Islam Mahmoud Abdel Raheem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Islam Mahmoud Abdel Raheem has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Ihab A. Hammad
Alexandria University
3 shared publicationsRania A. Fahmy
Alexandria University
2 shared publicationsSanaa H. Abdelkader
Division of Fixed Prosthodontics Department of Conservative Dentistry Faculty of Dentistry Alexandria University Alexandria Egypt
2 shared publicationsAbeer S. El Hadidi
Alexandria University
1 shared publicationAmr Elsheemy
Assistant Lecturer, Division of Fixed Prosthodontics, Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
1 shared publication- Ihab A. Hammad
Professor, Division of Fixed Prosthodontics, Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
1 shared publication
Latest Publications
- 23 March 2026
- Published by Wiley in Journal of Prosthodontics
Influence of simulated gastric acid on surface roughness and substance loss of different dental veneering porcelains and different surface finishing protocols: An in vitro study
Purpose: Patients with bulimia nervosa or gastroesophageal reflux disease (GERD) are frequently exposed to gastric acid, which may cause tooth demineralization and degradation of dental ceramics. This in vitro study investigated the effect of simulated gastric acid on surface roughness and substance loss of two veneering porcelains subjected to different surface finishing protocols. Materials and Methods: Eighty ceramic discs were fabricated from feldspathic porcelain (VITA VM13; VITA Zahnfabrik) and fluorapatite glass‐ceramic (IPS Emax Ceram; Ivoclar Vivadent) ( n = 40 each). Discs (10 mm × 2 mm) were prepared, fired, and subdivided according to surface finishing: polishing or glazing ( n = 20). Each subgroup was immersed in simulated gastric acid or artificial saliva (control) for 24 h at 37°C ( n = 10). Surface roughness (Ra) was measured before and after immersion using a mechanical profilometer, and surface morphology was examined by scanning electron microscopy (SEM) as two additional specimens per subgroup were prepared to avoid profilometer‐contacted areas. Substance loss was determined by weighing specimens before and after immersion using a digital balance. Data were statistically analyzed with three‐way ANOVA, followed by Tukey's HSD test ( α = 0.05). Results: Both exposure medium and finishing protocol significantly affected surface roughness, with glazed specimens showing smoother surfaces than polished ones ( p < 0.05). Finishing protocol also significantly affected substance loss after immersion in simulated gastric acid ( p < 0.001). No significant difference was found between the two ceramic materials in terms of roughness or weight loss ( p > 0.05). Conclusion: Simulated gastric acid increases surface roughness and induces minor substance loss in veneering porcelains. Glazing provides more protection compared to polishing, maintaining smoother surfaces, and reducing degradation.
- 23 March 2026
- Published by Wiley in Journal of Prosthodontics
Influence of simulated gastric acid on surface roughness and substance loss of different dental veneering porcelains and different surface finishing protocols: An in vitro study
Purpose: Patients with bulimia nervosa or gastroesophageal reflux disease (GERD) are frequently exposed to gastric acid, which may cause tooth demineralization and degradation of dental ceramics. This in vitro study investigated the effect of simulated gastric acid on surface roughness and substance loss of two veneering porcelains subjected to different surface finishing protocols. Materials and Methods: Eighty ceramic discs were fabricated from feldspathic porcelain (VITA VM13; VITA Zahnfabrik) and fluorapatite glass‐ceramic (IPS Emax Ceram; Ivoclar Vivadent) ( n = 40 each). Discs (10 mm × 2 mm) were prepared, fired, and subdivided according to surface finishing: polishing or glazing ( n = 20). Each subgroup was immersed in simulated gastric acid or artificial saliva (control) for 24 h at 37°C ( n = 10). Surface roughness (Ra) was measured before and after immersion using a mechanical profilometer, and surface morphology was examined by scanning electron microscopy (SEM) as two additional specimens per subgroup were prepared to avoid profilometer‐contacted areas. Substance loss was determined by weighing specimens before and after immersion using a digital balance. Data were statistically analyzed with three‐way ANOVA, followed by Tukey's HSD test ( α = 0.05). Results: Both exposure medium and finishing protocol significantly affected surface roughness, with glazed specimens showing smoother surfaces than polished ones ( p < 0.05). Finishing protocol also significantly affected substance loss after immersion in simulated gastric acid ( p < 0.001). No significant difference was found between the two ceramic materials in terms of roughness or weight loss ( p > 0.05). Conclusion: Simulated gastric acid increases surface roughness and induces minor substance loss in veneering porcelains. Glazing provides more protection compared to polishing, maintaining smoother surfaces, and reducing degradation.
- Open Access
- 17 November 2022
- Published by Springer Nature in Research Square
Matrix metalloproteinase-8 level in the peri-implant sulcular fluid around dental implant abutments with different geometries and manufacturing strategies: A randomized controlled trial
Background. The purpose of this clinical trial was to assess soft tissue reaction around custom dental implant abutments by evaluation of Matrix Metalloproteinase-8 (MMP-8) level in peri-implant sulcular fluid (PISF) and clinical parameters. Methods. Thirty participants with missing mandibular first molar were enrolled in this randomized controlled trial. Each participant underwent implant placement following the standard 2-stage surgical protocol. All participants were randomly allocated to one of the two groups; Control Group (n=15): Pre-machined stock titanium abutment, and Study Group (n=15): Custom titanium CAD-CAM abutment. Combined screw- and cement-retained zirconia crowns were used to restore implants. The PISF samples were collected at 1, 3, 6 and 12 months after placement of restorations. MMP-8 level was assessed by Enzyme-Linked ImmunoSorbent Assay. Peri-implant probing depth (PPD), simplified mucosal index (SMI) and modified plaque index (mPI) scores were assessed at all time-points. Crestal bone loss (CBL) was assessed by using bitewing radiographs made at baseline and 12-month time points. Two-way repeated-measures ANOVA and Friedman test were used to analyze data. Results. There was a significant effect of the interaction of time and abutment type where the change in MMP-8 and PPD in CA was higher than in SA. SMI, mPI and CBL recorded no statistical differences between the two groups after one year (P > 0.05). Conclusions. The change in the level of MMP-8 and in PPD after one year is significantly higher in custom abutments. However, this change was of low clinical impact. Trial Registery: the trial was registered in the Pan African Clinical Trial Registry under identification number PACTR201809736563842 (25/ 09/ 2018)
- 17 November 2022
- Published by Springer Nature in Research Square
Open AccessMatrix metalloproteinase-8 level in the peri-implant sulcular fluid around dental implant abutments with different geometries and manufacturing strategies: A randomized controlled trial
Background. The purpose of this clinical trial was to assess soft tissue reaction around custom dental implant abutments by evaluation of Matrix Metalloproteinase-8 (MMP-8) level in peri-implant sulcular fluid (PISF) and clinical parameters. Methods. Thirty participants with missing mandibular first molar were enrolled in this randomized controlled trial. Each participant underwent implant placement following the standard 2-stage surgical protocol. All participants were randomly allocated to one of the two groups; Control Group (n=15): Pre-machined stock titanium abutment, and Study Group (n=15): Custom titanium CAD-CAM abutment. Combined screw- and cement-retained zirconia crowns were used to restore implants. The PISF samples were collected at 1, 3, 6 and 12 months after placement of restorations. MMP-8 level was assessed by Enzyme-Linked ImmunoSorbent Assay. Peri-implant probing depth (PPD), simplified mucosal index (SMI) and modified plaque index (mPI) scores were assessed at all time-points. Crestal bone loss (CBL) was assessed by using bitewing radiographs made at baseline and 12-month time points. Two-way repeated-measures ANOVA and Friedman test were used to analyze data. Results. There was a significant effect of the interaction of time and abutment type where the change in MMP-8 and PPD in CA was higher than in SA. SMI, mPI and CBL recorded no statistical differences between the two groups after one year (P > 0.05). Conclusions. The change in the level of MMP-8 and in PPD after one year is significantly higher in custom abutments. However, this change was of low clinical impact. Trial Registery: the trial was registered in the Pan African Clinical Trial Registry under identification number PACTR201809736563842 (25/ 09/ 2018)
- 29 October 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 132 (3) , 488-495
Cast-free modified digital twin-stage technique for complete mouth rehabilitation: A dental technique
- 29 October 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 132 (3) , 488-495
Cast-free modified digital twin-stage technique for complete mouth rehabilitation: A dental technique
- 1 April 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (4) , 560-564
Fabrication of additively manufactured custom impression copings based on stock abutments
- 1 April 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (4) , 560-564
Fabrication of additively manufactured custom impression copings based on stock abutments
- 1 January 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (1) , 49-54
Fabrication of a CAD-CAM custom healing abutment guided by a conventional dental radiograph for delayed loaded dental implants: A dental technique
- 1 January 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (1) , 49-54
Fabrication of a CAD-CAM custom healing abutment guided by a conventional dental radiograph for delayed loaded dental implants: A dental technique
- 19 July 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (3) , 391-394
A device to facilitate separation of components of combined screw- and cement-retained implant-supported crowns
- 19 July 2021
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (3) , 391-394
A device to facilitate separation of components of combined screw- and cement-retained implant-supported crowns