Hangjie Mo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hangjie Mo has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Dong Sun
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
10 shared publications Liuxi Xing
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
5 shared publications- Xiaojian Li
School of Management, Hefei University of Technology, Hefei, China
5 shared publications - Yun-Hui Liu
The Chinese University of Hong Kong
5 shared publications - Ruofeng Wei
Department of Computer Science and Engineering, The Chinese University of Hong Kong, Hong Kong, China
4 shared publications Xiaojian Li
School of Management, the Key Laboratory of Process Optimization and Intelligent Decision-Making, and the Data Science and Smart Society Governance Laboratory, Hefei University of Technology, Hefei, China
4 shared publications
Latest Publications
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
Design and Evaluation of a Compact, MR-Compatible Origami Continuum Robot with Variable Length
Continuum robots have recently gained attention for their great value in medical applications. This paper presents a novel design approach for MR-compatible medical continuum robots with the ability to variable length and controllable motion at compact size and light weight. The robot employs a small-scale origami continuum structure with an outside diameter of 15 mm, is driven by three tendon-shape memory alloy (SMA) actuators, and senses the motion of actuators by a thin linear potentiometer (Thinpot). The robot system is lightweight at 76.7 g and compact, with the proximal sensing and actuation module measuring only 34 mm in diameter and 90 mm in length. It is first demonstrated that the Thinpot is insensitive to magnetic disturbance and MR-compatible and can realize accurate feedback control of the large stroke of SMA actuators, even in a real 1.5T MR environment. Further, the bending angle and tip position of the robot can be controlled based on an inverse kinematic model. The robots equipped with different tools will show versatility in biomedical applications, such as endoscopy and needle insertion.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
Design and Evaluation of a Compact, MR-Compatible Origami Continuum Robot with Variable Length
Continuum robots have recently gained attention for their great value in medical applications. This paper presents a novel design approach for MR-compatible medical continuum robots with the ability to variable length and controllable motion at compact size and light weight. The robot employs a small-scale origami continuum structure with an outside diameter of 15 mm, is driven by three tendon-shape memory alloy (SMA) actuators, and senses the motion of actuators by a thin linear potentiometer (Thinpot). The robot system is lightweight at 76.7 g and compact, with the proximal sensing and actuation module measuring only 34 mm in diameter and 90 mm in length. It is first demonstrated that the Thinpot is insensitive to magnetic disturbance and MR-compatible and can realize accurate feedback control of the large stroke of SMA actuators, even in a real 1.5T MR environment. Further, the bending angle and tip position of the robot can be controlled based on an inverse kinematic model. The robots equipped with different tools will show versatility in biomedical applications, such as endoscopy and needle insertion.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (4) , 1325-1336
Overlap-Aware Online-Adaptive Non-Rigid Registration of Intraoperative Tissue in Minimally Invasive Surgery
Non-rigid registration of intraoperative tissue is essential for surgical navigation and scene reconstruction in minimally invasive surgery. However, accurate registration remains challenging due to significant tissue deformation and partial overlaps caused by laparoscope movement. We propose an Overlap-Aware Online-Adaptive Non-Rigid Registration Method (OANRM) to address these challenges. The framework introduces a Hierarchical Matching Network (HMNet) that simultaneously predicts overlapping regions and their correspondences through a novel similarity-based approach. Our method uniquely incorporates an online adaptation mechanism that continuously fine-tunes the network parameters using unsupervised losses, enabling robust performance across varying surgical scenarios without requiring additional training data. A Transform Displacement Deformation Prediction (TDDP) module further enhances the framework by handling non-overlapping regions through integrating Random Sample Consensus with distance-based interpolation. The method is validated on both artificial datasets with controlled deformations and clinical datasets from real surgical procedures. Experimental results demonstrate that OANRM achieves state-of-the-art performance, significantly outperforming existing methods in handling complex tissue deformations and varying overlap ratios. https://github.com/AIGCer0807/OANRM.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (4) , 1325-1336
Overlap-Aware Online-Adaptive Non-Rigid Registration of Intraoperative Tissue in Minimally Invasive Surgery
Non-rigid registration of intraoperative tissue is essential for surgical navigation and scene reconstruction in minimally invasive surgery. However, accurate registration remains challenging due to significant tissue deformation and partial overlaps caused by laparoscope movement. We propose an Overlap-Aware Online-Adaptive Non-Rigid Registration Method (OANRM) to address these challenges. The framework introduces a Hierarchical Matching Network (HMNet) that simultaneously predicts overlapping regions and their correspondences through a novel similarity-based approach. Our method uniquely incorporates an online adaptation mechanism that continuously fine-tunes the network parameters using unsupervised losses, enabling robust performance across varying surgical scenarios without requiring additional training data. A Transform Displacement Deformation Prediction (TDDP) module further enhances the framework by handling non-overlapping regions through integrating Random Sample Consensus with distance-based interpolation. The method is validated on both artificial datasets with controlled deformations and clinical datasets from real surgical procedures. Experimental results demonstrate that OANRM achieves state-of-the-art performance, significantly outperforming existing methods in handling complex tissue deformations and varying overlap ratios. https://github.com/AIGCer0807/OANRM.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7249-7260
Adaptive Deep Koopman Operators for Soft Robot Control: Application to Luban Lock Disassembly
Soft robots have attracted considerable attention due to their intrinsic compliance and environmental adaptability in complex dynamic scenarios. However, their infinite degrees of freedom and strongly nonlinear dynamics present fundamental challenges in precise modeling and control. To address this issue, this article proposes an adaptive deep Koopman (ADK) modeling approach for model-based optimal control of soft robots. Our approach incorporates the control-oriented loss functions into the deep Koopman modeling framework to regulate open-loop poles and singular values of the controllability matrix, bridging the critical gap between the Koopman model learning and closed-loop control. The model parameters in the Koopman observable space are further updated online to account for dynamic changes under material wear and load variations. We develop a model-based optimal controller with the ADK model for soft robots, where an integral action is introduced to improve the control performance under varying load conditions and inaccurate feedforward control inputs. Extensive experimental validations including set-point regulation under varying load conditions and autonomous disassembly of a three-way Luban lock are conducted, which demonstrate the effectiveness and robustness of our approach.
- 13 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7249-7260
Adaptive Deep Koopman Operators for Soft Robot Control: Application to Luban Lock Disassembly
Soft robots have attracted considerable attention due to their intrinsic compliance and environmental adaptability in complex dynamic scenarios. However, their infinite degrees of freedom and strongly nonlinear dynamics present fundamental challenges in precise modeling and control. To address this issue, this article proposes an adaptive deep Koopman (ADK) modeling approach for model-based optimal control of soft robots. Our approach incorporates the control-oriented loss functions into the deep Koopman modeling framework to regulate open-loop poles and singular values of the controllability matrix, bridging the critical gap between the Koopman model learning and closed-loop control. The model parameters in the Koopman observable space are further updated online to account for dynamic changes under material wear and load variations. We develop a model-based optimal controller with the ADK model for soft robots, where an integral action is introduced to improve the control performance under varying load conditions and inaccurate feedforward control inputs. Extensive experimental validations including set-point regulation under varying load conditions and autonomous disassembly of a three-way Luban lock are conducted, which demonstrate the effectiveness and robustness of our approach.
- Open Access
- 18 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 6, 0339
ModelBasedControlofaContinuumManipulatorwithOnlineJacobianErrorCompensationUsingKalmanFiltering
Flexible continuum robots exhibit excellent adaptability to a wide range of tasks and environments. However, accurate and efficient modeling and control remain challenging due to their inherent nonlinearities. In this article, a hybrid model-based and online data-driven control method is proposed for a tendon-driven continuum robot, which requires no prior dataset collection or training. The method incorporates the Jacobian derived from the piecewise constant curvature model with online Jacobian error compensation using a Kalman filter. Consecutive Jacobian estimates are constrained to reduce fluctuations and improve stability in real-time estimation. Experimental results validate the effectiveness of the proposed hybrid approach in enhancing tracking accuracy and demonstrate its robustness against external disturbances.
- 18 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 6, 0339
Open AccessModelBasedControlofaContinuumManipulatorwithOnlineJacobianErrorCompensationUsingKalmanFiltering
Flexible continuum robots exhibit excellent adaptability to a wide range of tasks and environments. However, accurate and efficient modeling and control remain challenging due to their inherent nonlinearities. In this article, a hybrid model-based and online data-driven control method is proposed for a tendon-driven continuum robot, which requires no prior dataset collection or training. The method incorporates the Jacobian derived from the piecewise constant curvature model with online Jacobian error compensation using a Kalman filter. Consecutive Jacobian estimates are constrained to reduce fluctuations and improve stability in real-time estimation. Experimental results validate the effectiveness of the proposed hybrid approach in enhancing tracking accuracy and demonstrate its robustness against external disturbances.
- Open Access
- 11 February 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (7)
A Shared Control Method of Multiobjective Motion Fusion for Surgical Robot
Shared control combines human intelligence with autonomous algorithms, demonstrating potential for enhancing the intricate and dynamic operational capabilities of robots. In robotic surgery, shared control can integrate autonomous functions into master–slave control, which enables surgeons to receive certain control assistance while maintaining control of the operation. Such a shared control system must handle multiple types of dynamically changing motion tasks, for instance, trajectory tracking, obstacle avoidance, spatial constraint, and safety guarantee. This article proposes an innovative shared control method based on multiobjective motion fusion (MoMF) by integrating multiple objective controllers into master–slave control mode. In addition, a state feedback mechanism with prediction and evaluation model is developed to balance the control inputs of different control objectives. Further, an objective priority partition function is designed to overcome the conflicts between control objectives. In the proposed method, objective controllers can be added or removed as needed. The theoretical stability of the proposed MoMF method is proved. As an example, a fusion controller that considers four control objectives of a surgical cutting operation is designed to demonstrate the practicability of this method. Finally, the feasibility and effectiveness of the proposed MoMF method are validated by simulations and prosthesis experiments.
- 11 February 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (7)
Open AccessA Shared Control Method of Multiobjective Motion Fusion for Surgical Robot
Shared control combines human intelligence with autonomous algorithms, demonstrating potential for enhancing the intricate and dynamic operational capabilities of robots. In robotic surgery, shared control can integrate autonomous functions into master–slave control, which enables surgeons to receive certain control assistance while maintaining control of the operation. Such a shared control system must handle multiple types of dynamically changing motion tasks, for instance, trajectory tracking, obstacle avoidance, spatial constraint, and safety guarantee. This article proposes an innovative shared control method based on multiobjective motion fusion (MoMF) by integrating multiple objective controllers into master–slave control mode. In addition, a state feedback mechanism with prediction and evaluation model is developed to balance the control inputs of different control objectives. Further, an objective priority partition function is designed to overcome the conflicts between control objectives. In the proposed method, objective controllers can be added or removed as needed. The theoretical stability of the proposed MoMF method is proved. As an example, a fusion controller that considers four control objectives of a surgical cutting operation is designed to demonstrate the practicability of this method. Finally, the feasibility and effectiveness of the proposed MoMF method are validated by simulations and prosthesis experiments.
- Top Cited PapersOpen Access
- 9 September 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (2)
Review of Human–Robot Collaboration in Robotic Surgery
Human–robot collaboration (HRC) technology has emerged as a pivotal innovation in robotic surgery, significantly augmenting surgeons’ capabilities and enhancing the precision, safety, and efficacy of surgical procedures. This technology has been widely adopted across various surgical disciplines, including general surgery, cardiothoracic surgery, urology, and neurosurgery. By classifying HRC technology into three interactive modes based on the level of autonomy in robot‐assisted minimally invasive surgery, key technologies in imaging perception, force sensing, and human–robot interaction control methods are thoroughly explored. In this review, a comprehensive and up‐to‐date overview of advancements in HRC technology within surgical robotics is provided. Additionally, this review delves into the challenges and safety concerns associated with employing robotic systems in surgery, highlighting areas for improvement and innovation. Finally, a forward‐looking perspective on trends in HRC technology is presented, offering insights into how emerging innovations are set to enhance and transform surgical practices.
- 9 September 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (2)
Top Cited PapersOpen AccessReview of Human–Robot Collaboration in Robotic Surgery
Human–robot collaboration (HRC) technology has emerged as a pivotal innovation in robotic surgery, significantly augmenting surgeons’ capabilities and enhancing the precision, safety, and efficacy of surgical procedures. This technology has been widely adopted across various surgical disciplines, including general surgery, cardiothoracic surgery, urology, and neurosurgery. By classifying HRC technology into three interactive modes based on the level of autonomy in robot‐assisted minimally invasive surgery, key technologies in imaging perception, force sensing, and human–robot interaction control methods are thoroughly explored. In this review, a comprehensive and up‐to‐date overview of advancements in HRC technology within surgical robotics is provided. Additionally, this review delves into the challenges and safety concerns associated with employing robotic systems in surgery, highlighting areas for improvement and innovation. Finally, a forward‐looking perspective on trends in HRC technology is presented, offering insights into how emerging innovations are set to enhance and transform surgical practices.
- Open Access
- 9 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 731-737
Automated Cross-modal Registration Algorithm For Liver Surgery Navigation
- 9 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 731-737
Open AccessAutomated Cross-modal Registration Algorithm For Liver Surgery Navigation
- 7 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 4269-4282
Absolute Monocular Depth Estimation on Robotic Visual and Kinematics Data via Self-Supervised Learning
Accurate estimation of absolute depth from a monocular endoscope is a fundamental task for automatic navigation systems in robotic surgery. Previous works solely rely on uni-modal data ( i.e. , monocular images), which can only estimate depth values arbitrarily scaled with the real world. In this paper, we present a novel framework, SADER, which explores vision and robot kinematics to estimate the high-quality absolute depth for monocular surgical scenes. To jointly learn the multi-modal data, we introduce a self-distillation based two-stage training policy in the framework. In the first stage, a boosting depth module based on vision transformer is proposed to improve the relative depth estimation network that is trained in a self-supervised method. Then, we develop an algorithm to automatically compute the scale from robot kinematics. By coupling the scale and relative depth data, pseudo absolute depth labels for all images are yielded. In the second stage, we re-train the network with 3D loss supervised by pseudo labels. To make our method generalize to different endoscopes, the learning of endoscopic intrinsics is integrated into the network. In addition, we did cadaver experiments to collect new surgical depth estimation data about robotic laparoscopy for evaluation. Experimental results on public SCARED and cadaver data demonstrate that the SADER outperforms previous state-of-art even stereo-based methods with an accuracy error under 1.90 mm, proving the feasibility of our approach to recover the absolute depth with monocular inputs. Note to Practitioners —This paper aims to solve the problem of absolute monocular depth estimation in automatic surgical navigation by leveraging the multi-modal data from the robot-based endoscopic system. Accurate depth perception with real scales of the monocular scene is essential for the control of surgical robots in automatic navigation. However, current methods can only predict the relative depth of the surgical scene using monocular images. In this article, we propose a self-supervised learning-based method to achieve high-quality absolute depth estimation of monocular endoscopic images. It neither needs manual data annotation, nor other imaging modalities. The experiments extensively validate the feasibility and high performance of our framework for absolute depth estimation on monocular endoscopes. This absolute depth perception framework can be potentially encapsulated into the automatic navigation system in the near future.
- 7 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 4269-4282
Absolute Monocular Depth Estimation on Robotic Visual and Kinematics Data via Self-Supervised Learning
Accurate estimation of absolute depth from a monocular endoscope is a fundamental task for automatic navigation systems in robotic surgery. Previous works solely rely on uni-modal data ( i.e. , monocular images), which can only estimate depth values arbitrarily scaled with the real world. In this paper, we present a novel framework, SADER, which explores vision and robot kinematics to estimate the high-quality absolute depth for monocular surgical scenes. To jointly learn the multi-modal data, we introduce a self-distillation based two-stage training policy in the framework. In the first stage, a boosting depth module based on vision transformer is proposed to improve the relative depth estimation network that is trained in a self-supervised method. Then, we develop an algorithm to automatically compute the scale from robot kinematics. By coupling the scale and relative depth data, pseudo absolute depth labels for all images are yielded. In the second stage, we re-train the network with 3D loss supervised by pseudo labels. To make our method generalize to different endoscopes, the learning of endoscopic intrinsics is integrated into the network. In addition, we did cadaver experiments to collect new surgical depth estimation data about robotic laparoscopy for evaluation. Experimental results on public SCARED and cadaver data demonstrate that the SADER outperforms previous state-of-art even stereo-based methods with an accuracy error under 1.90 mm, proving the feasibility of our approach to recover the absolute depth with monocular inputs. Note to Practitioners —This paper aims to solve the problem of absolute monocular depth estimation in automatic surgical navigation by leveraging the multi-modal data from the robot-based endoscopic system. Accurate depth perception with real scales of the monocular scene is essential for the control of surgical robots in automatic navigation. However, current methods can only predict the relative depth of the surgical scene using monocular images. In this article, we propose a self-supervised learning-based method to achieve high-quality absolute depth estimation of monocular endoscopic images. It neither needs manual data annotation, nor other imaging modalities. The experiments extensively validate the feasibility and high performance of our framework for absolute depth estimation on monocular endoscopes. This absolute depth perception framework can be potentially encapsulated into the automatic navigation system in the near future.
- 12 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 2946-2955
Automated Control of Microparticle Swarm in a Rotating Gradient-Based Magnetic Field
The magnetic micromanipulation of swarm microparticles has attracted considerable attention because of its advantages of non-invasiveness, high drug-carrying capacity, and easy observation in the targeted delivery in in-vivo environments. This paper presents an automated control scheme for the magnetic micromanipulation of microswarms in a rotating gradient-based field. Different from the rotating uniform magnetic field generated by Helmholtz coils, the rotating gradient-based field is a type of convergent field established by sequentially powering each coil of the electromagnetic coil system. By changing the coil currents, the field can rotate while driving the microswarm to a pre-determined position, facilitating the swarm localization and tracking. According to the preliminary motion characterization of the swarm in the rotating gradient-based field, an intuitive trapping dynamic model which can simplify the analysis of swarm dynamics is established to facilitate controller design. Based on this model, a super-twisting sliding mode estimator is first designed to estimate the position of the microswarm as well as the disturbances caused by parameter variations and unmodeled dynamics. A robust controller is then developed based on the estimator. In this way, closed-loop manipulation of the microswarm to follow a desired trajectory in the rotating gradient-based field is realized, and the system’s behavior has been significantly improved due to the capability to estimate disturbances. The proposed control scheme for the rotating gradient-based field has the potential to avoid volume loss and unexpected drug diffusion of the swarm when facing complex in-vivo environments. The stability of the control scheme is proved by the Lyapunov approach. Experiments are finally performed to demonstrate the effectiveness of the proposed control approach in a collision-free environment and in a simulated channel. Note to Practitioners —The motivation of this study is to realize automated feedback control of the microparticle swarm in a rotating gradient-based magnetic field. The rotating gradient-based magnetic field is a type of convergent field that can rotate while driving the microswarm to a pre-determined position. This magnetic actuation method facilitates microswarm tracking and enables microagents to overcome static friction with the bottom substrate by rotating them, thereby inducing movement. However, existing research on the rotating gradient-based magnetic field concentrates on moving the microswarm to the targeted position without real-time visual guidance in an open-loop manner, which provides less reliability and convenience compared to real-time closed-loop control. Moreover, it will result in unavoidable volume loss when collisions happen in the complicated environments. In addition, the existing swarm dynamics in such a field need to be simplified to apply in controller design. To solve the above problems, an automated point-to-point navigation control scheme is proposed in this study. An intuitive trapping model is first established to simplify the swarm dynamics. Then, a robust controller with a super-twisting algorithm-based estimator is designed based on the model to manipulate the microswarm. Experimental results have shown that the proposed method can successfully control the microparticle swarm in collision-free environments and a simulated channel with considerable accuracy in the rotating gradient-based magnetic field. The proposed control scheme has the potential to avoid volume loss and unexpected drug diffusion of the swarm when facing complex in-vivo vascular environments, particularly those involve fluids with completely different directions in a bifurcation, such as the vascular network of lymphatic vessels and blood vessels.
- 12 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 2946-2955
Automated Control of Microparticle Swarm in a Rotating Gradient-Based Magnetic Field
The magnetic micromanipulation of swarm microparticles has attracted considerable attention because of its advantages of non-invasiveness, high drug-carrying capacity, and easy observation in the targeted delivery in in-vivo environments. This paper presents an automated control scheme for the magnetic micromanipulation of microswarms in a rotating gradient-based field. Different from the rotating uniform magnetic field generated by Helmholtz coils, the rotating gradient-based field is a type of convergent field established by sequentially powering each coil of the electromagnetic coil system. By changing the coil currents, the field can rotate while driving the microswarm to a pre-determined position, facilitating the swarm localization and tracking. According to the preliminary motion characterization of the swarm in the rotating gradient-based field, an intuitive trapping dynamic model which can simplify the analysis of swarm dynamics is established to facilitate controller design. Based on this model, a super-twisting sliding mode estimator is first designed to estimate the position of the microswarm as well as the disturbances caused by parameter variations and unmodeled dynamics. A robust controller is then developed based on the estimator. In this way, closed-loop manipulation of the microswarm to follow a desired trajectory in the rotating gradient-based field is realized, and the system’s behavior has been significantly improved due to the capability to estimate disturbances. The proposed control scheme for the rotating gradient-based field has the potential to avoid volume loss and unexpected drug diffusion of the swarm when facing complex in-vivo environments. The stability of the control scheme is proved by the Lyapunov approach. Experiments are finally performed to demonstrate the effectiveness of the proposed control approach in a collision-free environment and in a simulated channel. Note to Practitioners —The motivation of this study is to realize automated feedback control of the microparticle swarm in a rotating gradient-based magnetic field. The rotating gradient-based magnetic field is a type of convergent field that can rotate while driving the microswarm to a pre-determined position. This magnetic actuation method facilitates microswarm tracking and enables microagents to overcome static friction with the bottom substrate by rotating them, thereby inducing movement. However, existing research on the rotating gradient-based magnetic field concentrates on moving the microswarm to the targeted position without real-time visual guidance in an open-loop manner, which provides less reliability and convenience compared to real-time closed-loop control. Moreover, it will result in unavoidable volume loss when collisions happen in the complicated environments. In addition, the existing swarm dynamics in such a field need to be simplified to apply in controller design. To solve the above problems, an automated point-to-point navigation control scheme is proposed in this study. An intuitive trapping model is first established to simplify the swarm dynamics. Then, a robust controller with a super-twisting algorithm-based estimator is designed based on the model to manipulate the microswarm. Experimental results have shown that the proposed method can successfully control the microparticle swarm in collision-free environments and a simulated channel with considerable accuracy in the rotating gradient-based magnetic field. The proposed control scheme has the potential to avoid volume loss and unexpected drug diffusion of the swarm when facing complex in-vivo vascular environments, particularly those involve fluids with completely different directions in a bifurcation, such as the vascular network of lymphatic vessels and blood vessels.