space average model of a three‐level photovoltaic (PV) inverter to understand short‐circuit currents transient characteristics. Analytical solution of the model is also derived. The proposed model is validated with PV system controller hardware in‐loop (HIL) test method. The errors between simulation and HIL tests results under various conditions are evaluated, testifying the validity of the proposed model. With the model and analytical solution, the decaying time constants of sub‐transient and transient processes are derived, which shows that the time constants of a three‐level PV inverter are not fixed and they vary with voltage dips. The analytical expression of short‐circuit currents is also formulated. The findings from this study are essential to short‐circuit current calculations of a power grid with large‐scale PV plants, coordination of power system protections, and grid planning.
- Open Access
- 30 March 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 4502-4511
Experimental study on short-circuit current characteristics of a photovoltaic system with low voltage ride through capability under a symmetrical fault
- 30 March 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 4502-4511
Open AccessExperimental study on short-circuit current characteristics of a photovoltaic system with low voltage ride through capability under a symmetrical fault
- Open Access
- 11 November 2020
- Published by SAGE Publications in Measurement and Control
- Vol. 53 (9-10) , 2010-2019
Measurement of the DC current based on magnetic fluids with an orthogonal magnetic field
Measurement of DC current is critically important in a wide range of applications, such as in photovoltaic power generation and DC power transmission. In this paper, the DC current measuring method based on magnetic fluids with orthogonal magnetic fields is studied. Firstly, the induced voltage of measurement coil, which contains a series of harmonics and the amplitude of its fundamental component is 2.5 times larger than that of other components, is derived and analyzed. Then, influence factors of the induced voltage are systematically studied. As a result, with a DC component injection into the exciting current, the frequency of the induced voltage becomes a half of that without a DC component, and when the DC component reaches to or exceeds the amplitude of the AC component, the induced voltage nearly has no distortion. Finally, the input-output characteristic of the measurement method is examined, and the accuracy, measuring range, and sensitivity are discussed, indicating that the linearity of the foundamental component root mean square (RMS) value curve is better than the one of the voltage amplitude curve under the same DC current range, and the sensitivities of induced voltage amplitude and the fundamental component RMS value are 5.948 and 3.717 mΩ, respectively.
- 11 November 2020
- Published by SAGE Publications in Measurement and Control
- Vol. 53 (9-10) , 2010-2019
Open AccessMeasurement of the DC current based on magnetic fluids with an orthogonal magnetic field
Measurement of DC current is critically important in a wide range of applications, such as in photovoltaic power generation and DC power transmission. In this paper, the DC current measuring method based on magnetic fluids with orthogonal magnetic fields is studied. Firstly, the induced voltage of measurement coil, which contains a series of harmonics and the amplitude of its fundamental component is 2.5 times larger than that of other components, is derived and analyzed. Then, influence factors of the induced voltage are systematically studied. As a result, with a DC component injection into the exciting current, the frequency of the induced voltage becomes a half of that without a DC component, and when the DC component reaches to or exceeds the amplitude of the AC component, the induced voltage nearly has no distortion. Finally, the input-output characteristic of the measurement method is examined, and the accuracy, measuring range, and sensitivity are discussed, indicating that the linearity of the foundamental component root mean square (RMS) value curve is better than the one of the voltage amplitude curve under the same DC current range, and the sensitivities of induced voltage amplitude and the fundamental component RMS value are 5.948 and 3.717 mΩ, respectively.