Catia Maria Fonseca Guerra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Catia Maria Fonseca Guerra has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bruna de Carvalho Farias Vajgel
Universidade Federal de Pernambuco, Brasil
1 shared publication - Camila Agra Souza
Department of Prosthetics and Orofacial Surgery, UFPE-Universidade Federal de Pernambuco, Recife, PE, Brazil
1 shared publication - Luma de Vasconcelos Menezes
Federal University of Pernambuco, Brazil
1 shared publication - Lívia Maria Lopes de Oliveira
Universidade Federal de Pernambuco, Brazil
1 shared publication - Paulo José de Lima1 shared publication
- Renata Cimões
Federal University of Pernambuco, Brazil
1 shared publication
Latest Publications
- 3 March 2021
- Published by Universidade Federal da Paraíba in Revista Brasileira de Ciências da Saúde
- Vol. 25 (1)
[ID 52045] USO, NECESSIDADE E CONSERVAÇÃO DE PRÓTESES DENTÁRIAS EM IDOSOS RESIDENTES EM INSTITUIÇÕES PÚBLICAS DE LONGA PERMANÊNCIA
Objetivo: Conhecer o uso, as condições e a necessidade de prótese dentária entre idosos residentes em instituições públicas de longa permanência (IPLP) para idosos do Município do Recife. Metodologia: Para composição da amostra deste estudo, de um universo de 60 idosos, residentes em IPLP da Cidade do Recife, participaram da amostra 47 idosos, que se enquadraram nos critérios de inclusão, ou seja, se mostraram receptivos a participar da pesquisa e no máximo apresentavam comprometimento cognitivo que não prejudicasse as funções de linguagem e memória. Resultados: Na amostra a idade dos pesquisados variou de 52 a 87 anos, com uma média de 65,00 anos, sendo que 34% eram do sexo masculino e 66% do sexo feminino. O estudo revelou que 70,2% usavam prótese no arco superior e 48,9% no arco inferior. Apesar de 72,7% informarem o uso de diferentes meios para a higiene oral, a presença de biofilme foi detectada em 74,4% das próteses. Grande parte dos idosos (66,0%) necessitava de substituição das próteses, consideradas inadequadas ou para reabilitação. Conclusão: Conclui-se que o idoso não consegue perceber as condições precárias da prótese, existindo a necessidade de maior atenção à saúde bucal do idoso institucionalizado e a elaboração de programas preventivos e educativos voltados para essa parcela da população.
- 3 March 2021
- Published by Universidade Federal da Paraíba in Revista Brasileira de Ciências da Saúde
- Vol. 25 (1)
[ID 52045] USO, NECESSIDADE E CONSERVAÇÃO DE PRÓTESES DENTÁRIAS EM IDOSOS RESIDENTES EM INSTITUIÇÕES PÚBLICAS DE LONGA PERMANÊNCIA
Objetivo: Conhecer o uso, as condições e a necessidade de prótese dentária entre idosos residentes em instituições públicas de longa permanência (IPLP) para idosos do Município do Recife. Metodologia: Para composição da amostra deste estudo, de um universo de 60 idosos, residentes em IPLP da Cidade do Recife, participaram da amostra 47 idosos, que se enquadraram nos critérios de inclusão, ou seja, se mostraram receptivos a participar da pesquisa e no máximo apresentavam comprometimento cognitivo que não prejudicasse as funções de linguagem e memória. Resultados: Na amostra a idade dos pesquisados variou de 52 a 87 anos, com uma média de 65,00 anos, sendo que 34% eram do sexo masculino e 66% do sexo feminino. O estudo revelou que 70,2% usavam prótese no arco superior e 48,9% no arco inferior. Apesar de 72,7% informarem o uso de diferentes meios para a higiene oral, a presença de biofilme foi detectada em 74,4% das próteses. Grande parte dos idosos (66,0%) necessitava de substituição das próteses, consideradas inadequadas ou para reabilitação. Conclusão: Conclui-se que o idoso não consegue perceber as condições precárias da prótese, existindo a necessidade de maior atenção à saúde bucal do idoso institucionalizado e a elaboração de programas preventivos e educativos voltados para essa parcela da população.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 68
Quality of models supplied to dental laboratories for the fabrication of partial removable denture framework
Objective The aim of this study was to evaluate the models and plannings of metallic framework of removable partial prosthesis sent to dental laboratories in the city of Recife. Methods: The physical and technical conditions of plaster models were sent by the dentists to 4 dental laboratories. All models were examined, photographed and recorded on a form according to the research objective. Results: A total number of 235 models sent by dental surgeons were used to prepare the metallic structure, in which none of the models presented surveying nor the path of insertion. Out of the 235 models, 41 (17.44%) presented serious failures, such as positive and negative bubbles, broken dental elements, direct retainers and damaged edentulous areas. With respect to the planning, only 22 (9.35%) models were presented with the metallic framework planning, but in an unsatisfactory way. Regarding mouth preparation, no model presented a guide plane, and only 6.8% of models had rests seats, but incorrectly prepared. Conclusion: The models evaluated presented poor quality, lack of planning and no mouth preparation. This shows the need for dental surgeons to be aware of the appropriate prosthesis models and plannings in order to ensure a satisfactory and long-term rehabilitation of the patient, as well as preserving the remaining mouth structures.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 68
Open AccessQuality of models supplied to dental laboratories for the fabrication of partial removable denture framework
Objective The aim of this study was to evaluate the models and plannings of metallic framework of removable partial prosthesis sent to dental laboratories in the city of Recife. Methods: The physical and technical conditions of plaster models were sent by the dentists to 4 dental laboratories. All models were examined, photographed and recorded on a form according to the research objective. Results: A total number of 235 models sent by dental surgeons were used to prepare the metallic structure, in which none of the models presented surveying nor the path of insertion. Out of the 235 models, 41 (17.44%) presented serious failures, such as positive and negative bubbles, broken dental elements, direct retainers and damaged edentulous areas. With respect to the planning, only 22 (9.35%) models were presented with the metallic framework planning, but in an unsatisfactory way. Regarding mouth preparation, no model presented a guide plane, and only 6.8% of models had rests seats, but incorrectly prepared. Conclusion: The models evaluated presented poor quality, lack of planning and no mouth preparation. This shows the need for dental surgeons to be aware of the appropriate prosthesis models and plannings in order to ensure a satisfactory and long-term rehabilitation of the patient, as well as preserving the remaining mouth structures.