HLHubert Löwenheim

Hubert Löwenheim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hubert Löwenheim has a total of 436 co-authors. Here are the top co-authors by number of shared publications:

  • Marcus Müller

    Translational Hearing Research, Tübingen Hearing Research Center, Department of Otolaryngology, Head & Neck Surgery, University of Tübingen, Tübingen, Germany

    12 shared publications
  • Marcus Müller

    Department of Neurology, Universitätsklinikum Münster, Münster, Germany

    10 shared publications
  • Anke Tropitzsch

    Department of Otolaryngology–Head & Neck Surgery, Tübingen Hearing Research Centre Eberhard Karls University Tübingen Tübingen Germany

    9 shared publications
  • Rainer Zimmermann

    Department of Otorhinolaryngology-Head and Neck Surgery, University of Tübingen, Tübingen

    7 shared publications
  • Hans-Peter Zenner

    Universitätsklinik für Hals-Nasen-Ohren-Heilkunde - Kopf- & Hals-Chirurgie

    6 shared publications
  • M. Müller

    School of Medicine and Health Sciences - European Medical School, University Hospital of Otorhinolaryngology, Medical Campus University of Oldenburg, Steinweg 13-17, 26122, Oldenburg, Germany

    6 shared publications

Latest Publications

  • Open Access

    Feasibility of Ultra-Low-Dose Photon-Counting CT for Anatomy-Based Cochlear Implant Fitting: A Cadaveric Proof-of-Concept Study

    by Thore Schade-Mann, Hubert Löwenheim, Tobias Albrecht

    Hypothesis: Stepwise reduction of CT tube current during postoperative photon-counting detector CT (PCD-CT) imaging preserves the frequency-estimation accuracy required for anatomy-based cochlear-implant fitting at doses as low as 5% of the clinical standard. Background: Anatomy-based fitting (ABF) uses postoperative CT to allocate electrode contacts to the cochlear frequency map, reducing frequency-to-place mismatch and potentially improving cochlear implant (CI) outcomes. While PCD-CT lowers radiation compared with conventional CT, the minimum postoperative dose compatible with ABF has not been established. Methods: A human body donor was imaged with PCD-CT (NAEOTOM Alpha, Siemens Healthineers) before and after CI test electrode insertion via a round window approach at 100%, 50%, 25%, 10%, and 5% tube current. Electrode angular insertion depth and frequency position were extracted using OTOPLAN software (Version 4, Cascination). Frequency deviations from the 100% reference were quantified in semitones. Analysis was repeated using the 50% preoperative scan as an alternative reference standard, extending previously published preoperative dose-reduction findings. Results: Electrode detection was successful at all dose levels for the evaluated intracochlear contacts. Using the 100% preoperative reference, mean frequency deviation at 5% postoperative dose was 0.02±0.29 semitones, with no evaluated contact exceeding one semitone. When the 50% preoperative scan served as reference, deviations remained ≤1 semitone for postoperative doses ≥10%; three adjacent contacts marginally exceeded this threshold at 5% postoperative dose (maximum: −1.20 semitones). Conclusions: In this single-donor proof-of-concept study, PCD-CT at 5% of the institutional reference dose retained electrode visibility and yielded small frequency-estimation deviations for the evaluated intracochlear contacts. These findings therefore support the technical feasibility of substantial postoperative dose reduction within the evaluated electrode region. Validation using complete insertions in larger clinical cohorts is required.

  • Open Access

    Long-term Incidence of Revision Surgery Caused by Electrode Migration in a Large Cochlear Implant Cohort Using a Titanium Fixation Clip Applied by a Novel Reverse Application Technique

    by Georg Schweizer, Thore Schade-Mann, Lina Maria Serna-Higuita, Agnes Mühle, Philipp Gamerdinger, Martin Holderried, Steffen Paasch, Hubert Löwenheim, Anke Tropitzsch

    Objective: To determine the effect on the frequency of revision surgery caused by electrode migration (EM) in cochlear implantation by use of an electrode fixation clip combined with a novel surgical technique. Study Design: Retrospective chart review. Setting: Tertiary referral center. Patients: The investigated institutional cohort included 1052 cases of cochlear implantation with straight electrode arrays from a single manufacturer between 2011 and 2023. Until 2016, the fixation clip was not used, whereas since 2017, the fixation clip and the described novel surgical technique have been applied as an institutional standard in nearly all cases. Intervention: The titanium electrode fixation clip was first introduced and described in 1998 and was CE marked in Europe in 2014. In modification of the original description, a “Reverse Fixation Clip Technique” was applied to optimize the surgical handling and fixation stability. A similar approach has been described recently. Main Outcome Measure: Cumulative incidence of revision surgery caused by EM. Results: The cumulative incidence of revision surgery caused by EM at 3, 5, and 7 years was 0.5%, 1.0%, and 1.9% in the group without the fixation clip (n=461; 43.4%) and 0.0% at all time points in the group with the fixation clip using the “Reverse Fixation Clip Technique” (n=591; 56.6%) (log-rank test P =0.054). No fixation clip-related complications were noted. Conclusion: The application of the fixation clip using the “Reverse Fixation Clip Technique” prevents revision surgery caused by EM in cochlear implantation.

  • Open Access

    Deafness Progressing to Cochlear Implant Eligibility Is Eight Times More Likely in the Hypoplastic Than the Degenerative Endotype of Menière's Disease

    by Catrin Brühlmann, Jennifer L. Spiegel, Agnes Mühle, Adrian Dalbert, Vincent Y. W. Lin, Trung N. Le, Thore Schade-Mann, Jessica Knoppik, Dorothe Veraguth, Ösli Christof Rö, et al.

    Objective: To investigate whether one of the two recently described MD endotypes—defined by either endolymphatic sac degeneration (MD-dg patients) or hypoplasia (MD-hp patients)—is associated with an increased likelihood of undergoing CI. Study Design: Retrospective multicenter cross-sectional study. Setting: Five tertiary referral centers. Patients: CI cohort: 115 adult MD patients with a history of uni- or bilateral CI. Non-CI cohort: 72 MD patients with no CI history. All included patients matched current diagnostic criteria for definite MD. Intervention: Cochlear implantation. Main Outcome Measures: Endotype distribution (MD-dg versus MD-hp) between the CI cohort and the non-CI cohort. The endotype was determined using high-resolution CT data based on the angular trajectory of the vestibular aqueduct, following established protocols. Secondary outcomes included disease laterality, age at MD diagnosis, duration of MD, and pre-CI hearing thresholds. Results: The CI cohort included significantly more MD-hp patients than the non-CI cohort (72% versus 24%, p < 0.0001). The odds ratio of CI for an MD-hp patient relative to an MD-dg patient was 8.4 (95% confidence interval, 4.3–16.1). Pre-CI audiometric data showed no significant differences in hearing thresholds between endotypes, neither in the implanted nor in the non-implanted ear. Conclusions: The MD-hp endotype, frequently associated with bilateral disease and early-age disease onset, is strongly linked to a higher likelihood of CI. Endotyping of MD patients based on endolymphatic sac pathology can effectively stratify their risk of severe hearing loss, guiding personalized audiological follow-up and clinical decisions regarding potential CI.


  • Open Access

    PSMA-Guided Imaging and Therapy of Advanced Adenoid Cystic Carcinomas and Other Salivary Gland Carcinomas

    by Nils F. Trautwein, Andreas Brendlin, Gerald Reischl, Moritz Mattke, Frank Paulsen, Hubert Loewenheim, Lars Zender, Christian la Fougère, Helmut Dittmann

    SGCs are rare malignancies, accounting for less than 1% of all head and neck cancers


  • Open Access

    Closing the Gap between the Auditory Nerve and Cochlear Implant Electrodes: Which Neurotrophin Cocktail Performs Best for Axonal Outgrowth and Is Electrical Stimulation Beneficial?

    by Dominik Schmidbauer, Stefan Fink, Francis Rousset, Hubert Löwenheim, Pascal Senn, Rudolf Glueckert

    Neurotrophins promote neurite outgrowth of auditory neurons and may help closing the gap to cochlear implant (CI) electrodes to enhance electrical hearing. The best concentrations and mix of neurotrophins for this nerve regrowth are unknown. Whether electrical stimulation (ES) during outgrowth is beneficial or may direct axons is another open question. Auditory neuron explant cultures of distinct cochlear turns of 6–7 days old mice were cultured for four days. We tested different concentrations and combinations of BDNF and NT-3 and quantified the numbers and lengths of neurites with an advanced automated analysis. A custom-made 24-well electrical stimulator based on two bulk CIs served to test different ES strategies. Quantification of receptors trkB, trkC, p75NTR, and histological analysis helped to analyze effects. We found 25 ng/mL BDNF to perform best, especially in basal neurons, a negative influence of NT-3 in combined BDNF/NT-3 scenarios, and tonotopic changes in trk and p75NTR receptor stainings. ES largely impeded neurite outgrowth and glia ensheathment in an amplitude-dependent way. Apical neurons showed slight benefits in neurite numbers and length with ES at 10 and 500 µA. We recommend BDNF as a potent drug to enhance the man-machine interface, but CIs should be better activated after nerve regrowth.


  • Open Access

    A potassium channel agonist protects hearing function and promotes outer hair cell survival in a mouse model for age-related hearing loss

    by Barbara Peixoto Pinheiro, Marcus Müller, Michael Bös, Jamil Guezguez, Michael Burnet, Mara Tornincasa, Riccardo Rizzetto, Jean-Francois Rolland, Chiara Liberati, Stefan Lohmer, et al.

    Age-related hearing loss (ARHL) is the most common sensory impairment mainly caused by degeneration of sensory hair cells in the cochlea with no causal medical treatment available. Auditory function and sensory hair cell survival critically depend on the Kv7.4 (KCNQ4) channel, a voltage-gated potassium channel expressed in outer hair cells (OHCs), with its impaired function or reduced activity previously associated with ARHL. Here, we investigated the effect of a potent small-molecule Kv7.4 agonist on ARHL in the senescence-accelerated mouse prone 8 (SAMP8) model. For the first time in vivo, we show that Kv7.4 activation can significantly reduce age-related threshold shifts of auditory brainstem responses as well as OHC loss in the SAMP8 model. Pharmacological activation of Kv7.4 thus holds great potential as a therapeutic approach for ARHL as well as other hearing impairments related to Kv7.4 function.


  • Tübingen: Eberhard Karls Universität Tübingen

    by Hans-Peter Zenner, Hubert Löwenheim

  • Oldenburg: Carl von Ossietzky-Universität Oldenburg

    by Andreas Radeloff, Hubert Löwenheim, Rüdiger Schönfeld

  • Open Access

    The ototoxic effect of locally applied kanamycin and furosemide in guinea pigs

    by Peter Bako, Imre Gerlinger, Stephan Wolpert, Marcus Müller, Hubert Löwenheim


  • Open Access

    ENT Residents Benefit from a Structured Operation Planning Approach in the Training of Functional Endoscopic Sinus Surgery

    by Sven Becker, Phillipp Gonser, Magnus Haas, Martin Sailer, Matthias F. Froelich, Christian Betz, Hubert Löwenheim, Bernhard Hirt, Wieland H. Sommer, Martin Holderried, et al.

    Background and Objectives: Preoperative planning utilizing computed tomographies (CT) is of utmost importance in functional endoscopic sinus surgery (FESS). Frequently, no uniform documentation and planning structures are available to residents in training. Consequently, overall completeness and quality of operation planning may vary greatly. The objective of the present study was to evaluate the impact of a structured operation planning (SOP) approach on the report quality and user convenience during a 4-day sinus surgery course. Materials and Methods: Fifteen participant were requested to plan a FESS procedure based on a CT scan of the paranasal sinuses that exhibited common pathological features, in a conventional manner, using a free text. Afterwards, the participants reevaluated the same scans by means of a specifically designed structured reporting template. Two experienced ENT surgeons assessed the collected conventional operation planning (COP) and SOP methods independently with regard to time requirements, overall quality, and legibility. User convenience data were collected by utilizing visual analogue scales. Results: A significantly greater time expenditure was associated with SOPs (183 s vs. 297 s, p = 0.0003). Yet, legibility (100% vs. 72%, p < 0.0001) and overall completeness (61.3% vs. 22.7%, p < 0.0001) of SOPs was significantly superior to COPs. Additionally, description of highly relevant variants in anatomy and pathologies were outlined in greater detail. User convenience data delineated a significant preference for SOPs (VAS 7.9 vs. 6.9, p = 0.0185). Conclusions: CT-based planning of FESS procedures by residents in training using a structured approach is more time-consuming while producing a superior report quality in terms of detailedness and readability. Consequently, SOP can be considered as a valuable tool in the process of preoperative evaluations, especially within residency.