Jeroen A. Pikkemaat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeroen A. Pikkemaat has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- A J van der Kogel
Department of Structural Cell Biology, Max Planck Institute of Biochemistry, Martinsried, Germany
1 shared publication A W T Konings
Department of Radiation and Stress Cell Biology, University of Groningen, The Netherlands
1 shared publication- Bert U. W. Maes
University of Antwerp Groenenborgerlaan 171
1 shared publication Cornelis Altona
Leiden Institute of Chemistry, Gorlaues Laboratories, Leiden University, P.O. Box 9502, 2300 RA, The Netherlands
1 shared publicationCéline Joie
Janssen R&D Pharmaceutical Development and Manufacturing Sciences, Beerse, Belgium; Department of Chemistry-Organic Synthesis, University of Antwerp, Antwerp, Belgium
1 shared publication- Dirk Burdinski
Department of Bio-Molecular Engineering, Philips Research, High Tech Campus 11, NL-5656 AE Eindhoven
1 shared publication
Latest Publications
- Open Access
- 10 December 2022
- Published by MDPI AG in Metabolites
- Vol. 12 (12) , 1248
R Shiny App for the Automated Deconvolution of NMR Spectra to Quantify the Solid-State Forms of Pharmaceutical Mixtures
Bioavailability and chemical stability are important characteristics of drug products that are strongly affected by the solid-state structure of the active pharmaceutical ingredient (API). In pharmaceutical development and quality control activities, solid-state NMR (ssNMR) has proved to be an excellent tool for the detection and accurate quantification of undesired solid-state forms. To obtain correct quantitative outcomes, the resulting spectrum of an analytical sample should be deconvoluted into the individual spectra of the pure components. However, the ssNMR deconvolution is particularly challenging due to the following: the relatively large line widths that may lead to severe peak overlap, multiple spinning sidebands as a result of applying Magic Angle Spinning (MAS), and highly irregular peak shapes commonly observed in mixture spectra. To address these challenges, we created a tailored and automated deconvolution approach of ssNMR mixture spectra that involves a linear combination modelling (LCM) of previously acquired reference spectra of pure solid-state components. For optimal model performance, the template and mixture spectra should be acquired under the same conditions and experimental settings. In addition to the parameters controlling the contributions of the components in the mixture, the proposed model includes terms for spectral processing such as phase correction and horizontal shifting that are all jointly estimated via a non-linear, constrained optimisation algorithm. Finally, our novel procedure has been implemented in a fully functional and user-friendly R Shiny webtool (hence no local R installation required) that offers interactive data visualisations, manual adjustments to the automated deconvolution results, and the traceability and reproducibility of analyses.
- 10 December 2022
- Published by MDPI AG in Metabolites
- Vol. 12 (12) , 1248
Open AccessR Shiny App for the Automated Deconvolution of NMR Spectra to Quantify the Solid-State Forms of Pharmaceutical Mixtures
Bioavailability and chemical stability are important characteristics of drug products that are strongly affected by the solid-state structure of the active pharmaceutical ingredient (API). In pharmaceutical development and quality control activities, solid-state NMR (ssNMR) has proved to be an excellent tool for the detection and accurate quantification of undesired solid-state forms. To obtain correct quantitative outcomes, the resulting spectrum of an analytical sample should be deconvoluted into the individual spectra of the pure components. However, the ssNMR deconvolution is particularly challenging due to the following: the relatively large line widths that may lead to severe peak overlap, multiple spinning sidebands as a result of applying Magic Angle Spinning (MAS), and highly irregular peak shapes commonly observed in mixture spectra. To address these challenges, we created a tailored and automated deconvolution approach of ssNMR mixture spectra that involves a linear combination modelling (LCM) of previously acquired reference spectra of pure solid-state components. For optimal model performance, the template and mixture spectra should be acquired under the same conditions and experimental settings. In addition to the parameters controlling the contributions of the components in the mixture, the proposed model includes terms for spectral processing such as phase correction and horizontal shifting that are all jointly estimated via a non-linear, constrained optimisation algorithm. Finally, our novel procedure has been implemented in a fully functional and user-friendly R Shiny webtool (hence no local R installation required) that offers interactive data visualisations, manual adjustments to the automated deconvolution results, and the traceability and reproducibility of analyses.
- 23 October 2020
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (11) , 7639-7645
Magnetic Resonance Monitoring of Opaque Temperature-Sensitive Polymeric Scaffolds
The monitoring of location and degradation rates of injectable biomaterials is an area of particular interest in the design and implementation of therapeutic scaffolds and carriers for tissue repair and replacement. We describe here the fabrication and characterization of gadolinium (Gd)-labeled temperature-responsive hydrogels that can be detected noninvasively using T-1-weight magnetic resonance. Two acrylamide-functionalized Gd(III)DOTA-monoamide complexes with either a short n-butylene spacer (Gd-III-C4-AA) or a long hydrophilic spacer (Gd-III-PEG-AA) were synthesized and incorporated into the hydrogels. At temperatures above the lower critical solution temperature (LCST), 37 degrees C, these hydrogels have the capacity to enhance relaxivity (r(1)) due to the hydrophobic interactions of the polyamide chains around the gadolinium chelates. This effect is further accentuated by the presence of the polyethylene glycol groups of the Gd complex Gd-III-PEG-AA.
- 23 October 2020
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (11) , 7639-7645
Magnetic Resonance Monitoring of Opaque Temperature-Sensitive Polymeric Scaffolds
The monitoring of location and degradation rates of injectable biomaterials is an area of particular interest in the design and implementation of therapeutic scaffolds and carriers for tissue repair and replacement. We describe here the fabrication and characterization of gadolinium (Gd)-labeled temperature-responsive hydrogels that can be detected noninvasively using T-1-weight magnetic resonance. Two acrylamide-functionalized Gd(III)DOTA-monoamide complexes with either a short n-butylene spacer (Gd-III-C4-AA) or a long hydrophilic spacer (Gd-III-PEG-AA) were synthesized and incorporated into the hydrogels. At temperatures above the lower critical solution temperature (LCST), 37 degrees C, these hydrogels have the capacity to enhance relaxivity (r(1)) due to the hydrophobic interactions of the polyamide chains around the gadolinium chelates. This effect is further accentuated by the presence of the polyethylene glycol groups of the Gd complex Gd-III-PEG-AA.
- Open Access
- 29 December 2017
- Published by Springer Nature in Parasites & Vectors
- Vol. 10 (1) , 1-3
2-methyl butyramide, a previously identified urine biomarker for Ascaris lumbricoides, is not present in infected Indonesian individuals
Previous reports suggest that the 2-methyl butyramide and 2-methyl valeramide metabolites of Ascaris lumbricoides in urine of infected individuals could be considered as urinary biomarkers for active infection. We have developed an LC-MS method with a detection limit of 10 ng/mL using synthetic chemicals as reference material. Urine samples (n = 21) of infected individuals were analyzed for the presence of these metabolites, but they were not detected in any of the samples. Furthermore, the recorded 1H-NMR spectrum for reference 2-methyl butyramide did not match with the spectrum that was described for the Ascaris metabolite. Based on these two observations, we concluded that the urinary biomarkers that were detected for A. lumbricoides infection are not 2-methyl butyramide nor 2-methylvaleramide. New discovery efforts will be required to identify the structure of these metabolite biomarkers in urine of infected individuals. Urine samples used in this study were collected as part of a clinical trial with trial number ISRCTN75636394 (12 November 2013).
- 29 December 2017
- Published by Springer Nature in Parasites & Vectors
- Vol. 10 (1) , 1-3
Open Access2-methyl butyramide, a previously identified urine biomarker for Ascaris lumbricoides, is not present in infected Indonesian individuals
Previous reports suggest that the 2-methyl butyramide and 2-methyl valeramide metabolites of Ascaris lumbricoides in urine of infected individuals could be considered as urinary biomarkers for active infection. We have developed an LC-MS method with a detection limit of 10 ng/mL using synthetic chemicals as reference material. Urine samples (n = 21) of infected individuals were analyzed for the presence of these metabolites, but they were not detected in any of the samples. Furthermore, the recorded 1H-NMR spectrum for reference 2-methyl butyramide did not match with the spectrum that was described for the Ascaris metabolite. Based on these two observations, we concluded that the urinary biomarkers that were detected for A. lumbricoides infection are not 2-methyl butyramide nor 2-methylvaleramide. New discovery efforts will be required to identify the structure of these metabolite biomarkers in urine of infected individuals. Urine samples used in this study were collected as part of a clinical trial with trial number ISRCTN75636394 (12 November 2013).
- Open Access
- 1 May 2017
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 106 (5) , 1310-1316
“Dark” Singlet Oxygen and Electron Paramagnetic Resonance Spin Trapping as Convenient Tools to Assess Photolytic Drug Degradation
- 1 May 2017
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 106 (5) , 1310-1316
Open Access“Dark” Singlet Oxygen and Electron Paramagnetic Resonance Spin Trapping as Convenient Tools to Assess Photolytic Drug Degradation
- Open Access
- 26 August 2008
- Published by Wiley in Chemistry & Biodiversity
- Vol. 5 (8) , 1505-1512
The Thulium Complex of 1,4,7,10‐Tetrakis{[N‐(1H‐imidazol‐2‐yl)carbamoyl]methyl}‐1,4,7,10‐tetraazacyclododecane (dotami) as a ParaCEST Contrast Agent
1,4,7,10‐Tetrakis{[N‐(1H‐imidazol‐2‐yl)carbamoyl]methyl}‐1,4,7,10‐tetraazacyclododecane (dotami), a tetra(1H‐imidazol‐2‐yl) derivative of the well‐studied octadentate 1,4,7,10‐tetrakis[(carbamoyl)methyl]‐1,4,7,10‐tetraazacyclododecane (dotam) ligand, was synthesized by reaction of 1,4,7,10‐tetraazacyclododecane with N‐(1H‐imidazol‐2‐yl)chloroacetamide in high yield. Its tricationic thulium complex was isolated as a water‐soluble chloride salt. The detection of the mildly acidic amide and amine protons by direct proton NMR in aqueous solution was unsuccessful, but such exchangeable protons could be detected via their chemical exchange‐dependent saturation transfer (CEST) effect. The observed CEST effect was distinctly different from that found for respective dotam complexes and is, therefore, ascribed to exchangeable protons associated with the imidazole substituent.
- 26 August 2008
- Published by Wiley in Chemistry & Biodiversity
- Vol. 5 (8) , 1505-1512
Open AccessThe Thulium Complex of 1,4,7,10‐Tetrakis{[N‐(1H‐imidazol‐2‐yl)carbamoyl]methyl}‐1,4,7,10‐tetraazacyclododecane (dotami) as a ParaCEST Contrast Agent
1,4,7,10‐Tetrakis{[N‐(1H‐imidazol‐2‐yl)carbamoyl]methyl}‐1,4,7,10‐tetraazacyclododecane (dotami), a tetra(1H‐imidazol‐2‐yl) derivative of the well‐studied octadentate 1,4,7,10‐tetrakis[(carbamoyl)methyl]‐1,4,7,10‐tetraazacyclododecane (dotam) ligand, was synthesized by reaction of 1,4,7,10‐tetraazacyclododecane with N‐(1H‐imidazol‐2‐yl)chloroacetamide in high yield. Its tricationic thulium complex was isolated as a water‐soluble chloride salt. The detection of the mildly acidic amide and amine protons by direct proton NMR in aqueous solution was unsuccessful, but such exchangeable protons could be detected via their chemical exchange‐dependent saturation transfer (CEST) effect. The observed CEST effect was distinctly different from that found for respective dotam complexes and is, therefore, ascribed to exchangeable protons associated with the imidazole substituent.
- 5 October 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (11) , 2857-2871
Techniques for precision irradiation of the lateral half of the rat cervical spinal cord using 150 MeV protons
Techniques for high precision irradiation experiments with protons, to investigate the volume dependence of the tolerance dose of the rat cervical spinal cord are described. In the present study, 50% of the lateral cross section of the spinal cord was irradiated. The diameter of the cross section of this part of the rat spinal cord is at maximum 3.5 mm. Therefore, a dedicated procedure was developed to comply with the needs for a very high positioning accuracy and high spatial resolution dosimetry. By using 150 MeV protons a steep dose gradient (20-80% = 1 mm) in the centre of the spinal cord was achieved. This yields a good dose contrast between the left and right halves of the cord. A home-made digital x-ray imager with a pixel resolution of 0.18 mm/pixel was used for position verification of the spinal cord. A positioning accuracy of 0.09 mm was obtained by using information of multiple pixels. The average position stability during the irradiation was found to be 0.08 mm (1 SD) without significant systematic deviations. Profiles of the dose distribution were measured with a 2D dosimetry system consisting of a scintillating screen and a CCD camera. Dose volume histograms of the whole spinal cord as well as separately of the white and grey matters were calculated using MRI imaging of the cross section of the rat cervical spinal cord. From the irradiation of 20 animals a dose-response curve has been established. MRI showed radiation-induced damage at the high dose side of the spinal cord. Analysis of the preliminary dose-response data shows a significant dose-volume effect. With the described procedure and equipment it is possible to perform high precision irradiations on selected parts of the spinal cord.
- 5 October 2001
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (11) , 2857-2871
Techniques for precision irradiation of the lateral half of the rat cervical spinal cord using 150 MeV protons
Techniques for high precision irradiation experiments with protons, to investigate the volume dependence of the tolerance dose of the rat cervical spinal cord are described. In the present study, 50% of the lateral cross section of the spinal cord was irradiated. The diameter of the cross section of this part of the rat spinal cord is at maximum 3.5 mm. Therefore, a dedicated procedure was developed to comply with the needs for a very high positioning accuracy and high spatial resolution dosimetry. By using 150 MeV protons a steep dose gradient (20-80% = 1 mm) in the centre of the spinal cord was achieved. This yields a good dose contrast between the left and right halves of the cord. A home-made digital x-ray imager with a pixel resolution of 0.18 mm/pixel was used for position verification of the spinal cord. A positioning accuracy of 0.09 mm was obtained by using information of multiple pixels. The average position stability during the irradiation was found to be 0.08 mm (1 SD) without significant systematic deviations. Profiles of the dose distribution were measured with a 2D dosimetry system consisting of a scintillating screen and a CCD camera. Dose volume histograms of the whole spinal cord as well as separately of the white and grey matters were calculated using MRI imaging of the cross section of the rat cervical spinal cord. From the irradiation of 20 animals a dose-response curve has been established. MRI showed radiation-induced damage at the high dose side of the spinal cord. Analysis of the preliminary dose-response data shows a significant dose-volume effect. With the described procedure and equipment it is possible to perform high precision irradiations on selected parts of the spinal cord.
- 1 April 1999
- Published by Elsevier in Archives of Biochemistry and Biophysics
- Vol. 364 (1) , 53-60
Thermodynamic Properties of an Intramolecular DNA Four-Way Junction
- 1 April 1999
- Published by Elsevier in Archives of Biochemistry and Biophysics
- Vol. 364 (1) , 53-60
Thermodynamic Properties of an Intramolecular DNA Four-Way Junction