Heng Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heng Xie has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Lei Shi
Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China
2 shared publications Fei Xie
Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Tsinghua University, Beijing, China
1 shared publication- Han Zhang
Tsinghua University, Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Beijing 100084, China
1 shared publication Jian Li
Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Tsinghua University, Beijing, China
1 shared publication- Jie Liu
Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
1 shared publication Jing Zhao
Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- 30 January 2026
- Published by Taylor & Francis in Nuclear Technology
- p. 1-17
Impact of Circumferential Fabrication Deviations in Research Reactor Fuel Assemblies on the Thermal Behaviors of Fuel Meat
- 30 January 2026
- Published by Taylor & Francis in Nuclear Technology
- p. 1-17
Impact of Circumferential Fabrication Deviations in Research Reactor Fuel Assemblies on the Thermal Behaviors of Fuel Meat
- 16 March 2023
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 34 (3) , 1-16
Conceptual design and safety characteristics of a new multi-mission high flux research reactor
- 16 March 2023
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 34 (3) , 1-16
Conceptual design and safety characteristics of a new multi-mission high flux research reactor
- 22 February 2022
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 146, 104147
A preliminary analysis on optimization of core flow distribution
- 22 February 2022
- Published by Elsevier in Progress in Nuclear Energy
- Vol. 146, 104147
A preliminary analysis on optimization of core flow distribution
- Open Access
- 10 November 2020
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2020, 1-11
Numerical Study of the Air Ingress Accident of the HTR-PM and Possible Mitigation Measures
The double-ended guillotine break (DEGB) of the horizontal coaxial gas duct of a high-temperature gas-cooled reactor is an extremely hypothetical accident, which could cause the air to enter into the primary circuit and react with graphite in the reactor core. The performance of the HTR-PM plant under this extremely hypothetical accident has been studied by the system code TINTE in this work. The results show that the maximum fuel temperature will not reach the temperature design limitation, and the graphite oxidation will not cause unacceptable consequences even under some conservative assumptions. Moreover, nitrogen and helium injected from the fuel charging tube were studied as the possible mitigation measures to further alleviate the consequences of this air ingress accident. The preliminary results show that only the flow rate of nitrogen injected reaches a certain value, which can effectively alleviate the consequences, while for helium injection, both high and small flow rate can prevent or cut off the natural circulation and alleviate the consequences. The reason is that helium is much lighter than nitrogen, and the density difference between the coolant channel and the reactor core is small when helium is injected. Considering the injection velocity, the total usage amount, and the start time of gas injection, helium injected with a small flow rate is suggested.
- 10 November 2020
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2020, 1-11
Open AccessNumerical Study of the Air Ingress Accident of the HTR-PM and Possible Mitigation Measures
The double-ended guillotine break (DEGB) of the horizontal coaxial gas duct of a high-temperature gas-cooled reactor is an extremely hypothetical accident, which could cause the air to enter into the primary circuit and react with graphite in the reactor core. The performance of the HTR-PM plant under this extremely hypothetical accident has been studied by the system code TINTE in this work. The results show that the maximum fuel temperature will not reach the temperature design limitation, and the graphite oxidation will not cause unacceptable consequences even under some conservative assumptions. Moreover, nitrogen and helium injected from the fuel charging tube were studied as the possible mitigation measures to further alleviate the consequences of this air ingress accident. The preliminary results show that only the flow rate of nitrogen injected reaches a certain value, which can effectively alleviate the consequences, while for helium injection, both high and small flow rate can prevent or cut off the natural circulation and alleviate the consequences. The reason is that helium is much lighter than nitrogen, and the density difference between the coolant channel and the reactor core is small when helium is injected. Considering the injection velocity, the total usage amount, and the start time of gas injection, helium injected with a small flow rate is suggested.
- Open Access
- 1 January 2017
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2017, 1-13
Three Design Basis Accidents’ Analysis on the HTR-10GT
The study simulated the design basis accidents (DBAs) sequences of the HTR-10GT core with THERMIX. When a DBA happens, the protection system will receive a scram signal which shall lead to active measures to shut down the reactor following it. In the paper, three typical DBA cases were studied. They include an accident induced by station blackout, a case caused by the withdrawal of one control rod out of the core by a mistake, and a case resulting from an earthquake, respectively. The simulation results illustrate that the fuel peak temperatures in the core during these accidents are 1066°C, 1201°C and 1067°C, respectively. It is shown that the HTR-10GT has a good safety characteristic.
- 1 January 2017
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2017, 1-13
Open AccessThree Design Basis Accidents’ Analysis on the HTR-10GT
The study simulated the design basis accidents (DBAs) sequences of the HTR-10GT core with THERMIX. When a DBA happens, the protection system will receive a scram signal which shall lead to active measures to shut down the reactor following it. In the paper, three typical DBA cases were studied. They include an accident induced by station blackout, a case caused by the withdrawal of one control rod out of the core by a mistake, and a case resulting from an earthquake, respectively. The simulation results illustrate that the fuel peak temperatures in the core during these accidents are 1066°C, 1201°C and 1067°C, respectively. It is shown that the HTR-10GT has a good safety characteristic.
- 1 January 2005
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2005.3, 199-200
3521 Detailed Analysis of Multi-phase Flow in Nuclear Reactor Cores Using a Particle Method
- 1 January 2005
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2005.3, 199-200
3521 Detailed Analysis of Multi-phase Flow in Nuclear Reactor Cores Using a Particle Method