Ramy Abdlaty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ramy Abdlaty has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Ahmed M. Awadallah
Department of Biomedical Engineering, Military Technical College, Cairo, Egypt
4 shared publicationsJoseph Hayward
Juravinski Cancer Centre, Hamilton Health Sciences
3 shared publicationsMohamed A. Abbass
Department of Biomedical Engineering, Military Technical College, Cairo, Egypt
3 shared publications- Qiyin Fang
School of Biomedical Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada
3 shared publications Lilian Doerwald-Munoz
Juravinski Cancer Centre, Hamilton Health Sciences
2 shared publicationsQiyin Fang
Engineering Physics, McMaster University
2 shared publications
Latest Publications
- 13 October 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-15
Machine learning-assisted monitoring of radiofrequency ablation in hepatic tumors using spectral traces
- 13 October 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-15
Machine learning-assisted monitoring of radiofrequency ablation in hepatic tumors using spectral traces
- Open Access
- 10 August 2026
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 16, 1882432
Reliability of radiotherapist assessment for radiation induced skin-toxicity: investigational study
Purpose: Enhancing the quality of radiotherapy for skin cancer requires systematic evaluation of radiation-induced skin toxicity, particularly acute toxicity, which affects ~90% of patients receiving ionizing radiation. This study assessed the reliability of a newly developed visual grading tool, the Clinician Erythema Assessment–Radiation Therapy (CEA-RT), designed to help radiation clinicians evaluate early radiation dermatitis. Methods and materials: The CEA-RT tool utilizes a 5-point scale. Its reliability was evaluated by analyzing intra-rater and inter-rater agreement among clinicians, as well as its concordance with an expert reference standard against a reference standard. The assessment was conducted using digital images. Results: The study’s results showed high intra-rater reliability, with 98% of scores falling within ±1 grade and consistent grading for regions of interest (ROI). However, inter-rater agreement was only fair, indicating variability among different clinicians. Concordance with an expert reference standard against a reference standard was moderate, with 25–30% of therapists achieving high concordance and over 50% showing moderate agreement. Conclusions: The findings support the CEA-RT scale as a reliable tool for individual use. However, study limitations included variable time gaps between sessions, recall bias, fatigue, and reliance on digital images. The results emphasize the need for additional training, in vivo validation, and inclusion of diverse skin types to improve overall accuracy and applicability.
- 10 August 2026
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 16, 1882432
Open AccessReliability of radiotherapist assessment for radiation induced skin-toxicity: investigational study
Purpose: Enhancing the quality of radiotherapy for skin cancer requires systematic evaluation of radiation-induced skin toxicity, particularly acute toxicity, which affects ~90% of patients receiving ionizing radiation. This study assessed the reliability of a newly developed visual grading tool, the Clinician Erythema Assessment–Radiation Therapy (CEA-RT), designed to help radiation clinicians evaluate early radiation dermatitis. Methods and materials: The CEA-RT tool utilizes a 5-point scale. Its reliability was evaluated by analyzing intra-rater and inter-rater agreement among clinicians, as well as its concordance with an expert reference standard against a reference standard. The assessment was conducted using digital images. Results: The study’s results showed high intra-rater reliability, with 98% of scores falling within ±1 grade and consistent grading for regions of interest (ROI). However, inter-rater agreement was only fair, indicating variability among different clinicians. Concordance with an expert reference standard against a reference standard was moderate, with 25–30% of therapists achieving high concordance and over 50% showing moderate agreement. Conclusions: The findings support the CEA-RT scale as a reliable tool for individual use. However, study limitations included variable time gaps between sessions, recall bias, fatigue, and reliance on digital images. The results emphasize the need for additional training, in vivo validation, and inclusion of diverse skin types to improve overall accuracy and applicability.
- 26 February 2025
- Published by Egyptian Knowledge Bank in Journal of Engineering Science and Military Technologies
Noninvasive Spectral Monitoring for Radiation Therapy Induced Skin-Inflammation
Toward high-quality radiotherapy treatment for skin cancer, skin toxicity necessitates precise monitoring. The monitoring procedure targets the investigation of the development of acute skin toxicity due to radiation exposure. Skin toxicity is a common symptom in 90% of the patients who receive ionizing radiation for cancer treatment. This work presents an investigation of using hyperspectral imaging (HSI) to quantify skin toxicity inflammatory response (skin erythema). This investigation used expert visual assessment (VA), optical imaging, and HSI to monitor skin erythema induced in 5 recruited skin cancer patients referred to radiotherapy for treatment. Erythema indices were computed using Dawson’s formulae that were applied to the captured data via HSI and the results were compared to VA. The study’s results showed that the computed relative erythema index is a highly correlated objective measure to VA. In addition, this study provided a piece of evidence that hyperspectral imaging beats optical imaging in classifying skin erythema in terms of precision and specificity. Consequently, HSI becomes a potential opportunity for investigating the toxicity symptoms of skin toxicity due to a variety of dermatological diseases.
- 26 February 2025
- Published by Egyptian Knowledge Bank in Journal of Engineering Science and Military Technologies
Noninvasive Spectral Monitoring for Radiation Therapy Induced Skin-Inflammation
Toward high-quality radiotherapy treatment for skin cancer, skin toxicity necessitates precise monitoring. The monitoring procedure targets the investigation of the development of acute skin toxicity due to radiation exposure. Skin toxicity is a common symptom in 90% of the patients who receive ionizing radiation for cancer treatment. This work presents an investigation of using hyperspectral imaging (HSI) to quantify skin toxicity inflammatory response (skin erythema). This investigation used expert visual assessment (VA), optical imaging, and HSI to monitor skin erythema induced in 5 recruited skin cancer patients referred to radiotherapy for treatment. Erythema indices were computed using Dawson’s formulae that were applied to the captured data via HSI and the results were compared to VA. The study’s results showed that the computed relative erythema index is a highly correlated objective measure to VA. In addition, this study provided a piece of evidence that hyperspectral imaging beats optical imaging in classifying skin erythema in terms of precision and specificity. Consequently, HSI becomes a potential opportunity for investigating the toxicity symptoms of skin toxicity due to a variety of dermatological diseases.
- 22 September 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 305, 123363
Custom Hyperspectral Imaging System Reveals Unique Spectral Signatures of Heart, Kidney, and Liver Tissues
- 22 September 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 305, 123363
Custom Hyperspectral Imaging System Reveals Unique Spectral Signatures of Heart, Kidney, and Liver Tissues
- 15 August 2022
- Published by Springer Nature in Water Conservation Science and Engineering
- Vol. 7 (4) , 515-523
Toward Practical Analysis of Wastewater Contaminants Employing Dual Spectroscopic Techniques
- 15 August 2022
- Published by Springer Nature in Water Conservation Science and Engineering
- Vol. 7 (4) , 515-523
Toward Practical Analysis of Wastewater Contaminants Employing Dual Spectroscopic Techniques
- 1 March 2022
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 37, 102699
Radiofrequency ablation for liver: Comparison between expert eye and hyperspectral imaging assessment
- 1 March 2022
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 37, 102699
Radiofrequency ablation for liver: Comparison between expert eye and hyperspectral imaging assessment
- 6 July 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (9) , 2671
Correction to: High Precision Monitoring of Radiofrequency Ablation for Liver Using Hyperspectral Imaging
- 6 July 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (9) , 2671
Correction to: High Precision Monitoring of Radiofrequency Ablation for Liver Using Hyperspectral Imaging
- 1 June 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (9) , 2430-2440
High Precision Monitoring of Radiofrequency Ablation for Liver Using Hyperspectral Imaging
Minimally invasive procedures are achieving better satisfaction for treating liver cancers. Energy-based techniques were studied as prospective alternatives to the gold standard of liver transplantation. Among these techniques, radiofrequency (RF) was investigated for the selective ablation of liver tissue. In addition to optimizing the RF settings for the purpose of overcoming tissue perforation or inadequate ablation, an instrument collecting quantitative data regarding the intraoperative tissue status can aid the treatment procedure. This study demonstrates an innovative noninvasive technique using hyperspectral imaging (HSI) for monitoring RF ablative therapy in ex-vivo liver tissue. The cubic data generated by HSI provides spectral as well as spatial properties of the liver tissue included in each pixel of the field of view. In our study, the applied statistical analysis saves the computational burdens of multivariate analysis techniques. For this purpose, spectral angle mapper, logistic regression algorithm, and principal component analysis were applied. Of all spectral bands captured by the HSI camera, bands centered at 760 and 960 nm were identified for predicting the ablated area. Based on statistical analysis, the threshold for predicting the ablated area of the liver samples was determined, provided that the specificity is kept at 90%.
- 1 June 2021
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 49 (9) , 2430-2440
High Precision Monitoring of Radiofrequency Ablation for Liver Using Hyperspectral Imaging
Minimally invasive procedures are achieving better satisfaction for treating liver cancers. Energy-based techniques were studied as prospective alternatives to the gold standard of liver transplantation. Among these techniques, radiofrequency (RF) was investigated for the selective ablation of liver tissue. In addition to optimizing the RF settings for the purpose of overcoming tissue perforation or inadequate ablation, an instrument collecting quantitative data regarding the intraoperative tissue status can aid the treatment procedure. This study demonstrates an innovative noninvasive technique using hyperspectral imaging (HSI) for monitoring RF ablative therapy in ex-vivo liver tissue. The cubic data generated by HSI provides spectral as well as spatial properties of the liver tissue included in each pixel of the field of view. In our study, the applied statistical analysis saves the computational burdens of multivariate analysis techniques. For this purpose, spectral angle mapper, logistic regression algorithm, and principal component analysis were applied. Of all spectral bands captured by the HSI camera, bands centered at 760 and 960 nm were identified for predicting the ablated area. Based on statistical analysis, the threshold for predicting the ablated area of the liver samples was determined, provided that the specificity is kept at 90%.
- 1 March 2021
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 33, 102195
Hyperspectral imaging assessment for radiotherapy induced skin-erythema: Pilot study
- 1 March 2021
- Published by Elsevier in Photodiagnosis and Photodynamic Therapy
- Vol. 33, 102195
Hyperspectral imaging assessment for radiotherapy induced skin-erythema: Pilot study