Queenie Chan
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Queenie Chan has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Weitian Chen
Department of Imaging and Interventional Radiology The Chinese University of Hong Kong Hong Kong China
4 shared publications - Jian He
Department of Nuclear Medicine, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, Jiangsu Province, China.
2 shared publications - Qi Yong Hemis Ai
Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
2 shared publications - Tiffany Y. So
Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong SAR, China
2 shared publications - Ziqiang Yu
Department of Imaging and Interventional Radiology The Chinese University of Hong Kong Hong Kong China
2 shared publications - Alexander Yuk Lun Lau
Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong SAR, China
1 shared publication
Latest Publications
- Open Access
- 23 November 2026
- Published by Wiley in Magnetic Resonance in Medicine
Pulsed Off‐Resonance Saturation for Macromolecular Proton Fraction‐Weighted Contrast With Intrinsic Flow Attenuation
Purpose: To develop a pulsed off‐resonance magnetization transfer (MT) preparation module that achieves intrinsic flow attenuation while enabling efficient macromolecular proton fraction (MPF)‐weighted contrast that specific to macromolecular pool. Methods: In the proposed MPF‐SPS (MPF‐weighted contrast mapping using short pulsed saturation) approach, repetitive short off‐resonance RF pulses are applied in conjunction with spoiler gradients, enabling simultaneous MT contrast generation in stationary tissue and intrinsic blood signal attenuation. An MPF‐weighted relaxation rate, , is derived that is specific to the macromolecular pool and independent of the free water pool. An off‐resonance Extended Phase Graph (EPG) framework incorporating MT effects was developed for efficient parameter optimization. The proposed approach is validated with EPG‐based two‐pool simulations, phantom, and in vivo brain studies at 3.0 T. Results: Simulations showed that the off‐resonance EPG‐MT framework closely agrees with two‐pool Bloch–McConnell simulations while requiring substantially less computation time. This efficient framework was used to optimize the sequence parameters, confirming that intrinsic flow attenuation effectively reduces partial‐volume effects caused by intravascular signal contamination. Both simulations and phantom experiments demonstrated that MPF‐SPS provides maps that are insensitive to free‐water‐pool parameters. In vivo brain imaging further demonstrated that the proposed method generates maps with MPF‐weighted contrast and intrinsic flow attenuation. Conclusion: A novel MPF‐weighted contrast imaging method using pulsed off‐resonance MT preparation with intrinsic flow attenuation is proposed, providing a technical basis for future MPF‐sensitive vessel wall imaging.
- 23 November 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessPulsed Off‐Resonance Saturation for Macromolecular Proton Fraction‐Weighted Contrast With Intrinsic Flow Attenuation
Purpose: To develop a pulsed off‐resonance magnetization transfer (MT) preparation module that achieves intrinsic flow attenuation while enabling efficient macromolecular proton fraction (MPF)‐weighted contrast that specific to macromolecular pool. Methods: In the proposed MPF‐SPS (MPF‐weighted contrast mapping using short pulsed saturation) approach, repetitive short off‐resonance RF pulses are applied in conjunction with spoiler gradients, enabling simultaneous MT contrast generation in stationary tissue and intrinsic blood signal attenuation. An MPF‐weighted relaxation rate, , is derived that is specific to the macromolecular pool and independent of the free water pool. An off‐resonance Extended Phase Graph (EPG) framework incorporating MT effects was developed for efficient parameter optimization. The proposed approach is validated with EPG‐based two‐pool simulations, phantom, and in vivo brain studies at 3.0 T. Results: Simulations showed that the off‐resonance EPG‐MT framework closely agrees with two‐pool Bloch–McConnell simulations while requiring substantially less computation time. This efficient framework was used to optimize the sequence parameters, confirming that intrinsic flow attenuation effectively reduces partial‐volume effects caused by intravascular signal contamination. Both simulations and phantom experiments demonstrated that MPF‐SPS provides maps that are insensitive to free‐water‐pool parameters. In vivo brain imaging further demonstrated that the proposed method generates maps with MPF‐weighted contrast and intrinsic flow attenuation. Conclusion: A novel MPF‐weighted contrast imaging method using pulsed off‐resonance MT preparation with intrinsic flow attenuation is proposed, providing a technical basis for future MPF‐sensitive vessel wall imaging.
- Open Access
- 28 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (15) , 2368
Elevated Corpus Callosum T1rho Reflects Disease Burden and Structural Atrophy in Multiple Sclerosis
Background/Objectives: Corpus callosum atrophy is a well recognized feature of multiple sclerosis (MS), which has been associated with disease duration and severity. Quantitative T1rho imaging is an MRI technique sensitive to microstructural tissue alterations, but the T1rho characteristics of the corpus callosum in MS remain largely unexplored. This study aimed to characterize T1rho in the corpus callosum in MS patients, and examine relationships between T1rho values, callosal atrophy, and clinical and imaging markers of disease burden. Method: Thirty patients with relapsing-remitting multiple sclerosis (RRMS) and 30 healthy controls underwent T1rho imaging. T1rho values were measured in the genu, body, splenium, and whole corpus callosum. Comparisons between patient and control groups were performed using the Mann–Whitney U test and the independent samples t-test, and Pearson’s and Spearman’s correlation coefficients were used to evaluate the correlation between imaging and clinical measures. Results: T1rho values were significantly increased across all corpus callosum subregions in patients compared to controls. Corpus callosum T1rho values showed correlations with disease duration (r = 0.375–0.408, p < 0.041), lesion load (r = 0.726–0.810, p < 0.001), and the corpus callosum index (CCI) (r = −0.731–−0.640, p < 0.001). Conclusions: T1rho values are elevated in the corpus callosum of MS patients and associated with disease duration, lesion load, and callosal atrophy.
- 28 July 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (15) , 2368
Open AccessElevated Corpus Callosum T1rho Reflects Disease Burden and Structural Atrophy in Multiple Sclerosis
Background/Objectives: Corpus callosum atrophy is a well recognized feature of multiple sclerosis (MS), which has been associated with disease duration and severity. Quantitative T1rho imaging is an MRI technique sensitive to microstructural tissue alterations, but the T1rho characteristics of the corpus callosum in MS remain largely unexplored. This study aimed to characterize T1rho in the corpus callosum in MS patients, and examine relationships between T1rho values, callosal atrophy, and clinical and imaging markers of disease burden. Method: Thirty patients with relapsing-remitting multiple sclerosis (RRMS) and 30 healthy controls underwent T1rho imaging. T1rho values were measured in the genu, body, splenium, and whole corpus callosum. Comparisons between patient and control groups were performed using the Mann–Whitney U test and the independent samples t-test, and Pearson’s and Spearman’s correlation coefficients were used to evaluate the correlation between imaging and clinical measures. Results: T1rho values were significantly increased across all corpus callosum subregions in patients compared to controls. Corpus callosum T1rho values showed correlations with disease duration (r = 0.375–0.408, p < 0.041), lesion load (r = 0.726–0.810, p < 0.001), and the corpus callosum index (CCI) (r = −0.731–−0.640, p < 0.001). Conclusions: T1rho values are elevated in the corpus callosum of MS patients and associated with disease duration, lesion load, and callosal atrophy.
- Open Access
- 5 August 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2745-2757
Utilizing 3D fast spin echo anatomical imaging to reduce the number of contrast preparations in T1ρ$ {T}_{1\rho } $ quantification of knee cartilage using learning‐based methodsPurpose: To propose and evaluate an accelerated quantification method that combines ‐weighted fast spin echo (FSE) images and proton density (PD)‐weighted anatomical FSE images, leveraging deep learning models for mapping. The goal is to reduce scan time and facilitate integration into routine clinical workflows for osteoarthritis (OA) assessment.Methods: This retrospective study utilized MRI data from 40 participants (30 OA patients and 10 healthy volunteers). A volume of PD‐weighted anatomical FSE images and a volume of ‐weighted images acquired at a non‐zero spin‐lock time were used as input to train deep learning models, including a 2D U‐Net and a multi‐layer perceptron (MLP). maps generated by these models were compared with ground truth maps derived from a traditional non‐linear least squares (NLLS) fitting method using four ‐weighted images. Evaluation metrics included mean absolute error (MAE), mean absolute percentage error (MAPE), regional error (RE), and regional percentage error (RPE).Results: The best‐performed deep learning models achieved RPEs below 5% across all evaluated scenarios. This performance was consistent even in reduced acquisition settings that included only one PD‐weighted image and one ‐weighted image, where NLLS methods cannot be applied. Furthermore, the results were comparable to those obtained with NLLS when longer acquisitions with four ‐weighted images were used.Conclusion: The proposed approach enables efficient mapping using PD‐weighted anatomical images, reducing scan time while maintaining clinical standards. This method has the potential to facilitate the integration of quantitative MRI techniques into routine clinical practice, benefiting OA diagnosis and monitoring.
- 5 August 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (6) , 2745-2757
Open AccessUtilizing 3D fast spin echo anatomical imaging to reduce the number of contrast preparations in T1ρ$ {T}_{1\rho } $ quantification of knee cartilage using learning‐based methodsPurpose: To propose and evaluate an accelerated quantification method that combines ‐weighted fast spin echo (FSE) images and proton density (PD)‐weighted anatomical FSE images, leveraging deep learning models for mapping. The goal is to reduce scan time and facilitate integration into routine clinical workflows for osteoarthritis (OA) assessment.Methods: This retrospective study utilized MRI data from 40 participants (30 OA patients and 10 healthy volunteers). A volume of PD‐weighted anatomical FSE images and a volume of ‐weighted images acquired at a non‐zero spin‐lock time were used as input to train deep learning models, including a 2D U‐Net and a multi‐layer perceptron (MLP). maps generated by these models were compared with ground truth maps derived from a traditional non‐linear least squares (NLLS) fitting method using four ‐weighted images. Evaluation metrics included mean absolute error (MAE), mean absolute percentage error (MAPE), regional error (RE), and regional percentage error (RPE).Results: The best‐performed deep learning models achieved RPEs below 5% across all evaluated scenarios. This performance was consistent even in reduced acquisition settings that included only one PD‐weighted image and one ‐weighted image, where NLLS methods cannot be applied. Furthermore, the results were comparable to those obtained with NLLS when longer acquisitions with four ‐weighted images were used.Conclusion: The proposed approach enables efficient mapping using PD‐weighted anatomical images, reducing scan time while maintaining clinical standards. This method has the potential to facilitate the integration of quantitative MRI techniques into routine clinical practice, benefiting OA diagnosis and monitoring.
- 29 October 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (12) , 2339-2344
Quantitative T1ρ MRI of the Head and Neck Discriminates Carcinoma and Benign Hyperplasia in the Nasopharynx
BACKGROUND AND PURPOSE: T1ρ imaging is a new quantitative MR imaging pulse sequence with the potential to discriminate between malignant and benign tissue. In this study, we evaluated the capability of T1ρ imaging to characterize tissue by applying T1ρ imaging to malignant and benign tissue in the nasopharynx and to normal tissue in the head and neck. MATERIALS AND METHODS: Participants with undifferentiated nasopharyngeal carcinoma and benign hyperplasia of the nasopharynx prospectively underwent T1ρ imaging. T1ρ measurements obtained from the histogram analysis for nasopharyngeal carcinoma in 43 participants were compared with those for benign hyperplasia and for normal tissue (brain, muscle, and parotid glands) in 41 participants using the Mann-Whitney U test. The area under the curve of significant T1ρ measurements was calculated and compared using receiver operating characteristic analysis and the Delong test, respectively. A P < . 05 indicated statistical significance. RESULTS: There were significant differences in T1ρ measurements between nasopharyngeal carcinoma and benign hyperplasia and between nasopharyngeal carcinoma and normal tissue (all, P < . 05). Compared with benign hyperplasia, nasopharyngeal carcinoma showed a lower T1ρ mean (62.14 versus 65.45 × ms), SD (12.60 versus 17.73 × ms), and skewness (0.61 versus 0.76) (all P < .05), but no difference in kurtosis (P = . 18). The T1ρ SD showed the highest area under the curve of 0.95 compared with the T1ρ mean (area under the curve = 0.72) and T1ρ skewness (area under the curve = 0.72) for discriminating nasopharyngeal carcinoma and benign hyperplasia (all, P < .05). CONCLUSIONS: Quantitative T1ρ imaging has the potential to discriminate malignant from benign and normal tissue in the head and neck.
- 29 October 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (12) , 2339-2344
Quantitative T1ρ MRI of the Head and Neck Discriminates Carcinoma and Benign Hyperplasia in the Nasopharynx
BACKGROUND AND PURPOSE: T1ρ imaging is a new quantitative MR imaging pulse sequence with the potential to discriminate between malignant and benign tissue. In this study, we evaluated the capability of T1ρ imaging to characterize tissue by applying T1ρ imaging to malignant and benign tissue in the nasopharynx and to normal tissue in the head and neck. MATERIALS AND METHODS: Participants with undifferentiated nasopharyngeal carcinoma and benign hyperplasia of the nasopharynx prospectively underwent T1ρ imaging. T1ρ measurements obtained from the histogram analysis for nasopharyngeal carcinoma in 43 participants were compared with those for benign hyperplasia and for normal tissue (brain, muscle, and parotid glands) in 41 participants using the Mann-Whitney U test. The area under the curve of significant T1ρ measurements was calculated and compared using receiver operating characteristic analysis and the Delong test, respectively. A P < . 05 indicated statistical significance. RESULTS: There were significant differences in T1ρ measurements between nasopharyngeal carcinoma and benign hyperplasia and between nasopharyngeal carcinoma and normal tissue (all, P < . 05). Compared with benign hyperplasia, nasopharyngeal carcinoma showed a lower T1ρ mean (62.14 versus 65.45 × ms), SD (12.60 versus 17.73 × ms), and skewness (0.61 versus 0.76) (all P < .05), but no difference in kurtosis (P = . 18). The T1ρ SD showed the highest area under the curve of 0.95 compared with the T1ρ mean (area under the curve = 0.72) and T1ρ skewness (area under the curve = 0.72) for discriminating nasopharyngeal carcinoma and benign hyperplasia (all, P < .05). CONCLUSIONS: Quantitative T1ρ imaging has the potential to discriminate malignant from benign and normal tissue in the head and neck.
- Open Access
- 22 January 2020
- Published by Springer Nature in Cancer Imaging
- Vol. 20 (1) , 1-9
Intravoxel incoherent motion and ADC measurements for differentiating benign from malignant thyroid nodules: utilizing the most repeatable region of interest delineation at 3.0 T
Background: There is a growing need for a reproducible and effective imaging method for the quantitative differentiation of benign from malignant thyroid nodules. This study aimed to investigate the performances of intravoxel incoherent motion (IVIM) parameters and the apparent diffusion coefficient (ADC) in differentiating malignant from benign thyroid nodules derived from the most repeatable region of interest (ROI) delineation. Methods: Forty-three patients with 46 pathologically confirmed thyroid nodules underwent diffusion-weighted imaging (DWI) with 8 b values. Two observers measured the intravoxel incoherent motion (IVIM) parameters (D, f and D*) and the apparent diffusion coefficient (ADC), ADC600 and ADC990 values using whole-lesion (W-L) ROI and IVIM parameters using single-section (S-S) ROI delineation. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the intra- and interobserver variability. The diagnostic performance of these parameters was evaluated by generating receiver operating characteristic (ROC) curves. Results: The ICC values of all IVIM with W-L ROI delineation were higher than those with S-S ROI delineation, and excellent intra- and interobserver reproducibility was obtained. According to the Bland-Altman plots, the 95% limits of agreement of the IVIM parameters determined by the W-L ROIs revealed smaller absolute intra- and interobserver variability than those determined by S-S ROIs. The D and ADC600 values obtained from the W-L ROIs were the most powerful parameters in differentiating benign from the malignant nodules [area under the ROC curve = 0.962 and 0.970, P = 0.771]. Conclusions: The W-L ROI of the thyroid was considered an effective method for obtaining IVIM measurements with excellent reproducibility for differentiating benign from malignant nodules.
- 22 January 2020
- Published by Springer Nature in Cancer Imaging
- Vol. 20 (1) , 1-9
Open AccessIntravoxel incoherent motion and ADC measurements for differentiating benign from malignant thyroid nodules: utilizing the most repeatable region of interest delineation at 3.0 T
Background: There is a growing need for a reproducible and effective imaging method for the quantitative differentiation of benign from malignant thyroid nodules. This study aimed to investigate the performances of intravoxel incoherent motion (IVIM) parameters and the apparent diffusion coefficient (ADC) in differentiating malignant from benign thyroid nodules derived from the most repeatable region of interest (ROI) delineation. Methods: Forty-three patients with 46 pathologically confirmed thyroid nodules underwent diffusion-weighted imaging (DWI) with 8 b values. Two observers measured the intravoxel incoherent motion (IVIM) parameters (D, f and D*) and the apparent diffusion coefficient (ADC), ADC600 and ADC990 values using whole-lesion (W-L) ROI and IVIM parameters using single-section (S-S) ROI delineation. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the intra- and interobserver variability. The diagnostic performance of these parameters was evaluated by generating receiver operating characteristic (ROC) curves. Results: The ICC values of all IVIM with W-L ROI delineation were higher than those with S-S ROI delineation, and excellent intra- and interobserver reproducibility was obtained. According to the Bland-Altman plots, the 95% limits of agreement of the IVIM parameters determined by the W-L ROIs revealed smaller absolute intra- and interobserver variability than those determined by S-S ROIs. The D and ADC600 values obtained from the W-L ROIs were the most powerful parameters in differentiating benign from the malignant nodules [area under the ROC curve = 0.962 and 0.970, P = 0.771]. Conclusions: The W-L ROI of the thyroid was considered an effective method for obtaining IVIM measurements with excellent reproducibility for differentiating benign from malignant nodules.
- 28 April 2018
- Published by Elsevier in Clinical Radiology
- Vol. 73 (7) , 678.e7-678.e12
An optimised repetition time (TR) for cine imaging of uterine peristalsis on 3 T MRI
- 28 April 2018
- Published by Elsevier in Clinical Radiology
- Vol. 73 (7) , 678.e7-678.e12
An optimised repetition time (TR) for cine imaging of uterine peristalsis on 3 T MRI
- Open Access
- 18 May 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (6) , 1397-1404
Optimized approach to cine MRI of uterine peristalsis
Purpose To determine the optimal slice thickness, playback rate, and scan time for uterine peristalsis with 3.0T magnetic resonance imaging (MRI). Materials and Methods In all, 23 young female volunteers underwent a 3.0T MRI scan with different slice thicknesses of 3 mm (Cine3mm), 5 mm (Cine5mm), and 7 mm (Cine7mm) for 6 minutes. Subjective image quality score, signal‐to‐noise ratios (SNRs), and contrast‐to‐noise ratios (CNRs) of those MR images were evaluated by two radiologists independently. The number, intensity, and direction of uterine peristalsis with different thickness were compared at various playback rates. Also, the peristalsis frequency was counted and compared in different acquisition durations (1–6 minutes). Results The subjective image quality score, peristalsis number, and intensity were significantly higher in Cine7mm and Cine5mm than Cine3mm (P < 0.05), while the SNRs and CNRs of Cine7mm were significantly higher than Cine3mm (P < 0.05). Peristalsis numbers did not differ significantly at different playback rates with the same slice thickness (P = 0.548–0.962). However, peristalsis intensity at 12×, and 15× was significantly greater than that at 8× the actual speed for Cine7mm and Cine5mm (P < 0.05). The peristalsis frequency at 3, 4, 5, 6 minutes was significantly higher than that at 1 minute and 2 minutes (P < 0.05). Conclusion We recommend a slice thickness of 5 mm or 7 mm and a scan time of 3 minutes for uterine peristalsis with 3.0T MRI, and a playback rate of 12× or 15× the actual speed for peristalsis observation. J. Magn. Reson. Imaging 2016;44:1397–1404.
- 18 May 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (6) , 1397-1404
Open AccessOptimized approach to cine MRI of uterine peristalsis
Purpose To determine the optimal slice thickness, playback rate, and scan time for uterine peristalsis with 3.0T magnetic resonance imaging (MRI). Materials and Methods In all, 23 young female volunteers underwent a 3.0T MRI scan with different slice thicknesses of 3 mm (Cine3mm), 5 mm (Cine5mm), and 7 mm (Cine7mm) for 6 minutes. Subjective image quality score, signal‐to‐noise ratios (SNRs), and contrast‐to‐noise ratios (CNRs) of those MR images were evaluated by two radiologists independently. The number, intensity, and direction of uterine peristalsis with different thickness were compared at various playback rates. Also, the peristalsis frequency was counted and compared in different acquisition durations (1–6 minutes). Results The subjective image quality score, peristalsis number, and intensity were significantly higher in Cine7mm and Cine5mm than Cine3mm (P < 0.05), while the SNRs and CNRs of Cine7mm were significantly higher than Cine3mm (P < 0.05). Peristalsis numbers did not differ significantly at different playback rates with the same slice thickness (P = 0.548–0.962). However, peristalsis intensity at 12×, and 15× was significantly greater than that at 8× the actual speed for Cine7mm and Cine5mm (P < 0.05). The peristalsis frequency at 3, 4, 5, 6 minutes was significantly higher than that at 1 minute and 2 minutes (P < 0.05). Conclusion We recommend a slice thickness of 5 mm or 7 mm and a scan time of 3 minutes for uterine peristalsis with 3.0T MRI, and a playback rate of 12× or 15× the actual speed for peristalsis observation. J. Magn. Reson. Imaging 2016;44:1397–1404.