Wei Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wei Ding has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jing Cui
Sichuan Univ, West China Hosp, Dept Orthoped Surg, Chengdu, Peoples R China
1 shared publication - Jing-Cong Luo
Laboratory of Stem Cell and Tissue Engineering, Orthopedic Research Institute, State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University and Collaborative Innovation Center of Biotherapy, Chengdu, Sichuan, China
1 shared publication - Liang-Ju Ning
Sichuan Univ, West China Hosp, Dept Orthoped Surg, Chengdu, Peoples R China
1 shared publication - Shu-Kun He
Department of Orthopeadics, Sichuan University West China Hospital, Chengdu, 610041, CHINA
1 shared publication - Ting-Wu Qin
Department of Orthopedic Surgery and Orthopedic Research Institute, Stem Cell and Tissue Engineering Research Center, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, PR China
1 shared publication - Xuan Yao
Department of clinical Hematologyy, Faculty of Laboratory medicine, Army Medical University, Chongqing, 400038, CHINA
1 shared publication
Latest Publications
- 23 December 2020
- Published by IOP Publishing in Biomedical Materials
- Vol. 16 (1) , 015029
Influence of the integrity of tendinous membrane and fascicle on biomechanical characteristics of tendon-derived scaffolds
The biomechanical characteristics of tendon grafts is essential for tendon reconstructive surgery due to its great role in providing a good mechanical environment for tendon healing and regeneration. In our previous studies, the decellularized tendon slices (DTSs) and decellularized bovine tendon sheets (DBTSs) scaffolds were successfully developed. However, the influence of the integrity of tendinous membrane (endotenon and epitenon) and fascicle on biomechanical characteristics of these two scaffolds was not investigated. In this study, we assessed the integrity of tendinous membrane and fascicle of the tendon derived scaffolds and its effect on the biomechanical characteristics. The results of histological staining indicated that the DBTSs had complete endotenon and epitenon, while DTSs had no epitenon at all, only part of endotenon was remained. Furthermore, the DBTSs, and DTSs with thickness of 900 μ m had complete fascicles, while DTSs with thickness less than 600 μ m had almost no complete fascicles. The fibrous configuration of epitenon was well-preserved in the surface of the DBTSs but the surface ultrastructure of the DTSs was aligned collagen fibers based on scanning electron microscopy examination. The results of transmission electron microscopy showed that there was no significant difference between the DBTSs and DTSs. Mechanically, the DBTSs and DTSs with thickness of 900 μ m showed similar ultimate tensile strength and stiffness to native tendon segments (NTSs). The strain at break and suture retention strength of the DBTSs showed much higher than that of the DTSs (p < 0.05). Additionally, the DBTSs showed higher ultimate load than the DTSs when these scaffolds were sutured with NTSs (p < 0.05) through the modified Kessler technique based on a uniaxial tensile test. This study demonstrated that DTSs may be used as a patch for reinforcing tendon repair, while DBTSs may be used as a bridge for reconstructing tendon defects.
- 23 December 2020
- Published by IOP Publishing in Biomedical Materials
- Vol. 16 (1) , 015029
Influence of the integrity of tendinous membrane and fascicle on biomechanical characteristics of tendon-derived scaffolds
The biomechanical characteristics of tendon grafts is essential for tendon reconstructive surgery due to its great role in providing a good mechanical environment for tendon healing and regeneration. In our previous studies, the decellularized tendon slices (DTSs) and decellularized bovine tendon sheets (DBTSs) scaffolds were successfully developed. However, the influence of the integrity of tendinous membrane (endotenon and epitenon) and fascicle on biomechanical characteristics of these two scaffolds was not investigated. In this study, we assessed the integrity of tendinous membrane and fascicle of the tendon derived scaffolds and its effect on the biomechanical characteristics. The results of histological staining indicated that the DBTSs had complete endotenon and epitenon, while DTSs had no epitenon at all, only part of endotenon was remained. Furthermore, the DBTSs, and DTSs with thickness of 900 μ m had complete fascicles, while DTSs with thickness less than 600 μ m had almost no complete fascicles. The fibrous configuration of epitenon was well-preserved in the surface of the DBTSs but the surface ultrastructure of the DTSs was aligned collagen fibers based on scanning electron microscopy examination. The results of transmission electron microscopy showed that there was no significant difference between the DBTSs and DTSs. Mechanically, the DBTSs and DTSs with thickness of 900 μ m showed similar ultimate tensile strength and stiffness to native tendon segments (NTSs). The strain at break and suture retention strength of the DBTSs showed much higher than that of the DTSs (p < 0.05). Additionally, the DBTSs showed higher ultimate load than the DTSs when these scaffolds were sutured with NTSs (p < 0.05) through the modified Kessler technique based on a uniaxial tensile test. This study demonstrated that DTSs may be used as a patch for reinforcing tendon repair, while DBTSs may be used as a bridge for reconstructing tendon defects.